Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods (서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성)

  • Cho, Young Beom;Chae, Heon Chung;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.366-376
    • /
    • 2013
  • The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods. Zirconia coping was made by each CAD/CAM system followed by intra-oral scanning, model optical scanning and model contact scanning. It was embedded into Epoxy Resin and was cut by buccal to lingual. AMD (Absolute marginal discrepancy), MG (Marginal gap), GA (Gap of axial), GL (Gap of line angle) and GO (Gap of occlusal) of each sample were measured. The result is as followed; 1. The mean value of AMD in Group 1, Group 2, Group 3 are $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$. The averages of MG in Group 1, Group 2, Group 3 are $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$. Statistically there is no difference in AMD and MG among the three Groups (Anova, P>0.05). 2. GA of Group 2 revealed statistically difference compared with Group 1 and Group 3 (Anova, P<0.05). 3. GL and GO of Group 1 showed statistically significant differences compared with Group 2 and Group 3 (Mann-whitney test (P<0.05). Zirconia copings made by 3 ways of scanning methods have no difference with conventional ceramics in AMD and MG which are known as the most important factors.

Data Acquisition and Processing of 3D Object (3차원 물체의 데이터 획득 및 가공)

  • Yi, Kyoung-Woong;Choi, Han-Su;Kim, Nam-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.83-87
    • /
    • 2002
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts and processing 3D object have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Defective human teeth are usually ground to be coped with special alloy coping which is hand-made by dental technician. This make dental technician to be difficult and take a long time Dental CAD/CAM Systems consist of two parts, data acquisition and milling. In this paper, a method is studied to mill object which is acquired 3D geometric data of the small object such as a die in stone model. This paper present a control program and a mechanical system for milling 3D object.

  • PDF

Use of Intraoral Scanners for Fabricating Fixed Restoration: Clinical Tips (구강 스캐너를 사용한 고정성 보철 수복 시 고려사항)

  • Yoon, Hyung-In
    • The Journal of the Korean dental association
    • /
    • v.57 no.9
    • /
    • pp.524-528
    • /
    • 2019
  • With the advances of CAD-CAM (computer-aided design and computer-aided manufacturing) technology, the field of modern clinical dentistry has been dramatically changed. The first step in the digital workflow for tooth-supported dental prosthesis is a data acquisition with intraoral digital or conventional impression techniques. For the accuracy of intraoral digital impression data, the basic principles of conventional impression should be applied. It is necessary to obtain a good visibility with properly-dried field and well-exposed margin of the prepared abutment. Currently, the equi- or supra-gingival finish line can be recommended as an indication for intraoral digital impression. The scan data are generally exported to '.stl' file format, which has only morphological information of black and whitem while '.obj' file format can store data on color and texture.

  • PDF

3D Position Measurement & Coping using 2 CCD Cameras (2대의 CCD 카메라를 이용한 3차원 위치측정과 코핑)

  • Kang, Won-Chan;Shin, Suck-Doo;Kim, Young-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.2
    • /
    • pp.87-93
    • /
    • 2002
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, especially for system design, manufacturing and inspection. Two-camera method keeps accuracy more than double than mechanical method. In this paper, a new method is studied to acquire 3D geometric data of the small object such as a die in stone model. When the devices, cameras, laser beam and object are in a perfect plane, the calculation is measured by position error 0.025[mm] within. But this paper shows that arbitrarily positioned system can also be used to obtain 3D data. Also, this paper present a method to generate coping surface data with which CAM system can do for milling work.

Evaluation of validity of polyurethane model fabricated by intra-oral scanning method (구강 내 스캐닝 방법에 의해 제작된 폴리우레탄 모형의 정확도 평가)

  • Kim, Won-Tae;Lee, Byung-Ki;Hyun, Joung-Ku;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.91-96
    • /
    • 2014
  • Purpose: The purpose of this study was evaluate the validity of polyurethane model fabricated by intra oral scanning method. Methods: Ten sam cases of stone models were manufactured from master model, and polyurethane models were made with the intra oral scanning and CNC milling method. One examiner individually measured 6 distances(intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) on the stone models and the polyurethane models. The Mann-Whitney U test(${\alpha}$=0.05) were used for statistical analysis. Results: The mean difference between measurements made directly on the stone models and those made on the polyurethane models was 0.31-0.38mm. No statistically differences between the two groups were founded 4 distances(p>0.05), but 2 distances were statistically significant(p<0.05). Conclusion: Stone models showed larger than polyurethane models fabricated by intra oral scanning method.

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

Evaluation of biogeneric design techniques with CEREC CAD/CAM system

  • Arslan, Yeliz;Nemli, Secil Karakoca;Gungor, Merve Bankoglu;Tamam, Evsen;Yilmaz, Handan
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.431-436
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate occlusal contacts generated by 3 different biogeneric design modes (individual (BI), copy (BC), reference (BR)) of CEREC software and to assess the designs subjectively. MATERIALS AND METHODS. Ten pairs of maxillary and mandibular casts were obtained from full dentate individuals. Gypsum cast contacts were quantified with articulating paper and digital impressions were taken. Then, all ceramic crown preparation was performed on the left first molar teeth and digital impressions of prepared teeth were made. BI, BC, and BR crowns were designed. Occlusal images of designs including occlusal contacts were superimposed on the gypsum cast images and corresponding contacts were determined. Three designs were evaluated by the students. RESULTS. The results of the study revealed that there was significant difference among the number of contacts of gypsum cast and digital models (P<.05). The comparison of the percentage of virtual contacts of three crown designs which were identical to the contacts of original gypsum cast revealed that BI and BR designs showed significantly higher percentages of identical contacts compared with BC design (P<.05). Subjective assessment revealed that students generally found BI designs and BR designs natural regarding naturalness of fissure morphology and cusp shape and cusp tip position. For general occlusal morphology, student groups generally found BI design "too strong" or "perfect", BC design "too weak", and BR design "perfect". CONCLUSION. On a prepared tooth, three different biogeneric design modes of a CAD/CAM software reveals different crown designs regarding occlusal contacts and morphology.

Observation of Mechanical Strength of Materials for Dog Dental Prosthesis Production (중형견(犬) 치과 보철물 제작을 위한 소재의 기계적 강도 관찰)

  • Park, Yujin;Choi, Sungmin
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.93-100
    • /
    • 2019
  • Purpose: This study is making a dog dental prosthesis using digital dental technology. The mechanical strength of the prosthetic material was observed in terms of compressive strength and fracture pattern. Methods: The experiment was performed using dog mandibular molars. The teeth were scanned and modeled. The specimens were made of zirconia, PMMA and Ni-Cr. The specimens were subjected to a vertical compression test with an artificial cancellous bone in UTM tester. Vertical compressive strength and fracture behavior of specimen were observed. Results: The result of observing the compressive load between specimen and artificial bone were $184.8{\pm}5.7N$ in the zirconia specimen, $185.6{\pm}8.9N$ in the PMMA specimen, and $184.4{\pm}4.0N$ in the Ni-Cr alloy specimen. Compression marks of artificial bones were observed. The fracture strength of specimen was observed. The fracture strength of the zirconia specimen was an average of 1,381.4N. The fracture strength of the PMMA specimen was an average of 572.2N. Conclusion: The crown made of three kinds(zirconia, PMMA, Ni-Cr alloy) of materials has the strength to chew about the artificial bone. zirconia and PMMA have vertical compressive strength applicable to medium dog dental prosthetic materials.

Precision evaluation of crown prosthesis manufactured by two bur and three bur (2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가)

  • Kim, Chong-Myeong;Jeon, Jin-Hun;Lee, Jae-jun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{\pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{\pm}4.1{\mu}m$ and $19.1{\pm}2.8{\mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{\pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{\pm}1.9{\mu}m$ and $13.3{\pm}2.5{\mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.