• Title/Summary/Keyword: CC response

Search Result 132, Processing Time 0.026 seconds

SANET-CC : Zone IP Allocation Protocol for Offshore Networks (SANET-CC : 해상 네트워크를 위한 구역 IP 할당 프로토콜)

  • Bae, Kyoung Yul;Cho, Moon Ki
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.4
    • /
    • pp.87-109
    • /
    • 2020
  • Currently, thanks to the major stride made in developing wired and wireless communication technology, a variety of IT services are available on land. This trend is leading to an increasing demand for IT services to vessels on the water as well. And it is expected that the request for various IT services such as two-way digital data transmission, Web, APP, etc. is on the rise to the extent that they are available on land. However, while a high-speed information communication network is easily accessible on land because it is based upon a fixed infrastructure like an AP and a base station, it is not the case on the water. As a result, a radio communication network-based voice communication service is usually used at sea. To solve this problem, an additional frequency for digital data exchange was allocated, and a ship ad-hoc network (SANET) was proposed that can be utilized by using this frequency. Instead of satellite communication that costs a lot in installation and usage, SANET was developed to provide various IT services to ships based on IP in the sea. Connectivity between land base stations and ships is important in the SANET. To have this connection, a ship must be a member of the network with its IP address assigned. This paper proposes a SANET-CC protocol that allows ships to be assigned their own IP address. SANET-CC propagates several non-overlapping IP addresses through the entire network from land base stations to ships in the form of the tree. Ships allocate their own IP addresses through the exchange of simple requests and response messages with land base stations or M-ships that can allocate IP addresses. Therefore, SANET-CC can eliminate the IP collision prevention (Duplicate Address Detection) process and the process of network separation or integration caused by the movement of the ship. Various simulations were performed to verify the applicability of this protocol to SANET. The outcome of such simulations shows us the following. First, using SANET-CC, about 91% of the ships in the network were able to receive IP addresses under any circumstances. It is 6% higher than the existing studies. And it suggests that if variables are adjusted to each port's environment, it may show further improved results. Second, this work shows us that it takes all vessels an average of 10 seconds to receive IP addresses regardless of conditions. It represents a 50% decrease in time compared to the average of 20 seconds in the previous study. Also Besides, taking it into account that when existing studies were on 50 to 200 vessels, this study on 100 to 400 vessels, the efficiency can be much higher. Third, existing studies have not been able to derive optimal values according to variables. This is because it does not have a consistent pattern depending on the variable. This means that optimal variables values cannot be set for each port under diverse environments. This paper, however, shows us that the result values from the variables exhibit a consistent pattern. This is significant in that it can be applied to each port by adjusting the variable values. It was also confirmed that regardless of the number of ships, the IP allocation ratio was the most efficient at about 96 percent if the waiting time after the IP request was 75ms, and that the tree structure could maintain a stable network configuration when the number of IPs was over 30000. Fourth, this study can be used to design a network for supporting intelligent maritime control systems and services offshore, instead of satellite communication. And if LTE-M is set up, it is possible to use it for various intelligent services.

ABCB1 Polymorphisms and Imatinib Response in Chronic Myeloid Leukemia Patients: A Systematic Review and Meta-analysis (ABCB1 유전적 다형성이 만성 골수성 백혈병 환자의 Imatinib 치료 반응에 미치는 영향: 체계적 문헌고찰 및 메타분석)

  • Ha, Hye Min;Chun, Pusoon
    • YAKHAK HOEJI
    • /
    • v.60 no.3
    • /
    • pp.118-127
    • /
    • 2016
  • A growing number of studies have demonstrated that ABCB1 gene polymorphisms are associated with the variability of responses to imatinib. However, the effects of ABCB1 polymorphisms on imatinib response in chronic myeloid leukemia (CML) are inconsistent. The aim of the present study was to clarify the associations between ABCB1 polymorphisms and imatinib response in CML. A systematic literature review was performed. The databases of PubMed, Embase, and Cochrane Library were searched for all published studies from inception to December 2015. The following terms were used with functions of 'AND' and 'OR': 'chronic myeloid leukemia', 'CML', 'ABCB1', 'MDR1', 'polymorphism', 'SNP', and 'imatinib'. Using the Review Manager 5, odds ratios (ORs) were pooled to estimate the effect of ABCB1 polymorphisms on imatinib response in CML. The pooled analysis showed that ABCB1 2677 G allele was significantly associated with poor response to imatinib in African and Asian patients (GG vs TT, OR: 0.32, p<0.0001; GG+GT vs TT, OR: 0.44, p=0.0005). In subgroup analyses, African patients carrying ABCB1 1236 C allele exhibited higher risk for worse response, whereas Asian patients with 1236 C allele showed better response (CC+CT vs TT, OR: 0.41, p=0.008 for African; OR: 1.65, p=0.03 for Asian). There was no association between C3435T polymorphisms and imatinib response in African, Asian, and Caucasian CML patients.

Systemic Immediate Hypersensitive Reactions after Treatment with Sweet Bee Venom: A Case Report

  • Jo, NaYoung;Roh, JeongDu
    • Journal of Pharmacopuncture
    • /
    • v.18 no.4
    • /
    • pp.59-62
    • /
    • 2015
  • Objectives: A previous study showed that bee venom (BV) could cause anaphylaxis or other hypersensitivity reactions. Although hypersensitivity reactions due to sweet bee venom (SBV) have been reported, SBV has been reported to be associated with significantly reduced sensitization compared to BV. Although no systemic immediate hypersensitive response accompanied by abnormal vital signs has been reported with respect to SBV, we report a systemic immediate hypersensitive response that we experienced while trying to use SBV clinically. Methods: The patient had undergone BV treatment several times at other Oriental medicine clinics and had experienced no adverse reactions. She came to acupuncture & moxibustion department at Semyung university hospital of Oriental medicine (Je-cheon, Korea) complaining of facial hypoesthesia and was treated using SBV injections, her first SBV treatment. SBV, 0.05 cc, was injected at each of 8 acupoints, for a total of 0.40 cc: Jichang (ST4), Daeyeong (ST5), Hyeopgeo (ST6), Hagwan (ST7), Yepung (TE17), Imun (TE21), Cheonghoe (GB2), and Gwallyeo (SI18). Results: The patient showed systemic immediate hypersensitive reactions. The main symptoms were abdominal pain, nausea and perspiration, but common symptoms associated with hypersensitivity, such as edema, were mild. Abdominal pain was the most long-lasting symptom and was accompanied by nausea. Her body temperature decreased due to sweating. Her diastolic blood pressure could not be measured on three occasions. She remained alert, though the symptoms persisted. The following treatments were conducted in sequence; intramuscular epinephrine, 1 mg/mL, injection, intramuscular dexamethasone, 5 mg/mL, injection, intramuscular buscopan, 20 mg/mL, injection, oxygen ($O_2$) inhalation therapy, 1 L/minutes, via a nasal prong, and intravascular injection of normal saline, 1 L. After 12 hours of treatment, the symptoms had completely disappeared. Conclusion: This case shows that the use of SBV does not completely eliminate the possibility of hypersensitivity and that patients who received BV treatment before may also be sensitized to SBV. Thus, a skin test should be given prior to using SBV.

(Task Creation and Allocation for Static Load Balancing in Parallel Spatial Join (병렬 공간 조인 시 정적 부하 균등화를 위한 작업 생성 및 할당 방법)

  • Park, Yun-Phil;Yeom, Keun-Hyuk
    • Journal of KIISE:Databases
    • /
    • v.28 no.3
    • /
    • pp.418-429
    • /
    • 2001
  • Recently, a GIS has been applicable to the most important computer applications such as urban information systems and transportation information systems. These applications require spatial operations for an efficient management of a large volume of data. In particular, a spatial join among basic operations has the property that its response time is increased exponentially according to the number of spatial objects included in the operation. Therefore, it is not proper to the systems demanding the fast response time. To satisfy these requirements, the efficient parallel processing of spatial joins has been required. In this paper, the efficient method for creating and allocating tasks to balance statically the load of each processor in a parallel spatial join is presented. A task graph is developed in which a vertex weight is calculated by the cost model I have proposed. Then, it is partitioned through a graph partitioning algorithm. According to the experiments in CC16 parallel machine, our method made an improvement in the static load balance by decreasing the variance of a task execution time on each processor.

  • PDF

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Development of Wound Rotor Synchronous Motor for Belt-Driven e-Assist System

  • Lee, Geun-Ho;Lee, Heon-Hyeong;Wang, Qi
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.487-493
    • /
    • 2013
  • The automotive industry is showing widespread interest in belt-driven electric motor-assisted (e-Assist) systems. A belt-driven assist system (BAS) starts and assists the combustion engine in place of the conventional generator. In this study, a water-cooled wound rotor synchronous motor (WRSM) for the e-Assist system was designed and analyzed. The performance of the WRSM was compared with that of an interior permanent magnet synchronous motor (IPMSM). The WRSM efficiency can be improved for the BAS by adjusting the field flux at high speeds. The field current map to obtain the maximum efficiency based on the speed and torque was developed. To control the field flux via field current control in the WRSM, a general H-bridge circuit was added to the WRSM inverter to get the rapid current response in the high-speed region; the characteristics were compared with the chopper circuit. A WRSM developed for the belt-driven e-Assist system and a prototype 115 V power electronic converter to drive the WRSM were tested with a 900 cc combustion engine. The test results showed that the WRSM-type e-Assist system had good characteristics and could successfully start and assist the 900 cc combustion engine.

Design of Compact Common Mode Noise Absorption Filter (공통 모드 노이즈를 흡수하는 소형 공통 모드 필터 설계)

  • Jung, Hyeonjong;Jung, Jinwoo;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.963-968
    • /
    • 2018
  • In this paper, a compact common mode filter using passive elements is designed and fabricated. To design a common mode filter with required frequency response, the equivalent circuits of the common mode filter in differential mode and common mode were analyzed. Compared with the former filter using a ${\lambda}/4$ resonator, the size of the proposed structure was reduced by 60 %. The fabricated common mode filter has a maximum differential mode insertion loss of 1.2 dB and a minimum common mode absorption efficiency of 78.2% in the CMA - bandwidth of 27.5 %.

Impact of ABCB1 C3435T Polymorphism on Treatment Response of Vitamin K Antagonists: A Systematic Review and Meta-analysis

  • Lee, So Yeon;An, Sook Hee
    • Korean Journal of Clinical Pharmacy
    • /
    • v.32 no.3
    • /
    • pp.238-250
    • /
    • 2022
  • Objective: The aim of this study was to examine the impact of ATP-binding cassette subfamily B member 1 (ABCB1) C3435T polymorphism on the treatment response of patients to vitamin K antagonists (VKAs). Methods: In this systematic review and meta-analysis, the PubMed/Medline, Embase, and Cochrane Library databases were searched for eligible articles for the period up to November 2020. Articles that reported treatment response to VKAs according to the ABCB1 C3435T polymorphism were included in this study. Results: A total of 13 and 9 articles were included in the systematic review and meta-analysis, respectively. The weekly maintenance dose of warfarin was significantly lower in patients with the ABCB1 3435CT or TT polymorphism type than in those with the ABCB1 3435CC type (weighted mean difference [WMD], -2.53 mg/week; 95% confidence interval [CI], -3.64 to -1.43, p<0.001). However, the weekly maintenance dose of acenocoumarol was not significantly associated with the ABCB1 C3435T polymorphism (WMD, 1.02; 95% CI, -0.61 to 2.65, p=0.22). Conclusion: The ABCB1 C3435T polymorphism was significantly associated with the weekly maintenance dose of warfarin. Further research is needed to confirm the association between the ABCB1 C3435T polymorphism and the incidence rate of bleeding events.

A Study and Design on security ticket based CERT system for quantified incident management (정량적 침해사고 관리를 위한 Security Ticket 기반의 침해사고 관리시스템(CERT) 설계 및 관리방안 연구)

  • Kim, Sun-Tae;Jun, Moon-Seog;Park, Dea-Woo
    • KSCI Review
    • /
    • v.15 no.1
    • /
    • pp.141-150
    • /
    • 2007
  • There's been a difficulty for general corporate to adopt recent incident response study because those studies focus on nation wide CERT Coordination Center or large organization aspect. This study is focus on study and design on security ticket based CERT system through analysis Security management's threat element, attack element. response element and it also help general corporate establish incident response process that is adjusted on IT operation. Confirmed CERT model's effectiveness and effect of quantitative Security incident management wav that propose executing Security incident response experiment on the basis of this way. This study which Provides general corporate oriented CERT model can be used to improve corporate's capability of responding incident by quantified management technique and select incident response SLA indicator. Already, formation which operate CERT can heighten corporation's information protection level by measure Security incident response result as metrical and analyze and improve problem continuously.

  • PDF

Effect of Sipjundaebotang on the immune response of CD4+ and CD8+ T cell in rats (십전대보탕(十全大補湯)이 CD4+ 및 CD8+ T세포수(細胞數)에 미치는 영향(影響))

  • Ko, Young-Kwon;Ryu, Bong-Ha;Park, Dong-Won;Ryu, Ki-Won
    • THE JOURNAL OF KOREAN ORIENTAL ONCOLOGY
    • /
    • v.4 no.1
    • /
    • pp.111-129
    • /
    • 1998
  • In order to research the effect of Sipjundaebotang on the immune respons of CD4+ T cell and CD8+ T cell in rats, author have performed this experimental study. Experimental groups are divided into 5 groups(intact, control, sample I, sample II, sample III). Normal group was intact, control group was administrated normal saline 2cc for 5 days, sample I was administrated low concentration of Sipjundaebotang(100/3100pack/ml) 2cc for 5 days, sample II was administrated middle concentration of Sipjundaebotang(500/3100pack/ml) 2cc for 5 days, sample III was administrated high concentration of Sipjundaebotang(2500/3100pack/ml) 2cc for 5 days. WBC, Lymphocyte, CD4+ T cell in the blood, spleen, axillary node and CD8+ T cell in the blood, spleen and axillary node were determined. The results was as follows: 1. WBC count in blood was significantly decrcased in the control, sample I, II, III groups as compared with the normal group. 2. Lymhocyte count in the blood was significantly decreased in the control, sample I, II groups as compared with the normal group. 3. CD4+ T cell count in the blood was significantly increased dose-dependently in the sample I, II, III groups as compared with the normal group. 4. CD4+ T cell count in the spleen was significantly increased in the sample I, II, III groups as compared with the normal group. 5. CD4+ T cell count in the axillary node was significantly increased in the sample III group as compared with the normal group, however significantly decreased in the sample I, II groups as compared with the normal group. 6. CD8+ T cell count in the blood was significantly increased in the sample III groups as compared with the normal group. 7. CD8+ T cell count in the spleen was significantly increased in the sample I, II, III groups as compared with the normal group. but there was no differences in the sample groups. 8. CD8+ T cell count in the axillary node was decreased in the sample I, II groups as compared with the normal group.

  • PDF