• 제목/요약/키워드: CHOKe

검색결과 117건 처리시간 0.026초

설계 및 탈설계점에서의 원심압축기 채널디퓨저 내부의 압력분포에 관한 연구 (A Study on the Pressure Distribution in the Centrifugal Compressor Channel Diffuser at Design and Off-Design Conditions)

  • 강정식;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.548-554
    • /
    • 2000
  • The aim of this paper is to understand the time averaged pressure distributions in a high-speed centrifugal compressor channel diffuser at design and off-design flow rates. Pressure distributions from the impeller exit to the channel diffuser exit are measured and discussed far various flow rates from choke to near surge condition, and the effect of operating condition is discussed. The strong non-uniformity in the pressure distribution is obtained over the vaneless space and semi-vaneless space caused by the impeller-diffuser interaction. As the flow rate increases, flow separation near the throat, due to large incidence angle at the vane leading edge, increases aerodynamic blockage and reduces the aerodynamic flow area downstream. Thus the minimum pressure location occurs downstream of the geometric throat, and it is named as the aerodynamic throat. And at choke condition, normal shock occurs downstream of this aerodynamic throat. The variation in the location of the aerodynamic throat is discussed.

  • PDF

공기 유입시의 터보펌프 특성 (Air Influx Characteristics of Turbo Pumps)

  • 김유택;남청도;강호근;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.43-48
    • /
    • 2004
  • A screw-type centrifugal pump was manufactured to carry solids primarily and its impeller has a wide flow passage. However, the effect of flow passage shape on delay of the choke due to entrained air has not been clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For that reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that loss of pump head from single-phase flow to the choke due to air entrainment new the best efficiency point was large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

유압관로에서 원통형 초크의 비정상 유동의 주파수 특성에 관한 연구 (Frequency Characteristics of Unsteady Flow of Cylindrical Choke in a Hydraulic Pipe)

  • 박선종;유영태;위광환
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.421-434
    • /
    • 1995
  • A new instantaneous flowmeter for hydraulics by means or cylindrical chokes is developed. In this method the instantaneous flowrate through chokes is predicted in real time from measurement of pressure difference on both sides of cylindrical choke. The experimental study for the flowrate of pulsating flow in a pipe is carried out to measure differential pressure drop by using a strain gauge pressure transducer with data acquisition and processing system. A pulsating flow is verified by a visualization method. In the present study, the flow characteristic variables of laminar pulsating flow are investigated analytically and experimentally in a circular pipe. Characteristic parameters of ratio of inertia term to pressure term($\phi_{t.1}$) and ratio of viscous term to pressure term($\phi_{z.1}$) are introduced to describe the flow pattern of laminar pulsating flow.

  • PDF

4분의 1 파장 초크 구조를 이용한 동축형 대역억제필터 (A Coaxial Band Rejection Filter using a Quarter Wavelength Choke Structure)

  • 한대현
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.313-318
    • /
    • 2018
  • 전자빔과 상호작용하는 공동공진기를 위한 동축형 대역억제필터를 설계하고 제작하였다. 제안한 필터는 공동공진기의 기본모드에 대해 4분의 1 파장 길이의 초크를 가진다. 동축형 대역억제필터의 등가회로를 제시하고 각 부분의 ABCD 파라미터를 구하여 필터 전체의 ABCD 행렬을 구했다. ABCD 행렬로부터 산란행렬을 구하여 MATLAB으로 필터를 시뮬레이션하였다. 동축형 대역억제필터 구조를 HFSS를 이용하여 시뮬레이션을 수행하여 등가회로로 시뮬레이션이 유용함을 확인하였다. 설계한 동축형 대역억제필터는 6-1/8 플랜지를 가지는 필터를 제작하였다. 제작한 필터는 6-1/8 플랜지에서 N 형 플랜지로 변환하는 변환기를 사용하여 측정하였다. 제작된 필터의 삽입손실은 공동공진기의 기본모드에서 25 dB 이상이고 1차 고차모드에서 0.25 dB 보다 작다. 측정측정 결과는 시뮬레이션한 결과와 잘 일치하며 설계 규격을 만족한다.

배곧은근의 혈관 주행에 관한 시신해부 및 컴퓨터단층촬영 (Cadever dissection and Dynamic CT for Vascular Anatomy of Rectus Abdominis Muscle)

  • 손대구;박병주;김진한;최태현;김준형;한기환
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.663-668
    • /
    • 2008
  • Purpose: Pedicled transverse rectus abdominis myocutaneous(TRAM) flap has been a gold standard for breast reconstruction and one of surgical techniques preferred by many surgeons. The authors examined the course of deep epigastric artery focusing on distance from margins of rectus abdominis to pedicle and location of choke vessels to get minimal muscles during pedicled TRAM flap operation. Methods: Eleven rectus abdominis muscle from nine cadavers were used in this study. Rectus abdominis was separated from the cadavers, deep inferior and superior epigastric artery were isolated and then 8 anatomical landmarks in medial and lateral margins of rectus abdominis were designated. Distance to a pedicle meeting first horizontally was measured and vertical location from umbilicus to choke vessel was determined. In addition, 32 rectus abdominis images of 16 women(average age: 37.2 years old) from 64 channel abdomen dynamic computerized tomography were also examined with the same anatomical landmarks with those of cadavers. Results: Average distance from four landmarks on lateral margin of rectus abdominis to pedicle was 1.9 - 3.4cm and 1.8 - 3.8 cm on medial margin. Choke vessel was located between middle and inferior tendinous intersection in all cases and average distance between two tendinous intersection was 6.7 - 7.0 cm on medial margin and 6.2 cm on lateral margin. Location of inferior tendinous intersection was on umbilicus or superior of it in all cases and its average distance from umbilicus was 1.8 - 5.6 cm on medial margin and 2.7 - 6.2 cm on lateral margin. Conclusion: Distance from medial and lateral margins of rectus abdominis muscle to pedicle was the shortest in inferior tendinous intersection and that was averagely 1.8 cm on medial margin and 1.9 cm in average on lateral margin. All choke vessels were located between middle and inferior tendinous intersection.

영구자석을 이용한 밸브모드 MR 감쇠기 설계에 관한 연구 (A Study on the Design of Valve Mode MR Damper using Permanent Magnet)

  • 김정훈;오준호
    • 한국정밀공학회지
    • /
    • 제17권10호
    • /
    • pp.69-76
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectiories.

  • PDF

소형 스크류식 원심펌프의 기액 이상류 특성 (Characteristics of a Small Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow)

  • 김유택;다나카카즈히로;이영호
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.9-15
    • /
    • 1999
  • A screw-type centrifugal pump was manufactured to carry primarily solids and its impeller had a wide flow passage. However, there was an effect on the flow passage shape on delay of the choke due to entrained air not being clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For this reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that there was a loss of pump head from single-phase flow to the choke due to air entrainment near the best efficiency point being large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

압축수의 임계유량에 관한 해석적 연구 (An Analytical Study for Critical Mass Flowrate of Compressed Water)

  • 김희동;김재형;한민교;박경암
    • 한국추진공학회지
    • /
    • 제7권1호
    • /
    • pp.57-65
    • /
    • 2003
  • 본 연구에서는 압축수가 노즐을 통해 급격히 팽창될 때 기액이상류가 플래싱 증발하게 되는 이상류의 임계유동을 Isentropic-Homogeneous-Equilibrium model과 Leung model을 사용해 해석하였다. 그 결과 이상유동은 연속/불연속적 초크로 될 수 있으며, 정체점의 압력이 10Mpa일 경우에는 단상류 유동의 초크현상과 유사한 연속적인 초크현상이 정체점의 아냉각도가 10K이하일 경우에만 발생한다는 것을 알았다.

시나리오 기반 시뮬레이션을 활용한 북한지역 반격 시 물자수송 능력 분석방법 연구 (A Study on Material Transportation Capability Analysis Method in NK using Scenario-based Simulation)

  • 최병권;정석재
    • 한국군사과학기술학회지
    • /
    • 제20권2호
    • /
    • pp.279-288
    • /
    • 2017
  • The Material Transportation Capability Analysis Method in North Korea includes adversary's activities such as destruction of bridge which is one kind of choke points in the road network and surprise attack against resupply march unit. Also, the amount of damage on choke points in the road network and repair time depending on repair unit commitment must be reflected. In this study, a scenario encompassing plausible resupply transportation circumstances while counterattacking into NK will be established. Then, based on such scenario, a simulation model will be established and the result of simulation will be compared to the results of numeric example which has been used in the ROK Army. We demonstrate, through a certain Corps operation area, that the Scenario-based Simulation Model results predict the performance of resupply operation very well. Therefore, it makes sustainment planners and commanders do activities which is suitable for battlefield and should be used in the real situation. It is also a stochastic model.

영구자석을 이용한 저전력형 MR 감쇠기의 설계 (The design of low-power MR damper using permanent magnet)

  • 김정훈;오준호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.433-439
    • /
    • 2000
  • Lots of semi-active control devices have been developed in recent years because they have the best features of passive and active system. Especially, controllable magneto-rheological(MR) fluid devices have received significant attention in these area of research. The MR fluid is the material that reversibly changes from a free-flowing, linear viscous fluid to a semisolid with a controllable yield strength in milliseconds when exposed to a magnetic field. If the magnetic field is induced by moving a permanent magnet instead of applying current to a solenoid, it is possible to design a MR damper consuming low power because the power consumption is reduced at steady state. This paper proposes valve mode MR damper using permanent magnetic circuit that has wide range of operation with low power consumption and small size. To design a MR damper that has a large maximum dissipating torque and a low damping coefficient, a design parameter is adopted. The magnetic circuit, material of choke and choke type are selected experimentally with the design parameter. The behaviors of the damper are examined and torque tracking control using PID feedback controller is performed for step, ramp and sinusoidal trajectories.

  • PDF