• Title/Summary/Keyword: CFT

Search Result 424, Processing Time 0.03 seconds

Cyclic and static behaviors of CFT modular bridge pier with enhanced bracings

  • Kim, Dongwook;Jeon, Chiho;Shim, Changsu
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1221-1236
    • /
    • 2016
  • Modular structures consist of standardized modules and their connections. A modular bridge pier is proposed to accelerate bridge construction. Multiple concrete-filled steel tubes (CFTs) using commercial steel tubes were chosen as the main members. Buckling restrained bracings and enhanced connection details were designed to prevent premature low-cycle fatigue failure upon cyclic loading. The pier had a height of 7.95 m, widths of 2.5 m and 2.0 m along the strong and weak axis, respectively. Cyclic tests were performed on the modular pier to investigate structural performance. Test results showed that four CFT columns reached yielding without a premature failure of the bracing connections. The ultimate capacity of the modular pier was reasonably estimated based on the plastic-hinge-analysis concept. The modular CFT pier with enhanced bracing showed improved displacement ductility without premature failure at the welding joints.

Creep analysis of CFT columns subjected to eccentric compression loads

  • Han, Bing;Wang, Yuan-Feng;Wang, Qian;Zhang, Dian-Jie
    • Computers and Concrete
    • /
    • v.11 no.4
    • /
    • pp.291-304
    • /
    • 2013
  • By considering the creep characteristics of concrete core under eccentric compression, a creep model of concrete filled steel tubes (CFT) columns under eccentric compressive loads is proposed based on the concrete creep model B3. In this proposed model, a discrete element method is introduced to transform the eccentric loading into axial loading. The validity of the model is verified by comparing the predicting results with the published creep experiments results on CFT specimens under compressive loading, together with the predicting values based on other concrete creep models, such as ACI209, CEB90, GL2000 and elastic continuation and plastic flow theory. By using the proposed model, a parameters study is carried out to analysis the effects of practical design parameters, such as concrete mix (e.g. water to cement ratio, aggregate to cement ratio), steel ratio and eccentricity ratio, on the creep of CFT columns under eccentric compressive loading.

Nonlinear finite element analysis of circular concrete-filled steel tube structures

  • Xu, Tengfei;Xiang, Tianyu;Zhao, Renda;Zhan, Yulin
    • Structural Engineering and Mechanics
    • /
    • v.35 no.3
    • /
    • pp.315-333
    • /
    • 2010
  • The structural behaviors of circular concrete filled steel tube (CFT) structures are investigated by nonlinear finite element method. An efficient three-dimensional (3D) degenerated beam element is adopted. Based on those previous studies, a modified stress-strain relationship for confined concrete which introduces the influence of eccentricity on confining stress is presented. Updated Lagrange formulation is used to consider the geometrical nonlinearity induced by large deformation effect. The nonlinear behaviors of CFT structures are investigated, and the accuracy of the proposed constitutive model for confined concrete is mainly concerned. The results demonstrate that the confining effect in CFT elements subjected to combining action of axial force and bending moment is far sophisticated than that in axial loaded columns, and an appropriate evaluation about this effect may be important for nonlinear numerical simulation of CFT structures.

Experimental Study on the Bolt Assembly type CFT Seismic Reinforcement Construction Method (볼트조립식 CFT 내진보강공법에 관한 실험적 연구)

  • Kang, Su-Jin;Lee, Dong-Un;Yoon, Jung-Bae;Kim, Yong-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.6-7
    • /
    • 2020
  • The government of South Korea enacted Earthquake Recovery Plan Act in 2008. In order to meet the requirement of this law, the important buildings, such as schools, public offices and so on, are in the process of seismic retrofit. This paper introduces the experimental data about a non-retrofitted concrete column and retrofitted column with a bolt assembly type CFT(concrete-filled steel tube).

  • PDF

P-M Interaction Curve for Square CFTs with High-Strength Concrete (고강도 콘크리트를 사용한 각형 CFT 기둥의 축력-모멘트 상관곡선)

  • Choi, Young Hwan;Kim, Kang Su;Choi, Sung Mo;Lee, Sangsup
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.575-585
    • /
    • 2007
  • In this study, a new design equation was presented for square CFTs with high-strength concrete subjected to axial compression and bending. In a previous study, a design equation for square CFTs with normal strength concrete was proposed. A parametric study by fiber analysis was performed taking the width-to-thickness ratio (b/t) and the relative concrete strength to the yield strength of the steel tube (fck/Fy) as the main parameters of this study to determine the maximum moment and the axial load at the maximum moment. A new constitutive model for concrete was adopted for fiber analysis in order to take into account the effect of high-strength concrete. The results of the parametric study were embedded into the method which was presented in the previous study to formulate a new design equation that can be easily used for estimating the strength of square CFTs with high-strength concrete.

Evaluation of Flexural Behavior of a Modular Pier with Circular CFT (충전원형강관을 이용한 모듈러 교각의 휨 거동 평가)

  • Ma, Hyang Wook;Oh, Hyun Chul;Kim, Dong Wook;Kong, Davon;Shim, Chang Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.725-734
    • /
    • 2012
  • A new modular pier system using concrete filled circular steel tubes was suggested to realize modular bridge substructures for accelerated bridge construction. Structural details and connection details were proposed by connection multiple concrete filled tubes (CFT) for standardized products of fabrication, delivery and erection. Static tests were performed for the modular pier with suggested details under lateral load conditions for weak and strong axes. Due to the eccentricity by the bracing system, the modular pier showed 5.23 times higher flexural stiffness and 6 times greater flexural strength from the test. It is proper for the rational design to evaluate stress and deformation by frame modeling of the modular CFT pier. Structural capacity of the pier can be obtained by adjusting the spacing of the CFT columns. Design recommendations were derived from the test.

Prediction of Temperature Distribution to Evaluate Axial Strength of Unprotected Concrete-filled Steel Tubular Columns under Fire (화재 시 무피복 CFT 기둥의 축강도 평가를 위한 단면온도분포 예측기법의 개발)

  • Koo, Cheol Hoe;Lee, Cheol Ho;Ahn, Jae Kwon
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.6
    • /
    • pp.587-599
    • /
    • 2013
  • A simple but accurate analytical method to evaluate the fire resistance of unprotected concrete filled tubular (CFT) columns under standard fire condition is proposed based on the fire design framework of EC4. To this end, the accuracy of the current tabulation method for the temperature prediction proposed by Lawson et al. was first critically evaluated, and a new prediction equation for the temperature gradient across the CFT section was then proposed based on available test and finite element analysis results. Overall, the axial strength predicted by using the proposed equation under the general fire design framework of EC4 was more accurate than that based on existing methods and appeared reasonable for design purposes. The results of this study are directly usable for the more rational fire analysis and design of unprotected CFT columns.

Seismic Performance of Top and Seat Angle CFT Column-to-Beam Connections with SMA (SMA 적용 상·하부 ㄱ형강 CFT 기둥-보 접합부의 내진성능)

  • Kim, Joo-Woo;Lee, Sung Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.423-434
    • /
    • 2017
  • In this paper a systematic numerical analysis is performed to obtain the hysteresis behavior of partially restrained top and seat angle connections subjected to cyclic loading. This connection includes superelastic shape memory alloy (SMA) angles and rods in order to secure the recentering capacities as well as proper energy dissipation effects of a CFT composite frame. The three-dimensional nonlinear finite element models are constructed to investigate the rotational stiffness, bending moment capacity and failure modes. A wide scope of additional structural behaviors explain the different influences of the connection's parameters, such as the various thickness of connection angles and the gage distance of steel and SMA rods.

Dynamic Analysis and Safety Estimation of New Type Girder Filled by High-Strength Concrete (고강도 콘크리트를 적용시킨 신형식 거더의 동적해석 및 안정성 평가)

  • Choi, Sung-Woo;Lee, Hak;Kong, Jung-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.213-216
    • /
    • 2008
  • CFT(Concrete Filled Steel Tubular) Structure filled steel tubes with a concrete improves the stiffness and strength of the structure by the confinement effect of fillers. CFTA(Concrete Filled and Tied Steel Tubular Arch) girder is a new type structure that applies an arch structure and a pre-stressed structure to CFT Structure to maximize the efficiency of structure and economic. One of conspicuous characteristics of CFTA girder is exposed tendon and that is pointed out as the weak point of this girder. Therefore in this study, safety estimation for the exposed tendon is performed and dynamic analysis is also performed by the collision numerical simulation. For analyzing this model, ABAQUS 6.5-1 was used.

  • PDF