• 제목/요약/키워드: CFT Pier

검색결과 14건 처리시간 0.023초

Top Down 공사에서의 CFT 선기초기둥 활용방안 (Use of Concrete Filled Tube as a Pre-founded Column for Top Down Construction)

  • 강승룡;임홍철;김승원;김동건;송지윤;정미라;이해출
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.31-34
    • /
    • 2008
  • Construction of buildings downtown is increasing as much as ever with a strong demand. A Top-Down Method is suitable for its advantage in minimizing its disturbance to the neighborhood. In general, the Pre-founded Column, one of the most important aspects of the Top-Down Method, has been made with an H-Shape Steel Column. However, due to its structural and economical benefits, the usage of CFT(Concrete Filled Tube) columns in the place of Pre-founded Columns is increasing. To promote their applications, we analyze the merits of CFT columns by comparing them with I-Shape columns and propose further research.

  • PDF

원형 콘크리트 충전 강관(CFT) 기둥의 P-M 상관 곡선 평가 (Evaluation of P-M Interaction Curve for Circular Concrete-Filled Tube (CFT) Column)

  • 문지호;박금성;이학은
    • 대한토목학회논문집
    • /
    • 제34권2호
    • /
    • pp.355-365
    • /
    • 2014
  • 원형 콘크리트 충전 강관(CFT)은 급속시공이 가능하고 뛰어난 좌굴 성능 및 콘크리트의 구속효과와 같은 여러 장점을 가지고 있어, 건축물의 기둥이나 교량의 교각으로 이용되고 있다. 하지만 CFT는 이러한 장점에도 불구하고 널리 이용되고 있지 않고 있다. 이러한 이유는 CFT의 설계기준들이 서로 상이하여 보수적인 설계가 이루어지고 있는 것에 일부 기인한다. 이 연구에서는 CFT설계에 널리 이용되는 AISC 및 EC4 설계기준의 타당성을 기존 연구자들이 수행한 실험 결과 및 이 연구에서 수행된 유한요소해석 결과를 이용하여 검증하였다. 특히 축력과 휨모멘트가 동시에 작용하는 CFT에 대하여 AISC 및 EC4에서 제안한 P-M 상관곡선의 타당성 검증에 초점을 두었다. 연구 결과, 기존의 P-M 상관곡선은 CFT의 강도를 상당히 보수적으로 예측하는 것을 알 수 있었다. 이 연구에서는 개선된 P-M 상관곡선을 제안하고 기존 실험 결과 및 이 연구에서 수행한 유한요소해석 결과를 이용하여 검증하였다.

강재 플레이트 유한요소해석을 이용한 잔교 상부의 풀 박스 부재의 선정 (Design of Pull Box Members on the Landing Pier Using Finite Element Analysis of a Steel Plate)

  • 김성원;홍혜민;한택희;서승남
    • 한국연안방재학회지
    • /
    • 제4권3호
    • /
    • pp.111-118
    • /
    • 2017
  • In this study, pull box members were designed by finite element analysis of a steel plate covering a pull box to secure its safety on the landing pier dedicated to the large research survey ship. It was assumed that the maximum load is due to the 250 tonf class crane used for unloading work when the working environment in the upper part of the landing pier was considered. The safety of the pull box was evaluated by the comparison between the yield strength of the steel plate and the result of stress analysis on the steel plate due to the crane load. It was found that the stress at the plate from the crane load exceeded the yield strength of the steel(205MPa) when the upper part of the pull box was protected by a $1950{\times}1950mm$ steel plate cover. In order to compensate for this, a concrete filled steel tube(CFT) column with a diameter of 150 mm and a steel thickness of 10 mm was reinforced at the center of the plate, and the finite element analysis was carried out. However, the maximum stress at the steel plate was higher than the yield strength of the steel in some load cases so that it was tried to find appropriate thickness of the steel plate and diameter of the CFT columns. Finally, the analysis results showed that the safety of the pull box was secured when the thickness of the steel plate and the diameter of the CFT column were increased to 30mm and 180mm, respectively.

내부 구속 중공 CFT 교각의 내진성능에 대한 매개변수 연구 (Parametric Study on Seismic Performance of Internally Confined Hollow CFT Column)

  • 염응준;김현종;한택희;강영종
    • 한국방재학회 논문집
    • /
    • 제8권1호
    • /
    • pp.15-21
    • /
    • 2008
  • 내부 구속 중공 CFT(ICH-CFT) 기둥은 콘크리트의 양쪽(중공부와 외부)에 두 개의 강관이 삽입된 형태이다. 외부 강관과 내부 장관은 강관과 중공 부분으로 인하여 좋은 내진 성능과 연성을 발휘하며, 또한 에너지 흡수도 하는 기능을 가지고 있다. 그러므로 본 교각 형태의 실용성을 위한 연구가 필요하다고 할 수 있다. 본 논문에서는 ICH-CFT 기둥의 실용적인 설계를 목적으로, 내진성능에 대한 매개변수 연구를 실시하였다. 매개변수는 교각의 지름과 중공비 그리고 같은 모멘트 성능을 발휘하는 장관의 두께이다. 또한 경제성에 따른 연성도 평가와 CFT기둥과의 비교를 통하여 좀 더 실용적인 평가를 하고자 하였다. 특히, 중공비와 외부강관 두께에 따라 내진성능이 차이를 보였으며, ICH-CFT 교각의 외부강관의 두께에 따른 경제적인 중공비를 제시하였다.