• 제목/요약/키워드: CAD/CAM materials

검색결과 293건 처리시간 0.029초

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

Six-year clinical performance of lithium disilicate glass-ceramic CAD-CAM versus metal-ceramic crowns

  • Ahmed Aziz;Omar El-Mowafy
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권1호
    • /
    • pp.44-54
    • /
    • 2023
  • PURPOSE. To assess the clinical performance of monolithic CAD-CAM lithium disilicate glass-ceramic (LDGC) crowns and metal-ceramic (MC) crowns provided by predoctoral students. This study also assessed the effects of patient and provider-related factors on their clinical performance as well as patient preference for these types of crowns. MATERIALS AND METHODS. Twenty-five patients who received 50 crowns (25 LDGC CAD-CAM and 25 MC) provided by predoctoral students were retrospectively examined. LDGC CAD-CAM crowns were milled in-house using the CEREC Bluecam system and cemented with either RelyX Unicem or Calibra Esthetic resin cements. MC crowns were cemented with RelyX Unicem cement. Clinical assessment of the crowns and the supporting periodontal structures were performed following the modified California Dental Association (CDA) criteria. Patients' preference was recorded using a visual analog scale (VAS). The results were statistically analyzed using log-rank test, Pearson Chi-squared test and Kaplan-Meier survival analysis. RESULTS. Twelve complications were observed in the MC crown group (9-esthetic, 2-technical and 1-biological). In comparison, 2 complications in the LDGC CAD-CAM crown group were observed (1-technical and 1-esthetic). The 6-year cumulative survival rates for MC crowns and LDGC CAD-CAM were 90.8% and 96%, respectively, whereas the success rates were 83.4% and 96%, respectively. Overall, patients preferred the esthetic outcomes of LDGC CAD-CAM crowns over MC crowns. CONCLUSION. The high survival and success rates, low number of complications, and the high level of patients' acceptance of monolithic LDGC CAD-CAM crowns lend them well as predictable and viable alternatives to the "gold standard" MC crowns.

CAD/CAM System을 활용하여 제작된 Coping Crown의 제작방식 및 재료에 따른 변연 적합도에 관한 연구 (The Study on Marginal discrepancy of Manufactured Coping Crown according to Production method and materials by using CAD/CAM System)

  • 이희성;신성훈;송준기
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.448-453
    • /
    • 2017
  • 본 연구는 CAD/CAM 시스템을 활용하여 제작방식 및 재료에 따른 Coping crown의 변연 적합도를 비교하여 최적의 제작방식 및 재료를 비교하고자 하였다. 제작방식 및 재료에 따른 코핑 크라운을 제작하였고, 리플리카 테크닉을 사용하여 변연적합도 측정을 실시하였다. 제작법과 재료에 따른 비교분석을 위해 이원배치분산 분석을 실시하였으며 서로 다른 평균값들의 비교 분석을 위해서 일원배치분산분석을 실시하였다. 연구결과 합금을 Milling법으로 제작한 MM군은 114.6, MS군은 111.4 값을 나타냈고, Milling/Sintering 법으로 제작한 MSC군은 67.2, MSS군은 50.9값을 나타냈고, Printing 법으로 제작한 SLME군은 100.5, SLMR군은 113.2값을 나타냈고, 세라믹의 Milling/Sintering 법으로 제작한 MSZ군은 35.6, MSC군은 36.3값을 나타냈고, 제작방식과 재료에 따른 이원배치분산분석 결과는 제작방식에에 따른 유의한 차이는 보이지 않았으나, 재료에 따른 유의한 차이는 나타내었다. 가장 높은 변연적합도를 보인 군은 세라믹 재료의 Milling/sintering 법이 가장 낮은 값을 보이며 최적의 방법으로 검증이 되었다. 그러나 CAD/CAM 시스템을 활용하여 제작된 Coping crown의 변연 적합도는 임상에서 허용이 가능한 수치값에 해당하므로 임상에 적용이 가능한 것으로 나타났다.

Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives

  • Goracci, Cecilia;Ozcan, Mutlu;Franchi, Lorenzo;Di Bello, Giuseppe;Louca, Chris;Vichi, Alessandro
    • 대한치과교정학회지
    • /
    • 제49권6호
    • /
    • pp.404-412
    • /
    • 2019
  • Objective: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment. Methods: Two types of PMMA blocks were tested: $CAD-Temp^{(R)}$ (VITA) and $Telio^{(R)}$ CAD (Ivoclar-Vivadent). The substrate was roughened with 320-grit sandpaper, simulating a fine-grit diamond bur. Two universal adhesives, Scotchbond Universal Adhesive (SU) and Assure Plus (AP), and a conventional adhesive, Transbond XT Primer (XTP; control), were used in combination with Transbond XT Paste to bond the brackets. Six experimental groups were formed: (1) $CAD-Temp^{(R)}/SU$; (2) $CAD-Temp^{(R)}/AP$; (3) $CAD-Temp^{(R)}/XTP$; (4) $Telio^{(R)}$ CAD/SU; (5) $Telio^{(R)}$ CAD/AP; (6) $Telio^{(R)}$ CAD/XTP. Shear bond strength and ARI were assessed. On 1 extra block for each PMMA-based material surfaces were roughened with 180-grit sandpaper, simulating a normal/medium-grit ($100{\mu}m$) diamond bur, and brackets were bonded. Shear bond strengths and ARI scores were compared with those of groups 3, 6. Results: On $CAD-Temp^{(R)}$ significantly higher bracket bond strengths than on $Telio^{(R)}$ CAD were recorded. With XTP significantly lower levels of adhesion were reached than using SU or AP. Roughening with a coarser bur resulted in a significant increase in adhesion. Conclusions: Bracket bonding to CAD/CAM PMMA can be promoted by grinding the substrate with a normal/medium-grit bur or by coating the intact surface with universal adhesives. With appropriate pretreatments, bracket adhesion to CAD/CAM PMMA temporary restorations can be enhanced to clinically satisfactory levels.

최근 치과용 지르코니아 CAD/CAM 수복물의 임상적 고찰 (A clinical consideration of current dental zirconia CAD/CAM restorations)

  • 이해형
    • 대한치과의사협회지
    • /
    • 제49권5호
    • /
    • pp.279-285
    • /
    • 2011
  • Currently there is no dental ceramic material can be used in all dental situations need to be restored. However, in view of recent clinical reports, the most viable alternative is zirconia ceramic. Clinical success of dental zirconia restorations strongly depends on proper selection of materials, accurate laboratory procedure and final cementation, which can be achievable with the correct understanding of zirconia. As dental materials, zirconia ceramics have a very bright future, because they are being used increasingly in the anterior region as implant fixtures, as well as crown and bridge restorations and implant abutments. Many dental ceramics showing poor clinical performance have been gone from the dental market. However, in terms of outstanding mechanical properties and esthetic nature, new dental materials can replace zirconia ceramics will not be available in the foreseeable future.

Mechanical Properties and Microstructure of the Leucite-Reinforced Glass-Ceramics for Dental CAD/CAM

  • Byeon, Seon-Mi;Song, Jae-Joo
    • 치위생과학회지
    • /
    • 제18권1호
    • /
    • pp.42-49
    • /
    • 2018
  • The computer-aided design/computer-aided manufacturing (CAD/CAM) system was introduced to shorten the production time of all-ceramic restorations and the number of patient visits. Among these types of ceramic for dental CAD/CAM, they have been processed into inlay, onlay, and crown shapes using leucite-reinforced glass-ceramics to improve strength. The purpose of this study was to observe the mechanical properties and microstructure of leucite-reinforced glass-ceramics for dental CAD/CAM. Two types of leucite-reinforced glass-ceramic blocks (IPS Empress CAD, Rosetta BM) were prepared with diameter of 13 mm and thickness of 1 mm. Biaxial flexural testing was conducted using a piston-on-three-ball method at a crosshead speed of 0.5 mm/min. Weibull statistics were used for the analysis of biaxial flexural strength. Fracture toughness was obtained using an indentation fracture method. Specimens were observed by field emission scanning electron microscopy to examine the microstructure of the leucite crystalline phase after acid etching with 0.5% hydrofluoric acid aqueous solution for 1 minute. The results of strength testing showed that IPS Empress CAD had a mean value of $158.1{\pm}8.6MPa$ and Rosetta BM of $172.3{\pm}8.3MPa$. The fracture toughness results showed that IPS Empress CAD had a mean value of $1.28{\pm}0.19MPa{\cdot}m^{1/2}$ and Rosetta BM of $1.38{\pm}0.12MPa{\cdot}m^{1/2}$. The Rosetta BM sample exhibited higher strength and fracture toughness. Moreover, the crystalline phase size and ratio were increased in the Rosetta BM sample. The above results are expected to elucidate the basic mechanical properties and crystal structure characteristics of IPS Empress CAD and Rosetta BM. Additionally, they will help develop leucite-reinforced glass-ceramic materials for CAD/CAM.

임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용 (Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner)

  • 박지만;박은진;허성주
    • 대한치과의사협회지
    • /
    • 제52권6호
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

심미보철 치료의 경향과 이해 : part 2. 지르코니아 (Understanding and trends of esthetic treatment in prosthodontics : part 2. Zirconia)

  • 강정인;허유리;이명선;손미경
    • 한국치위생학회지
    • /
    • 제14권5호
    • /
    • pp.617-622
    • /
    • 2014
  • With the explosive increase of esthetic demands by patients, many dental materials for the esthetic restoration have been introduced. Recently, zirconia based restorations are using for the cases of single crown, bridges, implant prostheses etc. Zirconia have superior mechanical properties and biocompatibility. Owing to the properties of high strength, zirconia has to be manufactured by CAD/CAM system. Dental CAD/CAM system is a futuristic treatment and technical system which makes it possible to produce the precision and uniform prosthesis and also standardize the treatments. This article introduces the characteristics of zirconia, fabrication procedure using CAD/CAM system and procedure for the cementation of zirconia based restoration.

CAD/CAM으로 제작된 임플란트 맞춤형 지대주의 방사선학적 평가 (Radiographic evaluation of computer aided design/computer aided manufacturing (CAD/CAM) customized abutment of implant)

  • 윤태경;이경제;정재헌;김희중
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.258-263
    • /
    • 2017
  • 목적: 이번 연구에서, 다양한 상황에서 골소실양을 평가하기 위하여 맞춤형 지대주를 사용한 환자에서 4년간의 후향적 방사선학적인 연구를 시행하였다. 대상 및 방법: 이번 연구의 대상은 CAD/CAM 맞춤형 지대주를 이용한 임플란트 고정성 보철물이다. 2011년 8월 1일부터 2012년 7월 31일 까지 조선대학교 치과병원 보철과에서 제작하여 고정성 보철물로 사용된 CAD/CAM 맞춤형 지대주와 상부 보철물들을 대상으로 하였으며, 고정성 보철물을 제작한 환자에 대하여 방사선학적 평가를 시행하여 보철물 장착 후 3개월, 6개월, 1년, 2년, 3년, 4년 단위로 총 4년 간의 후향적 연구를 시행하였다. 결과:연구 결과, CAD/CAM을 이용한 맞춤형 지대주는 기존 연구 결과에 비해 골소실 양이 적었다. 연결 고정된 그룹과 연결 고정되지 않은 그룹 간에 골소실 양(각각 0.27 mm, 0.5 mm)에 통계적으로 유의한 차이가 없었다. 또한 상악 전치부, 상악 구치부, 하악 전치부, 하악 구치부의 부위별 골소실양(각각 1.37 mm, 0.39 mm, 0.00 mm, 0.30 mm)에 통계적으로 유의한 차이가 있었다. 결론:CAD/CAM을 이용한 맞춤형 지대주는 연결 고정 여부에 따른 골소실 양에서 통계적으로 유의한 차이가 없었으며, 임플란트 식립 부위에 따른 골소실 양에서 통계적으로 유의한 차이가 있었다.

Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석 (Fit analysis of CAD-CAM custom abutment using micro-CT)

  • 민광석;정재헌;김희중
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.370-378
    • /
    • 2016
  • 목적: Biomet 3i 시스템과 Astra 시스템의 내측 연결형 임플란트 고정체에 국내에서 제작된 맞춤형 CAD-CAM 지대주를 체결하여 구성 성분 간의 적합성과 나사의 안정성을 평가하고자 하였다. 재료 및 방법: 24개 3i 임플란트 중 12개의 임플란트에 기성 지대주를 연결하고, 나머지 임플란트에는 맞춤형 CAD-CAM 지대주를 연결하여 각각 Group 1과 Group 2로 분류하였다. 동일 개수와 동일한 방법으로 Astra 임플란트를 각각 Group 3와 Group 4로 분류하였다. 각각의 고정체에 지대주를 장착하여 각 계면 사이의 적합성을 micro-CT로 관찰하고 초기 풀림 토크를 측정한 후 평가하였다. 결과: 고정체-지대주의 접촉길이는 Group 1과 Group 2 사이 뿐만 아니라 Group 3와 Group 4 사이에도 유의한 차이가 없었다(Mann-Whitney test, P>.05). 하지만, 지대주와 나사의 계면 및 고정체와 나사의 계면에서 Group 2와 Group 4가 Group 1와 Group 3에 비해 각기 더 큰 접촉양상을 보여주었다(Mann-Whitney test, P<.05). 또한, Group 2와 Group 4가 Group 1과 Group 3에 비해 각기 더 낮은 나사의 초기 풀림 토크를 기록하였다(Student t-test, P<.05). 결론: CAD-CAM지대주는 임상에 적용할 만한 적합성을 지니고 있으나, 광범위한 임상 적용을 위해서는 풀림 토크가 향상되어야 할 것으로 사료된다.