• 제목/요약/키워드: CAD-CAM denture

검색결과 86건 처리시간 0.019초

Cellular responses to 3D printed dental resins produced using a manufacturer recommended printer versus a third party printer

  • Beatriz Sona Cardoso;Mariana Brito da Cruz;Joana Faria Marques;Joao Carlos Roque;Joao Paulo Martins;Rodrigo Cordeiro Malheiro;Antonio Duarte da Mata
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권2호
    • /
    • pp.126-138
    • /
    • 2024
  • PURPOSE. The aim of this study was to evaluate the influence of different 3D dental resins, using a manufacturer recommended printer and a third-party printer, on cellular responses of human gingival cells. MATERIALS AND METHODS. Three NextDent resins (Denture 3D+, C&B MFH and Crowntec) were used to produce specimens on printers NextDent 5100 (groups ND, NC and NT, respectively) and Phrozen Sonic Mini 4K (groups PD, PC and PT, respectively). Human gingival fibroblasts were cultured and biocompatibility was evaluated on days 1, 3 and 7. IL-6 and IL-8 concentrations were evaluated at 3 days using ELISA. Surface roughness was evaluated by a contact profilometer. SEM and fluorescence micrographs were analyzed at days 1 and 7. Statistical analyses were performed using SPSS and mean differences were tested using ANOVA and post-hoc Tukey tests (P < .05). RESULTS. There was an increase in cellular viability after 7 days in groups PC and PT, when compared to group PD. ND group resulted in higher concentration of IL-6 when compared to PT group. SEM and fluorescence micrographs showed less adhesion and thinner morphology of fibroblasts from group PD. No significant differences were found regarding surface roughness. CONCLUSION. The use of different printers or resins did not seem to influence surface roughness. NextDent 5100 and Phrozen Sonic Mini 4K produced resins with similar cellular responses in human gingival fibroblasts. However, Denture 3D+ resin resulted in significantly lower biocompatibility, when compared to C&B MFH and Crowntec resins. Further testing is required to support its long-term use, required for complete dentures.

A STUDY ON THE MARGINAL FIT OF COLLARLESS METAL CERAMIC FIXED PARTIAL DENTURES

  • Yoon Jong-Wook;Yang Jae-Ho;Han Jung-Seok;Lee Jae-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제43권6호
    • /
    • pp.707-716
    • /
    • 2005
  • Statement of problem. Collarless metal ceramic fixed partial dentures(FPDs) had an esthetic problem such as opaque reflection in cervical region. To overcome this, modified coping which removed its facial cervical metal could be used. The marginal quality could be worsen according to the amount of its facial metal reduction. Purpose. The purpose of this study was to evaluate marginal fits of collarless metal ceramic FPDs with retainers of modified copings. Material and method. Dentoform maxillary left central incisor and right lateral incisor were prepared for 3-unit collarless metal ceramic FPD and fixed in yellow stone. This model was duplicated to PBT resin dies via CAD/CAM and injection molding. Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Seven collarless metal ceramic FPDs per group were fabricated. They were cemented to PBT resin dies with resin cement. After removal of pontics, each retainers were separated and observed under Accura 2000 optical microscope. Then, retainers were embeded in orthodontic resin and cross sectioned faciopalatally. Internal marginal fits of midfacial porcelain margins were observed under FE-SEM. Result and conclusion. Within the limitations of this in vitro study. The following conclusions were drawn. 1. Mean marginal gaps of collarless FPDs were in the $50-60{\mu}m$ range. 2. In midfacial margin, marginal discrepancies were greater in group A than in the experimental groups(p<0.05). 3. In midpalatal margin, marginal gaps were greater in group C and D than in group A and B(p<0.05). 4. Marginal fits of porcelain margins were better than those of metal margins in collarless metal ceramic FPDs. 5. In both teeth, internal marginal gaps of group C and D were greater than those of group A and B(p<0.05).

Full mouth rehabilitation of the patient with crossed occlusion using implant fixed prosthesis: A case report (엇갈린 교합 환자에서 임플란트 고정성 보철물을 이용한 수복증례)

  • Jung, Byung-Suk;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제56권4호
    • /
    • pp.338-346
    • /
    • 2018
  • Crossed occlusion can be treated either by overdenture and telescopic denture or by placing an implant at the edentulous area to reestablish the support on the occlusion. If alveolar bony support is sufficient and an the environment where an implant is inserted is favorable to restoring the masticatory and aesthetic function of a patient, the implant-supported fixed prosthesis can provide more definitive occlusal support and more aid for other oral functions. In this case report, a patient with a severe residual alveolar bone resorption following the extraction of teeth and who had a crossed occlusion was treated with sinus bone graft and alveolar bone augmentation in order to place the implants at prosthetically position. The definitive restoration was made to reflect the patient's occlusal and aesthetic function using the CAD/CAM double scanning method. Finally, the treatment had the masticatory and aesthetic function adequately restored, which is reported here.

The job analysis of dental technicians in Busan, Gyeongnam (부산, 경남지역 치과기공사의 직무분석)

  • Nah, Jung-Sook
    • Journal of Technologic Dentistry
    • /
    • 제36권4호
    • /
    • pp.277-296
    • /
    • 2014
  • Purpose: This study intends to set standard for organizing the curriculum of short-term dental technicians and the change of job environment, as well as the knowledge & training, by identifying the importance and actual job performance of dental technicians following job analysis in the university education of Dept. of Dental Laboratory Technology, and furthermore to foster junior executives to cope with modernization and globalization. Methods: The tools used in this study are based on the job analysis of research report suggested by National Health Personnel Licensing Examination Board(Lee Gyu-seon, 2011), and it consists of general characteristic 7 items. Every competence duty was measured through Likert 5 point gauging, and internal consistency through Cronbach's Alpha. The competence importance of entire questionnaire was .984 and its performance was .874, reflecting considerably high level, and in terms of each competence duty, high credibility was proved and high internal consistency was verified with competence importance ranging from the minimum .655 to the maximum .966 and its performance ranging from the minimum .677 to the maximum .993. Results: Competence importance and its performance in each duty on the job analysis of dental technicians were measured. In competence importance in each duty, the highest was "checking design order form"(average, 4.52), followed by "selling dental prosthesis"(average 4.49), "making removable orthodontic appliance"(average, 4.48), "open managing dental laboratory"(average, 4.46) in order. However, "making complete denture" was found the lowest(average, 4.23), with importance of all competence dutys was considerably high level. In the performance of its competence duty, "checking design order form"(average, 4.04) was found to be the most importance competence, followed by "making conservative restoration"(average, 4.00), "making porcelain"(average 3.98), "checking working cast"(average, 3.90) in order. However it was found out that "making fixed orthodontic appliance"(average, 3.12) was the lowest, and the importance of all competence dutys was quite high level. Conclusion: The duties of dental technicians consist of 13 kinds, in total, and it was found out that "checking design order form"(average, 4.52) was the most important in the competence importance and job performance. In particular, it was revealed that there was a great difference between the competence importance and its performance in the order of "selling dental prosthesis", "open managing dental laboratory", "making removable orthodontic appliance", "making CAD/CAM prosthesis", and then "making fixed orthodontic appliance".

Comparison of Flexural Strength of Three-Dimensional Printed Three-Unit Provisional Fixed Dental Prostheses according to Build Directions

  • Park, Sang-Mo;Park, Ji-Man;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young
    • Journal of Korean Dental Science
    • /
    • 제12권1호
    • /
    • pp.13-19
    • /
    • 2019
  • Purpose: The aim of this study was to compare the flexural strength of provisional fixed dental prostheses which was three-dimensional (3D) printed by several build directions. Materials and Methods: A metal jig with two abutment teeth and pontic space in the middle was fabricated. This jig was scanned with a desktop scanner and provisional restoration was designed on dental computer-aided design program. On the preprocessing software, the build angles of the restorations were arranged at $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ and support was added and resultant structure was sliced to a thickness of $100{\mu}m$. Processed restorations were printed with digital light processing type 3D printer using poly methyl meta acrylate-based resin. After washing and post-curing, compressive loading was applied at a speed of 1 mm/min on a metal jig fixed to a universal testing machine. The maximum pressure at which fracture occurred was measured. For the statistical analysis, build direction was set as the independent variable and fracture strength as the dependent variable. One-way analysis of variance and Tukey's post hoc analysis was conducted to compare fracture strength among groups (${\alpha}=0.05$). Result: The mean flexural strength of provisional restoration 3D printed with the build direction of $0^{\circ}$ was $1,053{\pm}168N$; it was $1,183{\pm}188N$ at $30^{\circ}$, $1,178{\pm}81N$ at $45^{\circ}$, $1,166{\pm}133N$ at $60^{\circ}$, and $949{\pm}170N$ at $90^{\circ}$. The group with a build direction of $90^{\circ}$ showed significantly lower flexural strength than other groups (P<0.05). The flexural strength was significantly higher when the build direction was $30^{\circ}$ than when it was $90^{\circ}$ (P<0.01). Conclusion: Among the build directions $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ set for 3D printing of fixed dental prosthesis, an orientation of $30^{\circ}$ is recommended as an effective build direction for 3D printing.

Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach (디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례)

  • Jeong, Areum;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제60권3호
    • /
    • pp.283-292
    • /
    • 2022
  • For fixed prosthetic treatment using implants, implants must be placed in a suitable location for prosthetic treatment. During surgery, minimally invasive prosthetic restoration is possible using a flapless method using a surgical guide. The patient in this case was an 86-year-old male patient who wanted treatment due to discomfort when using conventional dentures. Due to systemic disease, the patient had difficulty using removable local dentures, so full dentures for the maxilla and fixed implants for the mandible were restored. Because there is a high risk of bleeding due to systemic disease, the implant was placed in a flapless method using a surgical guide. Finally, prostheses were fabricated with maxillary full denture and mandibular screw-retained zirconia, and this report shows satisfactory esthetic and functional recovery.