• 제목/요약/키워드: CAD-CAM (computer-aided design and computer-aided manufacturing)

검색결과 213건 처리시간 0.024초

New CAD Datarization Technique of Shoe Lasts for Automation of the Adaptive Lasting Machine (적응형 라스팅기의 자동화를 위한 제화용 라스트의 새로운 CAD Data화 기법)

  • Kim, S.H.;Jang, K.K.;Kim, K.P.;Huh, H.;Kwon, D.S.
    • Korean Journal of Computational Design and Engineering
    • /
    • 제6권1호
    • /
    • pp.17-23
    • /
    • 2001
  • Lasting machines for shoe manufacturing are continuously developed with the aid of automation and CAM(Computer Aided Manufacturing). Although automation and CAM techniques have tremendously reduced the labor in shoe manufacturing, there still remain some parts manufactured by experts. In order to enhance the capability and efficiency of machines for labor-free shoe manufacturing, CAD data of a shoe last is essential. While CAD datarization takes the fundamental role in the shoe design and manufacturing, there has been little research for the CAD datarization of a shoe last. In this paper, a new procedure for CAD datarization of a shoe last using finite element patches and a tension sl)line method is proposed for application to shoe manufacturing machines. The outer line of a shoe-last sole is interpolated by a tension spline method and bonding lines are extracted from the shoe CAD data. Data set for a control algorithm of the tasting machine can be produced from the CAD data.

  • PDF

Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation

  • Myagmar, Gerelmaa;Lee, Jae-Hyun;Ahn, Jin-Soo;Yeo, In-Sung Luke;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.144-151
    • /
    • 2021
  • PURPOSE. The purpose of this in vitro study was to investigate the wear resistance and surface roughness of three interim resin materials, which were subjected to chewing simulation. MATERIALS AND METHODS. Three interim resin materials were evaluated: (1) three-dimensional (3D) printed (digital light processing type), (2) computer-aided design and computer-aided manufacturing (CAD/CAM) milled, and (3) conventional polymethyl methacrylate interim resin materials. A total of 48 substrate specimens were prepared. The specimens were divided into two subgroups and subjected to 30,000 or 60,000 cycles of chewing simulation (n = 8). The wear volume loss and surface roughness of the materials were compared. Statistical analysis was performed using one-way analysis of variance and Tukey's post-hoc test (α=.05). RESULTS. The mean ± standard deviation values of wear volume loss (in mm3) against the metal abrader after 60,000 cycles were 0.10 ± 0.01 for the 3D printed resin, 0.21 ± 0.02 for the milled resin, and 0.44 ± 0.01 for the conventional resin. Statistically significant differences among volume losses were found in the order of 3D printed, milled, and conventional interim materials (P<.001). After 60,000 cycles of simulated chewing, the mean surface roughness (Ra; ㎛) values for 3D printed, milled, and conventional materials were 0.59 ± 0.06, 1.27 ± 0.49, and 1.64 ± 0.44, respectively. A significant difference was found in the Ra value between 3D printed and conventional materials (P=.01). CONCLUSION. The interim restorative materials for additive and subtractive manufacturing digital technologies exhibited less wear volume loss than the conventional interim resin. The 3D printed interim restorative material showed a smoother surface than the conventional interim material after simulated chewing.

Shear bond strength of dental CAD-CAM hybrid restorative materials repaired with composite resin (치과용 복합레진으로 수리된 CAD-CAM hybrid 수복물의 전단결합강도)

  • Moon, Yun-Hee;Lee, Jonghyuk;Lee, Myung-Gu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제54권3호
    • /
    • pp.193-202
    • /
    • 2016
  • Purpose: This study was performed in order to assess the effect of the surface treatment methods and the use of bonding agent on the shear bond strength (SBS) between the aged CAD-CAM (computer aided design-computer aided manufacturing) hybrid materials and added composite resin. Materials and methods: LAVA Ultimate (LU) and VITA ENAMIC (VE) specimens were age treated by submerging in a $37^{\circ}C$ water bath filled with artificial saliva (Xerova solution) for 30 days. The surface was ground with #220 SiC paper then the specimens were divided into 9 groups according to the combination of the surface treatment (no treatment, grinding, air abrasion with aluminum oxide, HF acid) and bonding agents (no bonding, Adper Single Bond 2, Single Bond Universal). Each group had 10 specimens. Specimens were repaired (added) using composite resin (Filtek Z250), then all the specimens were stored for 7 days in room temperature distilled water. SBS was measured and the fractured surfaces were observed with a scanning electron microscope (SEM). One-way ANOVA and Scheffe test were used for statistical analysis (${\alpha}=.05$). Results: Mostly groups with bonding agent treatment showed higher SBS than groups without bonding agent. Among the groups without bonding agent the groups with aluminum oxide treatment showed higher SBS. However there was no significant difference between groups except two subgroups within LU group, which revealed a significant increase of SBS when Single Bond Universal was used on the ground LU specimen. Conclusion: The use of bonding agent when repairing an aged LAVA Ultimate restoration is recommended.

Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report (완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례)

  • Gang Soo Park;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제62권2호
    • /
    • pp.157-164
    • /
    • 2024
  • A variety of digital technologies are being used throughout the entire implant treatment process of diagnosis, surgery, impression, design, and fabrication of prostheses. In this case, using a digital surgical guide, sinus floor elevation was performed without complications, and the implants were placed in the planned position. After the healing period for osseointegration, CAD-CAM (Computer-aided design-Computer-aided manufacturing) customized abutments and provisional prostheses were delivered. While using the provisional prosthesis, occlusal change was observed. To transfer the intermaxillary relationship and abutment position that reflect occlusal change and axial displacement, double scanning and abutment-level digital impressions were taken. Abutment superimposition was used to capture the subgingival margin without gingival retraction. Then, the definitive prosthesis was designed and fabricated with digital system. We report a case applying digital system, to achieve the predictable result as well as the efficient treatment process from implant surgery to fabricating prosthesis in the posterior area.

Product Model for the Integration of Design and Manufacturing Information in Shipbuilding (선박의 설계 및 생산 정보의 통합을 위한 Product Model 의 구축)

  • S.B. Yoo;J.W. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • 제30권2호
    • /
    • pp.1-12
    • /
    • 1993
  • The role of product model in CIM environemt(where such heterogenous application programs as CAD, CAE, CAM, Database, and Expert Systems are included) is system integration. Product model manages all the information related to manufacuring activities. This information includes shapes, operation, process, scheduling, quality, and mangement. Product model architecture includes product model kernel, object schema, model manipulation language, and user interface. Objects to be shared are defined using the model manipulation luage and the defintions are saved in the object schema. In this paper, we present the design and implementation of a prototype. In this prototype, application programs for CAPP(Computer Aided Process Planning) are used.

  • PDF

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제61권4호
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

APPLICATION OF CAD/CAM FOR ORAL REHABILITATION IN A PATIENT WITH DOWN SYNDROME (CAD/CAM을 이용한 다운 증후군 환자의 구강 재건)

  • Chung, Hyunjin;Shim, Joon-Sung;Choi, Byung-Jai;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • 제13권2호
    • /
    • pp.95-98
    • /
    • 2017
  • Due to hypodontia, poor oral hygiene, and significantly more prevalent periodontal disease, patients with Down syndrome show higher incidence of edentulism. Oral rehabilitation of such patients is imperative but challenging as high rates of prosthesis failure are reported due to malocclusion, high masticatory force, and parafunctional habits. As CAD/CAM(Computer-Aided Design and Computer Aided Manufacturing) is the recent trend in prosthodontics, this report discusses the application of CAD/CAM in a Down syndrome patient. A 25-year-old patient with Down syndrome was presented to the Department of Pediatric Dentistry, Yonsei University Dental Hospital for oral examination. 5 maxillary teeth were missing, 3 were fully impacted, and 4 had grade III mobility. The patient underwent general anesthesia for extraction of impacted and mobile teeth, implant surgery, and final impression for prosthesis. Afterwards, CAD/CAM was used to design and manufacture a 10-unit zirconia bridge. However the bridge was fractured after 18 months due to the patient's bruxism and high masticatory force. Final impression taking, bite registration, cast fabrication, cast scanning, and prosthesis designing were not needed as CAD/CAM data remained. Previous CAD/CAM design was used to remanufacture the zirconia bridge. Down syndrome patients have malocclusion, high masticatory force, and parafunctional habits which increase the possibility of prosthesis fracture. CAD/CAM is beneficial for Down syndrome patients as previous digital records can be utilized for prosthesis repair or remake. In detail, application of CAD/CAM in remanufacturing decreases patient's discomfort of impression taking, shortens and simplifies dental laboratory procedures, and reduces clinician's effort of taking detailed final impressions or accurate bite registration. In conclusion, oral rehabilitation using CAD/CAM provides not only satisfactory levels of comfort, stability, and esthetics, but also easier repair or remake compared to conventional prostheses.

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

  • Song, Tae-Jin;Kwon, Taek-Ka;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.219-225
    • /
    • 2013
  • PURPOSE. Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS. Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS. Mean marginal gaps of 3-unit FPDs were $60.46{\mu}m$ for the Everest group, $78.71{\mu}m$ for the Lava group, and $81.32{\mu}m$ for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION. The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial

  • Gelin, Emilie;Seidel, Laurence;Bruwier, Annick;Albert, Adelin;Charavet, Carole
    • The korean journal of orthodontics
    • /
    • 제50권6호
    • /
    • pp.373-382
    • /
    • 2020
  • Objective: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainless-steel fixed retainers over a 12-month study period. Methods: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. Results: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. Conclusions: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainless-steel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.

Comparison of fracture strength after thermomechanical aging between provisional crowns made with CAD/CAM and conventional method

  • Reeponmaha, Tanapon;Angwaravong, Onauma;Angwarawong, Thidarat
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.218-224
    • /
    • 2020
  • PURPOSE. The objectives of this study were to evaluate the fracture strength and fracture patterns of provisional crowns fabricated from different materials and techniques after receiving stress from a simulated oral condition. MATERIALS AND METHODS. A monomethacrylate-based resin (Unifast Trad) and a bis-acryl-based (Protemp 4) resin were used to fabricate provisional crowns using conventional direct technique. A milled monomethacrylate resin (Brylic Solid) and a 3D-printed bis-acrylate resin (Freeprint Temp) were chosen to fabricate provisional crowns using the CAD/CAM process. All cemented provisional crowns (n=10/group) were subjected to thermal cycling (5,000 cycles at 5°-55℃) and cyclic occlusal load (100 N at 4 Hz for 100,000 cycles). Maximum force at fracture was tested using a universal testing machine. RESULTS. Maximum force at fracture (mean ± SD, N) of each group was 657.87 ± 82.84 for Unifast Trad, 1125.94 ± 168.07 for Protemp4, 953.60 ± 58.88 for Brylic Solid, and 1004.19 ± 122.18 for Freeprint Temp. One-way ANOVA with Tamhane post hoc test showed that the fracture strength of Unifast Trad was statistically significantly lower than others (P<.01). No statistically significant difference was noted among other groups. For failure pattern analysis, Unifast Trad and Brylic Solid showed less damage than Protemp 4 and Freeprint Temp groups. CONCLUSION. Provisional crowns fabricated using the CAD/CAM process and the conventionally fabricated bis-acryl resins exhibited significant higher fracture strength compared to conventionally fabricated monomethacrylate resins after the aging regimen. Therefore, CAD/CAM milling and 3D printing of provisional restorations may be good alternatives for long term provisionalization.