• Title/Summary/Keyword: CD test

Search Result 619, Processing Time 0.036 seconds

A study for CD stud welding of Magnesium alloy for electric device case (전자기기 케이스를 위한 마그네슘 판재 스터드 용접 기술에 관한 연구)

  • Lee, Mok-Yeong;Ryu, Chung-Seon;Jang, Ung-Seong;Choe, Sang-Un
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.53-56
    • /
    • 2007
  • Magnesium sheet used in electrical device due to mobility and EMF shielding characteristics. Magnesium case by press forming was advantageous compare with conventional die casting process, because of its thin gauge of wall and surface quality. But it need to makes the boss to fix inner part or assemble the case. CD stud welding was effective way for joining the boss to the thin gauge case of the electrical devices. In this study, we investigated the performances of the magnesium boss welder To measure the process parameters such as the force and the weld current, we design the monitoring system for CD stud welding. We test the characteristics of CD stud welding for AZ31 sheets at some variables. Finally we select the optimum welding range of magnesium sheets in CD stud welding process.

  • PDF

A Study on Fire Spread and Evacuation Risk of Conduit Combustion in Ceiling Hiding Place (천장 은폐장소 전선관 연소에 따른 화재확산 및 피난 위험도에 관한 연구)

  • Park, Kwang-Muk;Jeon, Jae-Kam;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.55-65
    • /
    • 2020
  • In this study, the ISO 5660 and ISO 5659 combustion tests were conducted with synthetic resin conduits (CD, VE) and metal conduit (ST) used for wiring work in electrical facilities, which can be installed in ceiling concealed places. Then, fire spreading and evacuation risks were analyzed based on the measured data. In the ISO 5660 test, CD of 120.5 MJ/㎡, VE of 81.9 MJ/㎡, and ST of 4.9 MJ/㎡ were measured. In the ISO 5659 test, the CD 1320, VE 731, and ST 102 were measured, and then the maximum smoke densities were measured for CD 605 s, VE 740 s, and ST 1,200 s. In terms of fire spreading and evacuation risk, the CD conduit, VE conduit, and ST conduit were in order. In the fire spreading risk analysis, total heat emission was calculated as 4,820 MJ/㎡, 4,267 MJ/㎡, and 196 MJ/㎡ for CD, VE, and ST, respectively. Evacuation risk analysis shows at transmittance of 89%, CD is 127 s, VE is 35 s, and ST is 969 s. At transmittance of 79%, representing almost invisible concentration, CD is 157 s and VE is 50 s. The CD and VE conduits had a high fire spreading and evacuation risks, while the ST conduit had little effect on fire spreading and evacuation risk.

Development of a Test Strip Reader for a Lateral Flow Membrane-based Immunochromatographic Assay

  • Park, Je-Kyun;Kim, Suhyeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.127-131
    • /
    • 2004
  • A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochromatographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15mm. The performance of the strip reader was tested by analysis of HBV(hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample.

Development and Application of a Health Belief Model Based Nutrition Education Program for Day Care Center Children (건강신념 모델에 근거한 보육시설 유아대상 영양교육 프로그램 개발 및 적용)

  • Sin Eun-Kyung;Lee Yeon-Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.4
    • /
    • pp.488-501
    • /
    • 2006
  • The purpose of this study was to develop various nutrition education materials, including an animated CD, for day care center children and their teachers and in order to apply the nutrition education programs systematically. We evaluated the effect of the nutrition education programs on nutrition knowledge in the first year, and the effect of the nutrition education programs on nutrition knowledge, food attitudes and eating behaviors in the second year in day care center children. In the first year, nutrition education foundational materials, such as the animated CD-ROM, videotape, textbook, panels, posters, slogans, leaflets, picture disks, hand puppets, stickers for compensation and poster boards were developed. The subjects were 537 children (286 boys,251 girls) aged four to six years. In the second year, nutrition education materials, such as the animated CD-ROM and textbook were developed. The nutrition education group included 368 children (177 boys 191 girls) aged four to six years, and the comparison group consisted of 108 children (54 boys,54 girls) Regarding the nutrition knowledge test results in the first year, the pre-test mean of children was 6.82, however, the post-test mean was 11.35 and showed a significant increase (p < 0.001). Regarding the nutrition knowledge test and the food attitude test results in the second yew, the nutrition education group had significantly higher scores than the comparison group in a post-test (p < 0.001). For the eating behavior test results, the post-test means between the comparison group and the nutrition education group were not significant. The test results show that several months of nutrition education is not enough to improve eating behaviors. As a result, nutrition education has improved nutrition knowledge and food attitudes in day care center children but short-term nutrition education was not sufficient to induce a change in eating behaviors. To improve eating behaviors in day care center children, nutrition education programs must be applied to day care center children in addition to their Parents and Persistent education will have to be continued.

석회석을 활용한 광미와 폐석의 Cd, Cu, Pb 및 Zn의 제거

  • Ji Han-Gu;Jeong Myeong-Chae;Jeong Mun-Yeong;Choi Yeon-Wang;Lee Mun-Hyeon;Lee Jae-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.20-23
    • /
    • 2005
  • The objective of this study is to examine a stabilized efficiency of heavy metals including Cd, Cu, Pb and Zn using slaked lime. Tailings from the Janggun Pb-Zn mine, the second Yeonhwa Pb-Zn mine, the Jisi Au-Ag mine and the Sangdong W mine were sampled and measured heavy metal concentrations contents using AAS as various extraction methods. During 156 hours, column test were undertaken to evaluate the possibility of stabilization by slaked lime. The result shows that $Ca(OH)_2$ has a good efficiency in heavy metal stabilization, especially at the Jisi mine with stabilized efficiencies of 97%(Cd), 99%(Cu), 86%(Pb) and 99%(Zn), respectively.

  • PDF

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

Electrical Properties and Reliability of the Photo-conductive CdS Thin Films for Flexible Opto-electronic Device Applications (유연성 광전도 CdS 박막의 증착조건에 따른 전기적 특성 및 신뢰성 평가 연구)

  • Hur, Sung-Gi;Cho, Hyun-Jin;Park, Kyoung-Woo;Ahn, Jun-Ku;Yoon, Soon-Gil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1023-1027
    • /
    • 2009
  • Cadmium sulfide (CdS) thin film for flexible optical device applications were prepared at $H_2/(Ar+H_2)$ flow ratios on polyethersulfon (PES) flexible polymer substrates at room temperature by radio frequency magnetron sputtering technique. The CdS thin films deposited at room temperature showed a (002) preferred orientation and the smooth surface morphologies. Films deposited at a hydrogen flow ratio of 25% exhibited a photo- and dark-sheet resistance of about 50 and $2.7\;{\times}\;10^5\;{\Omega}/square$, respectively. From the result of the bending test, CdS films exhibit a strong adhesion with the PES polymer substrates and the $Al_2O_3$ passivation layer deposited on the CdS films only shows an increase of the resistance of 8.4% after exposure for 120 h in air atmosphere.

Electrical Properties and Reliability of CdS Thin Film Deposited by R.F. Sputtering (유연성 기판위에 스퍼터링 방법으로 증착한 CdS 박막의 전기적 특성 및 신뢰성 평가)

  • Hur, Sung-Gi;Hwang, Mi-Na;Ahn, Jun-Ku;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.26-26
    • /
    • 2010
  • Cadmium sulfide (CdS) thin film for flexible optical device applications were prepared at $H_2(Ar+H_2)$ flow ratios on polyethersulfon(PES) flexible polymer substrates at room temperature by radio frequency magnetron sputtering technique. The CdS thin films deposited at room temperature showed a (002) preferred orientation and the smooth surface morphologies. Films deposited at a hydrogen flow ratio of 25% exhibited a photo- and dark-sheet resistance of about 50 and $2.7{\times}10^5{\Omega}$/square, respectively. From the result of the bending test, CdS films exhibit a strong adhesion with the PES polymer substrates and the $Al_2O_3$ passivation layer deposited on the CdS films only shows an increase of the resistance of 8.4% after exposure for 120 h in air atmosphere.

  • PDF

Anti-HER-2×anti-CD3 Bi-specific Antibodies Inhibit Growth of HCT-116 Colorectal Carcinoma Cells in Vitro and in Vivo

  • Ren, Hui;Li, Jun;Liu, Jing-Jing;Guo, Hui-Ling;Jiang, Tao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2795-2798
    • /
    • 2012
  • Objective: This study is conducted to evaluate the effects of anti-HER-2${\times}$anti-CD3 bi-specific antibodies(BsAb) on HER-2/neuover-expressing human colorectal carcinoma cells. Methods: Growth was assessed by MTT assays after exposure of HCT-116 cells to Herceptin, anti-CD3 and BsAb antibodies. Immunocytochemistry was applied to test the HER-2 level of HCT-116. In a nude mouse model, HER-2${\times}$CD3 BsAb was combined with effector cells (peripheral blood lymph cells from normal human being) for observations on in Vivo growth of tumors. Results: Compared with the control group, using effector cells combined with anti-CD3 McAb, Herceptin or HER2${\times}$CD3 BsAb, tumor cell growth in vitro and in vivo was significantly inhibited (P<0.05), most remarkably in the HER2${\times}$CD3 BsAb case. The growth of xenografts with HER2${\times}$CD3 BsAb combined with effector cells was also significantly inhibited when compared with the anti-CD3 McAb or Herceptin groups (P<0.05). Conclusion: HER-2/neu might be a useful target for immunotherapy in colorectal carcinoma, anti-HER2${\times}$anti-CD3 BsAb exerting clear anti-tumor effects.

Formation of Ohmic Contact in P-Type CdTe Using Cu2 Te Electrode and Its Effect on the Photovoltaic Properties of CdTe Solar Cells (Cu2Te 배면 전극을 이용한 p-type CdTe 태양전지의 ohmic contact 형성 및 CdTe 태양전지의 광전압 특성)

  • Kim, Ki-Hwan;Yun, Jae-Ho;Lee, Doo-Youl;Ahn, Byung-Tae
    • Korean Journal of Materials Research
    • /
    • v.12 no.12
    • /
    • pp.918-923
    • /
    • 2002
  • In this work, CdTe films were deposited on CdS/ITO/glass substrate by a close spaced sublimation (CSS) method. A $Cu_2$Te layer was deposited on the CdTe film by evaporating $Cu_2$Te powder. Then the samples were annealed for p+ ohmic contact. TEM and XRD analysis showed that $CdTe/Cu_2$Te interface exhibited different forms with various annealing temperature. A good p+ ohmic contact was achieved when the annealing temperature was between $180^{\circ}C$ to $200^{\circ}C$. Best cell efficiency of 12.34% was obtained when post annealing temperature was $200^{\circ}C$ for 5 min. Thermal stress test of the CdS/CdTe cells with carbon back contact showed that the $Cu_2$Te contact was stable at $50^{\circ}C$ in $N_2$ and was slowly degraded at $100^{\circ}C$ in $N_2$. In comparison to the conventional carbon contact, the $Cu_2$Te contact showed a better thermal stability.