• 제목/요약/키워드: Buried Type

검색결과 208건 처리시간 0.03초

반구형 축소모델을 이용한 접지전극 주변의 전위상승 분석 (Analysis of the Potential Rises near Grounding Electrodes using Semisplere type scale Model)

  • 이복희;백영환;이봉;김기복
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.259-262
    • /
    • 2008
  • This paper describes the ground surface potential profiles near the object to be grounded. The hemisphere water tank was used to simulate the. scale model. As a result, the ground surface potential near the ground electrode was considerably raised. In particular the ground surface potential at the just upper part of ground rod was higher than other part. The ground surface potential was lowered with increasing the buried depth of ground rod.

  • PDF

잠열 축열 - 바이오 세라믹 온돌의 난방 특성 - 이론적 분석을 중심으로 - (Floor Heating Characteristics of Latent Heat Storage - Bioceramic Ondol - Focused on Theoretical Analysis -)

  • 송현갑;유영선
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.213-222
    • /
    • 1995
  • Korean traditional Ondol with the sensible heat storage medium has been for a long time used as residential heating system, in these days the concrete Ondol without the heat storage medium was realized as the heating system in the private houses and the apartments. This floor heating system is good for our health. But the concrete Ondol is not desirable for the energy saving and for the maintenance of comfortable room temperature because the heat storage medium is not employed in the concrete Ondol. And as the hot water circulating pipes ate buried under the the concrete floor, the concrete Ondol system has some kind of problems to be improved. Therefore the new type of Ondol system was developed in this study. And the new Ondol was consisted of latent heat storage material as heat storage medium with a great heat capacity and bioceramics as medium to maintain comfortable room temperature. In this study, the heat transfer characteristics of latent heat storage-bioceramic Ondol was analyzed theoretically.

  • PDF

과부하 방지용 마이크로머시닝 금속 박막형 압력센서의 제작과 그 특성 (Fabrication of a Micromachined Metal Thin-film Type Pressure Sensor for High Overpressure Tolerance and Its Characteristics)

  • 김재민;임병권;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.192-196
    • /
    • 2002
  • This paper describes on the fabrication and characteristics of a metal thin-film pressure sensor based on Cr strain-gauges for harsh environment applications. The Cr thin-film strain-gauges are sputter-deposited onto a micromachined Si diaphragms with buried cavity for overpressure protectors. The proposed device takes advantages of the good mechanical properties of single-crystalline Si as diaphragms fabricated by SDB and electrochemical etch-stop technology, and in order to extend the operating temperature range, it incorporates relatively the high resistance, stability and gauge factor of Cr thin-films. The fabricated pressure sensor presents a low temperature coefficient of resistance, high-sensitivity, low non-linearity and excellent temperature stability. The sensitivity is 1.097~1.21 $mV/V{\cdot}kgf/cm^2$ in the temperature range of $25{\sim}200^{\circ}C$ and the maximum non-linearity is 0.43 %FS.

  • PDF

영구자석 내삽형 동기 발전기의 최적화 설계에 관한 연구 (A Study of Optimization Design for Buried type Permanent Magnet Synchronous Generator)

  • 이광호;권혁기;홍선기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.868-869
    • /
    • 2007
  • 자여자식 동기 발전기에 비해, 영구자석 내삽형 동기 발전기는 순간적인 부하 단락 시에도 지속적으로 여자기에 여자 전원을 공급할 수 있어 큰 부하 변동에도 안정적으로 발전기를 운전할 수 있게 해 준다. 본 연구에서는 이러한 전동기의 해석 프로그램을 개발하고, 이로부터 유전알고리즘을 이용하여 설계프로그램을 개발하였다. 영구자석동기 발전기의 목적함수를 효율로 두었으며, 발전기의 형상을 변화시켜 제약 조건을 만족하는 최대 효율을 갖는 1kW급 영구자석 내삽형 동기 발전기의 설계치를 제시하였다.

  • PDF

GSHP용 수직형 지중열교환기의 열전달 성능에 관한 연구 (A Study on Heat Transfer Performance of Vertical Ground Heat Exchanger of GSHP(Ground Source Heat Pump))

  • 정민호;장기창;나호상;백영진;박성룡;유성연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2102-2107
    • /
    • 2007
  • GSHP systems are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal and vertical type according to the installation method. Vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double u-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

지하매설 및 해양 금속구조물 음극방식용 모듈 타입 스위칭 정류기 (Module-Type Switching Rectifier for Cathodic Protection of Underground and Maritime Metallic Constructions)

  • 문상호;김보경;김인동;노의철;권영원;정성우;임헌호
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.570-578
    • /
    • 2002
  • 음극방식은 지하매설 및 해양 금속 구조물의 부식을 방지하기 위해 가장 많이 사용되고 있는 방식법이다. 기존의 음극방식용 정류기는 SCR 위상제어 정류기로 구성되어 입련단 역율이 낮으며, 부피와 무게가 큰 단점을 지니고 있다. 본 논문에서는 이러한 문제를 해결하기 위해 새로운 음극방식용 모듈타입 스위칭 정류기를 제안한다. 제안한 정류기 회로는 크게 두 부분, 즉 한 대로 구성된 AC/DC 컨버터부와 네 대로 구성된 Module Ttpe DC/DC 컨버터부로 되어 있다. AC/DC 컨버터는 IGBT PWM Rectifier로서 입력전압의 역률을 거의 1로 제어하고 있으며 또한 DC Link 전압을 일정하게 제어하고 있다. Module Type DC/DC 컨버터는 ZCS/ZVS 스위칭 동작을 통하여 스위칭 손실 감소와 함께 고주파 동작을 가능하게 하여, 입력측과 출력측의 전기적 절연을 위한 변압기로 고주파 변압기를 사용할 수 있게 하였다. 이로 인해 시스템의 부피와 무게를 현저히 감소시켰다. 본 논문에서 개발한 방식용 정류기 기술은 다른 유사 분야에의 적용도 가능할 것으로 기대된다.

절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가 (The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST))

  • 이장우;김점식;최충석
    • 한국안전학회지
    • /
    • 제31권6호
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.

퓨 방법을 통한 최적의 저장탱크 시공에 관한 연구 (A Study on the Optimized Installation of Gas Storage Tank through Pugh Method)

  • 허용정;이종락;이선영;임사환
    • 한국가스학회지
    • /
    • 제18권4호
    • /
    • pp.8-12
    • /
    • 2014
  • 본 연구는 가스충전소 등에서 운용하는 저장탱크에 대하여 퓨(Pugh) 방법을 통하여, 기존의 지상형과 지하형의 장점과 단점을 비교 판정하여 경제적 시공으로 고객만족을 실현시키기 위함이다. 특히 대규모 저장시설에서의 가스사고를 획기적으로 줄여 사회적으로 심각한 안전문제를 해결하고자 한다. 가스를 대량으로 취급 저장하는 시설에서 운용하는 저장탱크의 설치방법을 퓨 방법으로 판단하면 기존의 지상형과 지하매몰형, 지하격납형 중에서 안전성과 토지이용률이 우수한 형태는 지하격납저장탱크가 가장 효과적이다.

경주식 적석목곽묘의 구조복원 재고 (The Structual Restoration on Gyeongju-Style Piled Stone-Type Wooden Chamber Tombs)

  • 권용대
    • 헤리티지:역사와 과학
    • /
    • 제42권3호
    • /
    • pp.66-87
    • /
    • 2009
  • 적석목곽묘는 목곽 외부에 석재를 쌓거나 채운 다음 목개 위에 일정한 두께로 적석하고 점토로 밀봉한 구조이다. 경주 중심부라는 한정된 공간 속에 거의 모든 지배자가 지속적으로 한 묘제를 사용하였다는 점, 타 지역에서 확인되는 적석 형태와 전혀 다르다는 점 등에서 경주식 적석목곽묘로 정의하고자 한다. 적석목곽묘는 경주 중심부에서 5C 전반대부터 축조되기 시작한다. 평면형태, 목곽, 이중곽, 석재충전, 석단, 순장 등은 이전시기의 목곽묘에서 계보를 잇고 있다. 이외에 석축과 목주, 적석, 성토분구는 적석목곽묘의 출현과 함께 새롭게 나타나는 요소이다. 특히 석축과 목주는 황남대총을 비롯한 지상식 초대형분에서만 확인된다. 석축과 목주, 적석은 모두 성토 분구 축조과정 속에서 하나의 공정을 이루고 있다. 석축은 지상에 설치된 목곽의 외벽을 견고하게 유지시켜 주면서 성토 분구의 하중을 분산 수용한다. 목주는 석축의 붕괴를 방지하기 위한 보조장치로서 횡가목, 버팀목 등과 함께 사용되었다. 적석은 일정 크기의 석재를 갖고 일정한 두께로 목개 상부에 덮었다. 그리고 그 위에 점토로 밀봉한 다음 분구를 성토하였다. 적석은 경주지역의 입지적 특성이 반영된 것으로 파악된다. 경주 중심부의 적석목곽묘는 하천부지가 넓고 평탄한 형산강 동안을 따라 분포한다. 기반층은 대부분 모래와 냇돌로 구성되어 있다. 따라서 성토분구는 모래성분을 많이 함유하고 있다. 목개를 횡가한 다음 바로 성토할 경우 유수에 의한 붕괴 가능성 또한 크다. 고분의 외형을 유지하면서 내부구조물의 파괴를 방지하기 위하여 적석과 점토밀봉이 이루어진 것으로 판단된다. 상부의 봉토가 유실되더라도 하부의 적석은 형태를 어느 정도 유지할 것이기 때문이다. 성토분구는 국가 혹은 단위정치체가 성장단계에 진입하면서 나타나는 하나의 특징이다. 국가 출현단계 이후 성장단계에 진입하면서 사회구조에 변화가 나타나고 이와 맞물려 새롭게 출현한 지배등급에서 전대의 목곽묘와는 다른 적석목곽묘를 축조하기 시작한 것으로 판단된다. 이 과정에서 분구를 함께 성토한 것으로 파악되며, 지배등급의 성격에 따라 규모와 구조에서 차이를 보인다. 평면형태, 곽과 석단, 순장자의 수, 유물의 양과 질 등은 지배등급의 사회적 지위를 반영하고 있다. 따라서 적석목곽묘는 신라가 성장단계에 접어든 시점에 전대의 묘제로부터 분화 발전된 양상을 보이면서 나타난것으로 생각된다.

배수관 내시경 조사를 통한 간접적인 관 노후도 평가방법의 적정성 연구 (A Study on Adequacy of Pipe Deterioration Evaluation Methods using the Endoscope of Water Distribution Pipe)

  • 최태호;강신재;최재호;구자용
    • 상하수도학회지
    • /
    • 제26권5호
    • /
    • pp.669-683
    • /
    • 2012
  • The water supply pipes are buried across wide range of areas, so it is hard to spot them using excavation and takes a large amount of expense. Thus, there is a high risk for direct research and application, accompanying many difficulties in implementation of them. Therefore, it is more economical and convenient to use indirect evaluation variables than direct evaluation of the buried pipes in assessing the degree of pipe deterioration. To assess the degree of pipe deterioration using the indirect evaluation variables, it should be done first to identify how and to what extent they affect the degree of deterioration. This study measured the evaluation variables for pipe deterioration using the pipe endoscope and analyzed the measurement results and the degree of impact on the pipes. In addition, this study attempted to evaluate the adequateness of the pipe deterioration evaluation using the indirect variables based on the analysis results. The evaluation variables measured through the pipe endoscope were the thickness of sediments, size of scale, degree of desquamation and condition of connections. For the indirect evaluation variables, the data such as the property data from GIS pipe network map as well as the material, diameter, age and pipe lining material of the pipe, road type, leakage frequency, average water velocity and water pressure using the leakage repair records was collected. Using the collected data, this study comparatively analyzed the indirect evaluation variables for the degree of pipe deterioration and the results from the pipe endoscope to choose appropriate variables for pipe deterioration evaluation and calculated the weights of the indirect variables on the degree of deterioration. The results showed that the order of the impact of indirect variables on deterioration was pipe age > pipe lining material > road type > leakage frequency > average water velocity with their weights of 0.45, 0.20, 0.15, 0.10, and 0.10, respectively. Conclusively, the results suggest that the measures of sediment thickness, scale size, degree of desquamation and condition of connections are appropriate for the evaluation of pipe deterioration and sufficient for the analysis of the impact of the indirect variables on deterioration.