• Title/Summary/Keyword: Burn-In

Search Result 1,331, Processing Time 0.025 seconds

Study of the Density of Smoke and Harmful Gases of Adhesive Indirect Moxibustion (접착식 간접구의 연기 밀도 및 유해가스 발생 확인 연구)

  • Kim, Eun-Jung;Kim, Yu-Jong;Hwang, Ji-Hoo;Cho, Hyun-Seok;Kim, Kyung-Ho;Lee, Seung-Deok;Kim, Kap-Sung
    • The Journal of Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: We measured the density of smoke and harmful gases emitted from burning adhesive indirect moxa. Through the test we aimed to find out if there was an excessive amount of smoke emitted and if it included harmful gases. Methods: 9 types of adhesive indirect moxa were chosen. The buffer layers which do not burn during treatment were removed and 10g of each moxa were made into powder and put into a holder. A smoke density chamber (Smoke Density Chamber FTT. U.K) and Fourier transform infrared spectroscopy (FT-IR I 4001. MIDAC U.S.A.) were used to measure the density of smoke and harmful gases emitted from burning moxa by ISO 5659-2 test. Results: The result of measuring maximum smoke density showed that the regular indirect adhesive moxa (A-F) emitted high density smoke of 172.1-291.4Ds. The smokeless moxas, Seoam moxas, emitted the least amount of 3.4-5.5Ds. Concentrations of 7 typical harmful gases (CO, HCl, HCN, HBr, HF, SO2, NOx) were measured and all of the moxas emitted CO due to incomplete combustion. 4 types of moxa emitted NOx and all smokless moxas emitted NOx. HBr, HCN, HCl, HF, SO2 were not found in any of the moxas. Conclusions: The amount of harmful gases emitted from burning moxa was much lower than short-term exposure standards of chemical and physical factors (Ministry of Labor 2010-44). Further experiments measuring gases from moxa combustion should be done in larger environments similar to normal medical clinics.

A case of venous stasis ulcer treated by subfascial endoscopic perforator ligation and split thickness skin graft (내시경적 교통정맥 결찰술과 부분층 피부이식술로 치료한 정맥성 궤양의 치험례)

  • Moon, Seong ho;Lee, Jong wook;Koh, Jang hyu;Seo, Dong kook;Choi, Jai koo;Jang, Young chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.336-340
    • /
    • 2009
  • Purpose: The wound of a patient who has chronic venous insufficiency is easy to recur. Also they develop a complication even after the conservative therapy or skin graft. We have to diagnose the venous stasis ulcer correctly and remove the cause to improve the effectiveness of treatment. We operated endoscopic perforating vein ligation and splitt thickness skin graft on a patient with venous stasis ulceration on right leg. Methods: A 26 year old male patient who had a scalding burn on his right leg in July 2005 checked into our hospital in March 2008. Even though he got three operations - the split thickness skin graft - at different clinics, the wound did not heal. The size of the wound was 12 by $8cm^2$ and granulation with edema and fibrosis had been formed. We kept observation on many collateral vessels and perforating vein through venogram and doppler sonography and firmly get to know that the wound came with chronic venous insufficiency. After a debridement and an application of VAC$^{(R)}$ for two weeks, the condition of granulation got better. So we proceeded with the operation using subfascial endoscopic perforating surgery and split thickness skin graft. Results: Through the venogram after the operation, we found out that the collateral vessels had been reduced compared to the previous condition and the widened perforating vein disappeared. During a follow up of 6 months, the patient did not develop recurrent stasis ulcer and postoperative complications. Conclusion: Subfascial endoscopic perforator ligation is relatively simple technique with a low complication rate and recurrence rate. Split thickness skin graft with subfascial endoscopic perforator surgery can be valuable method for treating severe venous stasis ulcers.

Cesium Release Behavior during the Thermal Treatment of High Bum-up Spent PWR Fuel (고연소도 경수로 사용후핵연료의 열처리에 따른 세슘 방출거동)

  • Park, Geun-Il;Cho, Kwang-Hun;Lee, Jung-Won;Park, Jang-Jin;Yang, Myung-Seung;Song, Kee-Chan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.53-64
    • /
    • 2007
  • The dynamic release behavior of Cs from high burn-up spent PWR fuel was experimentally performed under the conditions of a thermal treatment process such as voloxidation and sintering conditions. In voloxidation process, influence of the oxidation and reduction atmosphere on the Cs release characteristic using fragment type of spent fuel heated up to $1,500^{\circ}C$ was compared. In sintering process, temperature history effect on Cs release behavior was evaluated using green pellet under 4% $H_2/Ar$ environment. Temperature range for complete Cs release from spent fuel fragment under voloxidation condition was about $800^{\circ}C{\sim}1,200^{\circ}C$, but that of green pellet under the reduction atmosphere was $1,100^{\circ}C{\sim}1,400^{\circ}C$. Key parameters on Cs release behavior from spent fuel was powder formation as well as the diffusion rate of Cs compound to grain boundary and fuel surface.

  • PDF

Study of Combustion Characteristics with Variations of Combustion Parameter in Ultra-Lean LPG Direct Injection Engine (연소제어인자의 변화에 따른 직접분사식 초희박 LPG엔진의 연소특성 연구)

  • Park, Yun Seo;Park, Cheol Woong;Oh, Seung Mook;Kim, Tae Young;Choi, Young;Lee, Yong Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.607-614
    • /
    • 2013
  • Nowadays, automotive manufacturers have developed various technologies to improve fuel economy and reduce harmful emissions. The ultra-lean direct injection engine is a promising technology because it has the advantage of improving thermal efficiency through the deliberate control of fuel and ignition. This study aims to investigate the development of a spray-guided-type lean-burn LPG direct injection engine through the redesign of the combustion system. This engine uses a central-injection-type cylinder head in which the injector is installed adjacent to the spark plug. Fuel consumption and combustion stability were estimated depending on the ignition timing and injection timing at various air-fuel ratios. The optimal injection timing and ignition timing were based on the best fuel consumption and combustion stability.

A Study on the Dissolution and Separation for the Quantitative Analysis of Iodide in Spent Nuclear Fuel (사용후핵연료중의 미량 요오드 정량을 위한 용해 및 분리 연구)

  • Choi, Ke Chon;Lee, Chang Heon;Song, Byang Chol;Park, Yang Soon;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.751-758
    • /
    • 2000
  • A study was carried out on the dissolution of spent PWR fuels and performed on the fuels and the separation of iodide for the quantitative analysis using SIMFUEL which has chemical composition of a simulated spent PWR fuel (burn-up; 35,000 MWd/MTU and cooling time; 10 years). To dissolve the SIMFUEL effectively and to minimize the formation of volatile iodine through dissolution process, the optimum ratio of mixed acid ($HNO_3/HCl$ 80: 20 mol%) was established and ozone gas was purged. In the separation step of iodine with $CCl_4$, $NH_2OH{\cdot}HCl$ was used for reducing ${IO_3}^-$ to $I_2$.The optimum acidity of the dissolved solution and the added of $NH_2OH{\cdot}HCl$ were 2.5 M and more than $1.5{\times}10^{-3}mole$, respectively. The recovery of iodide by ion chromatography was $82.8{\pm}4.1%$ and the total yield was corrected by gamma spectrometery using $^{131}I$ as a tracer.

  • PDF

Percutaneous Radiofrequency ablation for the Treatment of Osteoid osteoma (유골골종의 경피적 고주파 열 치료)

  • Seo, Jai-Gon;Jung, Kwang-Hoon;Yang, Il-Soon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.3
    • /
    • pp.83-89
    • /
    • 2002
  • Purpose: To analyze the postoperative functional and radiographic follow-up results in patients who underwent percutaneous radiofrequency ablation therapy after the diagnosis of osteoid osteoma. Materials and Methods: Seven patients, who were clinically and radiographically diagnosed with osteoid osteoma from July 1999 to January 2001, and received percutaneous radiofrequency ablation therapy. The average follow-up period was 15.5 months(range, 8~25 months). For the diagnosis and accurate localization of the lesion, simple radiography, computed tomography and magnetic resonance imaging(MRI) were performed preoperatively. Simple radiographs and MRI were taken periodically for the follow-up studies. Results: In all 7 patients, symptoms completely disappeared within 3 days after the operation. The average period of hospitalization was 2.4 days, excluding 1 patient who needed an additional burn treatment. The average postoperative night and day pain scores were 1.8 and 1.3, respectively. The average vocational and recreational activity scores were 1 and 0.6, respectively. Conclusions: Satisfactory functional results were obtained with percutaneous radiofrequency ablation therapy for the elimination of osteoid osteoma. Compared to conventional treatment, the advantages of this therapy were short hospitalization period, no internal fixation and bone graft for preventing fracture, and no limitation of joint motion by long fixation period.

  • PDF

A Study on the Characteristics of Coffee Ground(CG)-RDF by Using Different Drying Method (건조법에 따른 커피박 고형연료의 특성 고찰 연구)

  • Kim, Sang-bin;Ha, Jin-wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.451-457
    • /
    • 2019
  • In this study, the characteristics of coffee grounds were reviewed by making them from solid fuel through heat-drying and oil-drying method. The differences in the higher calorific power by each dried sample were compared. And industrial analysis using the thermogravimetric analyzer was considered for applicability to organic waste and oily samples. Before and after drying, the surface of the specimen was observed with SEM equipment and the ingredients were measured through the EDS equipment. As a result, no other hazardous substances, such as heavy metals, were measured. Next, The differences between thermal decomposition and combustion reactions were considered through the TG and DTG curves. As a result, it is that the oil-dried coffee grounds is longer to burn than the heat-dried coffee grounds. Finally, the combustion gases emitted through the thermogravimetric analyzer were collected and the carbon monoxide and carbon dioxide performed qualitative and quantitative analysis using GC over time.

Effects on Indoor Air Quality of Burning Chemicals (Scented Candles and Incense Sticks) (태우는 생활화학제품(향초와 인센스 스틱)의 사용이 실내 공기질에 미치는 영향)

  • Eun-Ah Park;Seungyeon Eo;Yerin Oh;Na-Youn Park;Myoungho Lee;Younglim Kho
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.1
    • /
    • pp.36-42
    • /
    • 2024
  • Background: The use of scented candles and incense sticks, both of which are household products that are burned for indoor deodorization and calming effects, is increasing. Fine dust has been designated as a group 1 carcinogen by the International Agency for Research on Cancer. Volatile organic compounds (VOCs) affect air pollution and can cause diseases. Objectives: This study aims to determine the effect on indoor air quality by measuring PM2.5 and VOCs generated when burning scented candles and incense sticks. Methods: Scented candles and incense sticks were selected as household products to burn. As for the target sample, top-selling products (five types of scented candles, five types of incense sticks) were purchased online. The PM2.5 concentration according to time was measured immediately next to the sample and three meters away from each other in an enclosed space using a real-time aerosol photometer. VOCs were collected as samples under the same conditions using Tenax tubes and were quantitatively analyzed by TD-GC/MS. Results: In the case of scented candles, the concentration of PM2.5 did not increase during combustion and after being extinguished by placing a cover on the candle. For the incense sticks, the concentration of PM2.5 averaged 1,901.27 ㎍/m3. After burning scented candles and incense sticks, some VOCs concentrations were increased such as ethyl acetate and BTEX (benzene, toluene, ethylbenzene, xylene). Conclusions: Therefore, when using scented candles, extinguishment by placing a cover on the candle can be expected to reduce PM2.5. It is advisable to avoid using incense sticks because PM2.5 concentration increases from the start of combustion.

Numerical Investigation of Exhaust Gas Recirculation Effect under Boost Pressure Condition on Homogeneous Charge Compression Autoignition (HCCI엔진의 과급조건에서 EGR영향에 대한 수치해석적 연구)

  • Oh, Chung Hwan;Jamsran, Narankhuu;Lim, Ock Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.451-464
    • /
    • 2014
  • This study used numerical methods to investigates investigate the exhaust gas recirculation (EGR) effect under the condition of boost pressure condition on a homogeneous charge compression ignition (HCCI) combustion engine using numerical methods. The detailed chemical-kinetic mechanisms and thermodynamic parameters for n-heptane, iso-octane, and PRF50 from the Lawrence Livermore National Laboratory (LLNL) are were used for this study. The combustion phase affects the efficiency and power. To exclude these effects, this study decided to maintain a 50 burn point (CA50) at 5 CA after top dead center aTDC. The results showed that the EGR increased, but the low temperature heat release (LTHR), negative temperature coefficient (NTC), and high temperature heat release (HTHR) were weakened due by theto effect of the O2 reduction. The combined EGR and boost pressure enhanced the autoignition reactivity, Hhence, the LTHR, NTC, and HTHR were enhanced, and the heat-release rate was increased. also In addition, EGR decraeased the indicated mean effective pressure (IMEP), but the combined EGR and boost pressure increased the IMEP. As a results, combining the ed EGR and boost pressure was effective to at increase increasing the IMEP and maintaining the a low PRR.

Evaluation for Constructing Isochrones using a GIS (GIS를 이용한 등시간도 작성의 평가)

  • Cho, Hyo-Seob;Kim, Ke-Ho;Jung, Kwan-Sue;Kim, Jae-Han
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.925-936
    • /
    • 2003
  • The objective of this study is to suggest new drawing methods of isochrones using GIS. For this purpose the Unit Hydrograph (UH) of studied watershed for instantaneous rainfall suggested by Clark have been determined by routing the time-area curve through a single linear reservoir. To evaluate constructing methods of isochrones three methods has been examined; Channel Profile and Clark-kict method; Laurenson method; Average velocity method of S.C.S. Also, these methods have been recomposed by GIS in this study. To apply first method, spatial modeling, the vector based on the stream network and Route_System measuring a distance between points has been used. A raster based on the flow direction grid from burn DEM and the slope grid from original DEM has been applied for the second method. The third method has been applied by a raster based on the landuse grid and a velocity function expressed by slope. Results by these three methods have been evaluated with observed hydrograph, and the method using average velocity method of S.C.S shows more reasonable results comparatively.