• Title/Summary/Keyword: C-형 근관

Search Result 22, Processing Time 0.034 seconds

A cone-beam computed tomographic study of C-shaped root and root canal in maxillary molars (콘빔CT (Cone beam computed tomography, CBCT)를 이용한 상악 대구치 에서의 C-형 치근 및 근관에 관한 연구)

  • Kim, Jin-Woo;Ji, Hyo-Jin;Cho, Kyung-Mo;Kim, Sung-Min;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.104-111
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the prevalence rate and types of C-shaped roots and C-shaped canal in maxillary molars by analyzing cone-beam computed tomography (CBCT) in a Korean population. Materials and Methods: Total of 357 CBCT images of maxillary molars (186 first molar, 171 second molar) were evaluated by two Endodontic specialists. Results: Eight types of C-shaped roots and 5 types of C-shaped canals were founded, the prevalence rate of C-shaped roots and canals were 21.0% and 5.3% respectively. Conclusion: These anatomical variations were more frequent in second molars than the first molars. Clinicians should have anatomical knowledge about various types of C-shaped root and root canal for successful root canal therapy.

A retrospective study of the intentionally replanted mandibular second molars with C-shaped root canal configurations (C-형 근관계를 가진 하악 제2대구치의 의도적 재식술 결과에 대한 후향적 연구)

  • Shon, Won-Jun;Kum, Kee-Yeon;Baek, Seung-Ho;Lee, Woo-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • Objectives: The purpose of this retrospective study was to evaluate the success rate of intentionally replanted mandibular second molar with C-shaped canal configurations and to access the impact of preoperative periapical lesion on the success of intentional replantation procedure. Materials and Methods: This retrospective chart review study evaluated 52 intentionally replanted mandibular second molar teeth treated at Seoul National University Dental Hospital Department of Conservative Dentistry from January 2005 to December 2007. Seventeen teeth were lost for the follow-up, and another 6 teeth did not meet inclusion criteria of C-shaped root canal configurations. Healing outcome such as success, uncertain healing, and failure after follow-up was evaluated by clinical criteria and radiographs. Results: The overall success rate was 72.4% for the 29 intentionally replanted C-shaped mandibular second molars. The success rate of replanted teeth with preoperative periapical lesions was similar to that of replanted teeth which have no periapical lesions. Conclusions: Therefore, root canal treatment failure on C-shaped mandibular second molar can be predictably treated by intentional replantation regardless of the presence of periapical lesion.

CROSS-SECTIONAL MORPHOLOGY AND MINIMUM CANAL WALL WIDTHS IN C-SHAPED ROOT OF MANDIBULAR MOLARS (C-shaped canal의 절단면 분석을 통한 근관형태의 변화와 근관과 치아외벽간의 최소거리 분석에 관한 연구)

  • Song, Byung-Chul;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 2007
  • The C-shaped canal system is an anatomical variation mostly seen in mandibular second molars, although it can also occur in maxillary and other mandibular molars. The main anatomical feature of C-shaped canals is the presence of fins or web connecting the individual root canals. The complexity of C-shaped canals prevents these canals from being cleaned, shaped, and obturated effectively during root canal therapy, and sometimes it leads to an iatrogenic perforation from the extravagant preparation. The purpose of this study was to provide further knowledge of the anatomical configuration and the minimal thickness of dentinal wall according to the level of the root. Thirty extracted mandibular second molars with fused roots and longitudinal grooves on lingual or buccal surface of the root were collected from a native Korean population. The photo images and radiographs from buccal, lingual, apical direction were taken. After access cavity was prepared, teeth were placed in 5.25% sodium hypochlorite solution for 2 hours to dissolve the organic tissue of the root surface and from the root canal system. After bench dried and all the teeth were embedded in a self-curing resin. Each block was sectioned using a microtome (Accutom-50, Struers, Denmark) at interval of 1 mm. The sectioned surface photograph was taken using a digital camera (Coolpix 995, Nikon, Japan) connected to the microscope. 197 images were evaluated for canal configurations and the minimal thickness of dentinal wall between canal and external wall using 'Root Thickness Gauge Program' designed with Visual Basic. The results were as follows : 1. At the orifice level of all teeth, the most frequent observed configuration was Melton's Type C I (73%), however the patterns were changed to type C II and C III when the sections were observed at the apical third. On the other hand, the type C III was observed at the orifice level of only 2 teeth but this type could be seen at apical region of the rest of the teeth. 2. The C-shaped canal showed continuous and semi-colon shape at the orifice level, but at the apical portion of the canal there was high possibility of having 2 or 3 canals 3. Lingual wall was thinner than buccal wall at coronal, middle, apical thirds of root but there was no statistical differences.

A comparison of chlorhexidine release rate from three polymeric controlled release drug prototypes (제어방출형 소독제의 약물전달 체로 사용된 폴리머 유형에 따른 클로르헥시딘 제어 방출속도 비교)

  • Bok Young-Bin;Lee Doug-Youn;Lee Chang-Young;Kim Kyung-Nam;Kum Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.548-552
    • /
    • 2004
  • Intracanal disinfection of infected root canal is one of important treatment procedure. This in vitro study aimed to evaluate whether the surface polymers of controlled release drug (CRD) can effectively control the release rate of chlorhexidine for root canal disinfection. Four CRD prototypes were prepared: Group A (n=12); The core device (absorbent paper point) was loaded with 40% CHX solution as control. Group B (n=12); same as group A, but the device was coated with chitosan. Group C (n=12); same as group A and then coated three times with 5% PMMA. Group D (n=12); same as group A and then coated three times with 3% PLGA. All CRD prototypes were soaked in 3 mL distilled water for experimental periods and the concentrations of released CHX from each CRD prototype were determined using a UV spectrophotometer. Results showed that release rate of CHX were the greatest in the non-coated group (control group), followed by the chitosan-coated group, the PLGA-coated group, and the PMMA-coated group (P < 0.05). This data indicate that surface polymers can control the release rate of CHX from the CRD prototypes.

Comparative study on the apical sealing ability according to the obturation techniques (근관충전방법에 따른 치근단부 폐쇄능에 대한 비교연구)

  • Hwang, Ho-Keel;Park, Sun-Hee;Lee, Yeon-Jae
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.290-298
    • /
    • 2002
  • 3차원적으로 잘 충전된 근관은 치근단 누출과 재감염을 방지하며, 조직이 잘 치유될 수 있는 생물학적 환경을 제공해준다. 이 때문에 근관계의 완전한 충전은 근관치료의 중요한 목표 중의 하나이다. 본 연구의 목적은 4가지 방법으로 근관충전 후 디지털 방사선 사진을 촬영하여 근관충전의 질을 평가하고 투명표본을 제작하여 색소침투범위를 측정함으로써, 근관충전방법에 따른 치근단부 폐쇄능을 비교 평가하고자 하는 것이다. 직선형의 단근관을 갖는 80개의 전치를 선택하여 ProFile$^{\circledR}$ 니켈-티타늄 회전식 기구를 사용하여 근관을 성형한 후 무작위로 20개씩 4군으로 나누었다. 사용된 근관충전법은 다음과 같다:MicroSeal$^{\circledR}$(Group A), Thermafil$^{\circledR}$(Group B), Continuous wave 충전법(Group C), 측방가압충전법(Group D), 각 군에서 10개 치아는 Sealapex를, 나머지 10개 치아는 AH26$^{\circledR}$을 충전용 시멘트로 사용하였다. 근관충전이 끝난 치아는 충전의 질과 길이를 평가하기 위해, 근원심과 협설방향으로 디지털 방사선 사진을 이용하여 촬영하였다. 각 치아의 치근단부 2mm를 제외한 나머지 부위는 두겹의 nail varnish를 바르고, 2% methlylene blue용액에 48시간동안 침잠시켰다. 흐르는 물에 깨끗이 세척한 후, 투명치아를 만들었다. 선상의 색소침투를 관찰하고 치관측 최대깊이를 입체현미경하에서 40배율로 평가하여 다음과 같은 결과를 얻었다. 1. 충전방법에 따른 근단부 폐쇄효과를 비교시, 실험군 모두 비교적 양호한 근단부 폐쇄효과를 보였고 통계학적으로 유의성이 없었다. 2. 충전용 시멘트에 따른 근단부 폐쇄효과를 비교시, AH26$^{\circledR}$을 사용한 군에서 Sealapex를 사용한 군보다 더 적은 색소침 투를 나타냈다(p<0.05). MicroSeal$^{\circledR}$을 이용한 실험 1군내에서 AH26$^{\circledR}$을 사용하였을 때 미세누출이 더 적었고(p<0.05), 다른 군내에서는 통계학적으로 유의성이 없었다. 3. 근단부 충전상태에 따른 미세누출 비교시, 저충전, 과충전과 색소침투간에는 상관관계가 없었다. 4.충전방법에 따른 근단부 충전상태 평가시, Thermafil$^{\circledR}$을 이용한 실험 2군에서 과충전이 많이 나타났다(p<0.05). 이상의 결과로, 기존의 측방가압법 및 여러 열가소성 충전법이 유사한 근단부 폐쇄효과를 나타낸 바, 방법에 따른 술자의 숙련도, 충전시간, 재근관치료의 편이성 등을 고려하여 근관충전방법을 선택하는 것이 합리적일 것이라고 사료된다.

EFFECTS OF CONDENSATION TECHNIQUES AND CANAL SIZES ON THE MICROLEAKAGE OF ORTHOGRADE MTA APICAL PLUG IN SIMULATED CANALS (모조 근관의 크기와 충전 방법이 orthograde MTA apical plug의 미세누출에 미치는 영향)

  • Nam, Deuk-Lim;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.208-214
    • /
    • 2009
  • The purpose of this study was to compare the dye leakage of MTA (mineral trioxide aggregate) apical plug produced by two orthograde placement techniques (hand condensation technique and ultrasonically assisted hand condensation technique). To simulate straight canal, 60 transparent acrylic blocks with straight canal were fabricated. These transparent acrylic blocks were divided into 2 groups (Group C; hand condensation technique (HC) and Group U; ultrasonically assisted hand condensation technique (UAHC)) of 30 blocks with each MTA application method. Each group was divided into 2 subgroups (n=15) with different canal size of #70 (subgroup C70 and subgroup U70) and #120 (subgroup C120 and subgroup U120). After apical plug was created, a wet paper point was placed over the MTA plug and specimen was kept in a humid condition at room temperature to allow MTA to set. After 24 hours, remaining canal space was backfilled using Obtura II. All specimens were transferred to floral form socked by 0.2% rhodamine B solution and stored in 100% humidity at room temperature. After 48 hours, resin block specimens were washed and scanned using a scanner. The maximum length of micro leakage was measured from the scanned images of four surfaces of each resin block using Photoshop 6.0. Statistical analysis was performed with Mann-Whitney U test. Group U of UAHC had significantly lower leakage than Group C of HC in #70-size canal (subgroup U70) (p<0.05).

The Influence of AH-26 and Zinc Oxide-Eugenol Root Canal Sealer on the Shear Bond Strength of Composite Resin to Dentin (AH-26 및 산화아연유지놀 근관실러가 상아질에 대한 복합레진의 전단결합강도에 미치는 영향)

  • Cho, Ju-Yeon;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.147-152
    • /
    • 2006
  • The purpose of this study was to evaluate the influence of the AH-26 root canal sealer on the shear bond strength of composite resin to dentin. One hundred and forty four (144) extracted, sound human molars were used. After embedding in a cylindrical mold, the occlusal part of the anatomical crown was cut away and trimmed in order to create a flat dentin surface. The teeth were randomly divided into three groups; the AH-26 sealer was applied to the AH-26 group, and zinc-oxide eugenol (ZOE) paste was applied to the ZOE group. The dentin surface of the control group did not receive any sealer. A mount jig was placed against the surface of the teeth and the One-step dentin bonding agent was applied after acid etching. Charisma composite resin was packed into the mold and light cured. After polymerization, the alignment tube and mold were removed and the specimens were placed in distilled water at $37^{\circ}C$ for twenty four hours. The shear bond strength was measured by an Instron testing machine. The data for each group were subjected to one-way ANOVA and Tukey's studentized rank test so as to make comparisons between the groups. The AH-26 group and the control group showed significantly higher shear bond strength than the ZOE group (p<0.05). There were no significant differences between the AH-26 group and the control one (p>0.05). Under the conditions of this study, the AH-26 root canal sealer did not seem to affect the shear bond strength of the composite resin to dentin while the ZOE sealer did. Therefore, there may be no decrease in bond strength when the composite resin core is built up immediately after a canal filling with AH-26 as a root canal sealer.

The EFFECTS OF VARIOUS INSTRUMENTATION TECHNIQUES IN CURVED CANALS OF RESIN BLOCKS (만곡근관에서 수동식 기구와 엔진 구동형 기구의 근관성형 효과에 대한 비교 연구)

  • Jung, Il-Young;Yoon, Tai-Cheol;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.648-658
    • /
    • 1997
  • The purpose of this study was to compare the effects of various techniques on the quality and quantity of instrumentation in curved canals. Instrumentation time was evaluated too. Forty eight canals of resin blocks($35^{\circ}$) were divided into three groups and filed. In group A, 16 blocks were instrumented using a step-back technique with stainless steel(SS) K-file(Mani, Matsutani Seisakusho Co.,Japan). In group B, canals were prepared with SS K-files using the Endo-Angle (Nakanishi Dental MFG.CO.,LTD.,Japan). Group C was prepared using N i-Ti engine-driven instruments (Quantec Series $2000^{TM}$ system). Group A and B were filed from # 5 to # 25 at the apex followed by a 1 mm stepback technique, and the coronal half of the canals were flared with Gates Glidden burs(#2,3,4). Group C was instrumented from # 1 to # 8. After the instrumentation time was measured, canals were filled with India ink, and photographed, which to magnify the canal images 8 times. Using these photographs the apical portions were evaluated And scored from 1 to 4 according to the severity of ledging and zipping. On the same photographs, the area of the coronal two thirds of the canals were measured using a personal computer with the computer program Brain and Digitizer (SummaSketch III). The following results were obtained. 1. Instrumentation time was significantly shorter for group C, as opposed to group A and B(ANOVA, P<0.05). 2. The qualitative evaluation of the apical portions of the canals showed no significant difference between the groups(Kruscal-Wallis, p>0.05). 3. The area removed by group C was significantly smaller than group A and B(ANOVA, P<0.05).

  • PDF

Job Analysis of the Nurses Who Work in Customized Visiting Health Care Services using DACUM Technique (맞춤형 방문건강관리사업 내 방문간호사의 직무분석)

  • Nam, Hye Kyung;Cho, Kyung Sook
    • Journal of muscle and joint health
    • /
    • v.22 no.3
    • /
    • pp.205-218
    • /
    • 2015
  • Purpose: This study was performed to analyze the visiting nurses' job using Developing a curriculum (DACUM). Methods: The DACUM committee with 6 visiting nurses participated in the workshop. In this workshop, the visiting nurses role was defined and their duties and tasks were identified. After content validation via the experts, the pilot test was conducted to 78 nurses. Results: A total of 13 duties and 82 tasks were identified on the DACUM chart which represented the importance, difficulty, and frequency of tasks with alphabet A, B, and C as its higher degree. Regarding duties, 'visiting nursing for high risk group' is the highest, while the lowest was 'public welfare events'. Regarding to tasks, 'discovering a new patient' was the highest, while 'selecting patients and offering medical supplies (nutritional supplement, patch)' was the lowest one. Conclusion: The results showed that visiting nurses working in the visiting health care service center were doing more various duties and tasks than those working according to 'Act on Long-term Care Insurance for the Aged'. The results can be used to develop training programs for visiting nurses and evaluation-scale of their job performance.

Preliminary evaluation of a tapered cylindrical shock wave source (테이퍼 형상을 가지는 원통형 충격파 발생기의 특성 평가)

  • Choi M. J.;Cho S. C.;Kang K. S.;Paeng D. G.;Lee J. S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.379-384
    • /
    • 2004
  • 체외 충격파 쇄석술 (ESWL)은 체외에서 발생된 충격파를 체내의 결석이 위치한 부위에 집속하여 결석을 분쇄하는 비 침습적인 치료술이다. 최근 충격파를 이용하여 근관절 질환을 치료하는 체외 충격 파 치료술 (ESWT)이 또한 임상적으로 주목을 받고 있다. 아직 ESWT를 위한 최적의 충격파 노출 조건은 알려져 있지 않지만, 일반적으로 ESWL에 비해 상대적으로 충격파장의 초점 영역이 넓고 낮은 강도의 충격파를 사용한다. 본 연구에서는 ESWT에 적합할 것으로 예상되는 테이퍼 원통형 충격파 발생 방식을 제안하고자 한다. 본 연구에서는 테이퍼 원통형 충격 파 발생 의 초점 부위의 파형을 수치 해석하여 평가하고, 기존 원통형의 경우와 비교하였다. 테이퍼 원통형 충격파 발생기의 시제품을 제작하고, 발생된 강도를 평가하기 위해, 모의 결석을 제작하여 분쇄 효율을 측정하였으며, 결과를 원통형 충격파 발생기와 비교하였다.

  • PDF