• 제목/요약/키워드: Bypass piping

검색결과 13건 처리시간 0.062초

가동원전 잔열제거계통 배관에서의 열성층유동 해석 (An Analysis on Thermal Stratification in Residual Heat Removal System Piping of Nuclear Power Plant)

  • 박만홍;김광추;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1597-1602
    • /
    • 2003
  • Numerical analysis is carried out to assess the temperature distribution on the mixing tee line of Residual Heat Removal System (RHRS). In RHRS, hot and cold fluids of main and bypass piping are mixed and unmixed by the flow rate or piping layout. Thermal stratification phenomenon is a cause of major degradation on RHRS piping. According to the analysis for each operation modes, maximum temperature difference between top and bottom of piping were evaluated about 60K when the flow rate of main and bypass lines is same. Temperature difference will be decreased at the elbow on RHRS piping if the length of vertical piping is increased.

  • PDF

RTD Bypass Line Elimination at Kori Nuclear Power Plant 3&4

  • Yoon, Duk-Joo;Lee, Chang-Sup;Jun, Hwang-Yong;Lee, Jae-Yong;Song, Dong-Soo
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.213-218
    • /
    • 1997
  • The RTD Bypass Loops at Kori Unit 3&4 will be removed and a new system will be designed and will be installed to replace it. The replacement system provides equal or better performance and eliminates some Persistent problems. The Resistance Temperature Detector (RTD) bypass line is eliminated to reduce the radiation exposure to operators and workers. After the elimination, the resistance temperature detectors are installed in scoop of the reactor coolant piping to detect a representative temperature. This study includes safety evaluation, RTD response time Analysis, Uncertainty Analysis, LOCA evaluation and Structural Analysis.

  • PDF

하나로 유동 모의 설비의 유체순환계통 해석 (The Analysis for Flow Circulation System in HANARO Flow Simulation Facility)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.30-35
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. HANARO flow simulation facility is being developed for the endurance test of reactivity control units for extended life time and the verification of structural integrity of those experimental equipments prior to loading in the HANARO. This facility is composed of three major parts; a half-core structure assembly, a flow circulation system and a support system. The flow circulation system is composed of a circulation pump, a core flow piping, a core bypass flow piping and instruments. The system is to be filled with de-mineralized water and the flow should be met the design requirements to simulate a similar flow characteristics in the core channel of the half-core structure assembly to the HANARO. This paper, therefore, presents an analytical analysis to study the flow behavior of the system. Computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with the standard $k-{\epsilon}$ turbulence model and for the verification of the structural piping integrity through the finite element method. According to the analysis results, it could be said that the design requirements and the structural piping integrity of the flow circulation system are satisfied.

화력발전소 주증기배관에서 밸브 차단에 따른 수증기 충격 특성에 관한 연구 (A Study on the Steam Hammering Characteristics by Sudden Closure of Main Stop Valve in the Main Steam Piping System of a Power Plant)

  • 하지수;이부윤
    • 한국가스학회지
    • /
    • 제17권2호
    • /
    • pp.70-77
    • /
    • 2013
  • 본 연구는 화력발전소 최종과열기에서 고압터빈 사이 배관과 고압터빈을 지난 곳에 있는 체크밸브와 1차 재열기 사이 배관을 포함한 수증기 배관시스템에서 터빈의 급작스런 사고로 인해 터빈으로 들어가는 수증기를 차단할 때 발생하는 수증기 충격이 배관시스템에 미치는 영향을 분석하는 연구이다. 이를 위해서 수격현상 해석에 많이 사용하는 Flowmaster 소프트웨어로 배관시스템을 모델링하고 시간 변화에 따라 배관 내부의 압력, 질량유량률의 특성을 파악하였다. 이러한 특성으로부터 수증기 충격이 주로 영향을 미치는 곡관에서 수증기 충격에 의한 힘을 도출하였다. 본 연구를 통해서 수증기 충격은 주증기 차단 밸브 직전의 곡관과 체크밸브 이후에 바이패스 배관과 연결되는 곡관에서 수증기 충격에 의한 힘이 가장 크게 나타남을 밝혀냈다. 본 연구에서는 이렇게 도출한 힘의 기본 자료를 이용하여 차후 연구에서 화력발전소 수증기 배관시스템의 수증기 충격 시 곡관과 지지대의 안전성을 진단하는 토대를 구축하였다.

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

측정 데이터 기반 중수로 압력관 직경평가 방법론 개발 (Diameter Evaluation for PHWR Pressure Tube Based on the Measured Data)

  • 정종엽
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.27-35
    • /
    • 2023
  • Pressure tubes are the main components of PHWR core and serve as the pressure boundary of the primary heat transport system. However, because pressure tubes have changed their geometrical dimensions under the severe operating conditions of high temperature, high pressure and neutron irradiation according to the increase of operation time, all dimensional changes should be predicted to ensure that dimensions remain within the allowable design ranges during the operation. Among the deformations, the diameter expansion due to creep leads to the increase of bypass flow which may not contribute to the fuel cooling, the decrease of critical channel power and finally the deration of the power to maintain the operational safety margin. This study is focused on the modeling of the expansion of the pressure tube diameter based on the operating conditions and measured diameter data. The pressure tube diameter expansion was modeled using the neutron flux and temperature distributions of each fuel channel and each fuel bundle as well as the measured diameter data. Although the basic concept of the current modeling approach is simple, the diameter prediction results using the developed methodology showed very good agreement with the real data, compared to the existing methodology.

바이패스용 3-Way 밸브를 장착한 온수 난방시스템의 압력 및 유량 특성 평가 (Performance Test of Pressure and Flow Rate in a Hot-Water Heating System with 3-Way Valves for Flow Bypass)

  • 허전;이석종;성재용;이명호;윤재동
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.269-274
    • /
    • 2007
  • A 3-way valve has been applied to a distributor in a hot-water heating system and the performance of the system was evaluated in view of the variations of pressure drop and flow rate. The 3-way valve has been designed to bypass overplus hot-water when a control valve is closed. Note that the flow goes through heating pipeline in normal operation. In the present study, the measured pressure drops in each part of the flow paths show that the contribution to the total pressure drop is in the order of the supply header with control valves, piping system of each room and return header of the distributor, even though the amount of it is different according to the flow paths. As a result of performance test by sequential closing of the control valves, the variations of pressure drop and flow rate in the distributor with 3-way valves is much lower than those with previous 2-way valves, which prevent noises induced by pressure fluctuations.

원액흡입배관 단면적 확장에 의한 포 소화설비 혼합비 개선에 관한 실험적 연구 (An Experimental Study on the Improvement of Foam Fire-Extinguishing System's Mixing Ratios by Expanding the Cross Sectional Area of the Stock Solution Inhaling Piping)

  • 윤기조;장경남;백은선;박봉래;박희중
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.30-37
    • /
    • 2013
  • 본 연구는 가연성탱크 화재발생시 하나의 포 비례혼합기에서 분기헤더를 거쳐 다수의 소화지역 분기방식 포 소화설비의 분기헤더에서 저장탱크 하단부 입상관 까지의 포수용액 배관단면적 감소에 따른 통과유량 감소로 혼합비가 허용범위를 벗어날 때 적정농도의 포수용액 방출에 효과적인 방법을 확보하는데 궁극적인 목적이 있다. 이를 위해 기설치 포 소화설비의 유량변동에 따른 혼합비 변동원인 분석 및 일정혼합비 보상방법을 찾아보고, 포 비례혼합기 벤츄리 폼챔버 오리피스 및 미터링 오리피스 교체실험을 통해 원액흡입배관 단면적을 확장시킬 수 있는 미터링 오리피스 교체실험이 포 소화설비 혼합비 개선에 가장 효과적인 방안임을 입증하였다.

공동주택 기계실 난방설비 운전 개선 연구 (A Study on Improved Operation of Apartment Heating System in a Machine Room)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.