• Title/Summary/Keyword: Burner fire

Search Result 64, Processing Time 0.026 seconds

Description on assessment system of bed mattress's fire safety in real scale (침대 매트리스 실규모 화재안전 평가시스템 기술)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.329-332
    • /
    • 2012
  • This study focuses on the establishment of bed mattress fire test in real scale where it explains the burner heat supply, test procedure and test report in detail. Especially burner system is dealt in importance for bed mattress test in real scale due to simulating in bedding component by burner heat out-put.

  • PDF

Flame Extinguishing Concentrations of Mixed Gaseous Agents (가스계 혼합소화약제의 불꽃소화농도)

  • 김재덕;임종성;이윤우;이윤용
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.34-40
    • /
    • 2001
  • Fire extinguishing efficiency of mixed gaseous agents were investigated by the cup-burner test and predicting by the model of flame extinguishing concentration. The binary mixed agents that tested were carbon dioxide/HFC-23, carbon dioxide/HCFC-22, carbon dioxide/HFC-227ea, carbon dioxide/HFC-125, carbon dioxide/FIC-13I1, Hexafluoropropylene/HFC-23 and ternary mixed agents were carbon dioxide/HFC-23/HFC-l34a, carbon dioxide/HFC-23/HFC-227ea, carbon dioxide/HFC-23/HFC-125. A model which contains the flame extinguishing concentration and composition of pure components predicted the flame extinguishing concentration of mixture well. This model was superior when each component of the mixture exhibit physical fire extinguishing performance.

  • PDF

Temperature and Flow Velocity Analysis for Fire in Synthetic Heat Transfer Fluid Boiler (열매유 보일러 내부화재에 따른 온도 및 속도분포 해석)

  • Kim, Yeob-Rae;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.19-25
    • /
    • 2013
  • The fire took place in the synthetic heat transfer fluid boiler. This study uses simulation to investigate the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is more or less unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120 kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The simulation shows that the temperature is $767^{\circ}C$ in the low part of the third pass. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. The temperature rises to $183^{\circ}C$ in the low part of the burner. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner.

A Study on the Imfluence of the Pipe Line of Boiler for Flame Distribution of Combustion Furnace (연소로의 화염분포가 보일러 관로에 미치는 영향에 관한 연구)

  • Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1435-1441
    • /
    • 2014
  • The fire took place in the synthetic heat transfer fluid boiler used in production process of medium density fiberboard. This study investigated pressure distribution of the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner. Pressure distribution at steady state in combustion furnace is 2~5mAq and pressure distribution at inverter under fault condition in combustion furnace is 10~-53mAq. The decrement of coil thickness measurement for synthetic heat transfer fluid boiler is 0~5mm.

Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents (불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성)

  • 김재덕;김영래;홍승태;이성철
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.77-83
    • /
    • 2002
  • We measured flame extinguishing concentration and flue gas composition in the n-heptane fuel cup-burner system using inert gas agents such as nitrogen, argon, carbon dioxide and their mixtures. The flame extinguishing concentration of binary gaseous mixture was well predicted by model which contains the flame extinguishing concentration and composition of pure components. The higher average specific gravity of the mixed inert gas agents, the more excellent flame extinguishing performance. And the structure of enclosed space also affects the fire extinguishing. The composition of carbon dioxide in the flue gas was decreased with increasing extinguishing agent used. Nitrogen monoxide production is not related with increasing nitrogen, but increased at rapid mass flow rate of air in the cup-burner.

Combustion Characteristics of a Staged Burner for a Boiler (다단 연소 버너의 보일러 연소실에서의 연소 특성)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.10
    • /
    • pp.767-772
    • /
    • 2009
  • The demand for a boiler with low NOx burner is increasing with the recent strict NOx regulation. Staged burner is a common low NOx burner to suppress the formation of thermal NOx by yielding local fuel rich and lean condition. The staged burner gives fire with bigger frontal area and length compared with a conventional burner, which changes heat transfer characteristics in the combustion chamber. The heat transfer and exhaust gas characteristics have been studied in the present study for a 0.5 t/h class furnace type boiler adopting the staged burner. A numerical simulation has been conducted to clarify the detailed physics inside the combustion chamber.

Combustion Characteristics of a Staged Burner for a Boiler (다단 연소 버너의 보일러 연소실에서의 연소 특성)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.555-558
    • /
    • 2008
  • The demand for a boiler with low NOx burner is increasing with the recent strict NOx regulation. Staged burner is a common low NOx burner to suppress the formation of thermal NOx by yielding local fuel rich and fuel lean condition. The staged burner gives fire with bigger frontal area and length compared with a conventional burner, which changes heat transfer characteristics in the combustion chamber. The heat transfer and exhaust gas characteristics has been studied in the present study for a 0.5 t/h class furnace type boiler adopting the staged burner. A numerical simulation has been conducted to clarify the detailed physics inside the combustion chamber.

  • PDF

A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas (질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구)

  • Lim, Woo-Sub;Jung, Jong-Jin;Nam, Dong-gun;SaKong, Seong-Ho;Kim, Jong-Won;Choi, Kenu-Joo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

A Study of the Application of Inert Gas Generator to the Fire Extinguishing System (불활성 가스 발생장치(Inert Gas Generator) 소화시스템 적용에 관한 연구)

  • Han Yong-Shik;Kim Myoung-Bae;Kim Su-Yong
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.69-74
    • /
    • 2005
  • A study of the utilization of inert gas generator(IGG) that generates a large amount of inert gas for the fire extinguishing equipment was performed. In this study, the fire extinction performance of gas generated from a 1GG which is implemented to a gas turbine was investigated. A simulated mixture gas of which composition is the same as that of the gas generated from ICG was used in all experiments. First, the extinction concentration was measured using a cup burner method. The extinction design concentration and the volume of extinction space was calculated by applying the obtained extinction concentration to a method recommended by NFPA 2001. In practical respects, the fire extinction performance of IGG-generated gas was confirmed through the fire suppression experiment within a $2m\times2m\times2m$ room.

An Experimental Study on the H-Beam Under Fire Load in Open Space

  • Ki, Min Suk;Park, Beom Jin;Lee, Kangsu;Park, Byoungjae;Fernandez, Kyle;Nho, In Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.59-74
    • /
    • 2021
  • To validate the fire safety assessment of structures, many structural experiments under fire load have been conducted. However, most of these experiments were conducted in restricted environments, such as inside a furnace, and experiments were seldom carried out in open space. In this study, an experimental study on H-beams, frequently used as structural reinforcements, was carried out for validating the thermal-structural analysis method under development. A 1.8 MW burner fire was adopted with each end of the H-beam fixed without a mechanical load. Gas temperature, steel surface temperature, and displacements were then measured. During the experiment, gas and steel temperatures were obtained at 9 and 17 points near the H-beam, respectively. In addition, the vertical and horizontal displacements of the H-beam under fire load at 6 points were obtained. Furthermore, it was verified that the stable displacement measurements via the contact and non-contact methods were feasible in harsh environments where flames and smoke were both present.