• Title/Summary/Keyword: Bypass function

Search Result 152, Processing Time 0.03 seconds

Axillofemoral Bypass to Treat Severe Heart Failure Caused by Takayasu's Arteritis

  • Bang, Ji-Hyun;Kim, Jong-Wook;Jung, Sung-Ho;Lim, Ju-Yong
    • Journal of Chest Surgery
    • /
    • v.45 no.2
    • /
    • pp.124-126
    • /
    • 2012
  • Takayasu's arteritis is an inflammatory vasculitis that primarily affects the aorta and its major branches. Involvement of the thoracic and abdominal aortas, although rare, causes marked hypertension and may lead to severe heart failure. We report the improvement of cardiac function after axillofemoral bypass grafting in a 59-year-old woman who had this condition.

Introduction on the by-pass road construction for Siem Reap, Cambodia (캄보디아 시엠립 우회도로건설 사업 소개)

  • Roh, Han-Sung;Kim, Hyo-Bae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.614-625
    • /
    • 2008
  • The project of Construction of Siem Reap bypass road in Cambodia consists of alignment improvement of existing route, extension of width of road and laterite paving. This project is carried out by fast-track method on the design and construction for bypass road of 15.2 km length and 8m width for five months. Though some difficulties for the construction works such as the location of borrow pit and rock source, rainy seasons etc, the construction could be completed successfully owing to the cooperation of related authorities, company and residents. This 2 way Angkor detouring road will function as industrial roads in Siemreap region. These new two roads will not only bring better logistics requirements and safety, but also impact to poverty alleviation and preservation the beauty of the ecological environment of Angkor region. The basic information related to geotechnical engineering of this project is introduced.

  • PDF

Coronary Artery Bypass Grafting in an Infant after an Arterial Switch Operation

  • Choi, Wooseok;Pyo, Wonkyung;Choi, Eun Seok;Chung, Cheol Hyun
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.146-149
    • /
    • 2021
  • Coronary artery bypass grafting (CABG) is rarely performed in infants because of its technical difficulty and unclear long-term results. A 90-day-old male infant weighing 3.5 kg who underwent an arterial switch operation (ASO) for transposition of the great arteries developed left coronary artery insufficiency despite augmentation and reimplantation of the left coronary button. On-pump beating heart CABG was performed using an internal mammary artery graft to revascularize the left anterior descending artery. Postoperative computed tomography angiography revealed that the graft was patent. At 7 months postoperatively, the patient weighed 8.5 kg, and echocardiography revealed good ventricular function. CABG can be an alternative treatment for post-ASO coronary complications in early infancy.

The nonlinear fuzzy intelligent theory for high-bypass-ratio two-spool unmixed-flow jet engines

  • C.C. Hung;T. Nguyen
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.4
    • /
    • pp.369-391
    • /
    • 2023
  • In our research we have offered a solid solution for aeronautical analysis. which can guarantee the asymptotic stability of coupled nonlinear facilities. According to the theoretical solutions and methods presented, the engine of this aircraft is a small high-bypass turbofan engine. using the non-linear aero-motor control approach and this paper focuses on the power management function of the aero-motor control system. These include static controls and transient controls. A mathematical model of the high-bypass-ratio two-spool unmixed-flow aeroengine was developed through a set of nonlinear dynamic equations verified by experimental data. A single actuator using the displacement method is designed to maintain a certain level of thrust under steady-state conditions. and maintains repeatable performance during transient operation from the requested thrust phase to the next. A single controller can compensate for the effects of noise and harmonic noise at many performance points. And the dynamic performance of a single controller is satisfactory during the transient. for fairness Numerical and computer experiments are described in the perfection of the methods we offer in research.

Improved Model for Maximum Power Point Tracking (MPPT) of Solar System (태양광 시스템의 최대 전력지점 추적(MPPT) 정확도 향상을 위한 모델링)

  • Lee, YoungHyun;Lee, Jonghwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.114-118
    • /
    • 2022
  • The photovoltaic system is affected by various conditions such as temperature and irradiance. Because non-uniform irradiation and partial shading conditions affect the entire string of cells connected in series, a bypass diode is used to bypass the current flow normally. In order to find the maximum power point in partial shade conditions, it is necessary to estimate various methods of maximum power point tracking. In this paper, the hybrid method of MPPT using Lambert W function and perturbation & observation algorithm is proposed under partial shading conditions. The simulation results are obtained using MATLAB/Simulink and shows the improvement of the accuracy of MPPT.

Performance of Fault-tolerant Ethernet System with Link-bypass scheme for Airbone Databus (항공 데이터버스용 링크 우회방식을 가진 고장감내 이더넷 시스템의 성능 분석)

  • Song, Dae-Yoen;Yoon, Chong-Ho;Jung, Han-Gyun;Kim, Seung-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.9
    • /
    • pp.46-53
    • /
    • 2007
  • The link-fault recovery in the normal Ethernet bridged networks has relied on the Spanning Tree Protocol(STP) or Rapid STP. However, STP can not offer fast error recovery which is needed real-time services such as aircraft. In this paper, we compare automatic protection switching(APS) providing fault-tolerant function in the BcN back bone system with Avionic Full Duplex Switched Ethernet(AFDX) which is recently equipped in the A380 for Airbone Databuses. Also, we propose a link-bypass scheme for improving fault-tolerant performance of the AFDX by connecting switches and bypass fault section when a fault is originated on the link. For comparing and verifying the performance of proposed scheme, we simulated Ethernet, AFDX, APS and proposed AFDX with link-bypass scheme using NS-2. The proposed AFDX with link-bypass scheme can be applied to aircrafts, BcN backbone networks and industrial automatic networks.

Establishment of Featal Heart Surgery with an Improvement of the Placental Blood Flow in Cardiopulmonary Bypass Using Fetal Lamb Model (양태아를 이용한 심폐우회술에서의 태반혈류개선을 통한 태아심장수술의 기반기술 확립)

  • 이정렬;박천수;임홍국;배은정;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • Background: We tested the effect of indomethacine and total spinal anesthesia on the improvement of placental flow during cardiopulmonary bypass on fetal lamb. Material and Method: Twenty fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Ten served as a control group in which placenta was worked as an oxygenator during bypass (Control group). The remainder worked as an experimental group in which pretreatment with indomethacine and total spinal anesthesia was performed before bypass with the same extracorporeal circulation technique as control group (Experimental group). Observations were made every 10 minutes during a 30-minute bypass and 30-minute post bypass period. Result: Weights of the fetuses ranged from 2.2 to 5.2 kg. In Control group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of Pa$CO_2$ increased from 61.9 to 129.6 mmHg at each time points during bypass. Flow rate was suboptimal (74.3 to 97.0 $m\ell$/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. On the contrary, in Experimental group, means of arterial pressure reamined higher (45.8 to 30 mmHg) during bypass (p<0.05). Means of Pa$CO_2$ were less ranging from 59.8 to 79.4 mmHg during bypass (P<0.05). Flow rates were higher (78.8 to 120.2 $m\ell$/kg/min) during bypass (p<0.05). There were slower deterioration of cardiac function after cessation of bypass. Conclusion: In this study, we demonstrated that the placental flow was increased during fetal cardiopulmonary bypass in the group pretreated with indomethacine and total spinal anesthesia. However, further studies with modifications of the bypass including a creation of more concise bypass circuit, and a use of axial pump are mandatory for the clinical application.

The Recovery of Left Ventricular Function after Coronary Artery Bypass Grafting in Patients with Severe Ischemic Left Ventricular Dysfunction: Off-pump Versus On-pump (심한 허혈성 좌심실 기능부전 환자에서 관상동맥우회술시 체외순환 여부에 따른 좌심실 기능 회복력 비교)

  • Kim Jae Hyun;Kim Gun Gyk;Baek Man Jong;Oh Sam Sae;Kim Chong Whan;Na Chan-Young
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.116-122
    • /
    • 2005
  • Background: Adverse effects of cardiopulmonary bypass can be avoided by 'Off-pump' coronary artery bypass (OPCAB) surgery. Recent studies have reported that OPCAB had the most beneficial impact on patients at highest risk by reducing bypass-related complications. The purpose of this study is to compare the outcome of OPCAB and conventional coronary artery bypass grafting (CCAB) in patients with poor left ventricular (LV) function. Material and Method: From March 1997 to February 2004, seventy five patients with left ventricular ejection fraction (LVEF) of $35\%$ or less underwent isolated coronary artery bypass grafting at our institute. Of these patients, 33 patients underwent OPCAB and 42 underwent CCAB. Preoperative risk factors, operative and postoperative outcomes, including LV functional change, were compared and analysed. Result: Patients undergoing CCAB were more likely to have unstable angina, three vessel disease and acute myocardial infarction among the preoperative factors. OPCAB group had significantly lower mean operation time, less numbers of total distal anastomoses per patient and less numbers of distal anastomoses per patient in the circumflex territory than the CCAB group. There was no difference between the groups in regard to in-hospital mortality $(OPCAB\; 9.1\%\;(n=3)\;Vs.\;CCAB\;9.5\%\;(n=4)),$ intubation time, the length of stay in intensive care unit and in hospital postoperatively. Postoperative complication occurred more in CCAB group but did not show statistical difference. On follow-up echocardiography, OPCAB group showed $9.1\%$ improvement in mean LVEF, 4.3 mm decrease in mean left ventricular end-diastolic dimension (LVEDD) and 4.2 mm decrease in mean left ventricular end-systolic dimension (LVESD). CCAB group showed $11.0\%$ improvement in mean LVEF, 5.1 mm decrease in mean LVEDD and 5.5 mm decrease in mean LVESD. But there was no statistically significant difference between the two groups. Conclusion: This study showed that LV function improves postoperatively in patients with severe ischemic LV dysfunction, but failed to show any difference in the degree of improvement between OPCAB and CCAB. In terms of operative mortality rate and LV functional recovery, the results of OPCAB were as good as those of CCAB in patients with poor LV function. But, OPCAB procedure was advantageous in shortening of operative time and in decrease of complications. We recommend OPCAB as the first surgical option for patients with severe LV dysfunction.

Coronary Artery Bypass Grafting Using Sequential Graft of the Left Internal Mammary Artery (내유동맥 연쇄문합술을 이용한 관동맥우회로 이식술)

  • 오상기
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.167-172
    • /
    • 2000
  • Background: As the internal mammary artery is far superior to the vein in the patency rate recently there has been a tendency to use the arterial graft as much as possible in coronary artery bypass grafts with the expectation of better the short- and long-term patency rate. Material and Method: We sequentially grafted the diagonal and the left anterior descending artery significantly influencing the cardiac function with the internal mammary artery. There were 32 cases of sequential grafts from July 1993 to December 1998: 21 men and 11 women. The age range was from 43 to 69 years with a mean age of 56.64$\pm$6.41 years. There were 22 unstable angina 7 stable angina and 3 acute myocardial infarction. 8 cases of them were accompanied by stenosis of the left main coronary artery. The grafts for coronary artery bypass surgery included the great saphenous vein at 60 the right gastroepiploci artery at 5 and the left internal mammary artery at 64 coronary arteries. Result: One patient died from sepsis and multiorgan failure. Complications included wound infections in two cases and gastrointestinal bleeding in one patient. All patients showed decrease or disappearance of angina after operation. The postoperative coronary angiogram performed in 9 patients showed neither occlusion nor stenosis of the grafts. Conclusion: This study suggests that sequential anastomosis of the internal mammary artery to the diagonal and the left anterior descending artery may result in excellent short-term patency diagonal and the left anterior descending artery may result in excellent short-term patency rate and be useful for the coronary artery bypass graft using only arterial grafts

  • PDF

Blood Protein Adsorption and Platelet Activation on an Ultra-hydrophilic Substrate (초친수성 표면에서 혈장 단백의 흡착 및 혈소판의 변화에 관한 연구)

  • Park, Nam-Hee;Chun, Bae-Hyeock;Je, Hyung-Gon;Lee, Jun-Wan;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.273-279
    • /
    • 2007
  • Background: We evaluate the efficacy of ultra-hydrophilic coated bypass circuits in comparison with uncoated bypass circuits in a porcine cardiopulmonary bypass model. Material and Method: Normothermic cardiopulmonary bypass was peformed in 10 anesthetized pigs via the left atrium and ascending aorta with a centrifugal biopump. Ultra-hydrophilic coated bypass circuits wore used in 5 pigs (the study group) and uncoated bypass circuits were used for the control group. Platelet counts and platelet aggregation tests were peformed. The thrombin-antithrombin(TAT) complex level and total protein level were evaluated. Result: There were no significant changes En the platelet counts and aggregation ability of both groups. The TAT complex levels were not different between the two groups. The total protein level was significantly lower in the control group after cessation of cardiopulmonary bypass. Conclusion: The clinical effects of ultra-hydrophilic coating circuits were not remarkable, in terms of reducing inflammatory reaction and protection of platelet function. However, the effect of protection for blood protein adsorption might be acceptable.