• Title/Summary/Keyword: C-arm

Search Result 698, Processing Time 0.026 seconds

The Optimal Shock Intensity and C-arm Total Running Time in Patients with Inferior Ureter Stones during Electromagnetic of ESWL (전자기식 체외충격파쇄석술시 하부요관 결석 환자에 대해 적합한 충격강도와 C-arm 총 가동시간)

  • Park, Jeong Kyu;Cho, Euy Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.461-466
    • /
    • 2014
  • The advantages and disadvantages of the various models of crushed ESWL (Extracorporeal Shock Wave Lithotripsy) and their various side effects due to pre-treatment have been reported. We look for the appropriate intensity of the shock wave in the electromagnetic ESWL treatment of patients with lower Inferior Ureter Stones and measure the total running time of C-arm saw. This study is based on the January-June 2014 launch of 65 patients of C university hospital located in Gyeongbuk, who conducted ESWL without pre-treatment. Patients are composed of 48 male and 17 female which were more common in men, while the most common age is 50s. The occurrence of lower urinary tract stones were left and they were more absent than 5mm in size in 39 of the most common. Optimal intensity is one of the suitable intensity of pain, and it is possible to switch the strength of impact to C if one appeals pain. In addition, the C-arm of the total operating time showed $241.73{\pm}30.37$ seconds, which is the size of the lower urinary tract that showed a significant difference (p <0.05). Therefore, ESWL treatment without pre-enforce treatment, the standard for the impact frequency and impact strength depending on the site of ureteral stones is required. The standard for total operating time of C-arm generated for ureteral stones is needed in order to reduce radiation exposure, and the standard for the total operating time for the criteria is needed depending on the site in order to minimize the exposure.

Method for C-arm Based Guide Needle Insertion Assistant System for Endoscopic Disc Surgery (C-arm 영상 기반 척추 디스크 내시경 수술을 위한 가이드 바늘 삽입 보조 시스템)

  • Yoon, Hyon Min;Cho, Hyunchul;Park, Kyusic;Shin, Sangkyun;Lee, Deukhee
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.3
    • /
    • pp.263-268
    • /
    • 2015
  • Due to an increased sitting time in work, lumbar disc disease is one of the most frequent diseases in modern days, and this occasionally requires surgery for treatment. Endoscopic disc surgery, one of the common disc surgeries, requires a process of inserting a guide needle to the target disc for which the insertion path is manually planned by drawing lines on the patient's skin while monitoring the fluoroscopic view of the lumbar. Such procedure inevitably exposes both surgeon and patient to the fluoroscopy radiation emitted from the c-arm for a long time. To reduce the radiation exposure time, this study proposes a computer assisted method of calculating the 3D guide needle path by using 2D c-arm images of the disc in 3 different angles. Additionally, a method of the guide robot control based on the 3D needle path was developed by implementing the Hand-eye Calibration method to calculate the transformation matrix between the c-arm and robot base coordinate systems. The proposed system was then tested for its accuracy.

Design and Implementation of ARM based Network SoC Processer (ARM 기반의 네트워크용 SoC(System-on-a-chip) 프로세서의 설계 및 구현)

  • 박경철;나종화
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04d
    • /
    • pp.286-288
    • /
    • 2003
  • 본 논문에서는 서로 다른 네트워크간의 다양한 프로토콜과 이종의 트래픽을 동시에 처리할 수 있는 네트워크용 SoC (System-on-a-Chip) 프로세서를 구현하였다. 제작된 네트워크 SoC 프로세서는 ARM 프로세서 코어와 ATM(Asynchronous Transfer Mode) 블록, 10/100 Mbps 이더넷 볼록, 스케쥴러, UART 등을 이용하였고 각 블록은 AM8A (Advanced Microcontroller Bus Architecture) 버스로 연결하였다. SoC 프로세서는 CADENCE사의 VerilogHDL을 이용하여 설계하였고 0.35$\mu\textrm{m}$ 셀 라이브러리를 이용하여 검증하였다. 구현된 칩은 총 게이트수가 312,000개이며 칠의 최대 동작 주파수는 50MHz 이다.

  • PDF

Embedded ARM based SoC Implementation for 5.8GHz DSRC Communication Modem (임베디드 ARM 기반의 5.8GHz DSRC 통신모뎀에 대한 SOC 구현)

  • Kwak, Jae-Min;Shin, Dae-Kyo;Lim, Ki-Taek;Choi, Jong-Chan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.185-191
    • /
    • 2006
  • DSRC((Dedicated Short Range Communication) is dedicated short range communication for wireless communications between RSE(Road Side Equipment) and OBE(On-Board Unit) within vehicle moving high speed. In this paper, we implemented 5.8GHz DSRC modem according to Korea TTA(Telecommunication Technology Association) standard and investigated implementation results and design process for SoC(System on a Chip) embedding ARM CPU which control overall signal and process arithmetic work. The SoC is implemented by 0.11um design technology and 480pins EPBGA package. In the implemented SoC ($Jaguar^{TM}$), 5.8GHz DSRC PHY(Physical Layer) modem and MAC are designed and included. For CPU core ARM926EJ-S is embedded, and LCD controller, smart card controller, ethernet MAC, and memory controller are designed as main function.

Closed Manual Reduction of Mandibular Condylar Fracture Assisted by C-arm Fluoroscopy (C-arm 형광투시를 이용한 하악관절돌기골절의 비관혈적 도수정복)

  • Choi, Eui Chul;Kang, Sang Gue;Jung, Sung Gyun
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.131-134
    • /
    • 2009
  • Purpose: Mandible fractures are common in maxillofacial trauma and the incidence of condylar fracture is high. The management of mandibular condylar fracture continues to be controversial. Conservative treatment of it may lead to complications such as asymmetry, malocclusion, temporomandibular joint dysfunction. Moreover, open reduction can cause facial nerve injury, parotid gland injury, scarring and hematoma formation. We present a case of mandibular condylar fracture that was treated by manual reduction without incision under C-arm fluoroscopy. Methods: A 76-year-old female was admitted due to left side mandibular condylar fracture that required surgical intervention. Because of her age, history of diabetes mellitus, hypertension, she underwent closed manual reduction under general anesthesia. We adopted C-arm fluoroscopy as a method of identifying the fracture site and a evaluation of reduction state. C-arm fluoroscopy was set up like modified Towne's view. Results: The reduction was successful and didn't result in any complications that could occur in open reduction-facial nerve injury, infection, parotid gland injury, hematoma, avascular necrosis. The mandibular-maxillary fixations were removed after 4 weeks and patients were could open 3.5 cm after 6 weeks with physical therapy. Conclusion: We tried closed manual reduction of mandibular condylar fracture due to high risk of complication using C-arm fluoroscopy and did achieve anatomic reduction with avoiding open incision. This is simple, effective, reversible, time saving and fairly attemptable method in condylar fracture cases before open reduction.

The Avalibility of C-Arm in Reduction of Zygomatic Arch Fracture Intraoperatively: Case Report (관골궁 골절의 정복시 수술 중 C-Arm 사용의 유용성: 증례보고)

  • Seo, Mi-Hyun;Cheon, Kang-Yong;Yun, Jun-Yong;Yoo, Chung-Kyu;Lee, Eun-Kyung;Lee, Won-Deok;Suh, Je-Duck
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.359-362
    • /
    • 2010
  • The zygoma is second most commonly vulnerable facial bone in fracture, in number only by nasal fractures. It is difficult to evaluate reduction state intraoperatively, because almost surgeons reduce the fractured zygoma by blind method. We suggest the use of orthopedic C-arm intraoperatively. We use plain radiography, CT to evaluate preoperative state. Gilles approach or intraoral approach were used to reduce the fractured zygomatic arch. The C-arm was positioned at chin area, used to evaluate reduction intraoperatively. We got postoperative image by CT or submento-vertex view. There are variable methods to evaluate reduction intraoperatively: palpation, ultrasonography, CT, plain films. C-arm is considered superior diagnostic tool to other methods. The use of intraoperative C-arm was very efficient, it could bring better results.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Design and Implementation of ARM based Network SoC Processor (ARM 기반의 네트워크용 SoC(System-on-a-chip) 프로세서의 설계 및 구현)

  • 박경철;박영원
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.440-445
    • /
    • 2004
  • The design and implementation of a Network Processor using System-on-a-chip(SoC) technology is presented. The proposed network processor can handle several protocols as well as various types of traffics simultaneously. The proposed SoC consists of ARM processor core, ATM block, AAL processing block, Ethernet block and a scheduler. The scheduler guarantees QoS of the voice traffic and supports multiple AAL2 packet. The SoC is manufactured on the 0.35 micron fabrication line of HYNIX semiconductor, the total number of gates is about 312,000, for a maximum operating frequency of over to 50㎒.

A Study on the Thermal Analysis for the Robotic Arm of the Cord Blood Storage Tank (제대혈 용기 내부 로봇 암의 열해석에 관한 연구)

  • Yun, Sang-Kook;You, Sam-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.724-729
    • /
    • 2008
  • Umbilical cord blood has been recently considered an attractive potential alternative as a source of stem cell transplantation to curing diseases such as leukemia, cancers, immune disorders. Normally the stored system of the umbilical cord blood specimen is equipped with a computer-controlled robotic arm that enables the samples to locate the identification places in liquid nitrogen tank at regulated temperature as about $-196^{\circ}C$. As the half of robotic arm is in the air and the rest part is submerged in liquid nitrogen, the temperature of robotic arm varies from ambient to liquid nitrogen temperature. In this study the temperature variation of upper part of arm above tank lid was thermally analysed by using the commercial code of Ansys. The result of analysis was that the upper part of robotic arm was seriously frozen due to heat transfer from liquid nitrogen as low as -$120^{\circ}C$. In order to solve the frost problem of robotic arm, small PTFE tube block as resistance material was introduced into the lower part of tank lid instead of the whole stainless steel(SUS) robotic arm. The results showed that the temperature of robotic arm above the lid was higher enough, and this method would be one of the very effective measure to solve the problem.

Implementation of Segment_LCD display based on SoC design

  • Ling, Ma;Kim, Kab-Il;Son, Young-I.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.59-62
    • /
    • 2003
  • The purpose of this paper is to present how to implement Segment_LCD display using SoC design. The SoC design is achieved by using an ARM_based Excalibur device. The Excalibur device offers an outstanding embedded development platform with ARM922T and FPA. The design in the Excailbur device uses the embedded AR띤 Processor core and the AMBA high-performance bus (AHH) to write to a memory-mapped slave peripheral in the FPGA portion of the device. Here, Segment_LCD is one kind of memory-mapped slave peripherals. In order to Implement the Segment_LCD display based on SoC design, four steps are fellowed. At first, IP modules are made by using Verilog HDL. Secondly, the ARM processor of the Excalibur is programmed using C in ADS (ARM Developer Suite). And in the third step, the whole system is simulated and verified. At last, modules are downloaded to SoCMaster kit. Both Quartus II software and ModelSim5.5e software are the key software tools during the design.

  • PDF