• Title/Summary/Keyword: CAF

Search Result 109, Processing Time 0.028 seconds

Concentrations of Airborne Fungi and Environmental Factors in the Subway Stations in Seoul, Korea (서울지하철 일부 역사 내 부유 곰팡이 농도 및 환경요인)

  • Hwang, Sung Ho;Ahn, Jae Kyoung;Park, Jae Bum
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.2
    • /
    • pp.81-87
    • /
    • 2014
  • Objectives: We measured the concentrations of culturable airborne fungi (CAF) in enclosed environments at 16 underground subway stations of the Seoul Metro in 2013, and investigated the effect of environmental factors, including temperature, relative humidity, the number of passengers, and distance from the platform. Methods: The cultured fungi were identified by the lactophenol cotton blue (LPCB) staining method and were classified by observing the form, shape, and color of colony. A nonparametric analysis was used to determine if the differences in the concentrations of CAF were statistically significant. Results: The concentrations of CAF at the stations were the highest in station p ($367CFU/m^3$) with arange between 3 and $437CFU/m^3$. There was a significant correlation between CAF concentration and the distance from platform (r = 0.544, p < 0.01). Geotrichum spp. and Penicillium spp. were the predominant species. Conclusion: It is recommended that special attention be given during rush hour, which is in the morning (08:00-10:00) and in the early evening (18:00-19:00) to improve the indoor air quality of the subway stations.

Farmers Preference and Perception towards Cropland Agroforestry in Bangladesh

  • Chakraborty, M.;Haider, M.Z.;Rahaman, M.M.
    • Journal of Forest and Environmental Science
    • /
    • v.31 no.4
    • /
    • pp.241-254
    • /
    • 2015
  • This study attempts to examine farmers' preference and perception towards cropland agroforestry (CAF) and its economic benefits in Bangladesh. It surveys 84 farmers of two sub-districts named Manirampur and Bagherpara under Jessore district of Bangladesh to address the study objectives with the help of a questionnaire during the period of June to July 2013. We follow a multistage random sampling procedure for selecting respondents of the survey. A total of 27 plant species under 19 families are identified in the surveyed crop fields, among which 11 are tree species and 1 is shrub from 8 families and 15 species are agricultural crops from 11 families. According to the survey findings, most of the farmers prefer multipurpose tree species like Swietenia macrophylla (67 percent), Phoenix sylvestris (48 percent), Mangifera indica (48 percent) and Cocos nucifera (43 percent). We also find that Curcuma longa (92 percent), Oryza spp. (56 percent), Solanum melongena (43 percent) and Amorphophallus campanulatus (33 percent) are the available agriculture crops which are grown in association with trees in the study area. The surveyed farmers report that they practice CAF to get fuel wood, fodder, juice, fruit and food for family consumption and revenue earnings. About 76 percent of the surveyed farmers endorse the existence of a positive interaction between trees and agriculture crops, while the rest 24 percent endorse the existence of a negative interaction between trees and agriculture crops. This study finds that CAF farmers on an average earn US$ 1,410 per farm per year and the yearly average revenue difference between CAF and non-cropland agroforestry (NCAF) farmers is US$ 214. Overall, CAF needs to develop through scientific intervention in the study area to conserve the biodiversity and to enhance farmers' sustainable livelihood.

Determination of Ascorbic Acid, Acetaminophen, and Caffeine in Urine, Blood Serum by Electrochemical Sensor Based on ZnO-Zn2SnO4-SnO2 Nanocomposite and Graphene

  • Nikpanje, Elham;Bahmaei, Manochehr;Sharif, Amirabdolah Mehrdad
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.173-187
    • /
    • 2021
  • In the present research, a simple electrochemical sensor based on a carbon paste electrode (CPE) modified with ZnO-Zn2SnO4-SnO2 and graphene (ZnO-Zn2SnO4-SnO2/Gr/CPE) was developed for the direct, simultaneous and individual electrochemical measurement of Acetaminophen (AC), Caffeine (Caf) and Ascorbic acid (AA). The synthesized nano-materials were investigated using scanning electron microscopy, X-ray Diffraction, Fourier-transform infrared spectroscopy, and electrochemical impedance spectroscopy techniques. Cyclic voltammetry and differential pulse voltammetry were applied for electrochemical investigation ZnO-Zn2SnO4-SnO2/Gr/CPE, and the impact of scan rate and the concentration of H+ on the electrode's responses were investigated. The voltammograms showed a linear relationship between the response of the electrode for individual oxidation of AA, AC and, Caf in the range of 0.021-120, 0.018-85.3, and 0.02-97.51 μM with the detection limit of 8.94, 6.66 and 7.09 nM (S/N = 3), respectively. Also, the amperometric technique was applied for the measuring of the target molecules in the range of 0.013-16, 0.008-12 and, 0.01-14 μM for AA, AC and, Caf with the detection limit of 6.28, 3.64 and 3.85 nM, respectively. Besides, the ZnO-Zn2SnO4-SnO2/Gr/CPE shows an excellent selectivity, stability, repeatability, and reproducibility for the determination of AA, AC and, Caf. Finally, the proposed sensor was successfully used to show the amount of AA, AC and, Caf in urine, blood serum samples with recoveries ranging between 95.8% and 104.06%.

A Test-bed for DCAF (DeCentralized Analysis Farm) (탈중심분산팜(DeCentralized Analysis Farm)의 테스트베드 구축)

  • 조기현;오영도;권기환;한대희;손동철;김복주;이상산
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04a
    • /
    • pp.46-48
    • /
    • 2003
  • 미국 페르미연구소에서 현재 수행되고 있는 고에너지물리 실험의 하나인 CDF 실험에서는 현재 303대의 Dual CUP 클러스터를 이용한 중심분석용팜(CAF, Central Analysis Farm)을 페르미 연구소 내에 구성하여 실제 데이터 처리 및 모의 시늉 데이터를 생산하는데 사용하고 있다. 그러나 페르미 연구소에서의 중심분석용팜(CAF)은 향후 그 자원이 충분치가 못하므로, 이에 참여하고 있는 여러 나라의 컴퓨팅 자원들을 공유할 수 있어야 한다. 따라서, 한국그룹은 경북대학교 고에너지물리연구소에 있는 PC 클러스터를 활용하여 탈중심분산팜 (DCAF, DeCenteralized Analysis Farm)을 국제공동연구로 설계하여 테스트베드를 구축하였다. 이 구성에는 CAF의 기술뿐만 아니라 페르미 연구소라는 원격에 있는 실험 데이터를 이용하여 job을 수행하므로 데이터 전송 기술인 SAM(Sequential data Access via Meta-data) 및 Kerberos의 보안 시스템, 그리드(Grid)를 포함하는 모든 IT 기술의 종합으로 이루어져있다.

  • PDF

Root coverage using a coronally advanced flap with or without acellular dermal matrix: a meta-analysis

  • Guan, Wei;Liao, Haiqing;Guo, Li;Wang, Changning;Cao, Zhengguo
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.1
    • /
    • pp.22-34
    • /
    • 2016
  • Purpose: Gingival recession is a major esthetic concern and may lead to root sensitivity during periodontal treatment. Coronally advanced flaps (CAFs) with and without acellular dermal matrix (ADM) are widely used in root coverage procedures. The aim of this study was to analyze the efficacy of CAF in combination with ADM in the treatment of gingival recession. Methods: PubMed, The Cochrane Library, and Embase were used to identify relevant articles. The articles were screened, data were extracted, and the quality of the studies was assessed by three reviewers with expertise in clinical practice, trials, statistics, and biomedical editing. The clinical endpoints of interest included changes in recession, probing depth (PD), clinical attachment level (CAL), and keratinized tissue (KT). Results: Ten randomized controlled trials were identified, including six studies that compared CAFs with ADM and CAFs using connective tissue grafting (CTG) and four studies that compared CAFs with or without ADM. No statistically significant differences were found between the use of ADM and CTG, whereas statistically significant differences were found between groups in which ADM and CAF were combined and groups that underwent CAF alone with regard to recession coverage, CAL, and KT. The combination of CAF with an ADM allograft achieved more favorable recession coverage and recovery of CAL and KT than CAF alone. Conclusions: The results from the ADM and CTG groups suggest that both procedures may be equally effective in clinical practice. Given the limitations of this study, further investigation is needed to clarify the effectiveness of ADM and CAF in clinical practice.

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

Coronary artery fistula associated with single coronary artery (단일관상동맥 동정맥루 1례)

  • Kim, Seong Man;Song, Min Seob;Cho, Kwang Hyun;Kim, Chul Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.10
    • /
    • pp.1118-1122
    • /
    • 2008
  • A case of a single coronary artery complicated with a coronary artery fistula (CAF) to the right ventricle is extremely rare, and its management strategy and prognosis are not clear. A 5-year-old boy was hospitalized for evaluation of a continuous heart murmur. Transthoracic echocardiography suggested a CAF to the right ventricle, with an enlarged left coronary artery. Cardiac catheterization confirmed the CAF terminating at the right ventricle and the absence of a right coronary artery. The fistula was ligated at the right ventricular side under cardiopulmonary bypass. At follow-up 18 months later, the child was clinically asymptomatic, and coronary angiogram showed no recurrence of the fistula.

Evaluation test of applicability of Compressed Air Foam fire extinguishing system for train fire at rescue station in Subsea tunnel (해저터널 구난역 열차화재시 압축공기포(Compressed Air Foam) 소화설비의 적용성 평가 실험)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.413-418
    • /
    • 2016
  • Recently, a mega project such as Korea-China or Korea-Japan undersea tunnel project has been emerged for detail discussion and the interest in undersea tunnel is on the rise. More severe damage by train fire is expected in undersea tunnel comparing to ground tunnel and thus the study on more efficient fire extinguishing system, besides existing disaster prevention design is underway. To that end, a full-scale fire tests using CAF fire extinguishing system which has been developed by modifying traditional foam fire extinguishing system for fire suppression at rescue station in timely manner were conducted over 7 times. The test was conducted after setting the rescue station in virtual tunnel with a car of KTX. As a result of using compressed air foam directly to the fire source, 30 liter of Heptane combustibles was extinguished within 1 minutes. Applicability of compressed air foam to train fire at rescue station in undersea tunnel was has been proven and further study is considered required while changing the nozzle angle and location so as to achieve quick and easy extinguishing goal, making use of the advantage of CAF, as well as to reduce the fire water and chemicals required.

Development of Search and Rescue System with Dynamic Model by RF Signal Based LTE (탐색구조 시스템에서의 RF 신호 기반 동역학 모델 적용 및 개발)

  • Jeong, I.C.;Kim, D.W.;Ahn, W.G.;Lee, S.
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.120-124
    • /
    • 2017
  • This paper describes the product of search and rescue system with dynamic model. This spread spectrum system based new standard of COSPAS-SARSAT is results of RF signal generation and transmission. we will test performance evaluation which implement signal process adapting Dynamic model and we will adapt the CAF model using TDOA and FDOA relationship.

Repair and Retrofit System of Concrete Structures using Fiber Glass and Epoxy Composite Sheets, Improved Through Utilization of Silica fume and Mechanical Saturator (실리카흄과 현장기계함침을 이용한 유리섬유 복합재(CAF)의 콘크리트 구조물 보수보강공법)

  • 유용하;권성준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.785-792
    • /
    • 2000
  • Repair and retrofit system of concrete structures has been developed from conventional reinforced concrete overlaying, steel plate bonding and recently to fiber composite systems. Research and study on carbon, aramid, and glass fiber composite system has been actively carried out from all over the world Glass fiber composite is proved to be competitive technically and enconomically, among fiber composite system. CAF system is a system developed locally using all domestic materal, glass fabric and epoxy, and improved in shear bonding property by utilizing silica fume mixed with epoxy. All the tests on material properties, structural behavior, constructiveness at site and quality control procedure proved to be most appropriate system so far developed. Futher research work is and will be under progress for utilization of this system which will be applied to more adverse situation.

  • PDF