• 제목/요약/키워드: Burner fire

검색결과 64건 처리시간 0.029초

침대 매트리스 실규모 화재안전 평가시스템 기술 (Description on assessment system of bed mattress's fire safety in real scale)

  • 박계원;정재군
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.329-332
    • /
    • 2012
  • This study focuses on the establishment of bed mattress fire test in real scale where it explains the burner heat supply, test procedure and test report in detail. Especially burner system is dealt in importance for bed mattress test in real scale due to simulating in bedding component by burner heat out-put.

  • PDF

가스계 혼합소화약제의 불꽃소화농도 (Flame Extinguishing Concentrations of Mixed Gaseous Agents)

  • 김재덕;임종성;이윤우;이윤용
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.34-40
    • /
    • 2001
  • 가스계 혼합소화약제의 소화성능을 검토하기 위하여 Cup-burner test장치를 설치하고 이성분계 및 삼성분계 혼합물의 불꽃소화농도를 측정하였다. 시험대상 이성분계 혼합물은 이산화탄소/HFC-23, 이산화탄소/HCFC-22, 이산화탄소/HFC-227ea, 이산화탄소/HFC-125, 이산화탄소/FIC-13I1, Hexafluoropropylene/HFC-23이고 삼성분계 흔합물은 이산화탄소/HFC-237HFC-l34a, 이산화탄소/HFC-23/HFC-227ea, 이산화탄소/HFC-23/HFC-125이다. Cup-burner test장치에서 측정된 가스계 혼합물의 소화농도는 단일성분의 소화농도와 혼합물의 구성비로 이루어진 모델에 의해 잘 예측됨을 알 수 있었다. 특히 이 모델은 혼합물의 구성성분이 물리적 소화성능을 지닐 때 잘 적용되며 화학적 소화성능의 영향이 강해질수록 측정값과의 오차가 커진다.

  • PDF

열매유 보일러 내부화재에 따른 온도 및 속도분포 해석 (Temperature and Flow Velocity Analysis for Fire in Synthetic Heat Transfer Fluid Boiler)

  • 김엽래;손봉세
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.19-25
    • /
    • 2013
  • 열매유(Synthetic Heat Transfer Fluid)의 가열현상으로 인하여 보일러에서 화재가 발생한 경우에 대하여 컴퓨터 수치해석을 통한 1, 2, 3차 패스 및 연소대의 온도 및 속도분포를 파악하였다. 보일러의 인버터의 고장으로 인하여 보일러 내부의 유동이 다소 불안전한 상태에서 운전이 지속되면서 화염의 유동과 속도가 불안정하게 작동된 것으로 판단된다. 열매유의 누유현상은 화재초기에 약 120 kg/min로 분출하면서 기화되었고, 또한 화염은 2차 패스와 3차 패스까지 열전달 현상이 확대되었다. 2차 패스에서의 최고온도는 $1,059^{\circ}C$, 3차 패스의 최고온도는 $1,007^{\circ}C$이고, 3차 패스 아래쪽에서는 온도가 $767^{\circ}C$인 것으로 컴퓨터 시뮬레이션 결과에서 알 수 있었다. 특히, 연소대는 1차 패스 균열부위에서 열매유가 분출되면서 턴테이블 위로 쌓였으며, 연소대 하부에서 온도는 플래시오버 현상에 의하여 $183^{\circ}C$까지 올라갔다. 따라서 연소대 내부의 온도는 $1,200^{\circ}C$ 이상으로 예측되었으며, 연소대의 온도는 순간적으로 여러 차례 최고점의 온도까지 도달되어 연소대에서 여러 차례 폭발현상이 발생한 것으로 판단되었다.

연소로의 화염분포가 보일러 관로에 미치는 영향에 관한 연구 (A Study on the Imfluence of the Pipe Line of Boiler for Flame Distribution of Combustion Furnace)

  • 조동현
    • 수산해양교육연구
    • /
    • 제26권6호
    • /
    • pp.1435-1441
    • /
    • 2014
  • The fire took place in the synthetic heat transfer fluid boiler used in production process of medium density fiberboard. This study investigated pressure distribution of the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner. Pressure distribution at steady state in combustion furnace is 2~5mAq and pressure distribution at inverter under fault condition in combustion furnace is 10~-53mAq. The decrement of coil thickness measurement for synthetic heat transfer fluid boiler is 0~5mm.

불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성 (Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents)

  • 김재덕;김영래;홍승태;이성철
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.77-83
    • /
    • 2002
  • 질소, 아르곤, 이산화탄소와 같은 불활성가스 및 이들의 혼합물을 소화약제로 하여 n-Heptane을 연료로한 cup-burner test 장치에서 불꽃소화농도와 연소시 배가스의 조성을 측정하였다. 이성분 불활성가스계 혼합소화약제의 소화농도는 혼합물의 구성비를 이용한 모델에 의해 잘 예측됨을 알 수 있었다. 불활성 가스계 혼합 소화약제에 의한 소화작용에 있어서 혼합가스의 평균비중이 클수록 소화 성능이 우수하였다. 또한 밀폐된 공간의 구조가 소화에 영향을 미칠 수 있음을 확인하였다. 연소시 배가스 중 이산화탄소 조성은 사용하는 소화약제의 양이 증가할수록 감소하였다. 일산화질소 발생은 소화약제의 질소 함량과는 상관이 없으며 공기유량을 크게 하여 불꽃을 크게 했을 때 검출되었다.

다단 연소 버너의 보일러 연소실에서의 연소 특성 (Combustion Characteristics of a Staged Burner for a Boiler)

  • 안준;김종진;강새별
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.767-772
    • /
    • 2009
  • The demand for a boiler with low NOx burner is increasing with the recent strict NOx regulation. Staged burner is a common low NOx burner to suppress the formation of thermal NOx by yielding local fuel rich and lean condition. The staged burner gives fire with bigger frontal area and length compared with a conventional burner, which changes heat transfer characteristics in the combustion chamber. The heat transfer and exhaust gas characteristics have been studied in the present study for a 0.5 t/h class furnace type boiler adopting the staged burner. A numerical simulation has been conducted to clarify the detailed physics inside the combustion chamber.

다단 연소 버너의 보일러 연소실에서의 연소 특성 (Combustion Characteristics of a Staged Burner for a Boiler)

  • 안준;김종진;강새별
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.555-558
    • /
    • 2008
  • The demand for a boiler with low NOx burner is increasing with the recent strict NOx regulation. Staged burner is a common low NOx burner to suppress the formation of thermal NOx by yielding local fuel rich and fuel lean condition. The staged burner gives fire with bigger frontal area and length compared with a conventional burner, which changes heat transfer characteristics in the combustion chamber. The heat transfer and exhaust gas characteristics has been studied in the present study for a 0.5 t/h class furnace type boiler adopting the staged burner. A numerical simulation has been conducted to clarify the detailed physics inside the combustion chamber.

  • PDF

질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구 (A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas)

  • 임우섭;정종진;남동군;사공성호;김종원;최근주
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

불활성 가스 발생장치(Inert Gas Generator) 소화시스템 적용에 관한 연구 (A Study of the Application of Inert Gas Generator to the Fire Extinguishing System)

  • 한용식;김명배;김수용
    • 한국화재소방학회논문지
    • /
    • 제19권2호
    • /
    • pp.69-74
    • /
    • 2005
  • 대량의 비활성가스를 발생시키는 Inert Gas Generator(IGG)를 소화설비로 사용하기 위해 본 연구에서는 가스터빈을 채용한 IGG에서 발생되는 배기가스의 소화성능을 검토하였다. IGG에서 발생하는 가스는 조성을 동일하게 만든 모사 혼합가스를 이용하였으며, Cup Burner시험방법으로 소화농도를 측정하였다. 얻어진 소화농도를 NFPA 2001에서 권장하는 방법에 적용하여 소화설계 농도 및 소화공간 크기를 산정하였다. 또한, $2m\times2m\times2m$ 크기의 공간에서 화재진압 실험을 수행하여 실제 소화성능을 확인하였다.

An Experimental Study on the H-Beam Under Fire Load in Open Space

  • Ki, Min Suk;Park, Beom Jin;Lee, Kangsu;Park, Byoungjae;Fernandez, Kyle;Nho, In Sik
    • 한국해양공학회지
    • /
    • 제35권1호
    • /
    • pp.59-74
    • /
    • 2021
  • To validate the fire safety assessment of structures, many structural experiments under fire load have been conducted. However, most of these experiments were conducted in restricted environments, such as inside a furnace, and experiments were seldom carried out in open space. In this study, an experimental study on H-beams, frequently used as structural reinforcements, was carried out for validating the thermal-structural analysis method under development. A 1.8 MW burner fire was adopted with each end of the H-beam fixed without a mechanical load. Gas temperature, steel surface temperature, and displacements were then measured. During the experiment, gas and steel temperatures were obtained at 9 and 17 points near the H-beam, respectively. In addition, the vertical and horizontal displacements of the H-beam under fire load at 6 points were obtained. Furthermore, it was verified that the stable displacement measurements via the contact and non-contact methods were feasible in harsh environments where flames and smoke were both present.