• Title/Summary/Keyword: C-flux

Search Result 1,782, Processing Time 0.035 seconds

Summer-Time Behaviour and Flux of Suspended Sediments at the Entrance to Semi-Closed Hampyung Bay, Southwestern Coast of Korea (만 입구에서 부유퇴적물 거동과 플럭스: 한반도 서해 남부 함평만의 여름철 특성)

  • Lee, Hee-Jun;Park, Eun-Sun;Lee, Yeon-Gyu;Jeong, Kap-Sik;Chu, Yong-Shik
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.2
    • /
    • pp.105-118
    • /
    • 2000
  • Anchored measurements (12.5 hr) of suspended sediment concentration and other hydrodynamic parameters were carried out at two stations located at the entrance to Hampyung Bay in summer (August 1999). Tidal variations in water temperature and salinity were in the range of 26.0-27.9$^{\circ}C$ and 30.9-31.5, respectively, indicating exchange offshore and offshore water mass. Active tidal mixing processes at the entrance appear to destroy the otherwise vertical stratification in temperature and salinity in spite of strong solar heating in summer. On the contrary, suspended sediment concentrations show a marked stratification with increasing concentrations toward bottom layer. Clastic particles in suspended sediments consist mostly of very fine to fine silt (4-16 ${\mu}$m) with a poorly-sorted value of 14.7-25.9 ${\mu}$m. However, at slack time with less turbulent energy, flocs larger than 40 ${\mu}$m are formed by cohesion and inter-collision of particles, resulting in a higher settling velocity. Strong ebb-dominated and weak flood dominated tidal currents, in the southwestern and the northeastern part, respectively, result in a seaward residual flow of -10${\sim}$-20 cm $s^{-1}$ at station H1 and a bayward residual flow less than 5.0 cm $s^{-1}$ at station H2. However, mean concentration of suspended sediments at station H1 is higher at flood (95.0-144.1 mg $1^{-1}$) than in ebb (75.8-120.9 mg $1^{-1}$). On the contrary, at the station H2, the trend is reversed with higher concentration at the ebb (84.7-158.4 mg $1^{-1}$) than that at the flood (53.0-107.9 mg $1^{-1}$). As a result, seaward net suspended sediment fluxes ($f_{s}$) are calculated to be -1.7 ${\sim}$-$15.610^{3}$ kg $m^{-2}$ $s^{-1}$ through the whole water column. However, the stations H1 and H2 show definitely different values of the flux with higher ones in the former than in the latter. Alternatively, depth-integrated net suspended sediment loads ($\c{Q}_{s}$) for one tidal cycle are also toward the offshore with ranges of 0.37${\times}$$10^{3}$ kg $m^{-1}$ and 0.21${\times}$$10^{3}$ kg $m^{-1}$, at station H1 and H2, respectively. This seaward transport of suspended sediment in summer suggests that summer-time erosion in the Hampyung muddy tidal flats is a rather exceptional phenomenon compared to the general deposition reported for many other tidal flats on the west coast of Korea.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Pervaporation Separation of Ethanol Aqueous Solution through Carbonate-type Polyurethane Membrane II. The Effect of Pendent Anionic Group (카보네이트형 폴리우레탄막을 이용한 에탄올 수용액의 투과증발분리 II. 음이온성기에 의한 영향)

  • Han, In Ki;Oh, Boo Keum;Lee, Young Moo;Noh, Si Tae
    • Applied Chemistry for Engineering
    • /
    • v.3 no.4
    • /
    • pp.595-604
    • /
    • 1992
  • Carbonate-type polyurethane resins containing anionic moieties were systhesized from NCO-terminated prepolymer method. Membranes were manufactured from the polymer solution and the separation of aqueous ethanol solution was investigated. To enhance the property of urethane resin, carbonate-type polyol(PTMCG) was used. ${\alpha}^{\prime},{\alpha}^{{\prime}{\prime}}$-dimethylolpropionic acid was used as a chain extender to increase the hydrophilicily of the urethane membrane. The ionization of the pendent carboxylic groups in urethane resin was carried out using trimthylamine. To confirm the formation of anionic groups in urethane resin, IR spectra of model compounds were compared with those of urethane resins. It was confirmed that the concentration of hard segment and hydrogen bond contributed to the property of the concentration of hard segment and hydrogen bond contributed to the property of urethane resin in which the mole ratio of chain extender and polyol was from 3:1 to urethane resin in which the mole ratio of chain extender and polyol was from 3:1 to 5:1. The carbonate-type polyurethane containing pendent carboxylic grop(PU) had Tg of around-$25^{\circ}C$ and Tm, $45^{\circ}C$ measured by DSC. Transition temperatures of one containing pendent anionic group(APU) prepared from the ionization of PU shifted to $8{\sim}10^{\circ}C$ lower temperature region than those of PU. Pervaporation membrane was prepared through the casting method. N, N-dimethylformamide (DMF) were used as a solvent and hexamethylene diisocyanate(HMDl) as a crosslinking agent. Swelling degree increased with ethanol concentration in mixure and the control of the swelling degree of the membrane could be achieved by crossliking. The results of pervaporation were as follows : separation factor, 2.3~9.8 ; flux, $27{\sim}79.5g/m^2hr$. Pervaporation separation capacity could be enhanced by reducing the molecular weight of polyol from 2,000 to 1,000.

  • PDF

Effect of Shading Methods on Growth and Fruit Quality of Paprika in Summer Season (파프리카 여름재배시 차광방법이 생육과 과실특성에 미치는 영향)

  • Ha, Jun Bong;Lim, Chae Shin;Kang, Hyo Yong;Kang, Yang Su;Hwang, Seung Jae;Mun, Hyung Su;An, Chul Geon
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.419-427
    • /
    • 2012
  • This study was carried out to investigate the effect of two shading methods, shading agent spray on the glasshouse and internal shading screen treatment, on the growth and fruit quality of paprika (Capsicum annuum L. 'Cupra' and 'Coletti') in summer season cultivation. In the shading agent treatment, a commercial shading agent diluted with water at a ratio of 1 : 4 was sprayed on the roof of a glasshouse. In the internal shading screen treatment, a 10~20% shaded screen was used during the day time when the sun radiation was greater than $700W{\cdot}m^{-2}$. Compared to the unshaded control, photosynthetic photon flux density (PPFD) decreased in the greenhouse in the shading agent (SA) and shading screen (SS) treatments by 20% and 30%, respectively. Lower air temperatures and higher relative humidities were observed in the SA than in both the control and the SS treatment. Time to reach the break point of humidity deficit $8g{\cdot}m^{-3}$ was 2 hours late in the SA than in both the control and the SS treatment. Compared to control, both the SA and the SS treatments showed lower instantaneous temperatures of leaf, fruit, and flower by $2^{\circ}C$, $5^{\circ}C$ and $3^{\circ}C$, respectively. There were no differences in number of branches, stem diameter, and leaf size among treatments although both shading treatments promoted plant height in both cultivars. Botrytis infection ratio declined with the SA treatment by 14.7% in 'Cupra' and 22.1% in 'Coletti' as compared to that in the control. Shading increased fruit size in both cultivars, whereas no differences were observed in the number of locules and thickness of fruit tissue among treatments. Shading treatment increased mean fruit weight by a range of 10 to 15 g per fruit, while it decreased soluble solids contents as compared to that in the control. Similar Hunter values were observed among treatments, while fruit firmness increased slightly in shading treatments. Compared to the control, shading treatments improved marketable fruits by 11.7~22.6% and increased the number of fruits per plant by 4~9.2 in both 'Cupra' and 'Coletti'. The results of this study indicate that shading agent application on the roof of glasshouse would be one of the most effective options to reduce heat stress imposed on the paprika crop in summer cultivation, resulting in improved crop growth and fruit yield.

A Study on the Design Parameters of a Gasket and Innercase of a Refrigerator to Reduce Dew Generation on the Outer Surface (표면의 이슬 맺힘 저감을 위한 냉장고 가스켓 및 냉동냉장실 내벽 구조개선에 관한 연구)

  • Kang, Seok-Hoon;Kim, Seong-Jin;Kim, Ju-Hwan;Min, June-Kee;Sohn, Chang-Min;Park, Sang-Hu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.457-463
    • /
    • 2012
  • Current refrigerators are designed to have thin doors and walls to facilitate user convenience and increase inner storage space. However, the thin doors and walls gives rise to the problem of dew generation on the outer surface of a refrigerator due to a large critical temperature difference between the outer wall and the room air; So far, an electric heater is commonly used for making the dew to evaporate; in this case, the heater inevitably requires additional electrical power. We propose a new approach to reduce the dew generation in a refrigerator by redesigning the gasket and varying the thickness of the inner case of the refrigerator. The results of simulations performed in this study indicate that the surface temperature in the region where dew was generated was increased by approximately $0.39{\sim}3.07^{\circ}C$ without the use of a heater.

Growth Characteristics of Lettuce under Low Pressure (저압조건에서 상추의 생육 특성)

  • Park, Jong-Hyun;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.303-308
    • /
    • 2009
  • This study was conducted to analyze the feasibility of plant growth under low pressure and to investigate the effect of pressure on plant growth. Three levels of pressures (25, 50, and 101.3 kPa (control)) were provided to analyze the growth of Lettuce (Lactuca sativa L.) as affected by low pressure. Photoperiod, air temperature, and photosynthetic photon flux were set at 16/8 h, 26/$18^{\circ}C$, and $240{\mu}mol{\cdot}m^{-2}s^{-1}$, respectively. Growth characteristics of lettuce were measured on 7 days and 14 days after experiment. Leaf length, leaf width, leaf area, and root dry weight of lettuce measured on 7 days under 25 and 50 kPa were significant as compared to the control. Leaf length, top dry matter and root dry matter of lettuce measured on 14 days were significantly different under 25 and 50 kPa. From these results, we confirmed that lettuce could be grown under low pressure. However high relative humidity by evapotranspiration from leaves and growing beds under low pressure caused the condensation on the inner surface of the chamber. Therefore in a low pressure chamber, humidity control is required to maintain the relative humidity at a proper level.

Oxygen Permeation and Mechanical Properties of La0.6Sr0.4Co0.2Fe0.8O3-δ Membrane with Different Microstructures (미세구조에 따른 La0.6Sr0.4Co0.2Fe0.8O3-δ 분리막의 산소투과 및 기계적 특성)

  • Lee, Shi-Woo;Lee, Seung-Young;Lee, Kee-Sung;Woo, Sang-Kuk;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.994-1000
    • /
    • 2002
  • Oxygen permeability and the mechanical properties of mixed ionic-electronic conductive $La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_{3-{\delta}}$ perovskite-type membrane, fabricated by solid state reaction, were investigated with regard to microstructure. The microstructure of the membrane was controlled by changing the sintering temperature and holding time. The average grain size and relative density were evaluated as a function of sintering conditions. As the fraction of grain boundary decreased, oxygen permeability showed a tendency to increase. Especially the maximum oxygen flux of 0.37 ml/$cm^2$${\cdot}$min was measured for the specimen sintered at 1300${\circ}C$ for 10 h, which has high density and relatively large grain size. Fracture strength was dependent on the relative density of sintered body, while fracture toughness increased with average grain size.

A Study on the Inventory Estimation for the Activated Bioshield Concrete of KRR-2 (연구로 2호기 방사화 수조 콘크리트의 재고량 평가에 관한 연구)

  • Hong, Sang Bum;Seo, Bum Kyoung;Cho, Dong Keun;Jeong, Gyeong Hwan;Moon, Jei Kwon
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.202-207
    • /
    • 2012
  • The radioactivity inventory significantly affects all steps of decommissioning projects including planning, cost estimation, risk assessment, waste management and site remediation. The decommissioning project of the KRR-2 was completed in 2009 and a large amount of activated concrete waste was generated. The bioshield concrete, containing minute amount of impurity elements, was activated by neutron reaction during the operation of the reactor. A variety radionuclides was generated in the concrete, including $^3H$, $^{14}C$, $^{55}Fe$, $^{60}Co$ $^{63}Ni$, $^{134}Cs$, $^{152}Eu$ and $^{154}Eu$. In this paper, the comparison between the calculated results and previous measured results was carried out to estimate the inventory of the bioshield concrete of the KRR-2. The combined computer codes of MCNP5 and ORIGEN 2.1 for calculation of the distribution of neutron flux, cross-section and generation of radionuclides were used. The results were shown that 99.8% of the total radioactivity of $^3H$, $^{55}Fe$, $^{60}Co$ and $^{152}Eu$ in the bioshield concrete 12 years after shutdown. The effects on the variation of inventory were analysed depending on the operation periods and the cooling times in the bioshield concrete.

Study of Pool Boiling Heat Transfer on Various Surfaces with Variation of Flow Velocity (다양한 표면에서 유동 속도에 따른 풀 비등 열전달에 관한 연구)

  • Kang, Dong-Gyu;Lee, Yohan;Seo, Hoon;Jung, Dongsoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.343-352
    • /
    • 2013
  • In this study, a smooth flat surface, low fin, Turbo-B, and Thermoexcel-E surfaces are used to examine the effect of the flow velocity on the pool boiling heat transfer coefficients (HTCs) and critical heat fluxes (CHFs). HTCs and CHFs are measured on a smooth square heater of $9.53{\times}9.53mm^2$ at $60^{\circ}C$ in a pool of pure water at various fluid velocities of 0, 0.1, 0.15, and 0.2 m/s. Test results show that for all surfaces, CHFs obtained with flow are higher than those obtained without flow. CHFs of the low fin surface are higher than those of the Turbo-B and Thermoexcel-E surfaces due largely to the increase in surface area and sufficient fin spaces for the easy removal of bubbles. CHFs of the low fin surface show even 5 times higher CHFs as compared to the plain surface. On the other hand, both Turbo-B and Thermoexcel-E surfaces do not show satisfactory results because their pore sizes are too small and water bubbles easily cover them. At low heat fluxes of less than $50kW/m^2$, HTCs increase as the flow velocity increases for all surfaces. In conclusion, a low fin geometry is good for application to steam generators in nuclear power plants.

Effects of Light-emitting Diodes on In Vitro Growth of Virus-free Sweet Potato Plantlets (LED가 고구마 바이러스 무병묘의 기내 생장에 미치는 영향)

  • Yoo, Kyoung-Ran;Lee, Seung-Yeob
    • Horticultural Science & Technology
    • /
    • v.35 no.4
    • /
    • pp.490-498
    • /
    • 2017
  • The in vitro growth of virus-free sweet potato [Ipomoea batatas (L.) Lam.] plantlets was investigated under different light sources: fluorescent lamp (control); red (660 nm), blue (460 nm), white light-emitting diodes (LED), and two mixtures of blue and red LED (R:B = 8:2, and 7:3). Single node explants (10 mm) of three cultivars ('Matnami', 'Shincheonmi', and 'Yeonhwangmi') were cultured on Murashige and Skoog medium supplemented with $0.2mg{\cdot}L^{-1}$ 6-benzyladenine for 4 weeks. Explants were exposed to $150{\pm}5{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ photosynthetic photon flux at a distance of 20 cm, constant temperature of $25^{\circ}C$, and under 16/8-h (day/night) photoperiod. Using the same method, the in vitro growth of 10 cultivars under red LED was also compared. After 3 weeks, vine length was highest in plantlets cultured under red LED, and lowest in plantlets cultured under blue LED. Fresh and dry weights were also greatest in plantlets cultured under red LED. Compared to the control, vine thickness was significantly higher in plantlets grown under white LED and the 7:3 R:B LED mixture. Significant differences were observed among the 10 cultivars grown under red LED. 'Matnami', 'Shincheonmi', and 'Shinhwangmi' all had excellent vine lengths, and fresh and dry weights. Compared to the control, vine elongation of sweet potato plantlets was most effective under red LED, and culture duration was about 1 week shorter.