• 제목/요약/키워드: C/A code

Search Result 1,640, Processing Time 0.033 seconds

A Road Luminance Measurement Application based on Android (안드로이드 기반의 도로 밝기 측정 어플리케이션 구현)

  • Choi, Young-Hwan;Kim, Hongrae;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.49-55
    • /
    • 2015
  • According to the statistics of traffic accidents over recent 5 years, traffic accidents during the night times happened more than the day times. There are various causes to occur traffic accidents and the one of the major causes is inappropriate or missing street lights that make driver's sight confused and causes the traffic accidents. In this paper, with smartphones, we designed and implemented a lane luminance measurement application which stores the information of driver's location, driving, and lane luminance into database in real time to figure out the inappropriate street light facilities and the area that does not have any street lights. This application is implemented under Native C/C++ environment using android NDK and it improves the operation speed than code written in Java or other languages. To measure the luminance of road, the input image with RGB color space is converted to image with YCbCr color space and Y value returns the luminance of road. The application detects the road lane and calculates the road lane luminance into the database sever. Also this application receives the road video image using smart phone's camera and improves the computational cost by allocating the ROI(Region of interest) of input images. The ROI of image is converted to Grayscale image and then applied the canny edge detector to extract the outline of lanes. After that, we applied hough line transform method to achieve the candidated lane group. The both sides of lane is selected by lane detection algorithm that utilizes the gradient of candidated lanes. When the both lanes of road are detected, we set up a triangle area with a height 20 pixels down from intersection of lanes and the luminance of road is estimated from this triangle area. Y value is calculated from the extracted each R, G, B value of pixels in the triangle. The average Y value of pixels is ranged between from 0 to 100 value to inform a luminance of road and each pixel values are represented with color between black and green. We store car location using smartphone's GPS sensor into the database server after analyzing the road lane video image with luminance of road about 60 meters ahead by wireless communication every 10 minutes. We expect that those collected road luminance information can warn drivers about safe driving or effectively improve the renovation plans of road luminance management.

A Study on the Medium Designator In Non-book Materials (비도서자료의 매체표시에 관한 연구)

  • Nam Tae Woo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.15
    • /
    • pp.119-140
    • /
    • 1988
  • This paper is the study on the Medium Designator in Non-book materials. Main contents of this study were as follows; 1. The medium designator serves to indicate the class of material to which an item belongs. This is used to give an 'early warning' ;to the catalogue user. 2. This medium designator may be further divided into two elements ; a general material designation (GMD), for example video-recording, and a specific material designation (SMD), for example, videodisc. 3. GMD: In cataloging, a term indicating the broad class of material to which a bibliographic item belongs, such as 'motion picture', and SMD : In descriptive cataloging, a term indicating the special class of material (usually the class of physical object) to which a biblographic item belongs, such as videocassette. 4. Locating the medium designator after the title proper was not prescribed until ISBD(G) and AACR2. In pre-ISBD(G) codes, the ,early, warning type of medium designator was placed after all title information. But in AACR2, the medium designator is placed after the title proper, but before parellel title and other title information. 5. In Terminology, Two separate lists of designations are given in AACR2, l.1C1, one for British and one for North American use. The British list contains fewer terms, and uses generic categories to group together some of the North American list. 6. The problem of where to place the medium designator might be circumvented by using some kind of early alerting device other than a formal element of biblliographic description. Various alternatives have been suggested. A more popular device is the provision of symbols or 'media code' which are part of the call number and indicate the porticular medium type. 'Colour-coding' the use of used by some libraries but is now longly discouraged. 7. According to Frost. The medium designatorhas been generally reeognized as serving three functions; 1) as a statement of the nature or basic format of the item cataloged and thus as a meant of informing the user as to the type of material at hand; 2) as a description of the physical charaetistics of medium and as a means of alerting the user to equipment needed to make use of the item. 3) as a device to distinguish different physical formats which share the same title. 8. AACR2 raises some problems which decision makers have neet had to face preriously It provides a GMD for every item in the collection including books and it makes the application of any or all GMD's optional.

  • PDF

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design - (수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로-)

  • 박문갑;윤갑동;김석제;윤종락
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2001
  • The underwater background noise measured in Geoje and Tongyoung diving fishing ground from May to December, 2000 and analyzed to get optimum carrier frequency and transmitter power level for underwater wireless telephone design. The results obtained are summarized as follows: 1. At the Geoje and Tongyoung diving fishing ground, the lowest ambient noise band was 25~30kHz with 57dB and 52dB re 1$\mu$Pa, respectively. 2. At the Geoje and Tongyoung diving fishing ground, the lowest noise band during fishing activity was 67dB and 62dB re 1$\mu$Pa, respectively. 3. At the Geoje diving fishing ground, the noise of water jetter which is a digging machine for subbottom shells was 102dB re 1$\mu$Pa. 4. Considering the design parameters of underwater wireless telephone, it is found that the optimum carrier frequency band is around 30kHz and the transmitter source level should be at least 131dB re 1$\mu$Pa for 500m range telephone.

  • PDF

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

The Development of Post-Processing GPS(L1)/Galileo(E1/E5a) Software Receiving Platform using MATLAB (GPS(L1)/Galileo(E1/E5a) 다중 신호 통합 수신 소프트웨어 플랫폼 개발)

  • Jeon, Sang-Hoon;So, Hyoung-Min;Lee, Taek-Jin;Kim, Ghang-Ho;Jeon, Seung-Il;Kim, Jong-Won;Kee, Chang-Don;Cho, Young-Su;Choi, Wan-Sik;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.311-318
    • /
    • 2009
  • This paper shows the research about the development of software receiving platform processing GPS/Galileo L1/E1/E5a signal. Various researches for new GNSS signal character are possible using software receiving platform by facile program code modification. In addition, the program that processes GPS and Galileo signal integration is expected to help developing integration of receiver algorithm that deal with new various GNSS signal. In this paper, it is introduced the structure of GPS/Galileo receiving platform using sampled IF data as a program input. The function of the software platform embodied using MATLAB tool is tested by live data from Galileo test satellites. The software platform is modulated according to their roll and function. Each module is able to use selective function on GNSS signal.

  • PDF

A case study on the effect of communication training program on nurse's communication ability, emotional intelligence (EQ), self - esteem and interpersonal ability (의사소통 훈련 프로그램이 간호사의 의사소통능력, 감성지능(EQ), 자존감 및 대인관계능력에 미치는 효과에 대한 사례연구)

  • Yoo, Mi-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.280-290
    • /
    • 2018
  • This study was a non-equivalence-based Quasi experimental study comparing the difference in communication ability, emotional intelligence (EQ), self-esteem, and interpersonal abilities between an experimental group with communication training and a non-control group. The subjects of the study were nurses working for D university hospital located in C city and comprised an experimental group of 21 people and a control group of 21 people. From April to May 2017, the experimental group took communication training programs, which were designed to improve communication capacity, emotional intelligence, self-esteem, and interpersonal ability for a total of four sessions (for 2 hours a week), and pre-post examination was conducted for the validity of the study. For data analysis, the SPSS for Windows 23 was used for the mean and standard deviation of pre-post tests, and U-test of the independent sample Mann-Whitney and the Wilcoxon code order test of the corresponding sample were carried out. The study results indicate that, compared with the control group, the experimental group showed communication capacity (Z=-3.361, p<.05), emotional intelligence (Z=-2.209, p<.05), self-esteem (Z=-1.633, p<.05), and interpersonal relationship (Z=-2.577, p<.05). After the communication training program, scores of communication capacity, emotional intelligence (EQ), self-esteem, and interpersonal competence of the experimental group increased significantly, and all hypotheses were supported. These results suggest that nurses' use of communication training experience in performing nursing work in a clinical setting would improve communication skills, emotional intelligence (EQ), self-esteem, and interpersonal skills and provide therapeutic communication and effective nursing, thereby enhancing patients' satisfaction and contributing to the improvement of nursing quality.

Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb (오픈소스 기반 수술항법장치의 하지 골절수술 응용검토)

  • Joung, Sanghyun;Park, Jaeyeong;Park, Chul-Woo;Oh, Chang-Wug;Park, Il Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.497-503
    • /
    • 2014
  • Minimally invasive intramedullary nail insertion or plate osteosynthesis has shown good results for the treatment of long bone fractures. However, directly seeing the fracture site is impossible; surgeons can only confirm bone fragments through a fluoroscopic imaging system. The narrow field of view of the equipment causes malalignment of the fracture reduction, and radiation exposure to medical staff is inevitable. This paper suggests two methods to solve these problems: surgical navigation using 3D models reconstructed from computed tomography (CT) images to show the real positions of bone fragments and estimating the rotational angle of proximal bone fragments from 2D fluoroscopic images. The suggested methods were implemented using open-source code or software and evaluated using a model bone. The registration error was about 2 mm with surgical navigation, and the rotation estimation software could discern differences of $2.5^{\circ}$ within a range of $15^{\circ}$ through a comparison with the image of a normal bone.

The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source (기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발)

  • Huh, Hyun-Do;Kim, Woo-Chul;Loh, John-Jk;Lee, Suk;Lee, Sang-Hoon;Cho, Sam-Ju;Shin, Dong-Oh;Choi, Jin-Ho;Kwon, Soo-Il;Kim, Seong-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.232-237
    • /
    • 2006
  • The aim of this study was to develop the calculation algorithm of source strength of Ir-192 source In terms of the absorbed dose to water instead of an apparent activity (Ci). For this work the Multi Purpose Brachytherapy Phantom(MPBP) was developed, which was designed to locate the source and the chamber precisely at a specific position Inside the water phantom. The reference point of measurement was set at the 5 cm distance along the transverse axis of the source. For a brachytherapy source calibration, the absorbed dose to water calibration factor ($N_{D.W.Q}$) of an lonization chamber were determined and then apply standard protocols of absorbed dose to water. The calibration factor ($N_{D.W.Q}$) of the ion chamber (TM30013, PTW, Germany) was determined using the EGSnrcCPP Monte Carlo Code. The calculated calibration factor ($N_{D.W.Q}$) was 5.28 cGy/nC. The calculated factor was then used to determine the absorbed dose to water from which the air kerma strength for an Ir-192 source can be easily derived at the reference point (5 cm). The calculated air kerma strength showed discrepancies of -0.6% to +1.8% relative to the air kerma strength provided by the vendor, In this work we demonstrated that the air kerma strength ($S_k$) could be determined from the absorbed dose to water calibration factor for Ir-192 source. In audition, this source calibration method could be applied directly to the dose Calculation formalism of AAPM report TG-43.

  • PDF