• Title/Summary/Keyword: CFD(Computational FluidDynamics)

Search Result 2,032, Processing Time 0.037 seconds

Element Technology and Strategy of Digital Twin in the Water Treatment (수처리공정의 디지털 트윈 요소기술과 추진 전략)

  • Young-Man Cho;Yong-Jun Jung
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.284-290
    • /
    • 2023
  • Domestic water supply and sewage facilities are rapidly aging and maintenance difficulties such as aging of operation and management personnel are overlapping, so Digital Twin technology is attracting attention as an intelligent means of process management. Digital twin projects for domestic water treatment processes include the smart sewage treatment project promoted by the Ministry of Environment, projects independently promoted by some local governments, and digital twin purification plant projects promoted by K-water. However, the content of digital twin promotion is different for each institution. Therefore, in the water treatment process, technological standardization and step-by-step implementation methods for digital twins must be preceded to reduce trial and error in future business promotion. This study aims to provide an efficient promotion plan by prescribing the digital twin element technology and composition method in the water treatment process and reviewing the contents currently being promoted by the Ministry of Environment, local governments, and K-Water individually.

Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent (연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석)

  • Park, Min jung;Choi, Duck kyu;Son, Jin kwan;Yoon, Sung-Wook;Kim, Hee tae;Lee, Seung-Kee;Kang, Dong hyeon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • The objectives of this study were to investigate the standard and roof vent type of multi-span greenhouse and to analyze the characteristics of natural ventilation of multi-span greenhouse with different roof vent using computational fluid dynamics (CFD) code. The vent area proportion of surveyed farms averaged 10%, it was analyzed that the vent design for natural ventilation is insufficient. The results of natural ventilation efficiency of multi-span greenhouse according to roof vent type showed that the temperature of the position in which the crops grew was the lowest in the conical roof vent type and the highest in the half conical roof vent type. For the natural ventilation effect, the conical roof vent type was the best one, but the structural stability should be evaluated in light of wind load.

The Numerical Study on the Ventilation of Non-isothermal Concentrated Fume (수치해석적 방법을 이용한 비등온 고농도 연무의 배기량 산정에 관한 연구)

  • Lim, Seok-Chai;Chang, Hyuk-Sang;Ha, Ji-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.534-543
    • /
    • 2008
  • The experimental study with the prototype provides more acceptable data than the others. But there are so many limited conditions to perform the experimental study with the prototype. So the theoretical similitude with the scaled model and the numerical study with the CFD method have been chosen alternatively to analysis the fume movement. In this study, the ventilation was estimated from the results of the numerical study based on the experimental results as the boundary conditions. The grid A and B were same size and shape with the models which was used in the experimental study and consisted with 163,839, 122,965 cells respectively. The height of the fume layer was estimated form the mole fraction of fume components and the ventilation was determined by the velocity and temperature of the fume. The results of this study showed that the fume movements estimated from the numerical study are enough to apply to the prototype if there are proper heat loss correction factors. The numerical study is easier to change study conditions and faster to get results from the study than the experimental study. So if we find some proper heat loss correction factors, it's possible to execute the various and advanced study with the numerical study.

Effects of Meteorological and Reclaiming Conditions on the Reduction of Suspended Particles (기상 조건과 매립 조건이 비산 먼지 발생에 미치는 영향)

  • Choi, Jae-Won;Lee, Young-Su;Kim, Jae-Jin
    • Journal of Environmental Science International
    • /
    • v.19 no.11
    • /
    • pp.1423-1436
    • /
    • 2010
  • The effects of meteorological and reclaiming conditions on the reduction of suspended particles are investigated using a computational fluid dynamics (CFD) model with the k-$\varepsilon$ turbulence closure scheme based on the renormalization group (RNG) theory. Twelve numerical experiments with different meteorological and reclaiming conditions are performed. For identifying the meteorological characteristics of the target area and providing the inflow conditions of the CFD model, the observed data from the automatic weather station (AWS) near the target area is analyzed. Complicated flow patterns such as flow distortion, horse-shoe vortex, recirculation zone, and channeling flow appeared due to the topography and buildings in the domain. Specially, the flow characteristics around the reclamation area are affected by the reclaiming height, reclaiming size and windbreak height. Reclaiming height affected the wind speed above the reclaiming area. Windbreak induces more complicated flow patterns around the reclaiming area as well as within the reclaiming area. In front of the windbreak, flow is distorted as it impinges on the windbreak. As a result, upward flow is generated there. Behind the windbreak, a secondary circulation, so called, a recirculation zone is generated and flow is reattached at the end of the recirculation zone (reattachment point). At the lower part of the recirculation zone, there is a reverse flow toward the windbreak. Flow passing to the reattachment point starts to be recovered. Total amounts of suspended particles are calculated using the frictional and threshold frictional velocities, erosion potential function, and the number of surface disturbance. In the case of a 10 m-reclaiming and northerly wind, the amount of suspended particles is largest. In the presence of 5 m windbreak, the friction velocity above the reclaiming area is largely reduced. As a result, the total amount of the suspended particles largely decreases, compared to the case with the same reclaiming and meteorological conditions except for the windbreak The calculated suspended particle amounts are used as the emission rate of the dispersion model simulations and the dispersion characteristics of the suspended particles are analyzed.

Practical scaling method for underwater hydrodynamic model test of submarine

  • Moonesun, Mohammad;Mikhailovich, Korol Yuri;Tahvildarzade, Davood;Javadi, Mehran
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1217-1224
    • /
    • 2014
  • This paper provides a practical scaling method to solve an old problem for scaling and developing the speed and resistance of a model to full-scale submarine in fully submerged underwater test. In every experimental test in towing tank, water tunnel and wind tunnel, in the first step, the speed of a model should be scaled to the full-scale vessel (ship or submarine). In the second step, the obtained resistance of the model should be developed. For submarine, there are two modes of movement: surface and submerged mode. There is no matter in surface mode because, according to Froude's law, the ratio of speed of the model to the full-scale vessel is proportional to the square root of lengths (length of the model on the length of the vessel). This leads to a reasonable speed and is not so much for the model that is applicable in the laboratory. The main problem is in submerged mode (fully submerged) that there isn't surface wave effect and therefore, Froude's law couldn't be used. Reynold's similarity is actually impossible to implement because it leads to very high speeds of the model that is impossible in a laboratory and inside the water. According to Reynold's similarity, the ratio of speed of the model to the full-scale vessel is proportional to the ratio of the full-scale length to the model length that leads to a too high speed. This paper proves that there is no need for exact Reynold's similarity because after a special Reynolds, resistance coefficient remains constant. Therefore, there is not compulsion for high speeds of the model. For proving this finding, three groups of results are presented: two cases are based on CFD method, and one case is based on the model test in towing tank. All these three results are presented for three different shapes that can show; this finding is independent of the shapes and geometries. For CFD method, Flow Vision software has been used.

A Study on Wind Distribution of Mountain Area by Spot Measurements and Simulations (실측 및 해석을 통한 단순 산악지형의 바람장 분포 연구)

  • Kimg, Eung-Sik;Lee, Byung-Doo;Cho, Min-Tae;Kim, Jang-Whan
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.13-21
    • /
    • 2014
  • Forest fire has a number of variables and since the effects of wind fields are bigger than any other variables, it is essential to know wind direction and velocity for the forest fire extinguishing techniques and the prediction of fire spread. With regards to the local area that has a high chance of forest fire, the data from meteorological observatory in the area is used for the estimation of wind velocity. It is relatively easy to obtain automatic weather station (AWS) data which are available for the whole nation. There is a chance that the data from the weather station may be different with the actual data at the mountain areas. In this study simply shaped hills (Sae-byeol hill of Jeju Island and port Ma-geum in An-myeon Island in the sea side) were selected as the experimental locations to minimize the distortion of the wind field by the adjacent geographic features. Spot measurements and analysis of computational fluid dynamics (CFD) for the given geographic features were conducted to examine and compare their consistency. As a conclusion It is possible to predict wind patterns in these simple locations.

Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool (일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Shin, Jung-Ah;Kim, Tae-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

Characteristic of Mixing and DO Concentration Distribution in Aeration Tank by Microbubble Supply (마이크로버블 공급에 의한 폭기조내 교반과 용존산소 분포 특성)

  • Lim, Ji-young;Kim, Hyun-Sik;Park, Dae-Seok;Cho, Young-Gun;Song, Seung-Jun;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.251-259
    • /
    • 2016
  • This study examined the DO concentration distribution and ORP distribution using microbubbles on pilot-scale aeration tanks. As a result of MLSS mixing and oxygen transfer phenomenon using microbubbles, different DO concentrations were observed depending on the circulation of the liquid with the microbubble supply location on the lateral of an aeration tank. The simulation results of CFD (computational fluid dynamics) program showed that MLSS mixed with a microbubble supply in the middle the reactor is much better than on the left side of the reactor. A single reactor containing an anaerobic, anoxic, and aerobic zone, was evaluated without partition according to the location of the microbubble supply based on the experiments and CFD analysis. MLSS was separated into solid-liquid by the microbubble supply in the aeration tank. Consequently, selecting the appropriate microbubble size is important for MLSS mixing and was maintained at the proper DO concentration for biological treatment.

Anthracite Oxygen Combustion Simulation in 0.1MWth Circulating Fluidized Bed (0.1 MWth 급 순환유동층에서의 무연탄 연소 전산유체역학 모사)

  • Go, Eun Sol;Kook, Jin Woo;Seo, Kwang Won;Seo, Su Been;Kim, Hyung Woo;Kang, Seo Yeong;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.417-428
    • /
    • 2021
  • The combustion characteristics of anthracite, which follow a complex process with low reactivity, must be considered through the dynamic behavior of circulating fluidized bed (CFB) boilers. In this study, computational fluid dynamics (CFD) simulation was performed to analyze the combustion characteristics of anthracite in a pilot scale 0.1 MWth Oxy-fuel circulating fluidized bed (Oxy-CFB) boiler. The 0.1MWth Oxy-CFB boiler is composed of combustor (0.15 m l.D., 10 m High), cyclone, return leg, and so on. To perform CFD analysis, a 3D simulation model reactor was designed and used. The anthracite used in the experiment has an average particle size of 1,070 ㎛ and a density of 2,326 kg/m3. The flow pattern of gas-solids inside the reactor according to the change of combustion environment from air combustion to oxygen combustion was investigated. At this time, it was found that the temperature distribution in air combustion and oxygen combustion showed a similar pattern, but the pressure distribution was lower in oxygen combustion. addition, since it has a higher CO2 concentration in oxygen combustion than in air combustion, it can be expected that carbon dioxide capture will take place actively. As a result, it was confirmed that this study can contribute to the optimized design and operation of a circulating fluidized bed reactor using anthracite.

Numerical Prediction of the Powering Performance of a Car-Ferry in Irregular Waves for Safe Return to Port(SRtP) (불규칙 파랑 중 카페리선의 SRtP 소요마력 수치 추정 연구)

  • Park, Il-Ryong;Kim, Je-in;Suh, Sung-Bu;Kim, Jin;Kim, Kwang-Soo;Kim, Yoo-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • This paper considers a numerical assessment of the self-propulsion performance of a damaged ferry carrying cars in irregular waves. Computational fluid dynamics(CFD) simulations were performed to see whether the ferry complied with the Safe Return to Port (SRtP) regulations of Lloyd's register, which require that damaged passenger ships should be able to return to port with a speed of 6 knots (3.09 m/s) in Beaufort 8 sea conditions. Two situations were considered for the damaged conditions, i.e., 1) the portside propeller was blocked but the engine room was not flooded and 2) the portside propeller was blocked and one engine room was flooded. The self-propulsion results for the car ferry in intact condition and in the damaged conditions were assessed as follows. First, we validated that the portside propeller was blocked in calm water based on the available experimental results provided by KRISO. The active thrust of starboard propeller with the portside propeller blocked was calculated in Beaufort 8 sea conditions, and the results were compared with the experimental results provided by MARIN, and there was reasonable agreement. The thrust provided by the propeller and the brake horsepower (BHP) with one engine room flooded were compared with the values when the engine room was not flooded. The numerical results were compared with the maximum thrust of the propeller and the maximum brake horse power of the engine to determine whether the damaged car ferry could attain a speed of 6 knots(3.09 m/s).