• Title/Summary/Keyword: CD300

Search Result 251, Processing Time 0.029 seconds

Current development of microtip FEDs and carbon nanotube FEDs

  • Kim, Jong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.49-50
    • /
    • 2000
  • 5.2" microtip field emission displays (FEDs) with high voltage applications are fabricated. Nano-structural analysis on microtips is performed for the reliable operation of FEDs. Chemical compositions on the apex of microtips are fully analyzed. A charging mechanism on spacers is simulated and experimentally confirmed with micro-images. A gas-aging mechanism is also studied with integration step of FEDs. The brightness of more than 300 $cd/m^2$ is achieved. In addition, as a new concept, 9" color carbon nanotube FEDs (CNT-FEDs) are introduced using well-aligned carbon nanotubes on glass substrates by paste squeeze and surface treatment techniques. A number of carbon nanotubes, $5-10/{\mu}m2$, are uniformly distributed over a large area. The turn-on fields of 1 $V/{\mu}m$ and field emission currents of 1.5 mA at 3 $V/{\mu}m$ are acquired. Different mechanisms between microtip FEDs and CNT-FEDs are discussed.

  • PDF

Functional Analysis of the First Mannosyltransferase (PIG-M) involved in Glycosylphosphatidylinositol Synthesis in Plasmodium falciparum

  • Kim, Youn Uck;Hong, Yeongjin
    • Molecules and Cells
    • /
    • v.24 no.2
    • /
    • pp.294-300
    • /
    • 2007
  • The mammalian glycosylphosphatidylinositol (GPI) anchor consists of three mannoses attached to acylated GlcN-(acyl)PI to form $Man_3$-GlcN-(acyl)PI. The first of the three mannose groups is attached to an intermediate to generate Man-GlcN-(acyl)PI by the first mannosyltransferase (GPI-MT-I). Mammalian and protozoan GPI-MT-I have different substrate specificities. PIG-M encodes the mammalial GPI-MT-I which has 423 amino acids and multiple transmembrane domains. In this work we cloned PIG-M homologues from humans, Plasmodium falciparum (PfPIG-M), and Saccharomyces cerevisiae (GPI14), to test whether they could complement GPI-MT-I-deficient mammalian cells, since this biosynthetic step is likely to be a good target for selective screening of inhibitors against many pathogenic organisms. PfPIG-M partially restored cell surface expression of the GPI-anchored protein CD59 in PIG-M deficient mammalian cells, and first mannose transfer activity in vitro; however, this was not the case for GPI14.

Emission Properties of P-ELD by Thickness of Phosphor and Insulating layer (절연층 두께 변화에 따른 분산형 ELD의 발광특성)

  • 박수길;조성렬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.520-524
    • /
    • 1999
  • Light-emitting diode(LEDs), diode arrays, and phosphor display panels are finding increased use in a variety of commercial applications. Present and anticipated application of these devices include solid state indicator and display systems. In this work, Phosphor based on ZnS:Cu are used. Relation by luminance with the thickness of insulating layer and phosphor layer are discussed. Increased thickness of insulating layer are stable on voltage to 300V. By considering thickness and voltage, optimal structure and thickness are investigated. In order to maximize even surface emission, various sieving processes are introduced. 150cd/m$^2$ luminance by various wave intensity are investigated in stable voltage and frequency.

  • PDF

Study on Fluid Flow in Rectangular Duct past $90^{\circ}$ Mitered Elbow (사각덕트내 직각엘보우를 지난 유체유동에 관한 연구)

  • 윤영환;배택희;박원구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.670-678
    • /
    • 2002
  • Fluid flow in a rectangular duct with $90^{\circ}$ mitered elbow is measured by 5W laser doppler velocity meter. The fluid flow is also computed by commercial software of STAR-CD for comparison between measured and computed velocity profiles in the duct. Reynolds numbers for the comparison are 1,608 and 11,751 based on mean velocity and hydraulic diameter of the duct. First, the fluid flow of Reynolds number equal to 1,608 is predicted by assumptions of both laminar and turbulent models. But, even though the Reynolds number is less than 2,300~3,000, the computation by turbulent model is closed to the experimental data than that by laminar model. Second, the computation for Reynolds number of 11,751 by turbulent model also predicted the experimental data satisfactorily.

Interaction between Norfolxacin and Single Stranded DNA

  • 여정아;조태섭;Kim, Seog K.;문형랑;준길자;남원우
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.4
    • /
    • pp.449-457
    • /
    • 1998
  • We compared various spectroscopic properties of a norfloxacin-single stranded DNA complex with those of norfloxacin-double stranded DNA complex. Norfloxacin binds to both double-and single stranded DNA, and we observed the following spectroscopic changes for both complexes: hypochromism in the norfloxacin absorption region in the absorption spectrum, the characteristic induced CD spectrum consisting of a weak positive band at 323 nm and a strong positive band at 280-300 nm followed by a negative band in the 260 nm region, a strong decrease in the fluorescence intensity and a red-shift in the fluorescence emission spectrum, and shorter fluorescence decay times. These results indicate that the environments of the bound norfloxacin in both DNAs are similar, although the equilibrium constant of the norfloxacin-single stranded DNA was twice as high as the norfloxacin-double stranded DNA complex. Both complexes were thermodynamically favored with similar negative Δ$G^o$. Negative Δ$H^o$ terms contribute to these spontaneous reactions; Δ$S^o$ term was unfavorable.

Adsorption Characteristics of Cadmium ions from Aqueous Solution using by-product of Brewing (주정오니를 활용한 수중의 카드뮴(Cd) 흡착 특성)

  • Kim, Min-Su;Ham, Kwang-Joon;Ok, Yong-Sik;Gang, Seon-Hong
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.2
    • /
    • pp.152-158
    • /
    • 2010
  • Biosorption is considered to be an alternative method to replace the present adsorbent systems for the treatment of metal contaminated wastewater. In this study, by-product which was abandoned from brewing factory was used to remove metal component in aqueous solution. The experimental results showed that the range of the removal efficiency is 60~91% and adsorption equilibrium was reached in about 3 hr. FT-IR and stereo microscope has been used to observe the surface conditions and changes in functional groups by calcination. At the end of elution, the amount of nitrogen and phosphorus in water was increased 11 and 7 times compare raw sample to calcinated samples. The Langmuir isotherm adequately described the adsorption of waste materials and the maximum adsorption capacity was 28.17 mg/g for Cd. The overall results suggested that waste material might can be used for biosorption of Cd.

Restorative effects of Rg3-enriched Korean Red Ginseng and Persicaria tinctoria extract on oxazolone-induced ulcerative colitis in mice

  • Ullah, H.M. Arif;Saba, Evelyn;Lee, Yuan Yee;Hong, Seung-Bok;Hyun, Sun-Hee;Kwak, Yi-Seong;Park, Chae-Kyu;Kim, Sung Dae;Rhee, Man Hee
    • Journal of Ginseng Research
    • /
    • v.46 no.5
    • /
    • pp.628-635
    • /
    • 2022
  • Background: Ulcerative colitis (UC) is the large intestine disease that results in chronic inflammation and ulcers in the colon. Rg3-enriched Korean Red Ginseng extract (Rg3-RGE) is known for its pharmacological activities. Persicaria tinctoria (PT) is also used in the treatment of various inflammatory diseases. The aim of this study is to investigate the attenuating effects of Rg3-RGE with PT on oxazolone (OXA)-induced UC in mice. Methods: A total of six groups of mice including control group, OXA (as model group, 1.5%) group, sulfasalazine (75 mg/kg) group, Rg3-RGE (20 mg/kg) group, PT (300 mg/kg) group, and Rg3-RGE (10 mg/kg) with PT (150 mg/kg) group. Data on the colon length, body weight, disease activity index (DAI), histological changes, nitric oxide (NO) assay, Real-time PCR of inflammatory factors, ELISA of inflammatory factors, Western blot, and flow cytometry analysis were obtained. Results: Overall, the combination treatment of Rg3-RGE and PT significantly improved the colon length and body weight and decreased the DAI in mice compared with the treatment with OXA. Additionally, the histological injury was also reduced by the combination treatment. Moreover, the NO production level and inflammatory mediators and cytokines were significantly downregulated in the Rg3-RGE with the PT group compared with the model group. Also, NLR family pyrin domain containing 3 (NLRP3) inflammasome and nuclear factor kappa B (NF-𝛋B) were suppressed in the combination treatment group compared with the OXA group. Furthermore, the number of immune cell subtypes of CD4+ T-helper cells, CD19+ B-cells, and CD4+ and CD25+ regulatory T-cells (Tregs) was improved in the Rg3-RGE with the PT group compared with the OXA group. Conclusion: Overall, the mixture of Rg3-RGE and PT is an effective therapeutic treatment for UC.

Development of the Compressed Packer Grouting Device for Preventing the Inflow of Polluted Groundwater (오염지하수 유입방지를 위한 압축패커 그라우팅 장치 개발)

  • Cho, Heuy-Nam;Choi, Sang-Il
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.433-439
    • /
    • 2009
  • The compressed packer device is designed to improve the underground contamination prevention facilities of ground water wells. As for the device, the installation is simple because of the safety lock device and the compression of the casing are simple the installation is simple. There is no leakage of ground water because the pressure resistance with $4.5\;kg/cm^2$ makes it equipped with the watertightness The single casing is installed and the reaming for grouting is possible with 300 mm excavation so that installation cost can be saved. Silicon rubber is used for the compressed packer so that the extension rate is 590%. In terms of environmental pollution, it is an environmental friendly product which does not contain harmful ingredients such as Pb, Cd, and phenol. below the standard or undetectable level Furthermore, the installation costs are 35 to 62% or lower than the conventional grouting construction method and are 87% or lower than the expansion packer construction method, the new environmental technology No.47 Also, the device is designed to meet the relevant regulations such as Rules on Preserving the Ground Water Quality, The Standard on Jeju Island Ground Water Development and Facility Installation and Management, and The Plan and Guideline on Operating and Managing the Small-Scale Tap Water Facilities of Ministry of Environment and Ministry of Food, Agriculture, Forestry and Fisheries.

Process development for food waste composting (음식물 쓰레기 퇴비화 공정 개발)

  • Song, Oh-Yong;Jung, Kwang-Yong;Jeong, Jun-Young;Yang, Chang-Ok
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.321-326
    • /
    • 1999
  • This study was performed to evaluate the quality of produced compost and to analyse the change of a component during the reduction compost according to the input volume. The volume of pilot scale used in this study was about 300㎥. The pile of 2m width, 20m length and 1.2m height was constructed. Woodchip was used as bulking agent to enhance pore volume of composting bay and to control water content of food waste in starting time. Food waste was turned using a mechanical tumer twice a day. The result are as follows : In these cases of input volume of $2m^3$ and $3.5m^3$, temperature of composting pile was maintained over $60^{\circ}C$ and water content was 43.6% and 47.2%, respectively. It was proved that microorganisms activity was maintained high in each input volume. After operation of step 1 and step 2, pH and organic matter in the final compost were 6.2, 6.6 and 84.3%, 79.6%, respectively. Cation concentration such as $K_2O,$ CaO and NaCl was accumulated in the compost during the composting period. NaCl concentration in the final compost was 4.62%, 4.92%, respectively. Hence, If was recommended that this compost should be applied to others expect agricultural area or mixed with a low concentration other compost. In the steps 1, input volume of $2m^3$, heavy metal concentration of Pb, Cu, Cr, Ni. Cd were 37.82㎎/㎏, 56.87㎎/㎏, 9.8㎎/㎏. 22.21㎎/㎏ and 3.69㎎/㎏, and 44.55㎎/㎏, 95.54㎎/㎏, 12.22㎎/㎏, 24.94㎎/㎏, and 3.86㎎/㎏ in the step 2.

  • PDF

Fabrication and Characterization of Polymer Light Emitting Diodes by Using PFO/PFO:MEH-PPV Double Emitting Layer (PFO/PFO:MEH-PPV 이중 발광층을 이용한 고분자 유기발광다이오드의 제작과 특성 연구)

  • Chang, Young-Chul;Shin, Sang-Baie
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.23-28
    • /
    • 2008
  • To improve the external quantum efficiency by means of the optimization of the polymer light emitting diodes(PLEDs) structure, the PLED with ITO/PEDOT:PSS/(PFO)/PFO:MEH-PPV/LiF/Al structure were fabricated and investigated the electrical and optical properties for the prepared devices. ITO(indium tin oxide) and PEDOT:PSS [poly (3,4-ethylenedioxythiophene): poly(styrene sulfolnate)] were used as transparent anode film and hole transport materials, respectively. PFO[poly(9,9-dioctylfluorene)] and MEHPPV[poly(2-methoxy-5(2-ethylhe xoxy)-1,4-phenylenevinyle)] were used as the light emitting host and dopant materials. The doping concentration of MEH-PPV was 9wt% with thickness of about $400{\AA}$. We investigated the dependence of the PFO thickness ranging from $200{\AA}$ to $300{\AA}$ on the electrical, optical properties of PLEDs. Among prepared PLED devices with different PFO thicknesses, the highest value of the luminance was obtained for the PLED device with $250{\AA}$ in thickness. As a result, the current density and luminance ware found to be about $400mA/cm^2$ and $1500cd/m^2$ at 13V, respectively. In addition, the luminance and current efficiency of PLED device with double emitting layer (PFO/PFO:MEH-PPV) were improved about 3 times compared with the one with single emitting layer (PFO:MEH-PPV).

  • PDF