• Title/Summary/Keyword: C-flux

Search Result 1,782, Processing Time 0.029 seconds

Sensitivity Study of the Flow-through Dynamic Flux Chamber Technique for the Soil NO Emissions

  • Kim Deug-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E3
    • /
    • pp.75-85
    • /
    • 2005
  • A mathematical sensitivity analysis of the flow-through dynamic flux chamber technique, which has been utilized usually for various trace gas flux measurement from soil and water surface, was performed in an effort to provide physical and mathematical understandings of parameters essential for the NO flux calculation. The mass balance equation including chemical reactions was analytically solved for the soil NO flux under the steady state condition. The equilibrium concentration inside the chamber, $C_{eq}$, was found to be determined mainly by the balance between the soil flux and dilution of the gas concentration inside the chamber by introducing the ambient air. Surface deposition NO occurs inside the chamber when the $C_{eq}$ is greater than the ambient NO concentration ($C_{0}$) introducing to the chamber; NO emission from the soil occurs when the $C_{eq}$ is less than the ambient NO concentration. A sensitivity analysis of the significance of the chemical reactions of NO with the reactive species (i.e. $HO_{2},/CH_{3}O_{2},/O_{3}$) on the NO flux from soils was performed. The result of the analysis suggests that the NO flux calculated in the absence of chemical reactions and wall loss could be in error ranges from 40 to $85\%$ to the total flux.

Effect on Boiling Bleat Transfer of Horizontal Micro-channel Diameters for R-22 and R-407C (수평미세관의 직경이 R-22 및 R-407C 비등열전달에 미치는 영향)

  • Yoon, Kuk-Young;Choi, Kwang-Il;Oh, Jong-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.163-172
    • /
    • 2003
  • Boiling heat transfer coefficients and pressure drops for R-22 and R-407C were measured in horizontal micro-channels. The test section is stainless steel tube, inner tube diameters are 1.8mm and 2.8mm, and the respective lengths are 1500mm and 3000mm. The range of mass flux is 300-600kg/$m^2$s and heat flux is 5-15kW/$m^2$. In this results, pressure drop increased linearly for both R-22 and R-407C with increased mass flux, but the increase of heat flux did not affect the pressure. In addition, the pressure drop was fairly increased in the high quality region rather than low quality region. In the range of low quality, the mass flux had a small affect on the heat transfer coefficients, however, in high quality region, the heat transfer coefficients increased even more with increasing mass flux. Under the low quality region and low mass flux, the heat transfer coefficients increased with increasing heat flux densities. The effects of inner tube diameter were clearly observed. Namely, the measured pressure drop inside inner tube diameter 1.8 mm is higher than 2.8 mm with increasing the mass flux and heat flux. Also, the measured local heat transfer coefficient inside inner tube diameter 1.8 mm is higher than 2.8 mm in the range of high qualities. The experimental data for R-407C compared with proposed correlation using pure refrigerant. The experimental data for R-407C was more decreased than the proposed correlation for pure refrigerant up to 50% or more.

A Study on Ignitability and Heat Release Rate Characteristics of Rigid Polyurethane Foam (경질 폴리우레탄폼의 착화성 및 열방출특성 연구)

  • 공영건;이두형
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.117-123
    • /
    • 2003
  • In this study; the ignition and heat release rate characteristics of rigid polyurethane foam were investigated in accordance with setchkin ignition tester and cone calorimeter which is using oxygen consumption principle. In the ignition temperature study; flash-ignition temperature was $383^{\circ}C$-$390^{\circ}C$, self-ignition temperature was$ 493^{\circ}C$∼495$^{\circ}C$. The self-ignition temperature of rigid polyurethane foam was about $100^{\circ}C$ higher than the flash-ignition temperature. In the cone calorimeter study, the time to ignition of rigid polyurethane foam was faster as the external heat flux increase. In the same heat flux level, the time to ignition was faster as the density of rigid polyurethane foam decrease. Also the heat release rate was the largest value at the heat flux of /$50 ㎾\m^2$ and had a tendency of increase as the heat flux level and density increase. In the standpoint of time to ignition and heat release rate, the fire performance of rigid polyurethane foam was influenced by the applied heat flux level and density and the flashover propensity classified by Petrella's proposal was high.

Effect of Flux Composition on Weld Metal Toughness and Workability in Submerged Aye Welding with 60kgf/$\textrm{mm}^2$ Grade C-Mo Type Wires (60kgf/$\textrm{mm}^2$급 C-MO계 와이어를 사용한 서브머지드 아크 용접금속 인성 및 작업성에 미치는 플럭스 조성의 영향)

  • 방국수;안영호
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.93-100
    • /
    • 1996
  • Effect of a flux composition on weld metal toughness in submerged arc welding with 60kgf/$\textrm{mm}^2$ grade C-Mo type wires was investigated and interpreted in terms of weld metal microstructure and hardenability. Flux workability was also studied by characterizing a weld bead profile. Compared to other weld metals, .weld metal used alumina basic flux with nickel showed lowest oxygen content, highest hardenability and the most acicular ferrite. The highest impact toughness of that weld metal, however, was attributed to the tough matrix due to the nickel rather than to the larger amount of acicular ferrite. Manganese silicate flux had better workability than alumina basic flux, showing broader welding conditions resulting in a depth-to-width ratio of 0.5. The composition of oxides in the weld metal was dependent on the flux composition, showing MnO-SiO$_2$-TiO in manganese silicate flux and MnO-SiO$_2$-Al$_2$O$_3$-TiO in alumina basic flux. MnO-SiO$_2$composition in both oxides was similar to a tephroite.

  • PDF

Iontophoretic Delivery of Vitamine C-2-phosphate from Carbopol Hydrogel (하이드로겔을 이용한 비타민 C-인산염의 이온토포레시스 피부투과)

  • Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.159-166
    • /
    • 2007
  • In order to develop an optimum formulation for iontophoretic delivery of vitamine C-2-phosphate (VCP) from Carbopol hydrogel, we have investigated various factors which can affect the iontophoretic flux through skin. Such factors as drug concentration, current density, current profile, current duration, ionic strength, pH and percutaneous enhancers (ethanol, glycerine, propylene glycerol, sorbitol, urea) were studied. Compared to the flux by passive or anodal delivery, the flux by cathodal delivery increased markedly, and thus, only cathodal delivery was used in the rest of the flux experiments. Flux increased linearly as the drug concentration and current density increased. As the duration of current application increased from 30 min to 120 min, flux increased linearly, however the AUC was not directly proportional to the applied amount of current. Flux also increased as the pH increased, possibly due to the increase in ionization of phosphate group. As the ionic strength increased, flux decreased. No significant increase in flux was observed after enhancer application, indicating that the effect of current on flux is dominating over the effect of percutaneous enhancers (P>0.05). These results provide important informations that are needed for optimal formulation of iontophortic delivery for VCP.

Ammonia Flux from Cow Manure in Relation to the Environmental Factors in Livestock Facilities (축산분뇨에서 발생하는 암모니아 플럭스에 대한 환경인자의 영향에 관한 연구)

  • Sa, Jae-Hwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.432-442
    • /
    • 2010
  • Ammonia is a very important constituent of the atmospheric environment because it is the most dominant gaseous alkaline species present in the atmosphere. Ammonia is known to affect ecosystems at relatively low concentration. Ammonia flux from livestock facilities can be regulated by a number of environmental factors (pH, ammonium ion, temperature, wind speed, etc). The increases in wind speed above manure from 0.0 m/s to 1.0 7m/s resulted in 2.5 times increases in ammonia flux. Wind speed and ammonia flux showed 0.982. A linear relationship with a correlation coefficient (r=0.982). When manure temperature increased from $3^{\circ}C$ to $36^{\circ}C$, the manure pH decreased approximately 0.30 to 0.46. As wind speed above the manure increased from 0.0 m/s to 1.07 m/s, ammonia flux increased approximately 2.5 times. The increasing manure temperature from $3^{\circ}C$ to $10^{\circ}C$, raised ammonia flux from 2.0 to 3.6 times (2.6 times in average similarly). The increases of manure temperature from $3^{\circ}C$ to $25^{\circ}C$ increased ammonia flux from 5.7 to 12.9 times (8.5 times in average). In this study, the correlation coefficient between ammonia flux and manure temperature was found from 0.972 to 0.989. Results of our research showed that ammonium ion concentration, pH of manure and wind speed were important factors in controlling the ammonia flux from manure livestock facilities.

Improved Flux Estimation Method for Speed Sensorless Control of Induction (개선된 자속추정 방식에 의한 유도전동기의 속도 센서리스 제어)

  • Seo, Young-Su;Joe, Moon-Taek;Kim, Young-Chun;Kim, Jin-Taek
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2005-2007
    • /
    • 1998
  • The rotor speed flux information most important in the speed sensorless vector c So in the paper used current voltage model for flux information in a induction motor. Voltage realized low pass filter insted of integrator, c model realized used of current equation. And cur voltage model estimated flux compoed of Pl cont For conpensation of estimated flux error conpansation algorithm using exactly, rapidly flux obtained for conpensation of estimated flux Proposed control system used TMS320C31 DS high speed processing. The effectiveness of proposed method is verified by simulation experimental results. This method shows h characteristic speed estimation highly flux esti and stable, robust character of load regulation.

  • PDF

Solid Phase Crystallization of LPCVD Amorphous Silicon Thin Films by Alternating Magnetic Flux (교번자속인가에 의한 비정질 실리콘 박막의 결정화거동에 대한 연구)

  • 송아론;박상진;박성계;남승의;김형준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.459-462
    • /
    • 2000
  • A new method for the fabrication of poly-Si films is reported using by alternating magnetic flux crystallization (AMFC) of LPCVD a-Si films. In this work we have studied the crystallization of LPCVD a-Si films by alternating magnetic flux. A-Si films were 1200$\AA$-thick deposited at 48$0^{\circ}C$ at a total pressure of 0.25Torr using Si$_2$H$_{6}$/H$_2$. After this step, these a-Si films were thermally annealed by Alternating Magnetic Flux at 43$0^{\circ}C$ for 1hours. The annealed films were characterized using X-ray diffraction (XRD), Raman Spectra, Atomic Force Microscopy(AFM). Both alternating magnetic flux crystallization and solid phase crystallization were investigated to compare enhanced crystallization a-Si. We have found that the low temperature crystallization method at 43$0^{\circ}C$ by alternating magnetic flux.x.

  • PDF

Iontophoretic Delivery of Vitamine C 2-Phosphate (이온토포레시스를 이용한 2-인산 비타민 C의 피부투과)

  • Kim, Su-Youn;Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.3
    • /
    • pp.201-207
    • /
    • 2004
  • In order to develop an optimum formulation for iontophoretic flux of vitamine C 2-phosphate (VCP), we have prepared three different hydrogels containing VCP, using carbopol, HPMC and poloxamer, and iontophoretic flux through hairless mouse skin from these hydrogels was carried out. Drug stability in phosphate buffer (PBS) solution (pH 7.4) with and without current application was studied. The effect of various factors, such as drug concentration, current density, and current profile on skin flux was also investigated. Stability study indicated that VCP in PBS (pH 7.4) solution was stable under the experimental condition, irrespective of the presence of current. Cathodal delivery increased the flux markedly, whereas the anodal and passive flux was negligible. Thus, cathodal delivery was used in all experiments. Flux increased as the drug concentration (2.5, 5.0, 7.5%) and current density $(0.2,\;0.4,\;0.6\;mA/cm^2)$ increased. Pulsed application of the current showed lower flux than constant current application. The results obtained suggest that VCP can be delivered into the skin and the amount delivered can be controlled by varying hydrogel, current density, drug concentration and current application profile.

Effect of Pb based flux on the Microwave Dielectric Properties of PCFN-PZW System (PCFN-PZW계의 마이크로파 유전 특성에 미치는 Pb계 Flux의 영향)

  • 강동헌;설충의;차훈주;김영호;길상근;조봉희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1027-1032
    • /
    • 2002
  • (Pb$\_$0.4/Ca$\_$0.6/)(Fe$\_$1/2/Nb$\_$1/2/)O$_3$ system was modified by 10 mol% Pb(Zn$\_$1/2/W$\_$1/2/)O$_3$ addition and their sinterability and microwave properties were investigated as a function of the amount of flux (0.975PbO-0.025SnO$_2$). With increasing flux content, single perovskite phase was maintained up to 3 wt% flux addition and further addition led to the presence of Pb-rich second phase which was confirmed by EDS analysis. The apparent densities of PCFN-PZW specimen increased and showed maximum values at 2.5 wt% flux addition for the Ts=1000$^{\circ}C$ and 2.0wt% flux addition for the Ts=1050$^{\circ}C$, respectively. The dielectric constant and Q$.$f values strongly depended on the variation of density and microstructure, where the optimum values of $\varepsilon$$\_$r/ = 91.95, Q$.$f = 5938GHz, TCF = +8.15ppm/$^{\circ}C$ were obtained for the 2.5wt% flux added PCFN-PZW specimen sintered at 1000$^{\circ}C$ for 4h.