• Title/Summary/Keyword: C/R

Search Result 18,309, Processing Time 0.039 seconds

Effects of Natufermen® Supplementation to the Diet on the Perfermance of Weanling Pigs (사료내 Natufermen® 첨가가 이유 자돈의 생산성에 미치는 영향)

  • Lim, H.S.;Kim, B.H.;Paik, I.K.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.981-988
    • /
    • 2004
  • An Experiment was conducted to investigate the effects of Natufermen$^{(R)}$;(Aspergillus oryzae) supplementation on the performance, ammonia gas production, microbial population in manure and serum IgG in pigs. Forty eight cross bred(YLD) weanling pigs(35d old) were assigned to 4 treatments; Control(C), $C^+$ Natufermen 0.1%, $C^+$ Natufermen 0.2% $C^+$natufermen 0.3% for 6 week feeding trial. Each treatment had 4 replications of 3 pigs each. Natufermen$^{(R)}$ supplemented treatments tended to increase ADG and ADFI, but there were no significant differences among treatments. Supplementation of Natufermen$^{(R)}$ at the level of 0.2% improved ADFI/ADG(P<0.05). Ammonia gas production from manure was not significantly affected by treatments. All Natufermen$^{(R)}$ treatments increased in DM, crude ash and phosphorus digestibility(P<0.05). Serum IgG decreased as supplemention level of Natufermen$^{(R)}$ increased(P<0.05). Supplemtation of Natufermen$^{(R)}$ at 0.1% and 0.2% increased fecal Lactobacilli population at 3 wks after feeding treated diets(P<0.05). It is concluded that supplementation of Aspergillers oryzae product Natufermen$^{(R)}$ improved feed conversion ratio and digestibility of DM, crud ash and phosphours. Fecal ammonia gas production was not significantly affected but serum IgG level was decreased and CFU of fecal Lactobacilli was increased at 3 wks after feeding Natufermen$^{(R)}$ supplemented diets.

Flow Condensation Heat Transfer of R22, R134a, R407C, and R410A in Plain and Microfin Tubes (평관과 마이크로 핀관 내 R22, R134a, R407C, R410A의 흐름응축 열전달성능)

  • 조영목;박기호;송길흥;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.656-663
    • /
    • 2002
  • Flow condensation heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured on horizontal plain and microfin tubes. The experimental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water/glycol loop. The test section in the refrigerant loop was made of both a plain and a microfin copper tube of 9.52 mm outside diameter and 1.0 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of $40^{\circ}C$ with mass fluxes of 100, 200, and 300 kg/$m^2s$. Test results showed that at similar mass flux the flow condensation HTCs of R134a were similar to those of R22 for both plain and microfin tubes. On the other hand, HTCs of R407C were lower than those of R22 by 11~l5% and 23~53% for plain and microfin tubes respectively. And HTCs of R410A were similar to those of R22 for a plain tube but lower than those of R22 by 10~21% for a microfin tube. In general, HTCs of a microfin tube were 2.0~3.0 times higher than those of a plain tube.

In vitro Selection of RNA Aptamers which Bind to Escherichia coli tRNAVal (대장균 tRNAVal에 결합하는 RNA Aptamer들의 시험관내 선별)

  • Jo, Bong Rae
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.2
    • /
    • pp.157-163
    • /
    • 2002
  • To identify RNA motifs interacting with $tRNA^{Val}$, a SELEX(Systematic Evolution of Ligands by Exponential Enrichment) was applied. Random DNA library which contains a region of ran-domized 48-mer oligonucleotide flanked by conserved sequ ence primers was transcribed into RNA pool using T7 RNA polymerase and RNA aptamers were selected with $tRNA^{Val}$ -immobilized affinity column through 14 rounds of SELEX. Some of the resulting aptamers contained a consensus sequence similar to the sequence in the loop regions of three rRNAs; C43GAAC47 sequence of 5S rRNA, G1491AAGU1495, G1379UUCC1383 sequence of 16S rRNA and C1064UUAG1068, G2110UGUA2114, C2480GACGG2485, A2600CAGU2604 sequence of 23S rRNA. These results suggest that $tRNA^{Val}$ can interact with 5S rRNA, 16S rRNA and 23S rRNA with variety in ribosome.

Direct Synthesis and Structure of $\eta^4$-1-Functionally Substituted 2,3,4,5-Tetraphenyl-1-Silacyclopenta-2,4-diene Complexes of Irontricarbonyl

  • Joo, Qan-Chul;Sohn, Hong-Lae;Hong, Jang-Hwan;Kong, Young-Kun;Singh, P.
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.2
    • /
    • pp.191-196
    • /
    • 1989
  • We obtained the new complexes, $Fe{\eta}^4-R,R'-TPSCp](CO)_3$(R,R'-TPSCp = 1,1-disubstituted 2,3,4,5-Tetraphenyl-1-Silacyclopenta-2,4-diene; R = Ph, R' = Cl, R = R' = Cl) from the reaction of the corresponding R,R'-TPSCp with ironpentacarbonyl under reflux in toluene. Also, the analogous complexes with R = R' = Me and R = Me, R' = Cl were obtained in an identical manner. We have determined the crystal structure of $Fe[Ph(Cl)-TPSCp](CO_)3$ by using Mo ka, ${\lambda}$ = 0.71069${\AA}$, where the unit cell was found to be monoclinic with a = 9.042 (6)${\AA}$, b = 19.870 (9)${\AA}$, c = 17.426 (9)${\AA}$ and ${\beta}$ = 96.28(4)$^{\circ}$. The butadiene moiety of TPSCp ring is planar and the dihedral angle of the butadiene plane and C4-Si-C25 plane was opened up to 41.8$^{\circ}$. The C-C distances in the butadiene moiety were found to be 1.4346, 1.462, and 1.440 ${\AA}$, respectively. It may be said that the four ${\pi}$-electrons are delocalized over the four carbons in five membered ring through coordination with ironcarbonyl. In this complex Fe is either in distorted tetrahedron environment with the centroid of the four C-atom butadiene moiety and three carbons of the three carbonyls or in distorted square-pyramidal environment with two midpoints of double bonds of the butadiene moiety and two carbons of carbonyl defining the base of the pyramid and the carbon of remaining carbonyl the apex.

Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump (R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석)

  • Kang, Byun;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

GENERALIZED DERIVATIONS WITH CENTRALIZING CONDITIONS IN PRIME RINGS

  • Das, Priyadwip;Dhara, Basudeb;Kar, Sukhendu
    • Communications of the Korean Mathematical Society
    • /
    • v.34 no.1
    • /
    • pp.83-93
    • /
    • 2019
  • Let R be a noncommutative prime ring of characteristic different from 2, U the Utumi quotient ring of R, C the extended centroid of R and f($x_1,{\ldots},x_n$) a noncentral multilinear polynomial over C in n noncommuting variables. Denote by f(R) the set of all the evaluations of f($x_1,{\ldots},x_n$) on R. If d is a nonzero derivation of R and G a nonzero generalized derivation of R such that $$d(G(u)u){\in}Z(R)$$ for all $u{\in}f(R)$, then $f(x_1,{\ldots},x_n)^2$ is central-valued on R and there exists $b{\in}U$ such that G(x) = bx for all $x{\in}R$ with $d(b){\in}C$. As an application of this result, we investigate the commutator $[F(u)u,G(v)v]{\in}Z(R)$ for all $u,v{\in}f(R)$, where F and G are two nonzero generalized derivations of R.

Experimental study on the performance of R-502 alternative refrigerant mixtures (R-502 대체 혼합냉매의 성능에 관한 실험적 연구)

  • Park, D.M.;Jeoung, D.S.;Kim, J.B.;Kang, D.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.198-209
    • /
    • 1997
  • This paper is concerned about the performance of alternative refrigerants of R-502 which has been widely used in transport and low temperature refrigeration. A breadboard heat pump was constructed with counterflow heat exchangers and tested with R-502 and transitional alternatives of R-402A and R-402B and long-term alternatives of R-404A and R-507 to compare the performance of each refrigerant. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$ and $52.0^{\circ}C$ and the evaporating temperature was varied over a range from $-25^{\circ}C$ to $-5^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about $5^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this research work can be used as 'drop-in' fluids to replace R-502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

Performance Characteristics of a Cascade Refrigeration System with Internal Heat Exchanger using Carbon Dioxide (R744) and Propane (R290) (내부 열교환기 부착 $CO_2-C_3H_8$용 캐스케이드 냉동시스템의 성능 특성)

  • Son, Chang-Hyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.6
    • /
    • pp.526-533
    • /
    • 2009
  • In this paper, cycle performance analysis of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system with internal heat exchanger is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree and gas cooling pressure and evaporating temperature in the propane (R290) low temperature cycle and the carbon dioxide (R744) high temperature cycle. The main results were summarized as follows : The COP of cascade refrigeration system of $CO_2-C_3H_8$ (R744-R290) increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of cascade refrigeration system increases with the increasing evaporating temperature, but decreases with the increasing gas cooling pressure. Therefore, superheating and subcooling degree, compressor efficiency, evaporating temperature and gas cooling pressure of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system have an effect on the COP of this system.

Ni/Si/Ni Ohmic contacts to n-type 4H-SiC (Ni/Si/Ni n형 4H-SiC의 오옴성 접합)

  • Lee, J.H.;Yang, S.J.;Noh, I.H.;Kim, C.K.;Cho, N.I.;Jung, K.H.;Kim, E.D.;Kim, N.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.197-200
    • /
    • 2001
  • In this letter, we report on the investigation of Ni/Si/Ni Ohmic contacts to n-type 4H-SiC. Ohmic contacts have been formed by a vacuum annealing and $N_2$ gas ambient annealing method at $950^{\circ}C$ for 10 min. The specific contact resistivity ( $\rho_{c}$ ), sheet resistance($R_s$), contact resistance($R_c$), transfer length($L_T$) were calculated from resistance($R_T$) versus contact spacing(d) measurements obtained from 10 TLM(transmission line method) structures. The resulting average values of vacuum annealing sample were $\rho_{c}=3.8{\times}10^{-5}\Omega cm^{3}$, $R_{c}=4.9{\Omega}$, $R_{T}=9.8{\Omega}$ and $L_{T}=15.5{\mu}m$, resulting average values of another sample were $\rho_{c}=2.29{\times}10^{-4}\Omega cm^{3}$, $R_{c}=12.9{\Omega}$ and $R_{T}=25.8{\Omega}$. The physical properties of contacts were examined using X-Ray Diffraction and Auger analysis, there was a uniform intermixing of the Si and Ni, migration of Ni into the SiC.

  • PDF