• 제목/요약/키워드: C-scan

검색결과 781건 처리시간 0.036초

20대 빈약 유방 여성용 몰드 브래지어 컵의 형태 설계 방법 (Shape Design Method of Mold Brassiere Cup for Small-breasted Women in their Twenties)

  • 이현영
    • 한국의류산업학회지
    • /
    • 제17권6호
    • /
    • pp.988-995
    • /
    • 2015
  • Gaps between the upper edges of brassiere mold cups and the breasts are one of the most serious issues in realizing comfort wearing of commercial brassieres for small-breasted women. The surplus ease amounts causing the fit problem were measured from 3D wearing images of the small-breasted women's brassieres. The effect after the removing the surplus ease amounts from the upper edge of mold cup was approved by subjective wearing evaluation. Since the volume distribution of mold cup can also affect the wearing sensation of brassiere, the subjective wearing sensation was compared for two brassieres of different volume distributions, VL, of which volume was concentrated at the lower cup, and VC, which has the thickest part at the nipple. As the results, the suitable sensation for cup volume and the natural wearing silhouette could be accomplished by removing the surplus ease amounts from the upper edge of mold cup to reduce the gaps between brassieres and the breasts, which could be accomplished through an approach reducing the volume near the upper edge of mold brassiere cup and making the volume concentrated at the lower cup. These works provide a useful information on the design of the brassiere mold cups for small-breasted women. Moreover, modeling methods of 3D scan data and 3D printing technique for making more accurate mold cases used in this research can be helpful to develop and evaluate clothing products in future.

원형튜브 단면형상검사용 와전류탐촉자 개발 (Development of Eddy Current Test Probe for Profilometry Inspection of Tube)

  • 이희종;남민우;이진황
    • 비파괴검사학회지
    • /
    • 제17권4호
    • /
    • pp.262-269
    • /
    • 1997
  • 발전 설비중 열교환기 튜브와 같이 단면 형상이 원형인 부품의 원주 방향으로 마모, 침식 등에 의해 발생할 수 있는 단면 형상 변화를 검사(profilometry)하기 위한 와전류 탐촉자를 임피던스 등가회로이론을 적용하여 개발하였다. 본 연구에서는 외경 9.68mm, 벽두께 0.47mm인 SS304 튜브 외부에 발생할 수 있는 마모, denting 등의 결함을 모의한 시편을 제작하여 실험을 통해 검출 감도와 S/N비가 최적인 탐촉자의 코일치수, 전기적 특성, 적용 시험 주파수 등을 설정하였다. 이 결과에 따라 단면 형상 검사용 $8{\times}1$ 다중표면 탐촉자를 설계 제작하여 모의시편의 각 결함별 마모율을 검사한 결과 튜브 외부 발생 단면 형상 변화를 튜브외경의 ${\pm}0.2%$ (0.022mm) 측정 오차 범위로 측정이 가능함을 확인하였다.

  • PDF

일방성(一方性) 복함재료(複合材料)의 파괴거동(破壞擧動) 및 강도평가(强度評價)에 관(關)한 연구(硏究) (A Study on the Strength Evaluation of Unidirectional Carbon Fiber Reinforced Plastics by Nondestructive Method)

  • 장홍근;이주석;조경식;이승희;박은수
    • 비파괴검사학회지
    • /
    • 제7권2호
    • /
    • pp.42-47
    • /
    • 1988
  • 이상의 결과를 요약하면 다음과 같다. 1) 초음파 C-scan 법에 의하여 층간분리, 기지균열 등의 손상 정도, 크기 및 형태의 판별이 가능하며 충격손상은 주로 섬유의 주축방향으로 성장한다. 2) 복합재료의 인장파괴시 적층구조에 따라 상이한 AE 양상을 나타내며 이 원인은 파괴 mode의 차이에 기인한다. 3) 섬유의 파단은 기지파단의 경우 보다 강력한 AE activity를 나타내며 peak amplitude의 분포를 분석하여 파괴 mode의 해석이 가능하다. 4) 복합재료의 파괴강도는 적층구조, 충격 손상 등에 영향을 받으며 응력파 계수(SWF)의 측정에 의해 정성적 평가가 가능하다.

  • PDF

한 대학병원에서 급성 폐색전증으로 진단된 환자들의 임상적 특성 및 예후 (Acute Pulmonary Embolism: Clinical Characteristics and Outcomes in a University Teaching Hospital)

  • 채진녕;최원일;박지혜;노병학;김재범
    • Tuberculosis and Respiratory Diseases
    • /
    • 제68권3호
    • /
    • pp.140-145
    • /
    • 2010
  • Background: Pulmonary embolism (PE) is a common clinical problem in the West that is associated with substantial morbidity and mortality. The diagnostic modality has been changed since 2001. This study retrospectively reviewed the PE mortality with the aim of identifying the risk factors associated with mortality since the multidetector computed tomography (MDCT) was introduced. Methods: We analyzed 105 patients with acute PE proven by multidetector CT or ventilation perfusion scan. The primary outcome measure was the all-cause mortality at 3 months. The prognostic effect of the baseline factors on survival was assessed by multivariate analysis. Results: The main risk factors were prolonged immobilization, stroke, cancer and obesity. Forty nine percent of patients had 3 or more risk factors. The overall mortality at 3 months was 18.1%. Multivariate analysis revealed low diastolic blood pressure and the existence of cancer to be independent factors significantly associated with mortality. Forty two PE patients were examined for the coagulation inhibitors. Four of these patients had a protein C deficiency (9.5%), and 11 had a protein S deficiency (26%). Conclusion: PE is an important clinical problem with a high mortality rate. Close monitoring may be necessary in patients with the risk factors.

고체 고분자 전해질을 사용한 $V_{6}O_{13}$ Composite/Li Cell의 충방전 특성 (Charge/discharge Properties of $V_{6}O_{13}$ Composite/Li Cell with Solid Polymer Electrolyte)

  • 김종욱;유영한;정인성;박복기;구할본;문성인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1414-1417
    • /
    • 1996
  • The purpose of this study Is to research and develop $V_{6}O_{13}$ composite cathode for lithium thin film battery. $V_{6}O_{13}$ represents a class of cathode active material used in Li rechargeable batteries. In this study, we investigated cyclic voltammetry and charge/discharge characteristics of $V_6O_{13}$/SPE/Li cells. Cyclic voltammogram of $V_{6}O_{13}$/SPE/Li cell at scan rate 1mV/sec showed reduction peaks of 2.25V and 2.4V and oxidation peaks of 2.4V and 2.2V. The discharge curve of $V_{6}O_{13}$/SPE/Li cell showed 4 potential plateaus. The discharge capacity was decreased in the beginning of charge/discharge cycling. After 8th cycling, the discharge capacity was stable. The discharge capacity of 1st cycle and 15th cycle was 290mAh/g and 147mAh/g at $25^{\circ}C$, respectively.

  • PDF

Targeted Resequencing of 30 Genes Improves the Detection of Deleterious Mutations in South Indian Women with Breast and/or Ovarian Cancers

  • Rajkumar, Thangarajan;Meenakumari, Balaiah;Mani, Samson;Sridevi, Veluswami;Sundersingh, Shirley
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권13호
    • /
    • pp.5211-5217
    • /
    • 2015
  • Background: We earlier used PCR-dHPLC for mutation analysis of BRCA1 and BRCA2. In this article we report application of targeted resequencing of 30 genes involved in hereditary cancers. Materials and Methods: A total of 91 patient samples were analysed using a panel of 30 genes in the Illumina HiScan SQ system. CLCBio was used for mapping reads to the reference sequences as well as for quality-based variant detection. All the deleterious mutations were then reconfirmed using Sanger sequencing. Kaplan Meier analysis was conducted to assess the effect of deleterious mutations on disease free and overall survival. Results: Seventy four of the 91 samples had been run earlier using the PCR-dHPLC and no deleterious mutations had been detected while 17 samples were tested for the first time. A total of 24 deleterious mutations were detected, 11 in BRCA1, 4 in BRCA2, 5 in p53, one each in RAD50, RAD52, ATM and TP53BP1. Some 19 deleterious mutations were seen in patients who had been tested earlier with PCR-dHPLC [19/74] and 5/17 in the samples tested for the first time, Together with our earlier detected 21 deleterious mutations in BRCA1 and BRCA2, we now had 45 mutations in 44 patients. BRCA1c.68_69delAG;p.Glu23ValfsX16 mutation was the most common, seen in 10/44 patients. Kaplan Meier survival analysis did not show any difference in disease free and overall survival in the patients with and without deleterious mutations. Conclusions: The NGS platform is more sensitive and cost effective in detecting mutations in genes involved in hereditary breast and/or ovarian cancers.

Serum levels of interleukin-6 and interleukin-8 as diagnostic markers of acute pyelonephritis in children

  • Mahyar, Abolfazl;Ayazi, Parviz;Maleki, Mohammad Reza;Daneshi-Kohan, Mohammad Mahdi;Sarokhani, Hamid Reza;Hashemi, Hassan Jahani;Talebi-Bakhshayesh, Mousa
    • Clinical and Experimental Pediatrics
    • /
    • 제56권5호
    • /
    • pp.218-223
    • /
    • 2013
  • Purpose: Early diagnosis and treatment of acute pyelonephritis in children is of special importance in order to prevent serious complications. This study was conducted to determine the diagnostic value of serum interleukin (IL)-6 and IL-8 in children with acute pyelonephritis. Methods: Eighty-seven patients between 1 month to 12 years old with urinary tract infection (UTI) were divided into 2 groups based on the result of 99m-technetium dimercapto-succinic acid renal scan: acute pyelonephritis (n=37) and lower UTI (n=50) groups. White blood cell (WBC) count, neutrophil (Neutl) count, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) concentration, platelet count, and serum IL-6 and IL-8 concentrations of both groups were measured and compared. Results: There was a significant difference between two groups regarding WBC count, Neutl count, ESR, and CRP concentration (P<0.05). In addition, the difference between the two groups regarding serum IL-6 and IL-8 concentrations was not significant (IL-6, 60 and 35.4 pg/mL and IL-8, 404 and 617 pg/mL, respectively). The sensitivity and specificity of serum IL-6 and IL-8 for diagnosis of acute pyelonephritis were 73%, 42% and 78%, 32%, respectively. Sensitivity, specificity, negative and positive predictive values of serum IL-6 and IL-8 were less than those of acute phase serum reactants such as CRP. Conclusion: This study showed that there was no significant difference between acute pyelonephritis and lower UTI groups regarding serum IL-6 and IL-8 levels. Therefore, despite confirming results of previous studies, it seems that IL-6 and IL-8 are not suitable markers for differentiating between acute pyelonephritis and lower UTI.

MAGNETIC RESONANCE IMAGING을 이용한 악관절 원판 천공 진단 (PERFORATION OF THE TEMPOROMANDIBULAR JOINT MENISCUS: DIAGNOSED BY MAGNETIC RESONANCE IMAGING)

  • Kim, Houng-Gon;Dolan, Eward;Vogler, James B.;Nokes, Steven R.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제11권2호
    • /
    • pp.11-18
    • /
    • 1989
  • 최근의 악관절(TMJ) 방사선학적 진단에 있어 많은 발전과 진단방법이 고안돼어 왔다. 또한 새로운 외과적 술식의 발달로 인하여 악관절내장증(Internal Derangement)의 보다 정확한 진단을 요하게 되었다. 가장 새로운 진단방법으로 핵자기공명촬영법(Magnetic Resonance Imaging:MRI)이 악관절내장증 진단 평가하는데 사용되어지고 있다. 핵자기공명촬영법은 surface coil을 이용하여 관절원판(meniscus)의 비정상적 변화를 효과적으로 진달할 수 있으며, 지금까지 이용되어오던 악관절조영술(arthrography)이나 컴퓨터 단층촬영법(C-T scan)의 단점인, 관절내 조영제 주입이나 방사선 노출둥의 문제점을 배제할 수 있다. 본 연구는 악관절 핵자기공명촬영을 한 92명(184 joints)중 천공(perforation)으로 진단된 31 명 (39 joints)를 대상으로 하였으며, 핵자기공명촬영법의 취약점으로 지적되고 있는 악관절원판 천공 진단의 정확도를 측정하기 위하여 가역적 조사를 통해, 악관절원판 천공으로 진단되어 수술받은 15명(20 joints)에서 65%(13 joints)의 정확성을 확인하였다. 또한 핵자기공명촬영법을 통한 악관절원판 진단의 정확도를 높이기 위하여 condyle head의 퇴행성 변화, articular eminence의 변화, condyle spurring, bone to bone contact등의 경조직 변화와 meniscus의 discontinuity, meniscal deformity, loss of joint space, alternated bilaminar zone 등이 악관절원판 천공진단의 중요한 findings 임을 증명 하였다.

  • PDF

하이브리드 복합재료의 섬유배향각이 피로균열 및 층간분리 거동의 관계에 미치는 영향 (The Effect of Fiber Stacking Angle on the Relationship Between Fatigue Crack and Delamination Behavior in a Hybrid Composite Materials)

  • 송삼홍;김철웅
    • 대한기계학회논문집A
    • /
    • 제28권3호
    • /
    • pp.281-288
    • /
    • 2004
  • The hybrid composite material (Al/GFRP laminates) are applied to the fuselage and wing in a aircraft. Therefore, Al/GFRP laminates suffer from the cyclic bending moments. This study was to evaluate the effect of fiber stacking angle on the fatigue crack propagation and delamination behavior using the relationship between crack growth rate (da/dN) and stress intensity factor range (ΔK) in Al/GFRP laminates under cyclic bending moment. The variable delamination growth behavior in case of three different type of fiber orientations, i.e., [Al/O$_2$/Al], [Al/+45$_2$/Al] and [Al/90$_2$/Al] at the interface of Al layer and glass fiber layer was measured by ultrasonic C-scan images. As results of this study, It represent that the delamination shape should turns out to have more effective characteristics on the fiber stacking angle. The extension of the delamination zone in case of [Al/+45$_2$/Al] and [Al/90$_2$/Al] were not formed along the fatigue crack profile. The shape of delamination zone depend on fiber stacking angle and the variable type with the delamination contour decreased non-linearly toward the crack tip at the Al layer.

Surface Treatment Effect on Electrochemical characteristics of Al Alloy for ship

  • 이승준;김성종
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.149-149
    • /
    • 2017
  • Aluminum alloys have poor corrosion resistance compared to the pure aluminum due to the additive elements. Thus, anodizing technology artificially generating thick oxide films are widely applied nowadays in order to improve corrosion resistance. Anodizing is one of the surface modification techniques, which is commercially applicable to a large surface at a low price. However, most studies up to now have focused on its commercialization with hardly any research on the assessment and improvement of the physical characteristics of the anodized films. Therefore, this study aims to select the optimum temperature of sulfuric electrolyte to perform excellent corrosion resistance in the harsh marine environment through electrochemical experiment in the seawater upon generating porous films by variating the temperatures of sulfuric electrolyte. To fabricate uniform porous film of 5083 aluminum alloy, we conducted electro-polishing under the 25 V at $5^{\circ}C$ condition for three minutes using mixed solution of ethanol (95 %) and perchloric (70 %) acid with volume ratio of 4:1. Afterward, the first step surface modification was performed using sulfuric acid as an electrolyte where the electrolyte concentration was maintained at 10 vol.% by using a jacketed beaker. For anode, 5083 aluminum alloy with thickness of 5 mm and size of $2cm{\times}2cm$ was used, while platinum electrode was used for cathode. The distance between the two was maintained at 3 cm. Anodic polarization test was performed at scan rate of 2 mV/s up to +3.0 V vs open circuit potential in natural seawater. Surface morphology was compared using 3D analysis microscope to observe the damage behavior. As a result, the case of surface modification showed a significantly lower corrosion current density than that without modification, indicating excellent corrosion resistance.

  • PDF