• 제목/요약/키워드: CFD technique

검색결과 423건 처리시간 1.043초

Wind engineering for high-rise buildings: A review

  • Zhu, Haitao;Yang, Bin;Zhang, Qilin;Pan, Licheng;Sun, Siyuan
    • Wind and Structures
    • /
    • 제32권3호
    • /
    • pp.249-265
    • /
    • 2021
  • As high-rise buildings become more and more slender and flexible, the wind effect has become a major concern to modern buildings. At present, wind engineering for high-rise buildings mainly focuses on the following four issues: wind excitation and response, aerodynamic damping, aerodynamic modifications and proximity effect. Taking these four issues of concern in high-rise buildings as the mainline, this paper summarizes the development history and current research progress of wind engineering for high-rise buildings. Some critical previous work and remarks are listed at the end of each chapter. From the future perspective, the CFD is still the most promising technique for structural wind engineering. The wind load inversion and the introduction of machine learning are two research directions worth exploring.

The Effect of Open Ratio of the Inlet Baffle on Hydraulic Behavior within a Rectangular Sedimentation Basin (장방형 침전지 유입 정류벽 유공비의 지내 수리거동에 미치는 영향 연구)

  • Park, No-Suk;Kim, Seong-Su;Lim, Sung-Eun;Lee, Doo-Jin;Seo, In-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제23권3호
    • /
    • pp.345-352
    • /
    • 2009
  • The purpose of inlet baffle is to distribute the flow uniformly over the entire cross-sectional area of the sedimentation basin. The goal when designing this baffle is to achieve some head loss while keeping the velocity gradients through the ports equal to the velocity gradient in the end of the flocculator, so as to not break up the flocs. Sedimentation tank performance is strongly influenced by hydrodynamic and physical effects such as inlet design. This study was conducted to evaluate the effect of open ratio of the inlet baffle on hydraulic behavior within a rectangular sedimentation basin using CFD simulation and ADV technique. In order to verify the CFD simulation, we measured the factual velocity at 18 points in the full-scale sedimentation basin at Y water treatment plant. Good agreement was obtained between the CFD predictions and the experimentally measured data. From the simulation results of the existing basin with 7.4 % open ratio, it was investigated that extreme decrease in velocity occurred in the middle of basin. Since then, flow features was unstable. The region which the velocity decrease rapidly moved forward to the flow direction in proportion to the increase of inflow velocity. Also, it was investigated that the flow characteristic of 6.0 % open ratio was significantly different from 7.4 % open ratio at the same configuration condition. These results are a clear indication that inflow momentum and open ratio are the parameters affecting the characteristics of hydraulic patterns. The influence of these parameters on the sedimentation performance requires further study.

Numerical Analysis of the Energy-Saving Tray Absorber of Flue-Gas Desulfurization Systems (배연탈황설비의 에너지 절약형 트레이 흡수탑에 대한 수치 해석적 연구)

  • Hwang, Jae-Min;Choi, Ssang-Suk;Chung, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제34권8호
    • /
    • pp.775-782
    • /
    • 2010
  • This study is performed to study the effect of the tray in the absorber of a flue-gas desulphurization (FGD) system by using a computational fluid dynamic (CFD) technique. Stagnant time of slurry and the pressure drop in the FGD absorber increase when a tray is used in the absorber. Stagnant time of slurry results in an increase in the desulfurization effect and a decrease in the power of the absorber recirculation pump; however, increased pressure drop requires more power of booster fan in the FGD system should be increased. The gas and slurry hydrodynamics inside the absorber is simulated using a commercial CFD code. The continuous gas phase has been modeled in an Eulerian framework, while the discrete liquid phase has been modeled by adopting a Lagrangian approach by tracking a large number of particles through the computational domain. It was observed that the power saved upon increasing the stagnant time of slurry was more than increased power with pressure drop.

Percutaneous Thrombin Injection Based on Computational Fluid Dynamics of Femoral Artery Pseudoaneurysms

  • Hyoung-Ho Kim;Kyung-Wuk Kim;Changje Lee;Young Ho Choi;Min Uk Kim;Yasutaka Baba
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1834-1840
    • /
    • 2021
  • Objective: To analyze the computational fluid dynamics (CFD) of femoral artery pseudoaneurysm (FAP), identify a suitable location and timing for percutaneous thrombin injection (PTI) based on this analysis, and report our clinical experience with the procedure. Materials and Methods: CFD can be used to analyze the hemodynamics of the human body. An analysis using CFD recommended that the suitable location of the needle tip for PTI is at the center of the aneurysm sac and the optimal timing for starting PTI is during the early inflow phase of blood into the sac. Since 2011, seven patients (three male and four female; median age, 60 years [range, 43-75 years]) with FAP were treated with PTI based on the devised suitable location and time. Prior to the procedure, color Doppler ultrasonography was performed to determine the location and timing of the thrombin injection. Results: The technical success rate of the PTI was 100%. The amount of thrombin used for the procedure ranged from 200 IU to 1000 IU (median, 500 IU). None of the patients experienced any symptoms or signs of embolic complications during the procedure. Follow-up CT images did not reveal any embolism in the lower extremities and showed complete thrombosis of the pseudoaneurysm. Conclusion: Based on our study of CFD, PTI administered centrally in the FAP during early inflow, as seen on color Doppler, can be an effective technique.

Multiscale Modeling and Simulation of Water Gas Shift Reactor (Water Gas Shift Reactor의 Multiscale 모델링 및 모사)

  • Lee, Ukjune;Kim, Kihyun;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • 제45권6호
    • /
    • pp.582-590
    • /
    • 2007
  • In view of the analysis of the phenomena and the prediction of the performance, mathematical modelling and simulation of a high temperature pilot reactor for water gas shift reaction (WGSR) has been carried out. Multiscale simulation incorporated computational fluid dynamics (CFD) technique, which has the capability to deal with the reactor shape, fluid and energy transport with extensive degree of accuracy, and process modeling technique, which, in turn is responsible for reaction kinetics and mass transport. This research employed multiscale simulation and the results were compared with those from process simulation. From multiscale simulation, the maximum conversion of was predicted approximately 0.85 and the maximum temperature at the reactor was calculated 720 K, resulting from the heat of reaction. Dynamic simulation was also performed for the time transient profile of temperature, conversion, etc. Considering the results, it is concluded that multiscale simulation is a safe and accurate technique to predict reactor behaviors, and consequently will be available for the design of commercial size chemical reactors as well as other commercial unit operations.

Hydrodynamic Hull Form Design Using an Optimization Technique

  • Park, Dong-Woo;Choi, Hee-Jong
    • International Journal of Ocean System Engineering
    • /
    • 제3권1호
    • /
    • pp.1-9
    • /
    • 2013
  • A design procedure for a ship with minimum resistance had been developed using a numerical optimization method called SQP (Sequential Quadratic Programming) combined with computational fluid dynamics (CFD) technique. The frictional resistance coefficient was estimated by the ITTC 1957 model-ship correlation line formula and the wave-making resistance coefficient was evaluated by the potential-flow panel method with the nonlinear free surface boundary conditions. The geometry of the hull surface was represented and modified by B-spline surface modeling technique during the optimization process. The Series 60 ($C_B$=0.60) hull was selected as a parent hull to obtain an optimized hull that produces minimum resistance. The models of the parent and optimized hull forms were tested at calm water condition in order to demonstrate the validity of the proposed methodolgy.

Numerical Evaluation of a Radially Variable Cell Density Strategy for Improving Light-off Performance: Focusing on Light-off Catalyst (자동차용 촉매변환기의 활성화 성능 향상을 위한 횡방향 가변 셀 밀도법의 수치적 평가: 활성화 촉매변환기를 중심으로)

  • 정수진;김우승
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제10권1호
    • /
    • pp.115-124
    • /
    • 2002
  • The optimum design of auto-catalyst needs a good compromise between the pressure drop and flow distribution in the monolith. One of the effective methods to achieve this goal is to use the concept of radially variable cell density. However, there has been no study of evaluating the usefulness of this method on light-off catalyst. We have computationally investigated the effectiveness of variable cell density technique applied to the light-off catalyst using a three-dimensional integrated CFD model. in which transient chemical reacting calculations are involved. Computed results show that variable cell density technique can reduce the accumulated emissions of CO and HC during the early 100sec of FTP cycle by 86.78 and 80.87%, respectively, The effect of air-gap between the monoliths has been also examined. It is found that air-gap has a beneficial effect on reducing pressure drop and cold-start emissions.

Measurement and Analysis on the Mixing Flows in a Tank with a Bottom Agitator using a Hybrid Volume Measurement Technique (하이브리드 볼륨측정법에 의한 하부교반 탱크내 혼합유동 측정 및 해석)

  • Doh, Deog Hee;Lee, Chang Jae;Baek, Tae Sil
    • Journal of the Korean Society of Visualization
    • /
    • 제10권3호
    • /
    • pp.42-47
    • /
    • 2012
  • Experimental data for the flows in a mixing tank with a bottom agitator are useful for the validation of CFD commercial code. A hybrid volume PIV measurement technique was constructed to measure the flows inside of the mixing tank. The measurement system consists of three cameras. An agitator was installed at the bottom of the tank and it rotates clockwise and counterclockwise. Using the constructed measurement system, instantaneous vector fields were obtained. A phase averaging technique was adopted for the measured instantaneous three-dimensional velocity vector fields. Turbulent properties were evaluated from the instantaneous vector fields.

Aerodynamic Analysis of Passenger Car with High Accuracy Using H-refinement (H-분할법을 이용한 승용차의 고정도 공력특성 해석)

  • 김태훈;정수진
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권5호
    • /
    • pp.33-41
    • /
    • 2000
  • Three dimensional flow fields around passenger car body was computed by PAM-FLOW, well-known and validated computer program for thermal and fluid analysis. Regarding the computational method, a Navier-Stokes solver based on finite element method with various turbulent models and adaptive grid technique (H-refinement)was adopted. The results were physically reasonable and compared with experimental data, giving good agreement. It was found that three dimensional flow simulation with H-refinement technique had potential for prediction of low fie이 around vehicle and the ability to predict vortex in the wake, which is vital for CFD to be used for automobile aerodynamic calculation.

  • PDF

Flow Safety Assessment by CFD Analysis in One-Touch Insertion Type Pipe Joint for Refrigerant (CFD 해석을 이용한 냉매용 원터치 삽입식 파이프 조인트의 유동 안전성 평가)

  • Kim, Eun-young;Park, Dong-sam
    • Journal of the Society of Disaster Information
    • /
    • 제18권3호
    • /
    • pp.550-559
    • /
    • 2022
  • Purpose: Pipes are widely used as applied devices in many industrial fields such as machinery, electronics, electricity, and plants, and are also widely used in safety-related fields such as firefighting and chemistry. With the diversification of products, the importance of technology in the piping field is also increasing. In particular, when changing the existing copper pipe to stainless steel, it is necessary to evaluate safety and flow characteristics through structural analysis or flow analysis. Method: This study investigated the safety by flow analysis of the 6.35 inch socket model, which are integrated insert type connectors developed by a company, using CFD analysis technique. For CDF analysis, RAN model and LES model are used. Result: As results of the analysis, amplitude of the pressure fluctuation acting on the wall of the piping system is formed at a level of 3,780 Pa or less, which is a very small level of pressure compared with the operating pressure or design stress of the refrigerant piping. Conclusion: These results mean that the effect of vibration caused by turbulence on the structural safety of the pipe is negligible.