• Title/Summary/Keyword: C-SCAN

Search Result 784, Processing Time 0.029 seconds

Clinical implications of DMSA Scan in Childhood Acute Pyelonephritis

  • Huh, Sun-Mi;Park, Bo-Kyoung;Kang, Hyun-Mi;Rhim, Jung-Woo;Suh, Jin-Soon;Lee, Kyung-Yil
    • Childhood Kidney Diseases
    • /
    • v.21 no.2
    • /
    • pp.107-113
    • /
    • 2017
  • Purpose: This study aimed to evaluate the relationships between 99mTecnicium-dimercaptosuccinic acid (DMSA) scan findings and clinical parameters including age and fever duration. Methods: The positive rates for abnormal DMSA scans were analyzed according to the age of patients, fever duration prior to admission, and total fever duration. DMSA scan findings were divided into 3 categories: single defect, multifocal defects, and discrepant defects. We evaluated the detection rates of vesicoureteral reflux according to DMSA scan lesions. Results: Among a total 320 cases, 141 (44.1%) had abnormal DMSA scans. The infant group (0-1 year of age) had a shorter total fever duration, and a lower C-reactive protein (CRP) value and DMSA positive rate (39.8% vs. 60.6%, P=0.002) compared to children group (2-15 years of age). Patients with abnormal scans had a longer total fever duration and higher CRP compared to those with normal scans. The positivity rate of abnormal scans did not differ between the patients with a short fever duration prior to admission of ${\leq}2$ days and those with longer fever duration of ${\geq}3$ days. However, patients with longer total fever duration had a higher rate of abnormal DMSA scans (P=0.02). Among cases with a single defect, multifocal defects, and discrepant defects, vesicoureteral reflux was observed in 22.4%, 60% and 70.6% of cases, respectively (P=0.004). Conclusion: Although DMSA scan has limitations in early diagnosis, DMSA scan findings may aid in the prediction of the severity of systemic inflammation and detection of vesicoureteral reflux.

Thyroiditis: Radioisotope Scan Findings and Clinical Significance (갑상선염의 방사선동위원소 검사소견 및 임상적의의)

  • Kim, Jong-Chae;Han, Duck-Sup;Park, Jung-Suck;Kim, Se-Jong;Park, Byung-Lan;Kim, Byoung-Geun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.280-285
    • /
    • 1991
  • We analyzed Radioisotope scan findings of 46 patients of thyroiditis which were proven pathologically at K.C.H. The results were as follows 1) 45 patients were female, one was male and average age of patients was 37 years old. 2) The lesion site was predominant in both lobe (67%) 3) Hashimoto's thyroiditis showed enlarged thyroid (85%) with cold nodule (20%), diffuse decreased activity (10%), while subacute thyroiditis was presented absent activity (53%), poor visualization (20%) or cold nodule (7%) 4) Radioisotope scan was valuable in evaluations function of thyroid gland and detection of lesion but there was a limit of pathological nature.

  • PDF

Development of Thermal Imaging Observation System (관측용 열상장비의 개발)

  • Hong, S.M.;Song, I.S.;Kim, C.W.;Kim, H.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.9-11
    • /
    • 1993
  • This paper decribed the development of Thermal Imaging Oservation System(TIOS) using the serial-parallel scan method. The detectors scan five lines at a time. These are put into serial order by electronic scan converter. Digital memory and high speed multiplexer are used for the serial conversion instead of charge coupled devices. As a result, thermal imaging system be presented with exellent performance which MRTD value is less than $0.5^{\circ}K$ at 7.5 cycles/mm.

  • PDF

Developement of Ultrasonic Handy Scanner for Welding Inspection (초음파를 이용한 용접부 핸디 스캔 검사기 개발)

  • Kang, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.14-18
    • /
    • 2005
  • The ultrasonic handy scanner to be developed in this research is a nondestructive inspection equipment with various facility. The ultrasonic inspection is the technique area which apply range is increasing greatly with IT. The purpose of this research is development of a ultrasonic handy scan inspection device with the utility in a work spot. The ultrasonic handy scanner to be developed with portability in this research is able to carry out the spot inspection. It can contribute to the quality improvement, cost reduction and safety design.

Development of Thermal Imaging Observation System (관측용 열상장비의 개발)

  • Hong, S.M.;Song, I.S.;Kim, C.W.;Kim, H.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.543-545
    • /
    • 1993
  • This paper decribed the development of Thermal Imaging Oservation System(TIOS) using the serial-parallel scan method. The detectors scan five lines at a tine. These are put into serial order by electronic scan converter. Digital memory and high speed multiplexer are used for the serial conversion instead of charge coupled devices. As a result, thermal imaging system be presented with exellent performance which MRTD value is less than $0.5^{\circ}K$ at 7.5 cycles/mm.

  • PDF

A Study on Laser Scan Path Generation for Improving the Precision of Stereolithographic Parts (광조형물의 정밀도 향상을 위한 Laser주사경로 생성에 관한 연구)

  • Park, H.T.;Lee, S.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.12
    • /
    • pp.142-150
    • /
    • 1996
  • Nowadays, as the development paeiod of new products becomes even shorter, the importance of Rapid Prototyping Technology(RPT) has been rapidly increased. The major application of RPT is an early verification of product designs and quick production of prototypes for testing. Moreover, RPT is applied not only as a second tooling process such as mold making and investment casting but also as a creating some physical structure in medical field. Despite the remarkable progress of RPT, it is required to improve various problems resulting from application such as production time, accuracy and materials. This paper presents a laser scan path generation for accuracy of stereolithographicparts The methodology of laser scan path generation is discussed based on the stereolithography, The procedure of this research is as follows : 1) Input laser scanning conditions such as a laser beam diameter and a laser scanning interval, 2) Reconstruct original contours without self intersecting offset, 3) Calculate offset about reconstructed contours, 4) Calculate intersection points between horizontal or vertical lines and offset contours for internal hatch, 5) Decide laser shutter on/off points. The algorithm developed and programmed by C language is verified as an efficient method after testing a number of STL files of mechanical parts.

  • PDF

Clinical Characteristics in Patients with Biliary Obstruction Diagnosed by $^{99m}Tc-DISIDA$ Scan -In 9 Cases with Normal Ultrasonographic Findings- ($^{99m}Tc-DISIDA$ 간담도 스캔상 담도폐쇄로 진단된 환자의 임상적 특성 -초음파 검사상 정상 소견을 보인 9예를 중심으로-)

  • Park, Bong-Chul;Yang, Soo-Hyun;Che, Dong-Ho;Park, Sung-Ki;Byun, Jong-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.82-85
    • /
    • 1992
  • To evaluate the role of hepatobiliary (DISIDA) scan in the diagnosis of biliary obstruction, we studied the clinical characteristics of 9 cases with biliary obstructuon, whose hepatobiliary scans and ultrasonography were not concordant (normal ultrasonography and abnormal hepatobiliary scan). The results were as follows; 1) The main chief complaints (89%) were abdominal pain, especially in RUQ area. The levels of serum bilirubin were elevated in 67% of patients $(normal\sim5.9mg/dl)$ and those of alkaline phosphatase were elevated in 78% of patients $(normal\sim724U/L)$. 2) The final diagnoses were CBD stones (67%), tumor (22%) and 3 cases were associated with C. sinensis. 3) The major obstruction sites were in distal CBD (89%). From the above results we concluded that hepatobiliary scan is a useful diagnostic method of biliary obstruction, especially in distal CBD lesion and early stage, in spite of normal ultrasonography.

  • PDF

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

Cluster of Parasite Infections by the Spatial Scan Analysis in Korea

  • Bae, Kyoung-Eun;Chang, Yoon Kyung;Kim, Tong-Soo;Hong, Sung-Jong;Ahn, Hye-Jin;Nam, Ho-Woo;Kim, Dongjae
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.6
    • /
    • pp.603-608
    • /
    • 2020
  • This study was performed to find out the clusters with high parasite infection risk to discuss the geographical pattern. Clusters were detected using SatScan software, which is a statistical spatial scan program using Kulldorff's scan statistic. Information on the parasitic infection cases in Korea 2011-2019 were collected from the Korea Centers for Disease Control and Prevention. Clusters of Ascaris lumbricoides infection were detected in Jeollabuk-do, and T. trichiura in Ulsan, Busan, and Gyeongsangnam-do. C. sinensis clusters were detected in Ulsan, Daegu, Busan, Gyeongsangnamdo, and Gyeongsangbuk-do. Clusters of intestinal trematodes were detected in Ulsan, Busan, and Gyeongsangnam-do. P. westermani cluster was found in Jeollabuk-do. E. vermicularis clusters were distributed in Gangwon-do, Jeju-do, Daegu, Daejeon, and Gwangju. This clustering information can be referred for surveillance and control on the parasitic infection outbreak in the infection-prone areas.

두 경부 종양의 C-T 영상을 이용한 방사선 치료계획시 Artifact가 선량 계산에 미치는 영향

  • 김경태;주상규
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.109-112
    • /
    • 2001
  • 1. 목적 : head and neck cancer 환자의, C-T 영상을 이용한 방사선치료계획시 치과 보철물에 의해 발생하는 artifact가 선량 계산에 미치는 영향을 분석하고자 한다. 2. 재료 및 방법:두 경부와 유사한 크기의 Polystyrenes Phantom ($20{\times}20{\times}25cm^3$) 을 제작하고, 팬톰내에 금으로 인공보철물을 제작하여 보철물 부착 전.후를 C-T Scan (High Speed Advantage, GE, US) 하였다. artifact에 의한 영향을 쉽게 분석하기위해 팬톰내에 다른 구조물은 만들지 않았으며 두가지 방법으로 얻어진 영상을 이용하여 조사면의 크기와 조사 방향을 변화 시켜 가며 1문 조사(SSD 100 cm)에 의한 치료 계획(3D RTP system, Prowess, US)을 수립하여 기준점(5,10 cm depth)에서의 선량 변화를 비교 분석하였다. 아울러 3회 반복 scan하여 artifact에 발생 유형과 CTNo을 이용한 density을 분석하였다. 3. 결과: C-T Scan으로 얻어진 image 상에 나타난 Artifact는 CT no $-1000{\sim}+2775$(기준 $-1000{\sim}+3700$)까지의 다양한 값을 가지며 보철물을 기준으로 방사형태로 분포하였다. artifact가 선량 계산에 미치는 영향을 분석한 결과 보철물 사용시 5cm깊이의 기준점에서 절대선량은 평균 $+1.5{\pm}2.8\%$, 10 cm 깊이에서는 $+1.8{\pm}3.5\%$의 오차를 보였다. 조사방향에 의한 오차는 artifact에 대해 측면 조사한(gantry $270^{\circ}$)경우에서 높게 관찰되었다. 4. 결론: 두 경부 종양의 방사선 치료시 치과 보철물에 의한 artifact는 흔히 관찰가능하며 본 실험을 통해 다양한 형태와 다양한 density을 가짐을 알수있었다. 영상에 나타난 정도에 비해 선량계산에 미치는 평균 오차는 낮게 평가되었지만 조사 방향과 보철물의 위치에 따라 변동이 크게 나타날 수 있어 치료 계획시 가능한 artifact의 영향을 적게 받는 빔의 선택이 정확한 선량 계산에 도움을 줄 것으로 사료된다.

  • PDF