• Title/Summary/Keyword: Burned gas analysis

Search Result 30, Processing Time 0.03 seconds

Analysis of the flow field in two-stroke engine cylinder of different intake ports angles (포트각도에 따른 2행정기관 실린더내의 유동장 해석)

  • 홍기배;최영진;유홍선;정인식
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.55-66
    • /
    • 1993
  • The characteristics of the flow processes in the cylinder of the two-stroke cycle engines have become the subject of increasing and attention owing to the simplicity and the higher power per unit weight of the two-stroke cycle engine. Among the many factors which influence on the scavenging flow, the port angle is important factor. Hence, four different type models with one inlet-port and two side-ports are studied to show the effect of port angle on the laminar scavenging flow. When the inlet-port axial is relatively larger than the side-port axial angle, it is showed that the fresh charge penetrate into the burned gas and displace it first toward the cylinder head and then toward the exhaust port. When the inlet-port axial angle is much less than the side-port axial angle, the fresh charge through the inlet-port directly move toward the exhaust port. The result showed that the model A may suppress the generation of vortices in the vicinity of inlet and side prots which restrict the sufficient supply of fresh charge and obstruct the perfect displacement of all combustion products.

  • PDF

Numerical research for Gate Type Waste Incinerators In Environment energy facilities (환경에너지시설내 화격자식 소각로 수치해석 연구)

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.149-155
    • /
    • 2017
  • This study is analyzed combustion phenomena based on the environmental energy facility incinerator. It is assumed that combustible components of waste are composed of carbon and hydrogen, and the combustion process of fuel is by setting as multi-component / multistage reaction. As the combustion chamber is burned, the high temperature environment is achieved, also the heat transfer accompanied by the turbulent flow and the generation of NOx, a pollutant, are interpreted to predict the thermal and fluid characteristics and pollution emissions of the grate incinerator. As the result of internal flow analysis, the slow flow around the ash chute and the mixing effect due to the complicated turbulence around the combustion chamber were predicted to show excellent performance. It is shown to the internal average temperature was about $1024^{\circ}C$, around the about $1000^{\circ}C$ homogeneous temperature distribution. Due to the sudden temperature decrease in the boiler, the flue gas temperature at the outlet was estimated to be about $220^{\circ}C$.

An Experimental Study on the Combustion Characteristics of Wastewater-Emulsion Fuel (Emulsion(B.C유+폐수)연료의 연소효율에 관한 실험적 연구)

  • 정진도
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.267-273
    • /
    • 2003
  • Emulsion fuel is a very attractive fuel because of its energy saving and pollution prevention properties. We investigated and compared the combustion efficiency of B-C oil and emulsion fuel i.e. fuel made from the mixture of B-C oil and waste water. By installing an R-type thermocouple and an optical pyrometer on each side of the boiler, and by placing a combustion analyzer at the point of gas emissions, We were able to measure and compare each flame temperature, combustion rate and the concentration of emitted gas when B-C oil and emulsion fuel are burned. The following results were obtained: The flame temperature of emulsion fuel at the front and rear of the boiler is about 50$^{\circ}C$ lower than the flame temperature of B-C oil. The reason for this difference in temperature is that both latent and sensible heat is lost due to the moisture in the waste water of emulsion fuel. An analysis of emitted gases shows that when emulsion fuel is used polluting substances decrease also the concentration of CO becomes considerably lower. The combustion efficiency for B-C oil and emulsion fuel is 85.5% and 84.8% respectively.

Combustion Characteristics of Landfill Gas in Constant Volume Combustion Chamber for Large Displacement Volume Engine (I) - Fundamental Characteristics - (대형기관 모사 정적연소실에서 매립지 가스의 연소특성에 대한 연구 (I) - 기초 특성 -)

  • Ohm, Inyong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.733-741
    • /
    • 2013
  • This is the first paper on the combustion characteristics of landfill gas in a constant volume combustion chamber for a large displacement volume commercial engine, and it discusses the fundamental characteristics of fuel from the viewpoint of thermochemistry and thermodynamics and compares these results with experimental ones. The results show that the final pressures obtained from theoretical analysis vary under the same heating value owing to the change in the constant volume specific heat owing to the difference in the burned gas composition according to the fuel gas compositions; furthermore, the stoichiometric ratios and trends of analytical and experimental pressures coincide very well, although some minor differences are observed between the two. The root cause of the difference is the heat transfer, which changes the specific heat and lowers the temperature considerably, in the real combustion process. In addition, the large chamber volume and ignition position promote the heat transfer to the wall. Finally, the fuel conversion efficiency increases as the methane mol fraction decreases, and it is maximum when the stoichiometric ratio ranges from 0.8 to 0.9. These increases due to the composition and stoichiometric ratio could sufficiently compensate the decrease due to the specific heat ratio drop, LFG might be more advantageous than pure methane in a real engine.

The study of quantitative analysis for noxious gases of plastic materials by remote sensing open path FT-IR spectrometer (원격 측정용 개방 경로형 FT-IR spectrometer를 사용하여 플라스틱 재료의 유해 가스 정량 분석에 관한 연구)

  • Cho, Nam-Wook;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.230-235
    • /
    • 2012
  • It is to use many plastic materials as living essential goods. But when the fire is happened, owing to noxious gases, many men should be injured. Therefore as the noxious gases are measured by open path FT-IR spectrometer as remote monitoring, the demage of men could be minimized. Such this system consists of a Fourier transform spectrometer and infrared lamp fitted to long length. The study was to do the quantitative analysis on CO, $NO_2$, HCl, HF gas by remote monitoring open path FT-IR spectrometer. And the method of it should use MLR (multiple linearity regression) method. As result, It was confirmed to be more than 0.95 as $R^2$ of MLR. And then Urethane and PVC of plastic materials selected was burned, the concentration of polluted gases were measured by remote monitoring method.

CO2 Emission Characteristics of Bunker C Fuel Oil by Sulfur Contents (C 중유의 황 함유량에 따른 CO2 배출 특성)

  • Lim, Wan-Gyu;Doe, Jin-Woo;Hwang, In-Ha;Ha, Jong-Han;Lee, Sang-Sup
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.4
    • /
    • pp.368-377
    • /
    • 2015
  • Bunker C fuel oil is a high-viscosity oil obtained from petroleum distillation as a residue. The sulfur content of bunker C fuel oil is limited to 4.0% or even lower to protect the environment. Because bunker C fuel oil is burned in a furnace or boiler for the generation of heat or used in an engine for the generation of power, carbon dioxide is emitted as a result of combustion. The objective of this study is to investigate $CO_2$ emission characteristics of bunker C fuel oil by sulfur contents. Calorific values and carbon contents of the fuels were measured using the oxygen bomb calorimeter method and the CHN elemental analysis method, respectively. Sulfur and hydrogen contents, which were used to calculate the net calorific value, were also measured and then net calorific values and $CO_2$ emission factors were determined. The results showed that hydrogen content increases and carbon content decreases by reducing sulfur contents for bunker C fuel oil with sulfur contents less than 1.0%. For sulfur contents between 1.0% and 4.0%, carbon content increases as sulfur content decreases but there is no evident variation in hydrogen content. Net calorific value increases by reducing sulfur contents. $CO_2$ emission factor, which is calculated by dividing carbon content by net calorific value, decreases as sulfur content decreases for bunker C fuel oil with sulfur contents less than 1.0% but it showed relatively constant values for sulfur contents between 1.0% and 4.0%.

Study on production RDF using organic waste and peat-moss (유기성 폐기물과 피트모스를 이용한 고형연료 제조에 관한 연구)

  • Ha, Sang An
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.3
    • /
    • pp.106-112
    • /
    • 2007
  • The purpose of this study is to derive the mixing ratio with stable heating value to be used as fuel and secondary fuel by mixing sewage sludge cake, tar, peat moss, and verify the combustion property of produced solid fuel and the applicability of RDF as alternative fuel. Tar shows the highest heating value with 7,000kcal/kg and the heating value of sewage sludge cake and peat moss ranges from 4,000 to 4,500kcal/kg. Also, the solid fuel with length 1.6cm, diameter 1.3cm and weight 2.3g was produced using the heating value of over 6,000kcal/kg and proper mixing ratio (sewage sludge cake: tar: peat moss) from 1 : 4 : 1 to 1 : 7 : 1. Upon the analysis of the RDF applicability of produced solid fuel, the exhaust gas analysis finds that the composition concentration of exhaust gas occurred according to the mixing ratio did not change significantly and the flame lasting time was found to be around 5 minutes, similar to the lasting time of the same mass (2.3g) of general anthracite burned. Therefore, it can be concluded that solid fuel produced in this study can be used as fuel and secondary fuel.

  • PDF

Headspace Volatile Compounds of Krill Reaction Flavor and Its Application to Teriyaki Sauce (크릴반응향의 휘발성 향기 성분 및 데리야끼소스의 적용)

  • Kim, Kyoung-Myo;Park, Hyun-Joo;Nam, Min-Hee;Kim, Seong-Bong;Chun, Byung-Soo;Lee, Yang-Bong
    • Culinary science and hospitality research
    • /
    • v.19 no.3
    • /
    • pp.105-115
    • /
    • 2013
  • Maillard reaction flavors had been tried by using krill hydrolysate and precursors in order to develop Teriyaki sauce with the reaction flavors. Also, the study for applying krill to Teriyaki sauce had been tried by using krill instead of eel bones. To make boiled-type and grilled-type reaction flavors, krill hydrolysate was used with other precursors such as serine, glucose and glucosamine. In the dynamic analysis of headspace volatile compounds, 20 mL reaction flavor was analyzed by the combined system of purge & trap, automatic desorber, gas chromatography and mass selective detector. Three kinds of Teriyaki sauce were developed with reaction flavor, krill and eel bones, and their products were evaluated by 10 items of cooked vegetables, cooked potatoes, boiled shrimp, grilled shrimp, fishy smell, pungent aroma, burned smell, sweety aroma, chemical smell, mud smell and preference. In the results of headspace analysis, 35 and 33 volatile compounds were identified from grilled-type and boiled-type reaction flavors. Grilled-type had sulfur-containing, aliphatic compounds, alcohols, ketones, pyrazines, and other aromatic compounds, and grilled-type had aldehydes, furans, other nitrogen-containing compounds. In the sensory evaluation of Teriyaki sauce, the items of roasted shrimp and sweety aroma showed significant differences for grilled-type application to Teriyaki sauce. The above results show the possible application of grilled-type reaction flavor to Teriyaki sauce.

  • PDF

A Study on the Element Technologies in Flame Arrester of End Line (선박의 엔드라인 폭연방지기의 요소기술에 관한 연구)

  • Pham, Minh-Ngoc;Choi, Min-Seon;Kim, Bu-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.468-475
    • /
    • 2019
  • An end-line flame arrester allows free venting in combination with flame protection for vertical vent applications. End-line flame arresters are employed in various fields, especially in shipping. In flame arresters, springs are essential parts because the spring load and the spring's elasticity determine the hood opening moment. In addition, the spring has to work under a high-temperature condition because of the burning gas flame. Therefore, it is necessary to analyze the mechanical load and elasticity of the spring when the flame starts to appear. Based on simulations of the working process of a specific end-line flame arrester, a thermal and structural analysis of the spring is performed. A three-dimensional model of a burned spring is built using computational fluid dynamics (CFD) simulation. Results of the CFD analysis are input into a finite element method simulation to analyze the spring structure. The research team focused on three cases of spring loads: 43, 93, and 56 kg, correspondingly, at 150 mm of spring deflection. Consequently, the spring load was reduced by 10 kg after 5 min under a $1,000^{\circ}C$ heat condition. The simulation results can be used to predict and estimate the spring's load and elasticity at the burning time variation. Moreover, the obtained outcome can provide the industry with references to optimize the design of the spring as well as that of the flame arrester.

Characteristics study on fire-resistant paint used by TGA-IR (TGA-IR을 사용한 내화 도료의 특성에 관한 연구)

  • Cho, Nam-Wook;Shin, Hyun-Jun;Cho, Won-Bo;Lee, Seong-Hun;Rie, Dong-Ho;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.168-172
    • /
    • 2011
  • The iron frame of building could be collapsed or bent at $500^{\circ}C$. Therefore the fire-resistant paint should be applied for safety. This study performed the comparative analysis to show the characteristics of fireresistant paint. And then 12 products of fire resistant paint and 6 products of paints were used as samples. And the samples were analyzed by TGA (Thermogravimetric Analyzer) as analyzer for measuring the variation of weight on temper of weight by heating. When TGA analyzer could measure the variatiature, and FT-IR was measured for analyze gas components on variation on of weight by heating on 12 products of fire resistance, the samples showed to decrease 40% of weight to $800^{\circ}C$, and because paints had 50% to 40% of loss weight, it showed to be equal with loss weight of fire resistance paint on high temperature or was lower loss weight than it of fire resistance paints. However number 6 sample of fire resistance paints could show to decrease 20% of total weight on $800^{\circ}C$. And then in the case of FT-IR, fire resistance paints could show to have the high intensity of $CO_2$ spectrum as complete combustion. However paints could show to have the lower intensity of $CO_2$ spectrum, have the higher intensity of water spectrum. Therefore the TGA graph of result could be much different until $250^{\circ}C$. When it was burned, FT-IR spectrum could show to confirm the characteristics of fire resistance paints, and the characteristic could be confirmed on inorganic paint of fire resistance by weight loss of TGA.