• Title/Summary/Keyword: CECT

Search Result 13, Processing Time 0.04 seconds

Additional Value of Integrated 18F-FDG PET/MRI for Evaluating Biliary Tract Cancer: Comparison with Contrast-Enhanced CT

  • Jeongin Yoo;Jeong Min Lee;Jeong Hee Yoon;Ijin Joo;Dong Ho Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.714-724
    • /
    • 2021
  • Objective: To evaluate the value of 18F-fluorodeoxyglucose PET/MRI added to contrast-enhanced CT (CECT) in initial staging, assessment of resectability, and postoperative follow-up of biliary tract cancer. Materials and Methods: This retrospective study included 100 patients (initial workup [n = 65] and postoperative follow-up [n = 35]) who had undergone PET/MRI and CECT for bile duct or gallbladder lesions between January 2013 and March 2020. Two radiologists independently reviewed the CECT imaging set and CECT plus PET/MRI set to determine the likelihood of malignancy, local and overall resectability, and distant metastasis in the initial workup group, and local recurrence and distant metastasis in the follow-up group. Diagnostic performances of the two imaging sets were compared using clinical-surgical-pathologic findings as standards of reference. Results: The diagnostic performance of CECT significantly improved after the addition of PET/MRI for liver metastasis (area under the receiver operating characteristic curve [Az]: 0.77 vs. 0.91 [p = 0.027] for reviewer 1; 0.76 vs. 0.92 [p = 0.021] for reviewer 2), lymph node metastasis (0.73 vs. 0.92 [p = 0.004]; 0.81 vs. 0.92 [p = 0.023]), and overall resectability (0.79 vs. 0.92 [p = 0.007]; 0.82 vs. 0.94 [p = 0.021]) in the initial workup group. In the follow-up group, the diagnostic performance of CECT plus PET/MRI was significantly higher than that of CECT imaging for local recurrence (0.81 vs. 1.00 [p = 0.029]; 0.82 vs. 0.94 [p = 0.045]). Conclusion: PET/MRI may add value to CECT in patients with biliary tract cancer both in the initial workup for staging and determination of overall resectability and in follow-up for local recurrence.

Comparison Between Contrast-Enhanced Computed Tomography and Contrast-Enhanced Magnetic Resonance Imaging With Magnetic Resonance Cholangiopancreatography for Resectability Assessment in Extrahepatic Cholangiocarcinoma

  • Jeongin Yoo;Jeong Min Lee;Hyo-Jin Kang;Jae Seok Bae;Sun Kyung Jeon;Jeong Hee Yoon
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.983-995
    • /
    • 2023
  • Objective: To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). Materials and Methods: This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). Results: No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754-0.841] vs. 0.753 [0.697-0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). Conclusion: CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.

A Case of Massive Air Embolism after Contrast-enhanced Computed Tomography (조영증강 흉부전산화 단층촬영 후 발생한 대량의 공기 색전증 1예)

  • Park, Byeong Chool;Kil, Ho;Park, Chan Sun;Jeong, Jee In;Choi, Eun Young;Shin, Yoon Mi;Lee, Ki Man;Kim, Sung Jin;Choe, Kang Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.2
    • /
    • pp.178-182
    • /
    • 2007
  • A venous air embolism is a complication of various venous access procedures such as contrast-enhanced computed tomography (CECT). Although most cases of iatrogenic venous air embolisms during CECT involve a few milliliters of air and are asymptomatic, a massive venous air embolism can be fatal. We report a case of a massive intraventricular air embolism after CECT with a review of the literature regarding the pathophysiology and treatment of air embolisms.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

Ultrasonographic findings in Fitz-Hugh-Curtis syndrome: a thickened or three-layer hepatic capsule

  • Moon, You Ho;Kim, Jung ho;Jeong, Won joon;Park, Sin-Youl
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.1
    • /
    • pp.127-129
    • /
    • 2018
  • Fitz-Hugh-Curtis syndrome (FHCS) is characterized by inflammation of the perihepatic capsules associated with the pelvic inflammatory disease (PID). FHCS is not a serious disease, but if not treated properly, it can result in increased medical costs, prolonged treatment, and dissatisfaction with treatment. However, early recognition of FHCS in the emergency department can be difficult because its symptoms or physical findings may mimic many other diseases. Although contrast-enhanced computed tomography (CECT) is the useful imaging modality for recognition of FHCS, it is available only when a high suspicion is established. We performed point-of-care ultrasonography in an 18-year-old woman who had a sharp right upper quadrant (RUQ) abdominal pain without PID symptoms and found a thickened or three-layer hepatic capsule. These findings coincided with areas showing increased hepatic capsular enhancement in the arterial phase of CECT. These results show that if the thickened or three-layer hepatic capsule without evidence of a common cause of RUQ pain is observed on ultrasonography in women of childbearing age with RUQ abdominal pain, the physician can consider the possibility of FHCS.

Effect of Mixture of Lactobacillus plantarum CECT 7527, 7528, and 7529 on Obesity and Lipid Metabolism in Rats Fed a High-fat Diet (Lactobacillus plantarum CECT 7527, 7528, 7529 혼합물이 고지방식이를 급여한 흰쥐의 비만 및 지질 대사에 미치는 영향)

  • Kim, Dae Hwan;Choi, Mi-Ran;Hong, Ji Eun;Lee, Jae-Yong;Lee, Soon Im;Jung, Su Hwan;Kim, Eun Ji
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.10
    • /
    • pp.1484-1490
    • /
    • 2014
  • In the present study, we examined the effects of a mixture of three strains, Lactobacillus plantarum CECT 7527, 7528, and 7529 (L. plantarum mixture), on body weight and lipid metabolism in Sprague-Dawley rats fed a high-fat diet. Rats were fed a high-fat diet and subjected to oral gavage with vehicle or the L. plantarum mixture ($0.6{\times}10^9$, $1.2{\times}10^9$, $2.4{\times}10^9$ colony-forming units (CFU)/day/rat, respectively) for 8 weeks. In rats fed a high-fat diet, oral administration of $2.4{\times}10^9CFU/day$ of the L. plantarum mixture significantly reduced body weight gain as well as weights of liver and epididymal fat. Leptin levels in sera were significantly reduced by oral administration of $2.4{\times}10^9CFU/day$ of the L. plantarum mixture. The L. plantarum mixture ($1.2{\times}10^9$ or $2.4{\times}10^9CFU/day$) also reduced the concentrations of total cholesterol and LDL-cholesterol in sera when it administered orally. Further, the L. plantarum mixture significantly reduced the atherogenic index and cardiac risk factor. In addition, oral administration of $2.4{\times}10^9CFU/day$ of the L. plantarum mixture markedly reduced levels of total lipids, triglycerides, and total cholesterol in the liver. The results of this study indicate that the L. plantarum mixture may exhibit anti-obesity and cholesterol-lowering effects, which suggest that the L. plantarum mixture has the potential to be a probiotic in the management of obesity and hypercholesterolemia.

Activated Carbon-Photocatalytic Hybrid System for the Treatment of the VOC in the Exhaust Gas from Painting Process (도장공정 배기가스 내 VOC 처리를 위한 활성탄-광촉매 복합시스템)

  • Lee, Chan;Cha, Sang-Won;Lee, Tae-Kyu
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.133-139
    • /
    • 2005
  • An activated carbon-photo catalysis hybrid system is proposed for the treatment of VOC produced from paint booth. and its VOC removal performance is experimentally evaluated. Activated carbon tower is designed on the basis of the adsorption characteristics of toluene. Photocatalytic system is designed as the series of $TiO_2/SiO\_2$ fluidized bed reactor and $TiO_2$-coated filters. The present activated carbon-photo catalysis hybrid system shows the VOC removal efficiency within $75\~100\%$ under different VOC species and concentrations.

Energy-Connectivity Tradeoff through Topology Control in Wireless Ad Hoc Networks

  • Xu, Mengmeng;Yang, Qinghai;Kwak, Kyung Sup
    • ETRI Journal
    • /
    • v.39 no.1
    • /
    • pp.30-40
    • /
    • 2017
  • In this study, we investigate topology control as a means of obtaining the best possible compromise between the conflicting requirements of reducing energy consumption and improving network connectivity. A topology design algorithm capable of producing network topologies that minimize energy consumption under a minimum-connectivity constraint is presented. To this end, we define a new topology metric, called connectivity efficiency, which is a function of both algebraic connectivity and the transmit power level. Based on this metric, links that require a high transmit power but only contribute to a small fraction of the network connectivity are chosen to be removed. A connectivity-efficiency-based topology control (CETC) algorithm then assigns a transmit power level to each node. The network topology derived by the proposed CETC heuristic algorithm is shown to attain a better tradeoff between energy consumption and network connectivity than existing algorithms. Simulation results demonstrate the efficiency of the CECT algorithm.

A report of 7 unrecorded bacterial species isolated from several Jeju soil samples in 2016

  • Kim, Ju-Young;Jang, Jun Hwee;Maeng, Soohyun;Kang, Myung-Suk;Kim, Myung Kyum
    • Journal of Species Research
    • /
    • v.7 no.2
    • /
    • pp.151-160
    • /
    • 2018
  • Seven bacterial strains, 15J4M-1, 15J13-8, 16MFM10, 15J1-8, SR1-5-4, 15J13-6, and 15J8-11 assigned to the phylum Actinobacteria, Bacteroidetes, and Firmicutes were isolated from soil samples collected from Jeju, Korea. Phylogenetic analysis based on 16S rRNA gene sequence revealed that strains 15J4M-1, 15J13-8, 16MFM10, 15J1-8, SR1-5-4, 15J13-6, and 15J8-11 were most closely related to Bacillus selenatarsenatis $SF-1^T$ (with 99.4% similarity), Brevibacterium luteolum $CF87^T$ (99.5%), Carnobacterium iners CCUG $62000^T$ (99.6%), Exiguobacterium profundum $10C^T$ (99.3%), Larkinella insperata LMG $22510^T$ (99.3%), Pseudokineococcus lusitanus CECT $7306^T$ (99.4%), and Spirosoma endophyticum $EX36^T$ (99.3%), respectively. This is the first report of these seven species in Korea.

Biological Treatment of Two-Phase Olive Mill Wastewater (TPOMW, alpeorujo): Polyhydroxyalkanoates (PHAs) Production by Azotobacter Strains

  • Cerrone, Federico;Sanchez-Peinado, Maria Del Mar;Juarez-Jimenez, Belen;Gonzalez-Lopez, Jesus;Pozo, Clementina
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.3
    • /
    • pp.594-601
    • /
    • 2010
  • Azotobacter chroococcum H23 (CECT 4435), Azotobacter vinelandii UWD, and Azotobacter vinelandii (ATCC 12837), members of the family Pseudomonadaceae, were used to evaluate their capacity to grow and accumulate polyhydroxyalkanoates (PHAs) using two-phase olive mill wastewater (TPOMW, alpeorujo) diluted at different concentrations as the sole carbon source. The PHAs amounts (g/l) increased clearly when the TPOMW samples were previously digested under anaerobic conditions. The MNR analysis demonstrated that the bacterial strains formed only homopolymers containing $\beta$-hydroxybutyrate, either when grown in diluted TPOMW medium or diluted anaerobically digested TPOMW medium. COD values of the diluted anaerobically digested waste were measured before and after the aerobic PHA-storing phase, and a clear reduction (72%) was recorded after 72 h of incubation. The results obtained in this study suggest the perspectives for using these bacterial strains to produce PHAs from TPOMW, and in parallel, contribute efficiently to the bioremediation of this waste. This fact seems essential if bioplastics are to become competitive products.