• Title/Summary/Keyword: C-flux

Search Result 1,782, Processing Time 0.03 seconds

A Study on the Development of Industrial Dryer using the Superadiabatic Combustion Phenomena (초단열 연소현상을 이용한 산업용 건조기 개발에 관한 연구)

  • Chae, J.O.;Hwang, J.W.;Han, J.H.;Hwang, H.J.;Jun, J.K.;Han, J.O.;Lee, J.S.;You, H.S.;Lee, H.C.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.168-174
    • /
    • 2000
  • This paper illustrates the validity of reciprocating type superadiabatic combustor as a industrial applicable dryer. After the investigations of inner and surface temperature distributions of combustor various with air-fuel(methane) ratio, mixture flow rate and reciprocating time, this combustor can be applied in industrial dryer at certain operating conditions. The results are as follows. 1) Higher equilivalence ratio emits more radiation heat flux at the censer chamber 2) Higher mixture flow rate makes more uniform temperature distribution. however, due to the heat transfer from censer chamber to porous media, the radiation beat flux is worse. 3) Longer reciprocating time emit more radiation heat flux. however, this case also makes temperature distribution wide

  • PDF

Voltage Control Strategy for Maximum Torque Operation of Stator-Flux-Oriented Induction Machine Drive in the Field-Weakening Region (약계자 영역에서 유도 전동기의 고정자 자속 기준 최대 토크 운전을 위한 전압 제어 기법)

  • Kim, H.J.;Yu, J.S.;Won, C.Y.;Kim, E.J.;Jo, H.K.;Kim, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.30-32
    • /
    • 2005
  • In this paper, voltage control strategy for maximum torque operation of stator flux-oriented induction machine drive in the field-weakening region is proposed. In a conventional stator flux-oriented (SFO) induction machine drive system of the maximum torque capability cannot be obtained. The field-weakening method is used to vary the stator-flux reference in proportion to the inverse of the rotor speed. The proposed algorithm, based on the voltage control strategy, ensures the maximum torque operation over the field-weakening region. The proposed algorithm, voltage control strategy for maximum torque operation of capability, which is insensitive to the variation of machine parameters In the field-weakening region. The proposed algorithm is verified by simulation.

  • PDF

A Percentage Current Differential Relaying Algorithm for Bus Protection Using an Advanced Compensating Algorithm of the CTs (개선된 변류기 보상알고리즘을 적용한 모선보호용 비율전류차동 계전방식)

  • 강용철;윤재성;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.158-164
    • /
    • 2003
  • This paper proposes a percentage current differential relaying algorithm for bus protection using an advanced compensating algorithm of the secondary current of current transformers (CTs). The compensating algorithm estimates the core flux at the start of the first saturation based on the value of the second-difference of the secondary current. Then, it calculates the core flux and compensates distorted currents using the magnetization curve. The algorithm Is unaffected by a remanent flux. The simulation results indicate that the proposed algorithm can discriminate internal faults from external faults when the CT saturates. This paper concludes by implementing the algorithm into a TMS320C6701 digital signal processor. The results of hardware implementation are also satisfactory. The proposed algorithm can improve not only stability of the relay in the case of an external fault but sensitivity of the relay in the case of an internal fault.

A Study of Flow Condensation Inside Mini-Channels with Circular and Rectangular Cross Section (원형 및 사각단면의 미세채널내 흐름응축 열전달 연구)

  • Shin, Jeong-Seob;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1458-1463
    • /
    • 2004
  • By using unique experimental techniques and careful construction of the experimental apparatus, the characteristics of the local heat transfer were investigated using the condensing R134a two-phase flow, in horizontal single mini-channels. The circular channels ($D_h=0.493$, 0.691, and 1.067 mm) and rectangular channels ($D_h=0.494$, 0.658, and 0.972 mm) were tested and compared. Tests were performed for a mass flux of 100, 200, 400, and 600 $kg/m^2s$, a heat flux of 5 to 20 $kW/m^2$, and a saturation temperature of $40^{\circ}C$. In this study, effect of heat flux, mass flux, vapor qualities, hydraulic diameter, and channel geometry on flow condensation were investigated and the experimental local condensation heat transfer coefficients are shown. The experimental data of condensation Nusselt number are compared with existing correlations.

  • PDF

ASIG Design for Direct Torque Control of Induction Motor using VHDL (VHDL을 이용한 유도전동기의 직접 토크 제어 ASIC 설계)

  • Lee, H.J.;Kim, S.J.;Lee, B.C.;Kwon, Y.A.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.336-338
    • /
    • 2000
  • Recently many studies have been performed for variable speed control of induction motor. Direct Torque Control(DTC) is emerging technique for variable speed control of PWM inverter driven induction motor. DTC allows the direct control of stator flux and instantaneous torque through simple algorithm. In this paper ASIC design technique using VHDL is applied to DTC based speed control of induction motor. ASIC for DTC based speed control is designed through the description of coordinate transformation, speed controller stator flux and torque estimator, stator flux and torque controller, stator flux position detector. FSM(Finite State Machine) and inverter voltage switching vector. Finally the above system has been implemented on the FPGA (XC4052XL-PG411). Simulation and experiment has been performed to verify the performance of the designed ASTC.

  • PDF

Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-407C (혼합냉매 R-407C의 증발 열전달과 압력강하)

  • Roh, Geon-Sang;Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.542-549
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a horizontal copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300\;kg/m^2s$ and the saturation temperature of evaporator were $5^{\circ}C$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the increase of mass flux and vapor quality. The evaporation heat transfer coefficients of R-22 is about $5.68{\times}46.6%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is similar to that of R-407C. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of R-22 and R-407C. therefore, it is necessary to develope reliable and accurate predictions determining the evaporation heat transfer coefficient of R-22 and R-407C in a horizontal tube.

Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-22 and R-407C in a Diameter of 4.3 mm (4.3 mm 세관내 R-22와 R-407C의 증발 열전달과 압력강하)

  • Roh, G.S.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.4
    • /
    • pp.26-31
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a small diameter copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow mete, a condense and a double pipe type evaporate (test section). The test section consists of a smooth copper tube of 4.3 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^{2}s]$ and the saturation temperature of evaporator were $5[^{\circ}C]$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the Increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 is about $7.3\sim47.1%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is about $8\sim20%$ higher than that of R-407C.

  • PDF

Oxygen Permeation Properties of $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ Mixed-conducting Membrane (혼합전도성 $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ 분리막의 산소투과 특성)

  • Lim, Kyoung-Tae;Cho, Tong-Lae;Lee, Kee-Sung;Woo, Sang-Kuk;Park, Kee-Bae;Kim, Jong-Won
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.9
    • /
    • pp.787-793
    • /
    • 2001
  • $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ membranes were fabricated by solid-state reaction. We investigated sintering behavior and oxygen permeation flux as a function of time-on-stream, temperature and upstream oxygen partial pressure. The oxygen was permeated at temperatures form 750$^{\circ}$C to 950$^{\circ}$C by mixed conducting through oxygen vacancy diffusion in the dense membrane. The oxygen permeation flux through the membrane were about 0.1ml/$cm^3{\cdot}$min at 850$^{\circ}$C. A constant time was required for reaching stable oxygen flux, and oxygen partial pressure affected the oxygen permeation fluxes.

  • PDF

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Son Chang-Hyo;Kim Dae-Hui;Choi Sun-Muk;Kim Young-Ryul;Oh Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.167-174
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500kg/m^2s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greater effect on nucleate boiling than convective boiling. The evaporation heat transfer coefficient of $CO_2$ is highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But the existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

Downward particle flux in the eastern Bransfield Strait, Antarctica

  • Kim, Dongseon;Kim, Dong-Yup;Jeonghee Shim;Kang, Young-Chul;Kim, Taerim
    • Journal of the korean society of oceanography
    • /
    • v.38 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • A time-series sediment trap was deployed at a depth of 1034 m in the eastern Bransfield Strait from December 25, 1998 to December 24, 1999. Particle fluxes showed large seasonal variation; about 99% of the annual total mass flux (49 g m/sup -2/) was collected during the austral summer and fall (January-March). Settling particles consisted primarily of biogenic silica, organic carbon, calcium carbonate, and lithogenic material. Biogenic silica and lithogenic material predominated settling particles, comprising 36% and 30% of the total mass flux, respectively, followed by organic carbon, 11% and calcium carbonate, merely 0.6%. The annual organic carbon flux was 5.4 g C m/sup -2/ at 1000 m in the eastern Bransfield Strait, which is greater than the central Strait flux. The relatively lower flux of organic carbon in the central Bransfield Strait may be caused by a stronger surface current in this region. Organic carbon flux estimates in the eastern Bransfield Strait are the highest in the Southern Ocean, perhaps because of the fast sinking of fecal pellets, which leads to less decomposition of organic material in the water column. Approximately 5.8% of the organic carbon produced on the surface in the eastern Bransfield Strait is exported down to 1000 m; this percentage exceeds the maximum EF/sub 1000/ values observed in the Atlantic and Southern Oceans. The eastern Bransfield Strait appears to be the most important site of organic carbon export to the deep sea in the Southern Ocean.