• Title/Summary/Keyword: CBCT 유도수술

Search Result 3, Processing Time 0.017 seconds

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.

Evaluation of the usefulness of IGRT(Image Guided Radiation Therapy) for markerless patients using SGPS(Surface-Guided Patient Setup) (표면유도환자셋업(Surface-Guided Patient Setup, SGPS)을 활용한 Markerless환자의 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)시 유용성 평가)

  • Lee, Kyeong-jae;Lee, Eung-man;Lee, Jeong-su;Kim, Da-yeon;Ko, Hyeon-jun;Choi, Shin-cheol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.109-116
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the usefulness of Surface-Guided Patient Setup by comparing the patient positioning accuracy when image-guided radiation therapy was used for Markerless patients(unmarked on the skin) using Surface-Guided Patient Setup and Marker patients(marked on the skin) using Laser-Based Patient Setup. Materials And Methods: The position error during IGRT was compared between a Markerless patient initially set up with SGPS using an optical surface scanning system using three cameras and a Marker patient initially set up with LBPS that aligns the laser with the marker drawn on the patient's skin. Both SGPS and LBPS were performed on 20 prostate cancer patients and 10 Stereotactic Radiation Surgery patients, respectively, and SGPS was performed on an additional 60 breast cancer patients. All were performed IGRT using CBCT or OBI. Position error of 6 degrees of freedom was obtained using Auto-Matching System, and comparison and analysis were performed using Offline-Review in the treatment planning system. Result: The difference between the root mean square (RMS) of SGPS and LBPS in prostate cancer patients was Vrt -0.02cm, Log -0.02cm, Lat 0.01cm, Pit -0.01°, Rol -0.01°, Rtn -0.01°, SRS patients was Vrt 0.02cm, Log -0.05cm, Lat 0.00cm, Pit -0.30°, Rol -0.15°, Rtn -0.33°. there was no significant difference between the two regions. According to the IGRT standard of breast cancer patients, RMS was Vrt 0.26, Log 0.21, Lat 0.15, Pit 0.81, Rol 0.49, Rtn 0.59. Conclusion:. As a result of this study, the position error value of SGPS compared to LBPS did not show a significant difference between prostate cancer patients and SRS patients. In the case of additionally performed SGPS breast cancer patients, the position error value was not large based on IGRT. Therefore, it is considered that it will be useful to replace LBPS with SGPS, which has the great advantage of not requiring patient skin marking..

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.