• Title/Summary/Keyword: CCD

Search Result 2,849, Processing Time 0.03 seconds

A Comparison of Effectiveness of Gracey Curet and Ultrasonic Curet on Subgingival Scaling and Root Planning (치은 연하 치석 제거와 치근면 활택술시 Gracey curet과 Ultrasonic curet의 치석 제거에 효과에 대한 비교 연구)

  • Chung, Suk-Hyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.257-269
    • /
    • 2001
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, Gracey curet and Ultrasonic curet were used on single rooted teeth to conduct subgingval scaling and root planning. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth were extracted from 14 patients being treated at department Periodontology Seoul Advantist dental hospital were used. Total 96 area(4 surface per teeth) were evaluated. 12 teeth treated with Gracey curet were used as the control group and the other 12 teeth treated with Ultrasonic curet were examined for experimental group. The 4 surface of the teeth(buccal, mesial, lingual or palatal, distal) were observed through the stereomicroscope and the images of the surface were captured and saved in CCD. The images were displayed on the monitor and the amount of calculus remained was evaluated by overlapping $10{\times}10$ grid pixel screen produced by Microsoft power point. The results evaluated were as follows 1. There was no statistically significant difference in residual calculus and tooth position following scaling and root planning of all group, but statistically significant correlation with residual calculus, probing depth, instruments and tooth surface. 2. There was statistically significant correlation between residual calculus and probing depth, but no statistically significant difference in residual calculus, tooth surface and tooth position on experimental(Ultrasonic curet) group. 3. There was no statistically significant difference in residual calculus according to the pre-treatment pocket depth and tooth position, but statistically significant correlation with tooth surface. The amount of residual calculus increase with mesial, distal, buccal and lingual(or palatal) surface on control(Gracey curet) group. 4. The Gracey showed better results than ultrasonic curet in mesial and distal surface, and there is significant difference. The results demonstrate that ultrasonic curet alone is inadequate for thorough subgingival debridement and suggest that Ultrasonic curet with Gracey curet should be more effective.

  • PDF

Effects of Light-Curing on the Immediate and Delayed Micro-Shear Bond Strength between Yttria-Tetragonal Zirconia Polycrystal Ceramics and Universal Adhesive

  • Lee, Yoon;Woo, Jung-Soo;Eo, Soo-Heang;Seo, Deog-Gyu
    • Journal of Korean Dental Science
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2015
  • Purpose: To evaluate the effect of light-curing on the immediate and delayed micro-shear bond strength (${\mu}SBS$) between yttria-tetragonal zirconia polycrystal (Y-TZP) ceramics and RelyX Ultimate when using Single Bond Universal (SBU). Materials and Methods: Y-TZP ceramic specimens were ground with #600-grit SiC paper. SBU was applied and RelyX Ultimate was mixed and placed on the Y-TZP surface. The specimens were divided into three groups depending on whether light curing was done after adhesive (SBU) and resin cement application: uncured after adhesive and uncured after resin cement application (UU); uncured after adhesive, but light cured after resin cement (UC); and light cured after adhesive and light cured resin cement (CC). The three groups were further divided depending on the timing of ${\mu}SBS$ testing: immediate at 24 hours (UUI, UCI, CCI) and delayed at 4 weeks (UUD, UCD, CCD). ${\mu}SBS$ was statistically analyzed using one-way ANOVA and Student-Newman-Keuls multiple comparison test (P<0.05). The surface of the fractured Y-TZP specimens was analyzed under a scanning electron microscope (SEM). Result: At 24 hours, ${\mu}SBS$ of UUI group ($8.60{\pm}2.06MPa$) was significantly lower than UCI group ($25.71{\pm}4.48MPa$) and CCI group ($29.54{\pm}3.62MPa$) (P<0.05). There was not any significant difference between UCI and CCI group (P>0.05). At 4 weeks, ${\mu}SBS$ of UUD group ($24.43{\pm}2.88MPa$) had significantly increased over time compared to UUI group (P<0.05). The SEM results showed mixed failure in UCI and CCI group, while UUI group showed adhesive failure. Conclusion: Light-curing of universal adhesive before or after application of RelyX Ultimate resin cement significantly improved the immediate ${\mu}SBS$ of resin cement to air-abrasion treated Y-TZP surface. After 4 weeks, the delayed ${\mu}SBS$ of the non-light curing group significantly improved to the level of light-cured groups.

Energy Minimization Model for Pattern Classification of the Movement Tracks (행동궤적의 패턴 분류를 위한 에너지 최소화 모델)

  • Kang, Jin-Sook;Kim, Jin-Sook;Cha, Eul-Young
    • The KIPS Transactions:PartB
    • /
    • v.11B no.3
    • /
    • pp.281-288
    • /
    • 2004
  • In order to extract and analyze complex features of the behavior of animals in response to external stimuli such as toxic chemicals, we implemented an adaptive computational method to characterize changes in the behavior of chironomids in response to treatment with the insecticide, diazinon. In this paper, we propose an energy minimization model to extract the features of response behavior of chironomids under toxic treatment, which is applied on the image of velocity vectors. It is based on the improved active contour model and the variations of the energy functional, which are produced by the evolving active contour. The movement tracks of individual chironomid larvae were continuously measured in 0.25 second intervals during the survey period of 4 days before and after the treatment. Velocity on each sample track at 0.25 second intervals was collected in 15-20 minute periods and was subsequently checked to effectively reveal behavioral states of the specimens tested. Active contour was formed around each collection of velocities to gradually evolve to find the optimal boundaries of velocity collections through processes of energy minimization. The active contour which is improved by T. Chan and L. Vese is used in this paper. The energy minimization model effectively revealed characteristic patterns of behavior for the treatment versus no treatment, and identified changes in behavioral states .is the time progressed.

Proximal caries detection using digital subtraction radiography in the artificial caries activity model (인공 치아우식 발생 모델에서 디지털 방사선 공제술을 이용한 인접면 치아우식증의 진단)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Young-Ho;Kim, Kyung-Sook;Jin, Hyun-Seok;Hong, Kyung-Won;Oh, Berm-Seok;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Materials and Methods: Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. Results: In artificial caries activity model, the range of lesional depth was $572-1,374{\mu}m$ and the range of lesional area was $36.95-138.52mm^2$. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. Conclusion: The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  • PDF

Performance Analysis of Screen Contents Coding Tools to Reduce Inter-Color Component Correlation (색 공간 내 중복 정보 감소를 위한 HEVC 스크린 콘텐츠 부호화 기법 성능 분석)

  • Kang, Je-Won
    • Journal of Broadcast Engineering
    • /
    • v.20 no.5
    • /
    • pp.687-696
    • /
    • 2015
  • JCT-VC (Joint Collaborative Team on Video Coding) continues developing HEVC/Screen Content Coding (HEVC/SCC) as an extension for efficiently coding screen content videos, including computer animations, graphics, and electrical documents, based on HEVC/Range extension (HEVC/RExt.). Color space conversion from RGB space being captured from CCD sensors is popular in natural video coding. However, the conversion is often undesired for screen contents because of a significant loss in perceptual quality. Therefore, several coding tools including cross-component prediction (CCP) and in-loop adaptive color space transform (ACST) have been developed for an efficient screen content video coding in order to reduce the redundancies between color spaces while maintaining the original color space. In this paper, we review the two coding tools, i.e., CCP and ACST exploiting the correlation in the RGB color space and conduct the performance analysis of the coding tools. In our simulation results, CCP and ACST provide 11.7% BD-rate saving and 16.4% BD-rate saving, respectively, while the two coding tools provide 18.2% BD-rate saving in total. Following this idea, if the two coding tools are exclusively selected, we provide 93% encoding measurement time with a 0.3% coding loss.

Velocity Field Measurement of Flow Inside SNOUT of Zinc Plating Process ( I ) (용융아연 도금공정에서의 SNOUT 내부 유동장 해석 ( I ))

  • Shin, Dae Sig;Choi, Jayho;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1265-1273
    • /
    • 1999
  • PIV(Particle Image Velocimetry) velocity field measurements inside the snout of a1/10 scale model of the Zn plating process were carried out at the strip speed $V_s=1.5m/s$. Aluminum powder particles ($1{\mu}m$) and atomized olive oil ($3{\mu}m$) were used as seeding particles to simulate the molten Zinc flow and deoxidization gas flow, respectively. A pulsed Nd:Yag laser and a $2K{\times}2K$ high-resolution CCD camera were synchronized for the PIV velocity field measurement. From flow visualization study, it is found that the liquid flow in the Zn pot is dominantly governed by the uprising flow caused by the rotating sink roll, with its effect on the steel strip inside the snout largely diminished by installing of the snout. The deoxidization gas flow in front of the strip inside the snout can be characterized by a large-scale vortex rotating clockwise direction formed by the moving strip. In the rear side of the strip, a counter-clockwise vortex is formed and some of the flow entrained by the moving strip impinges on the free surface of molten zinc. The liquid flow in front of the strip is governed by the flow entering the snout, caused by the spinning sink roll. Just below the free surface a counter-clockwise vortex is formed near the snout wall. The moving strip affects dominantly the flow behind the strip inside the snout, and large amount of the liquid flow follows the moving strip toward the sink roll. The thickness of the flow following the strip is very thin in the front side due to the uprising flow, however thick boundary layer is formed in the rear side of the strip. Its thickness is increased as moving downstream toward the sink roll. Inside the snout, the deoxidization gas flow above the free surface is much faster than the liquid flow in the zinc pot. Due to the larger influx of the flow following the moving strip in the rear side of the strip, higher percentage of imperfection can be anticipated on the rear surface of the strip.

Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

Statistical Optimization for Production of Carboxymethylcellulase from Rice Hulls by a Newly Isolated Marine Microorganism Bacillus licheniformis LBH-52 Using Response Surface Method (통계학적인 방법과 왕겨를 기질로 사용하여 해양에서 분리한 Bacillus licheniformis LBH-52 를 사용한 carboxymethylcellualse의 생산조건 최적화)

  • Kim, Hye-Jin;Gao, Wa;Chung, Chung-Han;Lee, Jin-Woo
    • Journal of Life Science
    • /
    • v.21 no.8
    • /
    • pp.1083-1093
    • /
    • 2011
  • A microorganism utilizing rice hulls as a substrate for the production of carboxymethylcellulase (CMCase) was isolated from seawater and identified as Bacillus lincheniformis by analyses of its 16S rDNA sequences. The optimal carbon and nitrogen sources for production of CMCase were found to be rice hulls and ammonium nitrate. The optimal conditions for cell growth and the production of CMCase by B. lincheniformis LBH-52 were investigated using the response surface method (RSM). The analysis of variance (ANOVA) of results from central composite design (CCD) indicated that a highly significant factor ("probe>F" less than 0.0001) for cell growth was rice hulls, whereas those for production of CMCase were rice hulls and initial pH of the medium. The optimal conditions of rice hulls, ammonium nitrate, initial pH, and temperature for cell growth extracted by Design Expert Software were 48.7 g/l, 1.8 g/l, 6.6, and 35.7$^{\circ}C$, respectively, whereas those for the production of CMCase were 43.2 g/l, 1.1 g/l, 6.8, and 35.7$^{\circ}C$. The maximal production of CMCase by B. lincheniformis LBH-52 from rice hulls under optimized conditions was 79.6 U/ml in a 7 l bioreactor. In this study, rice hulls and ammonium nitrate were developed to be substrates for the production of CMCase by a newly isolated marine microorganism, and the time for production of CMCase was reduced to 3 days using a bacterial strain with submerged fermentation.

Elastic properties of addition silicone interocclusal recording materials (부가중합형 실리콘 교합인기재의 탄성 특성)

  • Lee, Young-Ok;Kim, Kyoung-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.513-520
    • /
    • 2012
  • Objectives : In this study, contact angle and shore D hardness were measured, and a shark fin test was conducted after selecting five addition silicon(Blu-Mousse, BM; EXABITE II, EX; PERFECT, PF; Regisil$^{(R)}$ Rigid, RE; Silagum$^{(R)}$, SI) in order to figure out the properties of elastomeric interocclusal recording materials and reduce errors at interocclusal recording. 8) Methods : A contact angle was measured using a contact angle analyzer. After placing a drop of liquid on the surface of the specimens of interocclusal recording materials, a contact angle was photographed with a CCD camera on the equipment. In terms of a shark fin test, interocclusal recording materials were mixed for the time proposed by the manufacturer and inserted into the split ring of the Shark fin device. Twenty (20) seconds exactly, a metal rod was removed to make the materials slowly absorbed. Once they hardened, fin height was measured with a caliper after separating molds and trimming the specimens. The shore D hardness was measured with a shore D hardness tester(Model HPDSD, Hans Schmidt & Co. Gmbh, Germany) in sixty (60) minutes after fabricating specimens. In each experiment, five specimens, mean and standard deviation were calculated. A one-way ANOVA test was performed at the p>0.05 level of significance. In terms of correlation among the tests, Pearson correlation coefficient was estimated. For multiple comparison, Scheffe's test was carried out. Results : A contact angle was the highest in EX with $99.23^{\circ}$ (p<0.05) while the result of the shark fin test was the longest in RE with 5.45mm. SI was the lowest (0.27mm) with statistical significance. Among the interocclusal recording materials, significant difference was observed in terms of means (p<0.05). The shore D hardness was the highest in SI with 31.0 while RE was significantly low with 16.4 (p<0.05). Among the materials, statistically significant difference was observed in terms of means when compared to the rest materials (RE), BM, RE and SI (PF and EX) and the remaining materials (BM and SI) (p<0.05). In terms of correlations among the tests, a negative correlation occurred between shore D hardness and shark fin test(r=-0.823, p=0.000). Conclusions : According to the study above, it is necessary to understand the properties of interocclusal recording materials and consider contact angle, shark fin test and properties of shore D hardness to select appropriate materials.

Acceleration of Wound Healing and Collagen Deposition in Rat Skin by High Voltage Pulsed Current Stimulation (고전압맥동전류자극이 흰쥐 피부 창상치유와 교원질 축적에 미치는 효과)

  • Lee Jae-hyoung;Song In-young;Kim Jong-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to investigate the effect of high voltage pulsed current stimulation (HVPCS) on the healing rate of a dermal wound in a rat. We also determined the mechanism of promoting healing by HVPCS. Twenty male Sprague-Dawley rats were randomly divided into two group; HVPCS group (n=10) and control group (n=10). The HVPCS rats received electrical stimulation with a current intensity of 50 V at 100 pps for a duration of 30 minutes, while the control group was given the same treatment without electricity for a week. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with Masson's trichrome, hematoxylin and eosin (H&E). The fibroblasts and collagen density were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A Student t-test showed a significantly higher wound healing rate of the HVPCS group than control (t=-4.161, p<0.001). The fibroblasts in the HVPCS group were higher than in the control group (t=-4.921, p<0.001). The density of collagen in the HVPCS group was also higher than in the control group (t=-4.367, p<0.001). These results indicate that the HVPCS accelerated the rate of healing in dermal wound, and increased fibroblasts and collagen density in the regenerative dermis. These findings suggest that the HVPCS may activate fibroblasts by alteration of the electrical environment, and it may increase collagen synthesis in the regenerative dermal wound.

  • PDF