• Title/Summary/Keyword: C-Arm

Search Result 701, Processing Time 0.024 seconds

Postoperative Systemic Dissemination of Injected Elemental Mercury

  • Kang, Suk-Hyung;Park, Seung-Won;Moon, Kyung-Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.245-247
    • /
    • 2011
  • There were only a few reports of mercury on pulmonary artery. However, there is no data on surgery related mercury dissemination. The objective of the present article is to describe one case of postoperative injected mercury dissemination. A 19-year-old man presented severe neck pain including meningeal irritation sign and abdominal pain after injection of mercury for the purpose of suicide. Radiologic study showed injected mercury in the neck involving high cervical epidural space and subcutaneous layer of abdomen. Partial hemilaminectomy and open mercury evacuation of spinal canal was performed. For the removal of abdominal subcutaneous mercury, C-arm guided needle aspiration was done. After surgery, radiologic study showed disseminated mercury in the lung, heart, skull base and low spinal canal. Neck pain and abdominal pain were improved after surgery. During 1 month after surgery, there was no symptom of mercury intoxication except increased mercury concentration of urine, blood and hair. We assumed the bone work during surgery might have caused mercury dissemination. Therefore, we recommend minimal invasive surgical technique for removal of injected mercury. If open exposures are needed, cautious surgical technique to prohibit mercury dissemination is necessary and normal barrier should be protected to prevent the migration of mercury.

Optimal Double Heat Treatment Process to Improve the Mechanical Properties of Lightweight AlSiCu Alloy (자동차 경량소재 AlSiCu 합금의 기계적 특성을 개선하기 위한 최적의 이중 열처리공정)

  • Park, Sang-Gyu;Kim, Chung-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.102-108
    • /
    • 2018
  • The objective of this study is to develop the mechanical properties of an AlSiCu aluminum alloy using the two-step solution heat treatment. The microstructure of the gravity casting specimen represents a typical dendrite structure with a secondary dendrite arm spacing (SDAS) of 40 um. In addition to the Al matrix, a large amount of coarsen eutectic Si phase, $Al_2Cu$ intermetallic phase, and Fe-rich phases is generated. The eutectic Si phases are fragmented and globularized with the solution heat treatment. The $Al_2Cu$ intermetallic phase is also resolutionized into the Al matrix. The $2^{nd}$ solution temperature at $525^{\circ}C$ may be an optimal condition to enhance the mechanical properties of the AlSiCu aluminum alloy.

Design and fabrication of microgripper using thermal actuator and SU-8 (열 구동 엑츄에이터와 SU-8을 이용한 마이크로 그리퍼 설계 및 제조)

  • Jung, Seoung-Ho;Park, Joon-Shik;Lee, Min-Ho;Park, Sang-Il;Lee, In-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1613-1616
    • /
    • 2007
  • A microgripper using thermal actuator and SU-8 polymer was designed and fabricated to manipulate cells and microparts. A chip size of a microgripper was 3 mm ${\times}$ 5 mm. The thermally actuated microgripper consisted of two couples of hot and cold arm actuators. The high thermal expansion coefficient, 52 $ppm/^{\circ}C$, of SU-8 compared to silicon and metals, allows the actuation of the microgripper. Thickness and width of SU-8 as an end-effector were 26 ${\mu}m$ and 80 ${\mu}m$, respectively. Initial gap between left jaw and right jaw was 120 ${\mu}m$. The ANSYS program as FEM tool was introduced to analyze the thermal distribution and displacement induced by thermal actuators. $XeF_2$ gas was used for isotropic silicon dry etching process to release SU-8 end-effector. Mechanical displacements of the fabricated microgripper were measured by optical microscopy in the range of input voltage from 0 V to 2.5 V. The maximum displacement between two jaws of a microgripper Type OG 1_1 was 22.4 ${\mu}m$ at 2.5 V.

  • PDF

Skin Temperature Responses of Hanbok When It Worn (한복 착용에 따른 피보온의 변화)

  • 송명견;신정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.6
    • /
    • pp.763-770
    • /
    • 2002
  • The objective of the study was to investigate skin temperature responses of Hanbok when it was worn. Two healthy females(average 21 years, 155cm and 60kg were exposed to a climatic chamber(Room Temp. $21{\pm}1^{\circ}C,\;52{\pm}2%R.H.$, 0.15m/s). During the experiment, rectal temperature, skin temperature of 9 areas, clothing microclimate, subjective sensation were measured. Chima and Jogory to be made of silk nobang(SN) or Ramie were worn for summer. Polyester(P) Chima and Jogori(R) could be wort for spring and autumn. For winter, silk Chima, Jogori(S) and Durumagi(D) were commonly worn. Rectal temperature was high in order of naked(N), R, SN, P, S, D. However Mean skin temperature was reversely high in order of D, S, SN, R, P, naked. In naked, skin temperature was high in order of head, trunk upper extremity and lower extremity. But on wearing of Hanbok, it was the highest at the chest except head regardless of kinds of clothing ensembles. Skin temperature of upper arm was secondly highest on wearing the silk ensemble and the Durumagi ensemble, but skin temperature of buttock was secondly highest on wearing the silk nobang ensemble and the ramie ensemble. Skin temperature on wearing the silk ensemble was generally higher than those on other clothing ensembles. Local and mean skin temperatures on wearing the silk ensemble and the Durumagj ensemble were generally higher than on other clothing ensembles. Heat resistance of the fabric might have affected on the local skin temperature.

A Study on the Development of Blouse Patterns for Obese Women in Their 20s and 30s (20~30대 비만 여성을 위한 블라우스 패턴 개발)

  • Jie, Fei;Nam, Young-Ran;Kim, Dong-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.3
    • /
    • pp.464-484
    • /
    • 2020
  • This study examined obese women with a BMI index over than 25 kg/㎡ in their 20s and 30s regarding the right fit for wearing a blouse. In comparison with three types of existing educational patterns, the first educational pattern experimental clothing was produced in dimensions of three study participants selected by the existing pattern to evaluate the fit suitability conducted for groups of study participants and expert groups. Experimental patterns were designed based on educational pattern C, which was the best fit as a result of the fitting evaluation. The main modification items include front bust circumference, hip circumference, back interscye, scye depth, shoulder length, blouse length, bottom line shape, upper arm circumference, wrist circumference, sleeve length and collar size. The design preferences for obese women were reflected in pattern modification; in addition, the final experimental pattern was designed by adding or subtracting margins and dimensions based on the results of the visual matching assessment by study subjects and expert groups.

Development of a Mower Attachable Hydraulic Boom for Tractor (트랙터용 유압붐 부착형 모워 개발에 관한 연구)

  • Jang I.J.;Kim T.S.;Son J.R.;Bae C.Y.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.4 s.117
    • /
    • pp.334-341
    • /
    • 2006
  • This study designed to develop a mower which can reach to side of a tractor or inclined road side and operate weeding. The prototype consists of 4 parts; the base and turning equipment, the boom, the arm, the weeder. The hydraulic actuators were divided into two operations, weeding and operation of boom and they were controlled by electrical equipment. Weeding was very effective when pressure set up at $15{\ell}/min$ using weeding, as $2.27kg{\cdot}m$, 2,210rpm. Weeding range of flail mower was 1.1 to 2.6m from the center of turning equipment at a flat. In case of disk mower, it was 1.5 to 2m. As a result of operation test, flail mower was appropriate for weeding at fence and short weeds, disk mower was appropriate for long weeds.

Radiation Exposure to Physicians During Interventional Pain Procedures

  • Kim, Tae-Wan;Jung, Jang-Hwan;Jeon, Hyun-Joo;Yoon, Kyung-Bong;Yoon, Duck-Mi
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • Background: Fluoroscopy has been an integral part of modern interventional pain management. Yet fluoroscopy can be associated with risks for the patients and clinicians unless it is managed with appropriate understanding, skill and vigilance. Therefore, this study was designed to determine the amount of radiation received by a primary operator and an assistant during interventional pain procedures that involve the use of fluoroscopy. Methods: In order to examine the amount of radiation, the physicians were monitored by having them wear three thermoluminescent badges during each single procedure, with one under a lead apron, one under the apron collar and one on the leg during each single procedure. The data obtained from each thermoluminescent badge was reviewed from September 2008 to November 2008 and the annual radiation exposure was subsequently calculated. Results: A total of 505 interventional procedures were performed with C-arm fluoroscopy during three months. The results of this study revealed that the annual radiation exposure was relatively low for both the operator and assistant. Conclusions: With proper precautions, the use of fluoroscopy during interventional pain procedures is a safe practice.

Comparison of Morphine and Tramadol in Transforaminal Epidural Injections for Lumbar Radicular Pain

  • Park, Chan Hong
    • The Korean Journal of Pain
    • /
    • v.26 no.3
    • /
    • pp.265-269
    • /
    • 2013
  • Background: Transforaminal epidural steroid injections are known to reduce inflammation by inhibiting synthesis of various proinflammatory mediators and have been used increasingly. The anti-inflammatory properties of opioids are not as fully understood but apparently involve antagonism sensory neuron excitability and pro-inflammatory neuropeptide release. To date, no studies have addressed the efficacy of transforaminal epidural morphine in patients with radicular pain, and none have directly compared morphine with a tramadol for this indication. The aim of this study was to compare morphine and tramadol analgesia when administered via epidural injection to patients with lumbar radicular pain. Methods: A total of 59 patients were randomly allocated to 1 of 2 treatment groups and followed for 3 months after procedure. Each patient was subjected to C-arm guided transforaminal epidural injection (TFEI) of an affected nerve root. As assigned, patients received either morphine sulfate (2.5 mg/2.5 ml) or tramadol (25 mg/0.5 ml) in combination with 0.2% ropivacaine (1 ml). Using numeric rating scale was subsequently rates at 2 weeks and 3 months following injection for comparison with baseline. Results: Both groups had significantly lower mean pain scores at 2 weeks and at 3 months after treatment, but outcomes did not differ significantly between groups. Conclusions: TFEI of an opioid plus local anesthetic proved effective in treating radicular pain. Although morphine surpassed tramadol in pain relief scores, the difference was not statistically significant.

Aminoglycoside susceptibility and genetic characterization of Salmonella enterica subsp. enterica isolated from pet turtles

  • Hossain, Sabrina;De Silva, B.C.J.;Wimalasena, S.H.M.P.;Pathirana, H.N.K.S.;Heo, Gang-Joon
    • Korean Journal of Veterinary Service
    • /
    • v.40 no.1
    • /
    • pp.27-33
    • /
    • 2017
  • Salmonella enterica subsp. enterica is a common microbial flora in pet turtles, which could opportunistically become pathogenic to human. Their possession of aminoglycoside resistance genes has important significance both in humans and animal medicine. In this study, twenty-one Salmonella enterica subsp. enterica were isolated from thirty-five individual turtles purchased from pet shops and online markets in Korea. In order to characterize the aminoglycoside susceptibility patterns, antimicrobial susceptibility tests were performed against gentamicin, amikacin and kanamycin of aminoglycoside antimicrobial group. Each of the isolates showed susceptibility to all tested aminoglycosides in disk diffusion and minimum inhibitory concentration (MIC) tests. PCR assay was carried out to determine aminoglycoside resistance genes, integron and integron mediated aminoglycoside genes. None of the isolates showed aac(3)-IIa, aac-(6')-Ib, armA, aphAI-IAB aminoglycoside resistance genes. Only, five isolates (24%) harbored class 1 integron related IntI1 integrase gene. The results suggest that Salmonella enterica subsp. enterica strains isolated from pet turtles are less resistance to aminoglycosides and don't harbor any aminoglycosides resistance genes.

A GNSS Signal Correlation Using Map-based Partial-time Common Intermediate Frequency Removal Method (맵 기반의 부분시간 공통 중간주파수 제거방식을 이용한 GNSS 신호의 상관 기법)

  • Im, Sung-Hyuck;Jee, Gyu-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.695-701
    • /
    • 2008
  • In this paper, we propose the efficient Doppler removal method using map-based partial-time common intermediate frequency removal technique. In the proposed algorithm, the 2-stage carrier removal process was used. First, the component of common intermediate frequency is removed. Next the component of Doppler was removed with averaging and approximation. For the evaluation of the proposed algorithm, The real-time software GPS L1 C/A-code receiver was implemented. When the proposed algorithms are used, 12 tracking channels with 3 track arm(early, prompt, late) is operated real-time on PC using a Intel Pentium-III 1.0GHz CPU. Also, the requirement of memory was less than 2Mbytes. The real-time software GNSS receiver using the proposed algorithms provides the navigation solution with below 10 meter rms error. Especially, in spited of using the various approximations for implementing the algorithms, the high sensitivity capability (able to track the weak signal with -159dBm) was achieved.