Effect of $N_2$-backflushing Time in Carbon Ceramic UF & MF System for Paper Wastewater Treatment

  • Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.34-41
    • /
    • 2005
  • The wastewater discharged from a paper plant was filtrated by 3 kinds of tubular carbon ceramic UF and MF membranes with $N_2$-backflushing. The filtration time (FT) was fixed at 8 min or 16 min, and $N_2$-backflushing time (BT) was changed in 0${\~}$60 sec. The optimal condition was discussed in the viewpoints of total permeate volume ($V_T$), dimensionless permeate flux (J/Jo) and resistance of membrane fouling ($R_f$). In the viewpoints of $V_T$, J/Jo and $R_f$, the optimal $N_2$-BT was 40 sec at both FT for M9 (MWCO: 300,000 Daltons) and C005 ($0.05{\mu}m$) membranes. However, for C010 ($0.1{\mu}m$) it was 10 sec at FT=8 min, and 20 sec at FT=16 min in the viewpoints of J/Jo and $R_f$, and 5 sec at both FT in the viewpoints of $V_T$. It means that the short $N_2$-BT could reduce the membrane fouling and recover the permeate flux sufficiently for MF membrane having a large pore size as C010. Average rejection rates of pollutants were higher than $99.0\%$ for turbidity and $22.8{\~}59.6\%$ for $COD_{cr}$, but rejection rates of total dissolved solid (TDS) were lower than $8.9\%$. Therefore, the low turbidity water purified in our system could be reused for paper process.

Separation of chlorine in a uranium compound by pyrohydrolysis and steam distillation, and its determination by ion chromatography (열가수분해 및 수증기증류에 의한 우라늄 화합물 중 염소 분리 및 이온크로마토그래피 정량)

  • Kim, Jung-Suk;Lee, Chang-Hun;Park, Soon-Dal;Han, Sun-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.45-53
    • /
    • 2010
  • For the determination of chlorine in uranium compound, analytical methods by using a steam distillation and a pyrohydrolysis have been developed. The steam distillation apparatus was composed of steam generator, distilling flask and condenser etc. The samples were prepared with an aliquot of LiCl standard solution and a simulated spent nuclear fuel. A sample aliquot was mixed with a solution containing 0.2 M ferrous ammonium sulfate-0.5 M sulfamic acid 3 mL, phosphoric acid 6 mL and sulfuric acid 15 mL. The chloride was then distilled by steam at the temperature of $140^{\circ}C$ until a volume of $90{\pm}5\;mL$ is collected. The pyrohydrolysis equipment was composed of air introduction system, water supply, quartz reaction tube, combustion tube furnace, combustion boat and absorption vessel. The chloride was separated from powdered sample which is added with $U_3O_8$ accelerator, by pyrohydrolysis at the temperature of $950^{\circ}C$ for 1 hour in a quartz tube with a stream of air of 1 mL/min supplied from the water reservoir at $80^{\circ}C$. The chlorides collected in each absorption solution by two methods was diluted to 100 mL and measured with ion chromatography to determine the recovery yield. For the ion chromatographic determination of chlorine in molten salt retained in a metal ingot, the chlorine was separated by means of pyrohydrolysis after air and dry oxidation, and grinding for the sample.

Antimicrobial activity of epigallocatechin gallate from green tea (Camellia sinensis) on pathogenic Salmonella Enteritidis in braised quail eggs (메추리알 장조림에서 녹차 Epigallocatechin gallate (EGCG)의 Salmonella Enteritidis에 대한 저장 온도에 따른 항미생물 활성)

  • Kim, Kwang-Yeop;Kim, Young-Ji;Kim, Hong-Seok;Song, Kwang-Young;Kim, Dong-Hyeon;Lee, Mi-Young;Kim, Eui-Su;Jeong, Heon-Sang;Seo, Kun-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.329-334
    • /
    • 2016
  • The inhibitory effect of epigallocatechin gallate (EGCG), one of the antioxidants in green tea (Camellia sinensis), against Salmonella Enteritidis was evaluated in commercial braised quail eggs at two temperatures (4 and $25^{\circ}C$). Although S. Enteritidis was dose-dependently suppressed by EGCG in pure culture at $25^{\circ}C$, it was not inhibited in the sauce or eggs at this temperature. At low temperature ($4^{\circ}C$), S. Enteritidis was inhibited in both the sauce and eggs by $400{\mu}g/mL$ EGCG. Thus, EGCG at an appropriate concentration could be a useful food additive for inhibiting S. Enteritidis in braised quail eggs at low temperatures.

The Electrical Characteristics of the Grain Boundary in a $BaTiO_{3}$ PTC Thermistor ($BaTiO_{3}$ PTC 서미스터 입계의 전기적인 특성)

  • Kwon, Hyuk-Joo;Lee, Jae-Sung;Lee, Yong-Soo;Lee, Dong-Kee;Lee, Yong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.67-75
    • /
    • 1992
  • PTC thermistor has been fabricated with as-received $BaTiO_{3}$ powder and its electrical properties were investigated. The resistivity of the PTC thermistor was measured at $20^{\circ}C$ intervals from $20^{\circ}C$ to $200^{\circ}C$. The electrical characteristics of the PTC thermistor are determined by the ac complex impedance analysis. The average grain size measured with a scanning electron microscope increased from $3.8{\mu}m$ to $8.8{\mu}m$ with increasing sintering temperature between $1280^{\circ}C$ and $1400^{\circ}C$. The maximum resistivity jump was $4{\times}10^{5}$. The bulk resistivity of the thermistor sintered above $1340^{\circ}C$ decreased with increasing temperature of the measurement. The grain boundary resistance increased exponentially, the grain boundary capacitance decreased, and the built-in potential at the grain boundary increased with increasing temperature of the measurement. The charge densiy at the grain boundary increased with increasing temperature up to $110^{\circ}C$, which leveled off with further increase in measuring temperature.

  • PDF

Evaluation of Thermal Comfort in Ceiling Heating System (천장복사난방이 인체에 미치는 쾌적성 평가에 관한 연구)

  • 이주연;이소다노리오;조관식
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.104-108
    • /
    • 2001
  • 복사에 의한 냉난방은, 장시간 재실하는 방이나 소음, 기류에 민감한 장소에 적합하고 에너지 절약면에서도 유효한 냉난방 방식이라고 알려져 있다. 일반적으로 널리 알려져 있는 바닥난방은 실온의 수직분포가 균일함으로서 인체에 쾌적한 난방방식으로 알려져 있다. 이것에 비해, 바닥의외의 벽, 천장을 활용한 냉난방설비의 쾌적성에 대해서는 아직 충분히 검토되고 잇지 않다. 따라서 본 연구는 물순환식 복사 냉난방장치를 이용하여 겨울철의 천장복사난방이 인체에 미치는 생리적, 심리적영향을 밝히고 복사난방의 유용성에 대해서 검토하는 것을 목적으로 한다. 실험은 일본 나라여자대학 인공기후실을 이용하였고, 실험조건은 실온 18$^{\circ}C$, 21$^{\circ}C$, 24$^{\circ}C$ 천장온도 $25^{\circ}C$, 3$0^{\circ}C$, 35$^{\circ}C$의 조건을 조합하여 7조건으로 설정하였다. 또, 상대 습도 40%, 기류속도 0.1m/s 이하로 일정하게 유지시켰다. 생리적반응으로는 피부온14점과 직장온을 30초 간격으로 측정하였고, 혈압, 심박수, 체중, 체지방율을 측정하고 심리적반응으로는 온열감, 쾌적감등의 항목을 10분간격으로 측정하였다.

  • PDF

SUN INTERFEREN PREDICTIONS FOR THE KOMPSAT TT&C STATION

  • Lee, Byoung-Sun;Lee, Jeong-Sook
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.158-165
    • /
    • 1997
  • The Sun interference event predictions for the KOMPSAT TT&C station were performed to analyze the frequency of the event and the impact on the TT&C link. The KOMPSAT orbit was propagated including only J2 geopotential term for maintaining the Sun-synchronism and no other perturbations were included. Local time of ascending node of the KOMPSAT satellite was set to 10h50m00s. The TT&C station was assumed to locate in Taejon and have 9 meter antenna for S-band link. One year of simulation from 1999/07/01 were performed out of 3 year of mission lifetime of KOMPSAT satellite. Total four times of Sun interference events were occurred during 1 year of simulation and those lasted about 50 seconds altogether. The C/N degradation of the TT&C system was calculated about 4dB. The Sun interference event of 50 seconds of year are 0.0076 percents of the S-band contact time when the 30 minute of contact time is assumed in a day.

  • PDF

Preparation of BaTiO3 Powder in $BaO2-TiO2-Reduction Agent-PSCA (Particle Size Control Agent) System by SHS and Its Dielectric Properties (B3O2-TiO2-환원제-입자제어제계에서 자전연소합성법에 의한 BaTiO3분말의 제조 및 유전특성)

  • Yun, Ki-Seok;Lim, Sung-Jae;Nersisyan, Hayk;Won, Chang-Whan
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.11
    • /
    • pp.842-850
    • /
    • 2004
  • We have investigated on the preparation of BaTiO$_3$ powder at the system of BaO$_2$-TiO$_2$-Reduction ag.-PSCA by SHS. C and Mg were used as reduction agent, and NaCl was used as PSCA (Particle Size Control Agent). The effects of the various reduction agent and its concentration, particle size control agent, reaction mixture mass on the product in the preparation of BaTiO$_3$ powder at the optimum system by SHS were investigated. The optimum conditions for reaction system and composition were BaO$_2$+TiO$_2$+0.11 Mg +0.2C+0.75NaCl in the As atmosphere. NaCl as PSCA showed the effect of controlling the particle size of product as well as the combustion temperature. The particle size of BaTiO$_3$ synthesized at the optimum condition was about 0.5 ${\mu}{\textrm}{m}$. And as the mixture mass for the reaction was increased, the more stable combustion wave appeared. We have conducted the sintering experiment at the temperature of 130$0^{\circ}C$, the time of 2 h and the atmosphere of air to measure the dielectric properties of BaTiO$_3$ synthesised in this work, and the sample sintered in this condition showed 2,290 of dielectric constant at 10$0^{\circ}C$ and 13,890 at curie point (129$^{\circ}C$).

Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump (R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석)

  • Kang, Byun;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

Development of a Solar Collector Performance of Cylindrical Parabolic Concentrating Solar Collector (태양열(太陽熱) 집열기개발(集熱器開發)에 관(關)한 연구(硏究) - 포물반사곡면(抛物反射曲面)으로된 2차원(二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 성능분석(性能分析) -)

  • Song, Hyun Kap;Yon, Kwang Seok;Cho, Sung Chan
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.54-68
    • /
    • 1985
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. So far the concentrating solar collector has been developed to collect solar thermal energy at relatively high temperature, but it has some difficulties in maintaining the volumetric body of solar collector for long term utilization. On the other hand, the flat-plate solar collector has been developed to collect the solar thermal energy at low temperature, and it has advantages in maintaining the system for long term utilization, since it's thickness is thin and not volumetric. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolic concentrating solar collector was designed, which has two rows of parabolic reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The characteristics of the concentrating parabolic solar collector newly designed was analysed and the results are summarized as follows; 1. The temperature of the air enclosed in solar collector was all the same as $50^{\circ}C$ in both cases of the open and closed loop, and when the heat transfer fluid was not circulated in tubular absorber, the maximum surface temperature of the absorber was $118-120^{\circ}C$, this results suggested that the heat transfer fluid could be heated up to $118^{\circ}C$. 2. In case of longitudinal installation of the solar collector, the temperature difference of heat transfer fluid between inlet and outlet was $4^{\circ}-6^{\circ}C$ at the flow rate of $110-130{\ell}/hr$, and the collected solar energy per unit area of collector was $300-465W/m^2$. 3. The collected solar energy per unit area for 7 hours was 1960 Kcal/$m^2$ for the open loop and 220 Kcal/$m^2$ for the closed loop. Therefore it is necessary to combine the open and closed loop of solar collectors to improve the thermal efficiency of solar collector. 4. The thermal efficiency of the solar collector (C.P.C.S.C.) was proportional to the density of solar radiation, indicating the maximum thermal efficiency ${\eta}_{max}=58%$ with longitudinal installation and ${\eta}_{max}=45%$ with lateral installation. 5. The thermal efficiency of the solar collector (C.P.C.S.C.) was increased in accordance with the increase of flow rate of heat transfer fluid, presenting the flow rate of $110{\ell}/hr$ was the value of turning point of the increasing rate of the collector efficiency, therefore the flow rate of $110{\ell}/hr$ was considered as optimum value for the test of the solar collector (C.P.C.S.C.) performance when the heat transfer fluid is a liquid. 6. In both cases of longitudinal and lateral installation of the solar collector (C.P.C.S.C.), the thermal efficiency was decreased linearly with an increase in the value of the term ($T_m-T_a$)/Ic and the increasing rate of the thermal efficiency was not effected by the installation method of solar collector.

  • PDF

A Study of the Viscosity of Some Electrolytic Solutions and Its Concentration Function (電解質溶液의 粘度係數의 測定과 濃度關係에 對한 考察)

  • Sakong, Yull;Hwang, Jung-Eui
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 1964
  • The viscosities of strong electrolytic solutions, such as KCl, KI and NaI have been measured over a fairy wide range of concentration variation (from 0.00002 to 3.7M). It was hoped that a study of the data in the light of modern theories on solution might reveal new relation between viscosity and surface tension of electrolytic solution. To secure more accurate measurements of viscosity and surface tension of the solutions, Ostwald viscometer was made with pyrex glass and modified the timing system for the transit of the meniscus with a new electronics system and with a pulse counter. As the experimental data obtained were in good agreement with the Jone's values, Jones-Dole equations for the electrolytic solutions were deduced, ${\eta}KCl\;=\;1\;+\;0.0052{\sqrt{c}}\;-\;0.01612c\;+\;0.00808c^2\;at\;30^{\circ}C$ ${\eta}KI\;=\;1\;+\;0.0220{\sqrt{c}}\;-\;0.01290c\;+\;0.02988c^2\;at\;25^{\circ}C$${\eta}Na\; =\;1\;+\;0.0240{\sqrt{c}}\;-\;0.0640c\;+\;0.03268c^2\;at\;25^{\circ}C$Gruneisen effect appeared in the dilute solution, whereas anti-Gruneisen effect was found for the extremely dilute solution. No satisfactory interpretation for the variation of the viscosity with concentration can be found at the present.

  • PDF