• Title/Summary/Keyword: CCD

Search Result 2,851, Processing Time 0.035 seconds

Elastic properties of addition silicone interocclusal recording materials (부가중합형 실리콘 교합인기재의 탄성 특성)

  • Lee, Young-Ok;Kim, Kyoung-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.513-520
    • /
    • 2012
  • Objectives : In this study, contact angle and shore D hardness were measured, and a shark fin test was conducted after selecting five addition silicon(Blu-Mousse, BM; EXABITE II, EX; PERFECT, PF; Regisil$^{(R)}$ Rigid, RE; Silagum$^{(R)}$, SI) in order to figure out the properties of elastomeric interocclusal recording materials and reduce errors at interocclusal recording. 8) Methods : A contact angle was measured using a contact angle analyzer. After placing a drop of liquid on the surface of the specimens of interocclusal recording materials, a contact angle was photographed with a CCD camera on the equipment. In terms of a shark fin test, interocclusal recording materials were mixed for the time proposed by the manufacturer and inserted into the split ring of the Shark fin device. Twenty (20) seconds exactly, a metal rod was removed to make the materials slowly absorbed. Once they hardened, fin height was measured with a caliper after separating molds and trimming the specimens. The shore D hardness was measured with a shore D hardness tester(Model HPDSD, Hans Schmidt & Co. Gmbh, Germany) in sixty (60) minutes after fabricating specimens. In each experiment, five specimens, mean and standard deviation were calculated. A one-way ANOVA test was performed at the p>0.05 level of significance. In terms of correlation among the tests, Pearson correlation coefficient was estimated. For multiple comparison, Scheffe's test was carried out. Results : A contact angle was the highest in EX with $99.23^{\circ}$ (p<0.05) while the result of the shark fin test was the longest in RE with 5.45mm. SI was the lowest (0.27mm) with statistical significance. Among the interocclusal recording materials, significant difference was observed in terms of means (p<0.05). The shore D hardness was the highest in SI with 31.0 while RE was significantly low with 16.4 (p<0.05). Among the materials, statistically significant difference was observed in terms of means when compared to the rest materials (RE), BM, RE and SI (PF and EX) and the remaining materials (BM and SI) (p<0.05). In terms of correlations among the tests, a negative correlation occurred between shore D hardness and shark fin test(r=-0.823, p=0.000). Conclusions : According to the study above, it is necessary to understand the properties of interocclusal recording materials and consider contact angle, shark fin test and properties of shore D hardness to select appropriate materials.

Acceleration of Wound Healing and Collagen Deposition in Rat Skin by High Voltage Pulsed Current Stimulation (고전압맥동전류자극이 흰쥐 피부 창상치유와 교원질 축적에 미치는 효과)

  • Lee Jae-hyoung;Song In-young;Kim Jong-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to investigate the effect of high voltage pulsed current stimulation (HVPCS) on the healing rate of a dermal wound in a rat. We also determined the mechanism of promoting healing by HVPCS. Twenty male Sprague-Dawley rats were randomly divided into two group; HVPCS group (n=10) and control group (n=10). The HVPCS rats received electrical stimulation with a current intensity of 50 V at 100 pps for a duration of 30 minutes, while the control group was given the same treatment without electricity for a week. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with Masson's trichrome, hematoxylin and eosin (H&E). The fibroblasts and collagen density were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A Student t-test showed a significantly higher wound healing rate of the HVPCS group than control (t=-4.161, p<0.001). The fibroblasts in the HVPCS group were higher than in the control group (t=-4.921, p<0.001). The density of collagen in the HVPCS group was also higher than in the control group (t=-4.367, p<0.001). These results indicate that the HVPCS accelerated the rate of healing in dermal wound, and increased fibroblasts and collagen density in the regenerative dermis. These findings suggest that the HVPCS may activate fibroblasts by alteration of the electrical environment, and it may increase collagen synthesis in the regenerative dermal wound.

  • PDF

Optimization of Bleaching Conditions for Stain Removal in Japanese Hackberry (Celtis sinensis Persoon) Using Response Surface Methodology (반응표면분석법을 이용한 팽나무(Celtis sinensis Persoon)의 최적 변색제거조건 결정)

  • Kim, Sung-Hwan;Ra, Jong-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.191-198
    • /
    • 2010
  • This research was performed to investigate the effect of hydrogen peroxide on the stain removal in japanese hackberry. Response surface method (RSM) was used to optimize the bleaching conditions such as reaction temperature, reaction time and the concentration of hydrogen peroxide. Fifteen different bleaching conditions were selected according to $2^3$ factorial central composite design (CCD). The bleaching effect were evaluated by lightness differences of wood surface before and after the bleaching. The RSM model was determined and its $R^2$ values were 0.93, showing it well represented the bleaching effect. The most affecting factor on the stain removal was the concentration of hydrogen peroxide, followed by reaction time and reaction temperature. Second degree of concentration was proved to have an effect on the bleaching. Bleaching rates above 3% concentrations of hydrogen peroxide were tended to be slightly decreased, and low bleaching effect was found at $20^{\circ}C$. The determined RSM model may offer very practical ways to obtain the desired levels of bleaching because it offers multiple solutions.

Comparative analysis of fishing operation with the difference of deck layout of Korean coastal large trawler (우리나라 근해 대형트롤 어선의 갑판 레이아웃 차이에 따른 어로작업의 비교 분석)

  • Kim, Min-Son;Kang, Kyong-Mi;Lee, Ju-Hee;Shin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.311-326
    • /
    • 2013
  • For providing a basic data concerning with a fishing deck layout design of a trawler the authors conducted the video observations about the working activities of crews on the deck in the different layout of two Korean coastal large stern trawlers (gross tonnage: 139). The winch of the trawler-A was installed on the aft of the fishing deck and the trawler-B, on the forward of the fishing deck. The work and activities of the deck hands on both trawlers were observed using the CCD (charge coupled device) camera installed on each trawler's deck for one month from August 3, 2010. The video data was analyzed by the hierarchical task analysis (HTA) method. In results, numbers of tasks to require deck hands during the hauling net and the casting net were 25 and 28 for the trawler-A and 27 and 48 for the trawler-B, respectively. The working processes were represented a same in both of the trawlers. Location for controlling the deck machineries, the location installed trawl winch, kinds of deck machineries, crew's custom for using deck machineries were the factor affecting to the number of the task. In the case of the improvement suggested in the results is carried out, the reduction percentages of the number of task in the trawler-A and trawler-B were estimated as 24.5% and 51.3%, respectively. Through this study it was found that the quantitative analysis is possible for the work processes, work methods and the work contents in the trawler. Also the suggestion for improving the fishing deck layout design of the trawler was possible by finding out the factors increasing the number of tasks and removing the tasks. We expect that the results of this paper are used as a basic data for designing the layout of deck machineries in the trawler in the future.

Characteristics of bridge task in Korean coastal large trawler (우리나라 근해 대형트롤 어선의 선교업무 특성)

  • Kim, Min-Son;Shin, Hyeon-Ok;Lee, Ju-Hee;Hwang, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.301-310
    • /
    • 2013
  • To suggest a standard concerning with the arrangement of bridge equipment, the authors conducted the video observations with 3CCD (charge coupled device) cameras installed on the ceil of the bridge for monitoring the working activities of two bridge teams (the skipper/mate1 and the skipper/mate2) in a Korean coastal large trawler(gross tonnage: 139) for five days from July 30th. 2010 and analyzed of the data. Work elements coded by the work activities were input on the sheet of work analysis by the time unit of 1 sec according to the time occurred. A single work element among the work activities for every 5 minutes was denoted as the number of occurrence. The frequency of equipment usage was limited only in the usage of the equipment. In the case of the navigation and the towing net two ranks were integrated and analyzed. On the other hand, in the case of the casting net and the hauling net, two processes were integrated to as one and then analyzed separately as two ranks. As the results, 15 elements of work was carried out between two bridge teams for the observation; lookout, radar, GPS plotter, fish finder, net monitor, fishing deck, RPM indicator, rudder angle indicator, compass card, for maneuver; steering, ship speed control, trawl winch operation and external communications, paper works and others. It was found that the work load of the skipper per 5 minutes accordance with the navigation, the casting net, the towing net and the hauling net are 20.5 times, 11.9 times, 38.0 times and 9.5 times respectively, the mates are 65.2 times, 66.5 times, 85.7 times and 59.1 times respectively. The radar was shown the highest frequency of the equipment usage and the next was the fish finder, the GPS plotter and the external communications in the case of the navigation. In the case of the towing net the frequency of usage was high the ranking as the radar, the net monitor, the fish finder, the GPS plotter, the steering system and the external communications. In the case of the integrated process both of the casting and hauling net the trawl winch was shown the highest frequency to the skipper and the next was the GPS plotter and the radar, and the steering system was shown the highest frequency to the mate and the next was the radar, the ship speed control system, the GPS plotter, the net monitor and the fish finder.

Mechanism of $Ca^{2+}$ Regulation in Osteoblast-like Cells (골아세포내 $Ca^{2+}$ 활성도의 조절기전)

  • Park, Mi-Jung
    • Journal of Korean Biological Nursing Science
    • /
    • v.1 no.1
    • /
    • pp.25-41
    • /
    • 1999
  • Physiological activity of osteoblast including bone formation is known to be closely related to the increase of intracellular $Ca^{2+}$ activity($[Ca^{2+}]_i$) in osteoblast. $Ca^{2+}$ is an important intracellular messenger in diverse cellular functions, and regulation of its level is mediated by the transmembrane $Ca^{2+}$ movement via $Ca^{2+}$ channels, $Na^+-Ca^{2+}$ exchange, and by intracellular $Ca^{2+}$ movement through the intracellular stores. The purpose of this study is to investigate how the intracellular $Ca^{2+}$ is regulated in osteoblast-like cells(OLCs) by measuring $Ca^{2+}$ activity with cell imaging technique. OLCs were isolated from femur and tibia of neonatal rats, and cultured for 7 days. Cultured OLCs were loaded with a $Ca^{2+}$-sensitive fluorescent dye, Fura-2, and fluorescence images were monitored with a cooled CCD camera. The images were processed and analyzed with an image analyzing software. The results were as follows. (1) $[Ca^{2+}]_i$ of OLC decreased as the $Ca^{2+}$ concentration in the superfusing Tyrode solution was lowered. When $Na^+$ concentration in the superfusing solution was decreased, $[Ca^{2+}]_i$ increased.. These suggest that $Ca^{2+}$ flux occurs via the $Na^+-Ca^{2+}$ exchange mechanism. (2) When $Na^+$ in the superfusing solution was removed. a transient $Ca^{2+}$, increase($Ca^{2+}$ spike) was occasionally observed. However, $Ca^{2+}$ spike was not observed after adding 1 ${\mu}M$ thapsigargin. This implies that the generation of $Ca^{2+}$ spike is mediated by the release of $Ca^{2+}$ from endoplasmic reticulum(ER). (3) As the $Ca^{2+}$ concentration in the superfusing solution was raised, the frequency of 0mM $Na^+$-induced $Ca^{2+}$ spike increased, suggesting that $Ca^{2+}$-induced $Ca^{2+}$ release(CICR) mechanism exists. (4) After $[Ca^{2+}]_i$ was decreased with the superfusion of $Ca^{2+}$-free solution containing thapsigargin, the recovery of $[Ca^{2+}]_i$ with reperfusion of 2.5mM $Ca^{2+}$ solution transiently exceeded the control level, suggesting that the depletion of $Ca^{2+}$ in ER induces $Ca^{2+}$ influx from extracellular medium via store-operated $Ca^{2+}$ influx(SOCI) mechanism. (5) $[Ca^{2+}]_i$ was not affected by the superfusion of 25mM $K^+$ Tyrode solution. These results suggest that intracellular $Ca^{2+}$ activity in osteoblast is regulated by transmembrane $Ca^{2+}$ flux via $Na^+-Ca^{2+}$ exchange, $Ca^{2+}$ release from the internal store (ER) via $Ca^{2+}$-induced $Ca^{2+}$ release, and store-operated $Ca^{2+}$ influx across the cell membrane.

  • PDF

Intensity Compensation for Efficient Stereo Image Compression (효율적인 스테레오 영상 압축을 위한 밝기차 보상)

  • Jeon Youngtak;Jeon Byeungwoo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.101-112
    • /
    • 2005
  • As we perceive the world as 3-dimensional through our two eyes, we can extract 3-dimensional information from stereo images obtained from two or more cameras. Since stereo images have a large amount of data, with recent advances in digital video coding technology, efficient compression algorithms have been developed for stereo images. In order to compress stereo images and to obtain 3-D information such as depth, we find disparity vectors by using disparity estimation algorithm generally utilizing pixel differences between stereo pairs. However, it is not unusual to have stereo images having different intensity values for several reasons, such as incorrect control of the iris of each camera, disagreement of the foci of two cameras, orientation, position, and different characteristics of CCD (charge-coupled device) cameras, and so on. The intensity differences of stereo pairs often cause undesirable problems such as incorrect disparity vectors and consequent low coding efficiency. By compensating intensity differences between left and right images, we can obtain higher coding efficiency and hopefully reduce the perceptual burden of brain to combine different information incoming from two eyes. We propose several methods of intensity compensation such as local intensity compensation, global intensity compensation, and hierarchical intensity compensation as very simple and efficient preprocessing tool. Experimental results show that the proposed algerian provides significant improvement in coding efficiency.

Development of a Low-cost Monocular PSD Motion Capture System with Two Active Markers at Fixed Distance (일정간격의 두 능동마커를 이용한 저가형 단안 PSD 모션캡쳐 시스템 개발)

  • Seo, Pyeong-Won;Kim, Yu-Geon;Han, Chang-Ho;Ryu, Young-Kee;Oh, Choon-Suk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.61-71
    • /
    • 2009
  • In this paper, we propose a low-cost and compact motion capture system which enables to play motion games in PS2(Play Station 2). Recently, motion capture systems which are being used as a part in film producing and making games are too expensive and enormous systems. Now days, motion games using common USB camera are slow and have two-dimension recognition. But PSD sensor has a few good points, such as fast and low-cost. In recently year, 3D motion capture systems using 2D PSD (Position Sensitive Detector) optic sensor for motion capturing have been developed. One is Multi-PSD motion capture system applying stereo vision and another is Single-PSD motion capture system applying optical theory ship. But there are some problems to apply them to motion games. The Multi-PSD is high-cost and complicated because of using two more PSD Camera. It is so difficult to make markers having omni-direction equal intensity in Single-PSD. In this research, we propose a new theory that solves aforementioned problems. It can measure 3D coordination if separated two marker's intensity is equal to. We made a system based on this theory and experimented for performance capability. As a result, we were able to develop a motion capture system which is a single, low-cost, fast, compact, wide-angle and an adaptable motion games. The developed system is expected to be useful in animation, movies and games.

An Efficient Dead Pixel Detection Algorithm Implementation for CMOS Image Sensor (CMOS 이미지 센서에서의 효율적인 불량화소 검출을 위한 알고리듬 및 하드웨어 설계)

  • An, Jee-Hoon;Shin, Seung-Gi;Lee, Won-Jae;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.55-62
    • /
    • 2007
  • This paper proposes a defective pixel detection algorithm and its hardware structure for CCD/CMOS image sensor. In previous algorithms, the characteristics of image have not been considered. Also, some algorithms need quite a time to detect defective pixels. In order to make up for those disadvantages, the proposed defective pixel detection method detects defective pixels efficiently by considering the edges in the image and verifies them using several frames while checking scene-changes. Whenever scene-change is occurred, potentially defective pixels are checked and confirmed whether it is defective or not. Test results showed that the correct detection rate in a frame was increased 6% and the defective pixel verification time was decreased 60%. The proposed algorithm was implemented with verilog HDL. The edge indicator in color interpolation block was reused. Total logic gate count was 5.4k using 0.25um CMOS standard cell library.

DEVELOPMENT OF FILTERING SYSTEM OF LASER FLUORESCENCE FOR IMPROVEMENT OF THE DIAGNOSTIC SENSITIVITY FOR DENTAL CARIES (레이저 형광법의 치아우식증 진단감도를 증진시키기 위한 필터링 시스템 개발)

  • Lee, Sang-Ho;Park, Jong-Whi;Kook, Jung-Ki;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.189-195
    • /
    • 2003
  • The objective of this study is to improve the optical sensitivity of laser fluorescence for detection of incipient enamel caries. An incipient carious lesion was formed in various stages by placing an enamel specimen of a bovine tooth in STPP demineralization solution. After measuring the optical density of the lesion surface by laser fluorescence induced by argon laser and various alter of yellow(500-520nm), amber(520-540nm), orange(540-560nm), and red(560-580nm), the specimen was cut vertically to measure the depth of the lesion using a polarizing microscope. SAS statistical program was used to analyze the relationship between the optical density of the lesion suface and the depth of the lesion. The results were as follows: 1. The optical density of early carious lesion, measured by laser fluorescence with amber and orange filter, and lesion depth observed by polarizing microscope, were increased as demineralization time increased. 2. The correlation coefficient between optical density of the lesion surface and the histological depth of the lesion was the highest in orange filter(r=0.49), followed by amber(r=0.32), yellow(r=0.13) and red(0.01). 3. Regression analysis showed that the most linear relationship between the optical density and the lesion depth was existed in orange filter group. In regard above results, laser fluorescence could be considered to be reliable for optical diagnosis of dental caries.

  • PDF