• Title/Summary/Keyword: CCD

Search Result 2,849, Processing Time 0.038 seconds

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

TIME-SERIES PHOTOMETRY OF VARIABLE STARS IN THE GLOBULAR CLUSTER NGC 288

  • Lee, Dong-Joo;Koo, Jae-Rim;Hong, Kyeongsoo;Kim, Seung-Lee;Lee, Jae Woo;Lee, Chung-Uk;Jeon, Young-Beom;Kim, Yun-Hak;Lim, Beomdu;Ryu, Yoon-Hyun;Cha, Sang-Mok;Lee, Yongseok;Kim, Dong-Jin;Park, Byeong-Gon;Kim, Chun-Hwey
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.6
    • /
    • pp.295-306
    • /
    • 2016
  • We present the results of BV time-series photometry of the globular cluster NGC 288. Observations were carried out to search for variable stars using the Korea Microlensing Telescope Network (KMTNet) 1.6-m telescopes and a 4k pre-science CCD camera during a test observation from August to December, 2014. We found a new SX Phe star and confirmed twelve previously known variable stars in NGC 288. For the semi-regular variable star V1, we newly determined a period of 37.3 days from light curves spanning 137 days. The light-curve solution of the eclipsing binary V10 indicates that the system is probably a detached system. The pulsation properties of nine SX Phe stars were examined by applying multiple frequency analysis to their light curves. We derived a new Period-Luminosity (P-L) relation, ${\langle}M_V{\rangle}=-2.476({\pm}0.300){\log}P-0.354({\pm}0.385)$, from six SX Phe stars showing the fundamental mode. Additionally, the period ratios of three SX Phe stars that probably have a double-radial mode were investigated; $P_{FO}/P_F=0.779$ for V5, $P_{TO}/P_{FO}=0.685$ for V9, $P_{SO}/P_{FO}=0.811$ for V11. This paper is the first contribution in a series assessing the detections and properties of variable stars in six southern globular clusters with the KMTNet system.

Observation of Dynamic Movement of Probing Pin on PCB Pad Using Electrical Reliability Test (인쇄회로 기판의 전기검사에서의 미세 탐침과 패드의 동적 거동 현상 관측)

  • Song, Seongmin;Cha, Gangil;Kim, Myungkyu;Jeon, Seungho;Yu, SangSeok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.245-251
    • /
    • 2015
  • In an electrical reliability test of a printed circuit board (PCB), the impact of the micro probing pins on the PCB needs to be checked to ascertain the quality of the circuit. In this study, the impact of the dynamic movement of the probing pin on the pad was observed. As a misaligned pin can exert horizontal force on the pad of the PCB, this study focused on the behavior of a misaligned probing pin. The parameters of observation were the circular and flat edges of the probing pin. The effects of the speed of movement, diameter, and the length of projection of the probing pin were also investigated. The results demonstrated that slippage angle is strongly affected by the shape of the edge of the probing pin, and that projection length is an important factor affecting pin slippage. In contrast, the speed of movement of the probing pin was able to double the slippage angle.

Automatic Classification Algorithm for Raw Materials using Mean Shift Clustering and Stepwise Region Merging in Color (컬러 영상에서 평균 이동 클러스터링과 단계별 영역 병합을 이용한 자동 원료 분류 알고리즘)

  • Kim, SangJun;Kwak, JoonYoung;Ko, ByoungChul
    • Journal of Broadcast Engineering
    • /
    • v.21 no.3
    • /
    • pp.425-435
    • /
    • 2016
  • In this paper, we propose a classification model by analyzing raw material images recorded using a color CCD camera to automatically classify good and defective agricultural products such as rice, coffee, and green tea, and raw materials. The current classifying agricultural products mainly depends on visual selection by skilled laborers. However, classification ability may drop owing to repeated labor for a long period of time. To resolve the problems of existing human dependant commercial products, we propose a vision based automatic raw material classification combining mean shift clustering and stepwise region merging algorithm. In this paper, the image is divided into N cluster regions by applying the mean-shift clustering algorithm to the foreground map image. Second, the representative regions among the N cluster regions are selected and stepwise region-merging method is applied to integrate similar cluster regions by comparing both color and positional proximity to neighboring regions. The merged raw material objects thereby are expressed in a 2D color distribution of RG, GB, and BR. Third, a threshold is used to detect good and defective products based on color distribution ellipse for merged material objects. From the results of carrying out an experiment with diverse raw material images using the proposed method, less artificial manipulation by the user is required compared to existing clustering and commercial methods, and classification accuracy on raw materials is improved.

DYNAMICAL SUBSTRUCTURES OF GALACTIC GLOBULAR CLUSTERS I. M5 (우리은하 구상성단들의 역학적 세부구조 I. M5)

  • Rhee, Jong-whan;Sohn, Young-Jong
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.3
    • /
    • pp.181-190
    • /
    • 2004
  • We use BV CCD images to study the dynamical substructure of the globular cluster M5. We investigate the radial variation of ellipticities and position angles using the stellar photometry and the IRAF ellipse task. We find that out to three times the half light radius $(r_h)$, the changes in ellipticities and position angles range in $0.05\~0.25$ and $75^{\circ}\~-75^{\circ}$, respectively. There are no significant discrepancy in the dynamical substructure beyond $r_h$ among the different giant populations. However, compared to the global dynamical substructure of M5, the inner $(<0.5r_h)$ substructure of the bright red giant and the horizontal branch populations show slightly different patterns. Especially, the discrepancy of the bright red giant population with respect to the global substructure, ranges up to 0.1 for the ellipticity and 1000 for the position angle.

Spectra Responsibility of Quantum Dot Doped Organic Liquid Scintillation Dosimeter for Radiation Therapy

  • Kim, Sung-woo;Cho, Byungchul;Cho, Sangeun;Im, Hyunsik;Hwang, Ui-jung;Lim, Young Kyoung;Cha, SeungNam;Jeong, Chiyoung;Song, Si Yeol;Lee, Sang-wook;Kwak, Jungwon
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.226-231
    • /
    • 2017
  • The aim is to investigate the spectra responsibilities of QD (Quantum Dot) for the innovation of new dosimetry application for therapeutic Megavoltage X-ray range. The unique electrical and optical properties of QD are expected to make it a good sensing material for dosimeter. This study shows the spectra responsibility of toluene based ZnCd QD and PPO (2.5-diphenyloxazol) mixed liquid scintillator. The QDs of 4 sizes corresponding to an emission wavelength (ZnCdSe/ZnS:$440{\pm}5nm$, ZnCdSeS:470, 500, $570{\pm}5nm$) were utilized. A liquid scintillator for control sample was made of toluene, PPO. The Composition of QD loaded scintillators are about 99 wt% Toluene as solvent, 1 wt% of PPO as primary scintillator and 0.05, 0.1, 0.2 and 0.4 wt% of QDs as solute. For the spectra responsibility of QD scintillation, they were irradiated for 30 second with 6 MV beam from a LINAC ($Infinity^{TM}$, Elekta). With the guidance of 1.0 mm core diameter optical fiber, scintillation spectrums were measured by a compact CCD spectrometer which could measure 200~1,000 nm wavelength range (CCS200, Thorlabs). We measured the spectra responsibilities of QD loaded organic liquid scintillators in two scintillation mechanisms. First was the direct transfer and second was using wave shifter. The emission peaks from the direct transfer were measured to be much smaller luminescent intensity than based on the wavelength shift from the PPO to QDs. The emission peak was shifted from PPO emission wavelength 380 nm to each emission wavelength of loaded QD. In both mechanisms, 500 nm QD loaded samples were observed to radiate in the highest luminescence intensity. We observed the spectra responsibility of QD doped toluene based liquid scintillator in order to innovate QD dosimetry applicator. The liquid scintillator loading 0.2 wt% of 500 nm emission wavelength QD has most superior responsibility at 6 MV photon beam. In this study we observed the spectra responsibilities for therapeutic X-ray range. It would be the first step of innovating new radiation dosimetric methods for radiation treatment.

The Effects of Various Extracellular Matrices on Motility of Cultured MC3T3-E1 Cell (다양한 세포외기질이 배양 골아세포의 이동에 미치는 영향)

  • Park, Beyoung Yun;Seo, Sang Woo;Lee, Won Jai;Ryu, Chang Woo;Rah, Dong Kyun;Son, Hyun Joo;Park, Jong Chul
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.143-148
    • /
    • 2005
  • Chemotactic migration of bone forming cell, osteoblast, is an important event during bone formation, bone remodeling, and fracture healing. Migration of cells is mediated by adhesion receptors, such as integrins, that link the cell to extracellular matrix ligands, type I collagen, fibronectin, laminin and depend on interaction between integrin and extracellular ligand. Our study was designed to investigate the effect of extracellular matrix like fibronectin, laminin, type I collagen on migration of osteoblast. Migration distance and speed of MC3T3-E1 cell on extracellular matrix-coated glass were measured for 24 hours using 0.01% type I collagen, 0.01% fibronectin, 100 microliter/ml laminin. The migration distance and speed of MC3T3-E1 cell was compared using a video-microscopy system. To determine migration speed, cells were viewed with a 4 phase- contrast lens and video recorded. Images were captured using a color CCD camera and saved in 8-bit full-color mode. The migration distance on 0.01% type I collagen or 0.01% fibronectin was longer than that on $100{\mu}l/ml$ laminin-coated glass. The migration speed on fibronectin-coated glass was 68 micrometer/hour which was fastest. The migration speed on type I collagen-coated glass was similar with that on fibronectin-coated glass. The latter two migration speeds were faster than that on no-coated glass. On the other hand, the average migration speed on laminin-coated glass was 37micrometer/hour and not different from that of control group. In conclusion, the extracelluar matrix ligands such as type I collagen and fibronectin seem to play an important role in cell migration. The type I collagen or fibronectin coated scaffold is more effective for migration of osteoblast in tissue engineering process.

In Situ Monitoring of the MBE Growth of AlSb by Spectroscopic Ellipsometry

  • Kim, Jun-Yeong;Yun, Jae-Jin;Lee, Eun-Hye;Bae, Min-Hwan;Song, Jin-Dong;Kim, Yeong-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.342-343
    • /
    • 2013
  • AlSb is a promising material for optical devices, particularly for high-frequency and nonlinear-optical applications. And AlSb offers significant potential for devices such as quantum-well lasers, laser diodes, and heterojunction bipolar transistors. In this work we study molecular beam epitaxy (MBE) growth of an unstrained AISb film on a GaAs substrate and identify the real-time monitoring capabilities of in situ spectroscopic ellipsometry (SE). The samples were fabricated on semi-insulating (0 0 1) GaAs substrates using MBE system. A rotating sample stage ensured uniform film growth. The substrate was first heated to $620^{\circ}C$ under As2 to remove surface oxides. A GaAs buffer layer approximately 200 nm- thick was then grown at $580^{\circ}C$. During the temperature changing process from $580^{\circ}C$ to $530^{\circ}C$, As2 flux is maintained with the shutter for Ga being closed and the reflection high-energy electron diffraction (RHEED) pattern remaining at ($2{\times}4$). Upon reaching the preset temperature of $530^{\circ}C$, As shutter was promptly closed with Sb shutter open, resulting in the change of RHEED pattern from ($2{\times}4$) to ($1{\times}3$). This was followed by the growth of AlSb while using a rotating-compensator SE with a charge-coupled-device (CCD) detector to obtain real-time SE spectra from 0.74 to 6.48 eV. Fig. 1 shows the real time measured SE spectra of AlSb on GaAs in growth process. In the Fig. 1 (a), a change of ellipsometric parameter ${\Delta}$ is observed. The ${\Delta}$ is the parameter which contains thickness information of the sample, and it changes in a periodic from 0 to 180o with growth. The significant change of ${\Delta}$ at~0.4 min means that the growth of AlSb on GaAs has been started. Fig. 1b shows the changes of dielectric function with time over the range 0.74~6.48 eV. These changes mean phase transition from pseudodielectric function of GaAs to AlSb at~0.44 min. Fig. 2 shows the observed RHEED patterns in the growth process. The observed RHEED pattern of GaAs is ($2{\times}4$), and the pattern changes into ($1{\times}3$) with starting the growth of AlSb. This means that the RHEED pattern is in agreement with the result of SE measurements. These data show the importance and sensitivity of SE for real-time monitoring for materials growth by MBE. We performed the real-time monitoring of AlSb growth by using SE measurements, and it is good agreement with the results of RHEED pattern. This fact proves the importance and the sensitivity of SE technique for the real-time monitoring of film growth by using ellipsometry. We believe that these results will be useful in a number of contexts including more accurate optical properties for high speed device engineering.

  • PDF

Watching environment-independent color reproduction system development based on color adaption (색순응을 기반하여 관촬환경에 독립한 색재현 시스템 개발)

  • An, Seong-A;Kim, Jong-Pil;An, Seok-Chul
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.21 no.2
    • /
    • pp.43-53
    • /
    • 2003
  • As information-communication network has been developed rapidly, internet users' circumstances also have been changed for the better, in result, more information can be applied than before. At this moment, there are many differences between real color and reappeared color on the CRT. When we observe a material object, our eyes perceive the multiplied form of light sources and nature spectral reflection. However, when the photographed signal is reappeared, illumination at that time of photographing and spectral reflection of a material object are converted into signal, and this converted RGB signal is observed on the CRT under another illumination. At this time, RGB signal is the reflected result of illumination at that time of photographing Therefore, this signal is influenced by the illumination at present, so it can be perceived another color. To accord the colro reflections of another color source, the study has been reported by S.C.Ahn$^{[1]}$, which study is about the color reapperarance system using neuron network. Furthermore, color reappearing method become independent of its circumstances has been reported by Y.Miyake$^{[2]}$. This method can make the same illuminations even if the observe circumstances are changed. To assume the light sources of observe circumstances, the study about color reappearing system using CCD sensor also have been studied by S.C.Ahn$^{[3]}$. In these studies, a population is fixed, first, on ab coordinates of CIE L${\ast}$a${\ast}$b${\ast}$. Then, color reappearing can be possible using every population and existing digital camera. However, the color is changed curvedly, not straightly, according to value's changes on the ab coordinates of CIE L${\ast}$a${\ast}$b. To solve these problems in this study, first of all, Labeling techniques are introduced. Next, basis color-it is based on Munsell color system-is divided into 10 color fields. And then, 4 special color- skin color, grass color, sky color, and gray-are added to the basis color. Finally, 14 color fields are fixed. After analyzing of the principle elements of new-defined-color fields' population, utility value and propriety value are going to be examined in 3-Band system from now on.

  • PDF

DYNAMICAL SUBSTRUCTURES OF GALACTIC GLOBULAR CLUSTERS II. NGC 6934 (우리은하 구상성단들의 역학적 세부구조 II. NGC 6934)

  • Rhee, Jong-Whan;Sohn, Young-Jong;Shin, Min;Kang, Aram
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.249-262
    • /
    • 2004
  • The variations of the dynamical substructures of NGC 6934 have been investigated by means of performing point spread function stellar photometry and the surface photometry on BV CCD images of NGC 6934. Our results show that overall variations of ellipticity and position angle range in $0.02{\sim}0.08\;and\;-90^{\circ}{\sim}+90^{\circ}$, respectively out to three times the half light radius. The inner ($r_{eff}) substructures of NGC 6934 inferred from the variations of ellipticity and position angle are mainly affected by the bright red giant populations, while the effects of the other giant populations are weaker than those of the bright red giant populations. Horizontal branch populations and faint red giant star populations affect the dynamical substructures of NGC 6934 in the region of $r_h.