• Title/Summary/Keyword: CCA Test

Search Result 37, Processing Time 0.024 seconds

Strength Property of the Incised Larix (Larix kaempferi Carr.) Round Posts treated with CCA (인사이징 처리 낙엽송 CCA-방부원주목의 강도 성능 평가)

  • Park, Jun-Chul;Kim, Sang-Woo;Ryu, Jae-Yun;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.85-92
    • /
    • 2008
  • Strength of logs and round posts is compared and analyzed to estimate the strength of the incised Larix round posts treated with CCA in this paper. There is no significant difference in MOR of logs and round posts. However, in the incised Larix round posts treated with CCA MOE is decreased to about 9%, and there is 29% reduction in MOR as strength ratio is 0.71. When calculating the allowable bending stress of incised round type round posts, not in nominal 2-in timbers, an adjustment factor for MOE and bending strength is proposed as 0.91 and 0.71, respectively. Logs, round posts and the incised Larix round posts treated with CCA do not show significant difference in nail withdrawal load. There is almost no difference between incised Larix round posts treated with CCA and round posts in the shear strength of bolted joint. When calculating the allowable shear stress of bolted joint, it is conformed that considering the application of incising factor is not necessary.

Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers (골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.833-844
    • /
    • 2018
  • Dual energy X-ray absorptiometry is mainly used as an X-ray test method. For equipment manufactured GE and Hologic, cross-calibration analyses (CCA) of machines from the same manufacturer and between units from different manufacturers have been conducted, but the CCA of equipment manufactured in Korea are inadequate. Through CCA, we present a formula of the intersections between the Korean medical equipment company (KEC) with GE and Hologic manufactured DXA, and among the KEC DXA. The CCA was conducted for the European Spine Phantom on DXA from four KEC and three global medical equipment company (GEC) manufacturers. We compared bone mineral density (BMD) values and calculated the CCA equation by linear regression analysis. The standard-deviations (SD) of the BMD values were highest for the Dexxum T for the low, medium, and high spine, which were 0.030, 0.029, and 0.037, respectively. The smallest SD in the low and medium vertebrae were 0.005 and 0.004 for the Horizon Ci, respectively, and 0.005 for the Osteo Pro Max in the high vertebrae. Based on the intersection equations of the KEC DXA established in this study, CCA of various KEC DXA should be established for more accurate follow-up of BMD tests in clinical environments.

Stabilization of As in Soil Contaminated with Chromated Copper Arsenate (CCA) Using Calcinated Oyster Shells (목재방부제(CCA) 오염토양의 소성가공 굴껍질을 이용한 비소 안정화)

  • Moon, Deok-Hyun;Cheong, Kyung-Hoon;Kim, Tae-Sung;Khim, Jee-Hyeong;Choi, Su-Bin;Moon, Ok-Ran;Ok, Yong-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.4
    • /
    • pp.378-385
    • /
    • 2009
  • Arsenic (As) is known to be very toxic and carcinogenic to human beings. Arsenic contaminated soil was collected from a timber mill site at Busan Metropolitan City, Korea, where chromated copper arsenate (CCA) had been used to protect wood from rotting caused by insects and microbial agents. The soil was stabilized using both natural oyster shells (NOS) and calcinated oyster shells (POS). The calcination of natural oyster shells was accomplished at a high temperature in order to activate quicklime from calcite. Two different oyster shell particle sizes (-#10 mesh and -#20 mesh) and curing periods of up to 28 days were investigated. The stabilization effectiveness was evaluated based on the Korean Standard Test (KST) method (1N HCl extraction). The stabilization results showed that the POS treatment was more effective than the NOS treatment at immobilizing the As in the contaminated soils. A significant As reduction (96%) was attained upon a POS treatment at 20 wt% and passed the Korean warning standard of 20 mg/kg ('Na' area). However, an As reduction of only 47% (169 mg/kg) was achieved upon a NOS treatment at 20 wt%. The -#20 mesh oyster shells seem to perform better than the -#10 materials. The scanning electron microscopy (SEM)-energy dispersive X-ray spectroscopy (EDX) results showed that As immobilization was strongly associated with Ca and O in the presence of Al and Si.

Prevalence and Co-infection of Intestinal Parasites among Thai Rural Residents at High-risk of Developing Cholangiocarcinoma: A Cross-sectional Study in a Prospective Cohort Study

  • Songserm, Nopparat;Promthet, Supannee;Wiangnon, Surapon;Sithithaworn, Paiboon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6175-6179
    • /
    • 2012
  • Intestinal parasitic infections (IPIs) are still important to the health of Thai rural residents. IPIs are the cause of many chronic diseases with, for example, opisthorchiasis resulting in progression to cholangiocarcinoma (CCA). This cross-sectional study in a prospective cohort study aimed to examine the prevalence and co-infection of intestinal parasites among Northeastern Thai rural residents, recruited into the Khon Kaen Cohort Study (KKCS), and who were residing in areas of high-risk for developing CCA. On recruitment, subjects had completed questionnaires and provided fecal samples for IPI testing using the formalin ethyl acetate concentration technique. Data on selected general characteristics and the results of the fecal tests were analysed. IPI test results were available for 18,900 of cohort subjects, and 38.50% were found to be positive for one or more types of intestinal parasite. The prevalence of Opisthorchis viverrini (O. viverrini) infection was the highest (45.7%), followed by intestinal flukes (31.9%), intestinal nematodes (17.7%), intestinal protozoa (3.02%), and intestinal cestodes (1.69%). The pattern of different infections was similar in all age groups. According to a mapping analysis, a higher CCA burden was correlated with a higher prevalence of O. viverrini and intestinal flukes and a greater intensity of O. viverrini. Both prevention and control programs against liver fluke and other intestinal parasites are needed and should be delivered simultaneously. We can anticipate that the design of future control and prevention programmes will accommodate a more community-orientated and participatory approach.

Study on the Relationship between Carotid Intima-Media Thickness and Korean Standard of Pattern Identification in Ischemic Stroke Patients (뇌경색 환자의 경동맥 초음파 검사와 한방 중풍 변증과의 관련성 연구)

  • Kim, Kyoung Min
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • ■ Objectives The purpose of this study was to investigate the correlation of The Korean Standard Pattern Identification for Stroke and Intima-Media Thickness of common carotid artery(CCA-IMT). ■ Methods 100 subjects with acute ischemic stroke were recruited from the patients admitted to DongEui Medical Center from the June 2011 to January 2014. We assessed 100 patient's Common Carotid Intima Media Thickness data by B Mode ultrasonography. We investigated pattern identification of all subjects based on Korean Standard Pattern Identification for Stroke-III. then, We analyzed their characteristics, risk factor, blood test result, life style. ■ Results We analyzed indicators of Korean Standard Pattern Identification for Stroke-III by Common Carotid Intima Media Thickness difference. As a result, pale complexion, look powerless, drowsiness like to lie, heat vexation and aversion to heat were significantly higher in the CCAIMT ≧ 1.0mm group then in the CCA-IMT < 1.0mm group. ■ Conclusion According to the analysis, the Relationship between Carotid Intima-Media Thickness and The Korean Standard Pattern Identification for Stroke in Ischemic Stroke Patients were founded. To acquire more concrete conclusion on this theme, we need more research.

  • PDF

Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke (인체 요골동맥과 경동맥의 혈액에코박동지수: 나이 및 뇌졸중과의 관계)

  • Bok, Tae-Hoon;Kong, Qi;Nam, Kweon-Ho;Choi, Jay Chol;Paeng, Dong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.494-501
    • /
    • 2012
  • In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group ($0.13{\pm}0.11$ and $0.16{\pm}0.03$). PIBE of CCA for the young group, however, was larger than that for the old group ($0.70{\pm}0.21$ and $0.32{\pm}0.01$), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients ($336{\pm}61$ and $340{\pm}126mg/dl$) were more than that of the control group ($264{\pm}38$ and $257{\pm}43mg/dl$), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

Study on Relationship Between Intima Medial Thickness and the Plaque in Stroke Patients on Carotid Artery Sonography (뇌경색 환자에서 초음파로 측정한 경동맥 내막-중막두께와 죽상경화반의 관련성에 대한 연구)

  • Lee, Mi-Hwa;Kwon, Duk-Mun;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • The carotid intima-media thickness (IMT) is an early structural marker of the atherosclerotic process and is the only non-invasive test that is currently recommended by the American Heart Association for evaluation of the risk. However, use of this parameter has a limitation because it assumes uniform thickness throughout the blood vessel, whereas atherosclerosis is a focal phenomenon that is confined to intima. In fact, plaque can be found along the atherosclerotic blood vessels even though its value is unknown. The aim of this study is to analyze the carotid plaque and IMT in the stroke patients. We investigated the patients with ischemic stroke, who were admitted to the department of neurology at the Stroke Special Hospital from January to March 2008. After the carotid IMT and plaque were assessed by B-mode ultrasonography, IMT and carotid plaque to risk variables (age, sex) were analyzed. The distribution of CCA IMT was significantly different in terms of age (p = 0.004). Likewise, the distribution of carotid plaque was also significantly different in terms of age (p = 0.006). Carotid plaque was 69 and 92% in normal and abnormal CCA IMTs respectively. The results showed that the CCA IMT was closely associated with carotid plaque.

  • PDF

Exploring Reliability of Wood-Plastic Composites: Stiffness and Flexural Strengths

  • Perhac, Diane G.;Young, Timothy M.;Guess, Frank M.;Leon, Ramon V.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.2
    • /
    • pp.153-173
    • /
    • 2007
  • Wood-plastic composites (WPC) are gaining market share in the building industry because of durability/maintenance advantages of WPC over traditional wood products and because of the removal of chromated copper arsenate (CCA) pressure-treated wood from the market. In order to ensure continued market share growth, WPC manufacturers need greater focus on reliability, quality, and cost. The reliability methods outlined in this paper can be used to improve the quality of WPC and lower manufacturing costs by reducing raw material inputs and minimizing WPC waste. Statistical methods are described for analyzing stiffness (tangent modulus of elasticity: MOE) and flexural strength (modulus of rupture: MOR) test results on sampled WPC panels. Descriptive statistics, graphs, and reliability plots from these test data are presented and interpreted. Sources of variability in the MOE and MOR of WPC are suggested. The methods outlined may directly benefit WPC manufacturers through a better understanding of strength and stiffness measures, which can lead to process improvements and, ultimately, a superior WPC product with improved reliability, thereby creating greater customer satisfaction.

  • PDF

Local Similarity based Document Layout Analysis using Improved ARLSA

  • Kim, Gwangbok;Kim, SooHyung;Na, InSeop
    • International Journal of Contents
    • /
    • v.11 no.2
    • /
    • pp.15-19
    • /
    • 2015
  • In this paper, we propose an efficient document layout analysis algorithm that includes table detection. Typical methods of document layout analysis use the height and gap between words or columns. To correspond to the various styles and sizes of documents, we propose an algorithm that uses the mean value of the distance transform representing thickness and compare with components in the local area. With this algorithm, we combine a table detection algorithm using the same feature as that of the text classifier. Table candidates, separators, and big components are isolated from the image using Connected Component Analysis (CCA) and distance transform. The key idea of text classification is that the characteristics of the text parallel components that have a similar thickness and height. In order to estimate local similarity, we detect a text region using an adaptive searching window size. An improved adaptive run-length smoothing algorithm (ARLSA) was proposed to create the proper boundary of a text zone and non-text zone. Results from experiments on the ICDAR2009 page segmentation competition test set and our dataset demonstrate the superiority of our dataset through f-measure comparison with other algorithms.

Charging-Discharging Behavior and Performance of AGM Lead Acid Battery/EDLC Module for x-HEV (x-HEV용 AGM 연축전지/EDLC 통합모듈의 성능 및 충방전 거동)

  • Kim, Sung Joon;Seo, Sung Won;An, Sin Young;Kim, Bong-Gu;Son, Jeong Hun;Jung, Yeon Gil
    • Korean Journal of Materials Research
    • /
    • v.31 no.2
    • /
    • pp.84-91
    • /
    • 2021
  • To cope with automobile exhaust gas regulations, ISG and charging control systems are applied to HEV vehicles for the purpose of improving fuel economy. These systems require quick charge-discharge performance of high current. Therefore, a Module of the AGM battery with high energy density and EDLC(Electric Double Layer Capacitor) with high power density are constructed to study the charging and discharging behavior. In CCA, which evaluates the starting performance at -18 ℃ & 30 ℃ with high current, EDLC contributed for about 8 sec at the beginning. At 0 ℃ CA (Charge Acceptance), the initial Charging current of the AGM/EDLC Module, is twice that of the AGM lead acid battery. To play the role of EDLC during high-current rapid charging and discharging, the condition of the AGM lead-acid battery is optimally maintained. As a result of a Standard of Battery Association of Japan (SBA) S0101 test, the service life of the Module of the AGM Lead Acid Battery/EDLC is found to improve by 2 times compared to that of the AGM Lead Acid Battery.