• Title/Summary/Keyword: CC1₄

Search Result 2,049, Processing Time 0.033 seconds

Enhancement of delamination strength in Cu-stabilized coated conductor tapes through additional treatments under transverse tension at room temperature

  • Shin, Hyung-Seop;Bautista, Zhierwinjay;Moon, Seung-Hyun;Lee, Jae-Hun;Mean, Byoung-Jean
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.25-28
    • /
    • 2017
  • In superconducting coil applications particularly in wet wound coils, coated conductor (CC) tapes are subjected to different type of stresses that could affect its electromechanical transport property. These include hoop stress acting along the length of the CC tape and the Lorentz force acting perpendicular to the CC tape's surface. Since the latter is commonly associated with the delamination problem of multi-layered REBCO CC tapes, more understanding and attention on the delamination phenomena induced in the case of coil applications are needed. Difference on the coefficient of thermal expansion (CTE) of each constituent layer of the CC tape, the bobbin, and the impregnating materials is the main causes of delamination in CC tapes when subjected to thermal and mechanical cycling. In the design of degradation-free superconducting coils, therefore, characterization of the delamination behaviors including mechanism and strength in the multi-layered REBCO CC tapes becomes a critical issue. Various trials to increase the delamination strength by improving interface characteristics at interlayers have been performed. In this study, in order to investigate the influences of laser cleaning and Ag annealing treated at the substrate side surface, transverse tensile tests were conducted under different sample configurations using $4.5mm{\times}8mm$ upper anvil. The mechanical delamination strength of differently processed CC samples was examined at room temperature (RT). As a result, the Sample 1 with the additional laser cleaning and Ag annealing processes and the Sample 2 with additional Ag annealing process only showed higher mechanical delamination strength as compared to the Sample 3 without such additional treatments. Sample 3 showed quite different behavior when the loading direction is to the substrate side where the delamination strength much lower as compared to other cases.

Correlation of the Consolidation Characteristics of Inland and Harbour District Soil (육상 및 항만지역상의 압밀특성치의 상관성)

  • 도덕현;이성태;강우묵
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.25 no.4
    • /
    • pp.50-60
    • /
    • 1983
  • 305 samples of alluvial deposit in inland and harbour districts were selected and consolidation charateristics of the alluvium were put in order statiscally. The correlations between them were as follows. 1. The relationships between LL(liguid limit) and Cc (compression index) were explained as Cc=0. 03(LL-21. 7) in case of inland district soil and as Cc=0. 019(LL-19) in case of harbour district soil. As compared with formular proposed by Skernpton, the gradient of this linear line was slight steep. 2. The relationships between PI(plastic index) and Cc were explained as Cc=0. 063 PI-0. 52 in case of inland district soil and Cc=0. 043 PI-0. 31 in case of harbour district soil. 3. As void ratio and natural moisture content were increased, Cc was increased, and as wet density was increased, Cc was decreased with a gentle curve. 4. As LL and P1 increased, mv(coefficient of volume compressibility) was increased but if LL and P1 was increased beyond a certain extend, mv has a tendency of constant value, that is, mv show a tendency to take constant value in the very soft clay. and mv in P=2. 5kg/cm$^2$ was about l${\times}$ l0-$^1$cm$^2$/kg in case of land district soil and 6x 10-$^1$crn$^2$/kg in case of harbour district soil lower than that in P=0. 25kg/crn2. 5. Cv(coefficient of consolidation) was a tendency to decrease with a gentle curve as LL was increased, and Cv in P=0. 25kg/crn2 was about 3x l0-$^1$crn$^2$/min larger than that in P=2. 5kg/crn$^2$. 6. Relationships between Py(pre-consolidation pressure) which is included over consolidation soil and ∑r1h(effective over-burden pressure) were explained as Py=l. 12 ∑r'h in case of land district soil and as Py=l. l5∑r'h in case of harbour district soil. 7. Some of the properties show good correlations between them, practical and effective applications of these correlations are expected in the planning and excution of soil investigation and also in the evaluation of the results.

  • PDF

Quality Characteristics and Variation of Wheat Breeding Lines (소맥육성계통의 품질특성과 변이에 관하여)

  • Chang, H.G.;Ryu, I.S.;Cho, C.H.;Bae, S.H.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.24 no.1
    • /
    • pp.37-45
    • /
    • 1979
  • Experiments were conducted to determine the physicochemical properties for 1.382 tested wheat harvested in 1977. All the tested wheats had a milling yield rate of 49 to 71.5 percent. The cross combination involving S.son, Caprock and CI 12703 was generally the higher in flour yield-Flour protein content ranged from about 7 percent up to about 17 percent and sedimentation values ranged from below 20 cc to 70 cc. The cross combinations involving Bb #1 gave higher protein content and higher sedimentation values than the other combinations. The distribution of the Pelshenke value was from less 20 min. to more than 180 min. Specific sedimentation values of the 329 tested wheats showed 8.1 percent to be hard quality, while 54.4 percent were of soft quality. Intermediate wheats accounted for 37.5 percent. The lines having high milling yield rate, protein content and sedimentation value from the 329 tested wheats were Strampelli \times 69D-3607/Jogwang. S.son \times Caprock. Suweon #185 \times Toropi and Suweon #185 \times Ciano. The varieties or lines including Pribog, CI 14496 and Sturdy \times Scout/ Strampelli \times Bb-Cno showed high milling yield but low protein content and low sedimentation values. being under 9 percent and 30 cc respectively.

  • PDF

Feasibility of a Linear Diode Array Detector for Commissioning of a Radiotherapy Planning System

  • Seung Mo Hong;Uiseob Lee;Sung-woo Kim;Youngmoon Goh;Min-Jae Park;Chiyoung Jeong;Jungwon Kwak;Byungchul Cho
    • Progress in Medical Physics
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: Although ionization chambers are widely used to measure beam commissioning data, point-by-point measurements of all the profiles with various field size and depths are time-consuming tasks. As an alternative, we investigated the feasibility of a linear diode array for commissioning a treatment planning system. Methods: The beam data of a Varian TrueBeam® radiotherapy system at 6 and 10 MV with/without a flattening filter were measured for commissioning of an Eclipse Analytical Anisotropic Algorithm (AAA) ver.15.6. All of the necessary beam data were measured using an IBA CC13 ionization chamber and validated against Varian "Golden Beam" data. After validation, the measured CC13 profiles were used for commissioning the Eclipse AAA (AAACC13). In addition, an IBA LDA-99SC linear diode array detector was used to measure all of the beam profiles and for commissioning a separate model (AAALDA99). Finally, the AAACC13 and AAALDA99 dose calculations for each of the 10 clinical plans were compared. Results: The agreement of the CC13 profiles with the Varian Golden Beam data was confirmed within 1% except in the penumbral region, where ≤2% of a discrepancy related to machine-specific jaw calibration was observed. Since the volume was larger for the CC13 chamber than for the LDA-99SC chamber, the penumbra widths were larger in the CC13 profiles, resulting in ≤5% differences. However, after beam modeling, the penumbral widths agreed within 0.1 mm. Finally the AAALDA99 and AAACC13 dose distributions agreed within 1% for all voxels inside the body for the 10 clinical plans. Conclusions: In conclusion, the LDA-99SC diode array detector was found to be accurate and efficient for measuring photon beam profiles to commission treatment planning systems.

Constituents of the Essential Oil of the Cinnamomum cassia Stem Bark and the Biological Properties

  • Choi, Jong-won;Lee, Kyung-Tae;Ka, Hyeon;Jung, Won-Tae;Jung, Hyun-Ju;Park, Hee-Juhn
    • Archives of Pharmacal Research
    • /
    • v.24 no.5
    • /
    • pp.418-423
    • /
    • 2001
  • CC-MS analysis on the essential oil (CC-oil) of Cinnamomum cassia stem bark led to the identification of cinnamaldehyde (CNA, 1), 2-hydroxycinnamaldehyde (2-CNA), coumarin (2), and cinnamyl acetate. The major volatile flavor in CC-oil was found to be 2-CNA. Coumarin was first isolated from this plant by photochemical isolation and spectroscopic analysis. CNA and CC-oil showed potent cytotoxicity, which was effectively prevented by N-acetyl-L-cysteine (NAC) treatment. Intraperitoneal administration with CNA considerably decreased malondialdehyde (MDA) formation and glutathione S-transferase activity in rats. These results suggest that CC-oil and CNA can regulate the triggering of hepatic drugmetabolizing enzymes by the formation of a glutathione-conjugate.

  • PDF

CC를 적용한 시스템 보안평가 동향

  • 이경구;손경호
    • Review of KIISC
    • /
    • v.13 no.4
    • /
    • pp.25-36
    • /
    • 2003
  • 현재 미국을 비롯한 선진 국가에서는 ISO 국제 표준인 국제 공통 평가 기준 ISO/IEC 15408(CC v2.1, Common Criteria for Information Technology Security Evaluation))과 공통평가방법론(CEM, Common Methodology for Information Technology Security Evaluation)에 근거하여 IT 제품 및 시스템에 대한 보안성 평가를 하고 있다. 그러나, 현재 CC 및 CEM은 주로 IT 제품의 보안성 평가를 위한 것이며, 실제 IT 환경에서 운용되는 시스템에서 이를 적용해 평가하는데는 많은 어려움이 있다. ISO를 중심으로 각 국에서도 이와 관련해 시스템 평가에 CC를 적용하기 위한 방법론이 검토 중에 있다. 그리고 현재 개발 진행중이거나 시장에 출시된 많은 제품이 여러 단일 제품이 합성된 통합제품 형태로 구성되고 있는 추세이며, 이는 시스템 평가 문제와 더불어 향후 CC 기반의 평가를 활성화시키기 위해 풀어야 할 문제로 제기되고 있다. 본고에서는 각 국에서 추진 중인 시스템 평가 동향을 살펴보고, 현재 ISO/IEC SC27/WG3에 표준화로 제안된 "Security Assessment of Operational System"에 대해 살펴보고자 한다.자 한다.

Common Criteria Evaluations: What a Developer Should Know (국제공동평가기준의 평가를 받기 위한 개발자 고려사항 분석)

  • Kim, K.S.;Nam, T.Y.;Sohn, S.W.;Park, C.H.
    • Electronics and Telecommunications Trends
    • /
    • v.18 no.1 s.79
    • /
    • pp.17-24
    • /
    • 2003
  • 본 고에서는 정보보호제품에 대한 국제공통평가기준인 CC(Common Criteria)의 적용방안에 대해 분석하였다. CC에서는 왜 보증등급에 대해 다루는지에 대한 물음에 대답하고, CC에 대해 개발자들이 알아야할 것은 무엇인지, 그리고 기존 평가기준과의 차이점은 무엇인지에 대해 살펴보았다. CC 평가를 염두에두고 정보보호시스템 개발을 할 경우 고려해야 할 개발자 입장에서의 이슈들에 대해 정리하고 처리방안에 대해 제시하였다. 마지막으로 제품 평가를 위한 평가과정, 평가를 위해 개발자가 준비해야 하는 개발증거물들을 제시하고, CC에 따른 제품 평가의 효과에 대해 살펴보았다.

Analysis on reduction characteristics of magnetization loss in YBCO CC by slit numbers (YBCO CC의 slit 개수에 따른 자화손실 저감 특성 해석)

  • Lee, Kwang-Youn;Park, Myung-Jin;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1249-1251
    • /
    • 2005
  • YBCO CC의 초전도 전력기기 응용에 대한 자화손실 저감을 위한 연구가 진행중이다. 본 논문에서는 임계상태 모델에 기초한 수치해석을 이용하여 슬릿개수의 변화에 따른 YBCO CC의 자화손실 저감 특성을 해석하였다. 수치해석을 위한 YBCO CC의 규격은 두께와 폭이 각각 $2{\mu}m$, 4mm이며 슬릿에 의한 선재분한인 필라멘트는 각각 2,4,8개이다. 또한, 수치해석의 결과는 strip모델의 자화손실식과 비교하였다. 해석 결과, 자기적으로 결합되지 않은 strip모델 해석값과 수치해석값은 차이를 보였으며 필라멘트 개수의 변화에 따라 약 1/n 수준으로 자화손실이 저감됨을 확인하였다.

  • PDF

CC-GiST: Cache Conscious-Generalized Search Trees (CC-GiST:캐쉬 인식하는 일반화된 검색 트리)

  • 김원식;이동민;김재화;한욱신
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04b
    • /
    • pp.88-90
    • /
    • 2004
  • 주기억 징치 DBMS성능에 캐쉬 미스가 중요한 요소이다. 그래서 캐쉬 미스를 줄여주는 캐쉬 인식 트리(chash consclous trees)들이 개발되어 왔다. 캐쉬 인식 트리에서 사용한 기법들은 포인터 압축, 키 압축 개념으로 일반화 할 수 있다. 포인터 압축은 CS$B^{+}$-트리처럼 노드에 각 자식 노드를 가리키는 포인터를 제거하고 대신 세그먼트에 저장된 자식 노드들 중 첫 번째 자식 노드를 가리키는 포인터를 저장하는 개념이다. 키 압축은 pkB-트리, R-트리처럼 키 길이를 출이는 개념이다. 본 논문에서는 키 압축 개념과 포인터 압축 개념을 동싱에 지원하고, 디스크 기반의 GiST를 캐쉬 인식하도록 확장한 CC-GiST를 제안한다. 본 논문의 공헌은 다음과 같이 요약된다. 1)기존의 캐쉬 인식 트리들의 기법을 분류하고 분석함으로써, 캐쉬 인식 트리에 적용할 수 있는 일반적인 방법을 도출하였다. 2)포인터 압축을 위해 세그먼트의 개념을 키 압축을 위하여 베이스 키의 개념을 CC-GiST에 도입하였다. 3)디스크 기반의 GiST를 위해 기정의된 메소드들을 캐쉬 인식하도록 완전하게 수정하였다. 4) 제안한 CC-GiST를 이용하여 기존의 대표적인 캐쉬 인식 트리인 CSB+-트리와 CR-트리를 구현하는 방법을 기술하였다.

  • PDF

A Study on the Factors Affecting Asbestos Exposure Level from Asbestos Abatement in Building Demolition Sites (석면 해체·제거시 공기 중 노출수준과 영향요인)

  • Kim, Ji-Yeong;Lee, Song-Kwon;Lee, Jeong Hee;Lim, Mu Heok;Kang, Sungwook;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was examined to find out asbestos exposure level the factors which affected the level at asbestos abatement sites. We visited a total of thirteen building demolition sites(3 apartments, 3 schools, 4 stores, and 3 houses) were visited to collect samples and related data from August to November, 2006. The results of this study were as follows 1. The results of an analysis of bulk samples to identify types of asbestos at the asbestos abatement sites showed that the kinds of the asbestos detected were chrysotile by 50.0%, were tremolite by 2.6%, and were the contents of chrysotile by 3 to 20%. 2. The geometric mean concentration of asbestos was 0.007 f/cc(range 0.001-0.34 f/cc) and its geometric standard deviation was 5.83. Of the samples, however, 12 exceeded the Korean Occupational Exposure Limit(0.1f/cc). 3. Of the materials, textile material had the highest concentration with geometric mean of 0.016 f/cc. When asbestos-containing materials were removed using T type tools, the geometric mean concentration of asbestos was 0.061 f/cc. The level by this method was much higher than by other removal methods. In analysis by the type of building, the geometric mean concentration of asbestos in stores was 0.042 f/cc and was higher than in other buildings. 4. The Poisson regression analysis was applied to find out the factors that affect the airborne asbestos concentration. As a result of the analysis, removal using a T type tool was the most important factor affecting the asbestos concentration(p<0.01). In conclusion, the airborne asbestos concentration(geometric mean) in asbestos abatement sites was 0.007 f/cc(0.001~0.34 f/cc), and 12(14.6%) of all samples were over the 0.1 f/cc. These results showed that asbestos abatement workers have been exposed to the high level of airborne asbestos because they have not been keeping asbestos removal rule. In accordance with increases of the number of building demolition sites, the better government regulation on asbestos abatement methods should be made and be performed well at building demolition sites.