• Title/Summary/Keyword: Bypass Algorithm

Search Result 50, Processing Time 0.026 seconds

A Study on Voice Quality and Speed Upgrade for Internet phone System (인터넷폰 시스템의 음질 및 속도향상연구)

  • 임종설;김성호;조남인;오춘석
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.5
    • /
    • pp.631-640
    • /
    • 2002
  • The internet phones that are currently available in use adopt packet exchange system, transferring through various routes and lacking sufficient band width with a result that there is an accompanied delay for packet transmission since the traffic is increased, accordingly affecting a lot in sound quality and speed. Two solutions for such troubles are suggested in this study to improve sound quality of internet phones. Firstly, we minimize the delay and damage regarding packet size based on traffic size by using the data algorithm from variable packets in order to supplement decreased sound quality due to the delay and damage of sound data. The second suggestion is to employ a method of Jitter compensation by giving an appropriate initial delay time with regenerating buffers to bypass troubles from Jitter, From employing the Jitter compensation method, we found that there is a sound quality improvement due to the less stoppage phenomenon.

  • PDF

Motion Estimation and Mode Decision Algorithm for Very Low-complexity H.264/AVC Video Encoder (초저복잡도 H.264 부호기의 움직임 추정 및 모드 결정 알고리즘)

  • Yoo Youngil;Kim Yong Tae;Lee Seung-Jun;Kang Dong Wook;Kim Ki-Doo
    • Journal of Broadcast Engineering
    • /
    • v.10 no.4 s.29
    • /
    • pp.528-539
    • /
    • 2005
  • The H.264 has been adopted as the video codec for various multimedia services such as DMB and next-generation DVD because of its superior coding performance. However, the reference codec of the standard, the joint model (JM) contains quite a few algorithms which are too complex to be used for the resource-constraint embedded environment. This paper introduces very low-complexity H.264 encoding algorithm which is applicable for the embedded environment. The proposed algorithm was realized by restricting some coding tools on the basis that it should not cause too severe degradation of RD-performance and adding a few early termination and bypass conditions during the motion estimation and mode decision process. In case of encoding of 7.5fps QCIF sequence with 64kbpswith the proposed algorithm, the encoder yields worse PSNRs by 0.4 dB than the standard JM, but requires only $15\%$ of computational complexity and lowers the required memory and power consumption drastically. By porting the proposed H.264 codec into the PDA with Intel PXA255 Processor, we verified the feasibility of the H.264 based MMS(Multimedia Messaging Service) on PDA.

A Study on Water Level Control of PWR Steam Generator at Low Power Operation and Transient States (저출력 및 과도상태시 원전 증기발생기 수위제어에 관한 연구)

  • Na, Nan-Ju;Kwon, Kee-Choon;Bien, Zeungnam
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.3 no.2
    • /
    • pp.18-35
    • /
    • 1993
  • The water level control system of the steam generator in a pressurized water reactor and its control problems are analysed. In this work the stable control strategy during the low power operation and transient states is studied. To solve the problem, a fuzzy logic control method is applied as a basic algorithm of the controller. The control algorithm is based on the operator's knowledges and the experiences of manual operation for water level control at the compact nuclear simulator set up in Korea Atomic Energy Research Institute. From a viewpoint of the system realization, the control variables and rules are established considering simpler tuning and the input-output relation. The control strategy includes the dynamic tuning method and employs a substitutional information using the bypass valve opening instead of incorrectly measured signal at the low flow rate as the fuzzy variable of the flow rate during the pressure control mode of the steam generator. It also involves the switching algorithm between the control valves to suppress the perturbation of water level. The simulation results show that both of the fine control action at the small level error and the quick response at the large level error can be obtained and that the performance of the controller is improved.

  • PDF

Development of the HPM System to Improve Efficiency of the Hydraulic Excavator (유압식 굴삭기 효율 향상을 위한 HPM 시스템 개발)

  • Kwon, Yong Cheol;Lee, Kyung Sub;Kim, Sung Hun;Koo, Byoung Kook
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2019
  • The HPM (High-speed Power Matching) system is an electro-hydraulic control system. It directly controls the swash plate of the pump by selecting four-loop logic based on joystick signals, pump flow, and pressure signal to improve the efficiency and controllability of construction machines. In the NFC (Negative Flow Control) system, a typical pump control system using conventional open center type MCV, the loss is continuously generated by flow through the center bypass line even when the excavator is not in operation. Also, due to the slow response of the pump that indirectly controls the flow rate using the pressure regulator, peak pressure occurs at the start or stop of the operation. Conversely, the HPM system uses an MCV without center-by-pass flow path and the swash plate of a pump for the HPM is controlled by a high-speed proportional flow control valve. As a result, the HPM system minimizes energy loss in standby state of the excavator and enables peak pressure control through rapid electro-hydraulic control of a pump. In this paper, the concept of the HPM system algorithm is introduced and the hydraulic system efficiency is compared with the NFC system using the excavator SAT (System Analysis Tool).

Design of an Efficient Binary Arithmetic Encoder for H.264/AVC (H.264/AVC를 위한 효율적인 이진 산술 부호화기 설계)

  • Moon, Jeon-Hak;Kim, Yoon-Sup;Lee, Seong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.12
    • /
    • pp.66-72
    • /
    • 2009
  • This paper proposes an efficient binary arithmetic encoder for CABAC which is used one of the entropy coding methods for H.264/AVC. The present binary arithmetic encoding algorithm requires huge complexity of operation and data dependency of each step, which is difficult to be operated in fast. Therefore, renormalization exploits 2-stage pipeline architecture for efficient process of operation, which reduces huge complexity of operation and data dependency. Context model updater is implemented by using a simple expression instead of transIdxMPS table and merging transIdxLPS and rangeTabLPS tables, which decreases hardware size. Arithmetic calculator consists of regular mode, bypass mode and termination mode for appearance probability of binary value. It can operate in maximum speed. The proposed binary arithmetic encoder has 7282 gate counts in 0.18um standard cell library. And input symbol per cycle is about 1.

Reconstruction of Myocardial Current Distribution Using Magnetocardiogram and its Clinical Use (심자도를 이용한 심근 전류분포 복원과 임상적 응용)

  • 권혁찬;정용석;이용호;김진목;김기웅;김기영;박기락;배장호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.459-464
    • /
    • 2003
  • The source current distribution in a heart was reconstructed from the magnetocardiogram (MCG) and its clinical usefulness was demonstrated. MCG was measured using 40-channel superconducting quantum interference device (SQUID) gradiometers for a patient of Wolff-Parkinson-White (WPW) syndrome, which has an accessory pathway between the atria and the ventricles. Reconstruction of source current distribution in a plane below the chest surface was performed using minimum norm estimation (MNE) algorithm and truncated singular value decomposition (SVD), In the simulation, we confirmed that the current distributions. which were computed for the test dipoles, represented well the essential feature of the test current configurations, In the current map of WPW syndrome, we observed abnormal currents that would bypass the atrioventricular junction at a delta wave. However, we could not observe such currents any more after the surgery. These results showed that the obtained current distribution using MCG signals is consistent with the electrical activity in a heart and has clinical usefulness.

A Fuzzy Controller for the Steam Generator Water Level Control and Its Practical Self-Tuning Based on Performance (증기발생기 수위제어를 위한 퍼지제어기 구현 및 제어성능지수를 이용한 제어기 의 Self-Tuning)

  • Na, Nan-Ju;Bien, Zeun-Gnam
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.317-326
    • /
    • 1995
  • The oater level control system of the steam generator in a pressurized water reactor and its control Problems are analysed. In this work a stable control strategy Particularly during low Power operation based on the fuzzy control method is studied. The control strategy employs substitutional information using the bypass valve opening instead of incorrectly measured signal at the low How rate as the fuzzy variable of the flow rate during low power operation, and includes the flexible scale adjusting method for fast response at a large transient. A self-tuning algorithm based on the control performance and the descent method is also suggested for tuning the membership function scale. It gives a practical way to tune the controller under real operation. Simulation was carried out on the Compact Nuclear Simulator set up at Korea Atomic Energy Research Institute and its result showed the good performance of the controller and effectiveness of its tuning.

  • PDF

Electromagnetic and Thermal Information Utilization System to Improve The Success Rate of Laser Fault Injection Attack (레이저 오류 주입 공격 성공률 향상을 위한 전자파 및 열 정보 활용 시스템)

  • Mun, HyeWon;Ji, Jae-deok;Han, Dong-Guk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.32 no.5
    • /
    • pp.965-973
    • /
    • 2022
  • As IoT(Internet of Things) devices become common, many algorithms have been developed to protect users' personal information. The laser fault injection attack that threatens those algorithms is a side-channel analysis that intentionally injects a laser beam to the outside of a device to acquire confidential information or abnormal privileges of the system. There are many studies to determine the timing of fault injection to reduce the number of necessary fault injections, but the location to inject faults is only repeatedly searched for the entire area of the device. However, when fault injection is performed in an algorithm-independent area, the attacker cannot obtain the intended faulted statement or attempt to bypass authentication, so finding areas vulnerable to fault injection and performing an attack is an important consideration in achieving a high attack success rate. In this paper, we show that a 100% attack success rate can be achieved by determining the vulnerable areas for fault injection by using electromagnetic and thermal information generated from the device's chip. Based on this, we propose an efficient fault injection attack system.

OLE File Analysis and Malware Detection using Machine Learning

  • Choi, Hyeong Kyu;Kang, Ah Reum
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.5
    • /
    • pp.149-156
    • /
    • 2022
  • Recently, there have been many reports of document-type malicious code injecting malicious code into Microsoft Office files. Document-type malicious code is often hidden by encoding the malicious code in the document. Therefore, document-type malware can easily bypass anti-virus programs. We found that malicious code was inserted into the Visual Basic for Applications (VBA) macro, a function supported by Microsoft Office. Malicious codes such as shellcodes that run external programs and URL-related codes that download files from external URLs were identified. We selected 354 keywords repeatedly appearing in malicious Microsoft Office files and defined the number of times each keyword appears in the body of the document as a feature. We performed machine learning with SVM, naïve Bayes, logistic regression, and random forest algorithms. As a result, each algorithm showed accuracies of 0.994, 0.659, 0.995, and 0.998, respectively.

Control Algorithm Characteristic Study of Cooling System for Automotive Fuel Cell Application. (차량용 연료전지 냉각시스템 제어 알고리즘 특성 연구)

  • Han, Jae Young;Park, Ji Soo;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • Thermal management of a fuel cell is important to satisfy the requirements of durability and efficiency under varying load conditions. In this study, a linear state feedback controller was designed to maintain the temperature within operating conditions. Due to the nonlinearity of automotive fuel cell system, the state feedback controller results in marginal stable under load condition from $0.5A/cm^2$ to $0.7A/cm^2$. A PWM (Pulse Width Modulation) and the modified state feedback controller are applied to control the temperature under the load condition from $0.5A/cm^2$ to $0.7A/cm^2$. The cooling system model is composed of a reservoir, radiator, bypass valve, fan, and a water pump. The performance of the control algorithm was evaluated in terms of the integral time weighted absolute error (ITAE). Additionally, MATLAB/SIMULINK$^{(R)}$ was used for the development of the system models and controllers. The modified state feedback controller was found to be more effective for controlling temperature than other algorithms when tested under low load conditions.