• Title/Summary/Keyword: Buried Type

Search Result 208, Processing Time 0.024 seconds

The Measurement of Concrete Deformations at Early Age using Fiber-Optic Bragg Grating Sensors (광섬유 GRATING SENSOR를 이용한 초기재령 콘크리트의 변형 측정)

  • 김지상;이상배;김남식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1238-1241
    • /
    • 2000
  • The deformations of concrete specimens were measured at early at early ages, in order to verify the applicability of FBG(Fiber Bragg Grating) sensors. The FBG sensors were directly buried at various locations in the beam-type RC specimens at the time of fabrication. In this experiment, the changes of strains in concrete at early age were successfully measured as the movement in wavelength of light signals. The FBG sensors may be a very effective tool to investigate the mechanical/thermal behavior inside of concrete structures.

  • PDF

Assistant Model For Considering Slot-Opening Effect on No-load Air-gap Flux Density Distribution in Interior-type Permanent Magnet Motor (매입형 영구자석 전동기에서 무부하시 공극 자속밀도 분포에 대한 Slot-Opening Effect를 고려한 보조 모델)

  • Fang, Liang;Kim, Do-Jin;Hong, Jung-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.759-765
    • /
    • 2011
  • This paper proposes an effective assistant model for considering the stator slot-opening effect on air gap flux density distribution in conventional interior-type permanent magnet (IPM) motor. Different from the conventional slot-opening effect analysis in surface-type PM (SPM) motor, a composite effect of slot-opening uniquely existing in IPM motor, which additionally causes enhancement of air gap flux density due to magnet flux path distortion in iron core between the buried PM and rotor surface. This phenomenon is represented by a proposed assistant model, which simply deals with this additional effect by modifying magnetic pole-arc using an effective method. The validity of this proposed analytical model is applied to predict the air gap flux density distribution in an IPM motor model and confirmed by finite element method (FEM).

Domestic Conditions on the Electrolytic Corrosion Protection of Buried Metallic Structures (지하매설 금속구조물의 전식방지 국내 현황)

  • Lee, Hyun-Goo;Ha, Tae-Hyun;Choi, Jeong-Hee;Jung, Ho-Sung;Bae, Jeong-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • With respect to a given structure, a stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit. Most often DC-powered traction systems like railroads and tramlines are responsible for large dynamic stray currents. This type of stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper investigates the domestic conditions on the electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems by survey.

  • PDF

Optimization and Efficiency Improvement of BCSC Solar Cells Using $MgF_{2}/CeO_{2}$Double Layer Antireflection Coatings ($MgF_{2}/CeO_{2}$ 이중반사방지막을 이용한 BCSC태양천지의 효율향상과 최적화)

  • 이욱재;임동건;이준신
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.251-254
    • /
    • 2001
  • This paper describes an efficiency improvement of buried contact solar cell (BSCS) with a structure of MgF$_2$/CeO$_2$/Ag/Cu/Ni grid/n$^{+}$ emitter/p-type Si base/p$^{+}$/Al. Theoretical and experimental investigations were performed on a double layer antireflection (DLAR) coating of MgF$_2$/CeO$_2$. We investigated CeO$_2$ films as an AR layer because they have a proper refractive index of 2.46 and demonstrate the same lattice constant as Si substrate. An optimized DLAR coating shewed a reflectance as low as 2.04 % in the wavelengths ranged from 0.4 ${\mu}{\textrm}{m}$ to 1.1 ${\mu}{\textrm}{m}$. BCSC cell efficiency was improved from 16.2 % without any AR coating to 19.9 % by employing DLAR coatings. Further details on MgF$_2$/CeO$_2$ DLAR coatings on the BCSC cells are presented in this paper.per.

  • PDF

High Efficiency Crystalline Silicon Solar Cells (고효율 단결정 실리콘 태양전지)

  • Kim, D.S.;Cho, E.C.;Cho, Y.H.;Ebong, A.U.;Min, Y.S.;Lee, S.H.
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.17-26
    • /
    • 1997
  • Since PESC(passivated emitter solar cell) was developed in 1985, high efficiency silicon solar cell technology based on planar technology has been improved in the order of PERC, Point Contact Solar Cell, PERL. BCSC and DSBC, which do not require photolithography, are expected to replace commercial screen printed cells because of its potential for low cost and high efficiency. In this paper, history and characteristics of each type of cells are reviewed.

  • PDF

Noise and Operating Properties of Si Vertical Hall Device (Si 종형 Hall 소자의 동작과 잡음 특성)

  • Ryu, Ji-Goo;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.10
    • /
    • pp.1890-1896
    • /
    • 2008
  • In this paper, the Si vertical Hall devices ale fabricated by using standard bipolar process and investigated in terms of the opeating and noise properties. The sensitivity of device with P+ isolation dam(type B) has been increased up to about 1.2 times compared to that device without the dam also noise has been increased. With the condition of f=I[KHz], band-width 1[Hz], the resolution of magnetic-field detection were about $0.97[{\mu}T]$/ type B and $1.25[{\mu}T]$/ type A, respectively, thus we must consider correlation the low noise or good resolution and high sensitivity in the situation for device geometry design or even for the materials.

A Study on Heat Transfer Performance of Horizontal Ground Heat Exchanger (수평형 지중열교환기의 열전달 성능에 관한 연구)

  • Chung Minho;Park Seongryong;Ra Hosang;Baik Youngjin;Yoon Hyungkee;Chang Kichang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.684-687
    • /
    • 2005
  • Ground source heat pump systems are used for heating, ventilating and air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. The solar heat and the rainwater are affected by the performance of heat exchanger and causes mutual influence among heat exchangers. In this study, to evaluate the performance of straight type, slinky type, and spiral type of horizontal ground heat exchangers designed on 1 RT scale, test sections are buried on the earth and experimental apparatus is installed. Therefore the performance of these is estimated.

  • PDF

Evaluation of the effect of cubic artificial reefs in Kyonggi Bay, west coast of Korea by using fish trap (통발 어구를 이용한 서해 경기만 사각형어초 시설의 효과 평가)

  • Yoo, Jae-Won;Lee, Man-Woo;Lee, Chang-Gun;Kim, Chang-Soo;Kim, Jung-Soo;Hong, Jae-Sang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.2
    • /
    • pp.126-139
    • /
    • 2007
  • In the autumn of 2000 and spring of 2001, field surveys were conducted to estimate the effectiveness of artificial reefs (type cube, $2{\times}2{\times}2m^3$) that were established in the four islands of Bangnyeong, Socheong, Daeyeonpyeong and Ganghwa in Kyonggi Bay, the west coast of Korea during 1995 and 1996. The condition of reefs was examined through SCUBA diving and a side-scan sonar. Much of the reefs in Daeyeonpyeong and Ganghwa area were buried in bottom sediment. Despite an intensive search in Bangnyeong area, even a cluster of reefs was not found and most of them seemed to be buried by sand waves. Thus an appropriate investigation on the sediment transport should be included in pre-assessment for the expected performance and protection of artificial reefs. Distribution of average CPUE in natural fishing ground (control) was estimated by bootstrapping simulation and possible comparison of CPUE between control and reef areas (treatment) were made in Bangnyeong and Socheong (Experiment I). Positive reef effect was detected in Socheong but CPUE of treatment in Bangnyeong was varied between or lower than the 99% CPUE confidence intervals of the control. Control/treatment abundance and biomass of fishes and invertebrates were tested by paired t-test and sign test (Experiment II). Only four cases among 22 showed significant positive effect. Based on the results, the cube artificial reef in Socheong was inferred as an affirmative one. Floor type was hypothesized to be one of the probable agents in determining the effectiveness of artificial reefs.

Present status of buried contact solar cell research in Samsung advanced institute of technology (SAIT) (SAIT에서의 전극함몰형 태양전지에 관한 최근 연구동향)

  • A.U. Ebong;S.H. Lee;D.S. Kim;Y.H. Cho;C.E. Cho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.3
    • /
    • pp.399-405
    • /
    • 1996
  • The present buried contact (BC) solar cell research at SAIT includes the development of a processing sequence suitable for production of the single sided (SS) BC solar cells. This paper presents some results for large area ($45cm^{2}$) SSBC cells fabricated on FZ and CZ silicon substrates. Cell efficiencies in excess of 18% fabricated on FZ, p-type, 0.5 ohm-cm, and over 16% on CZ p-type, 10~20 ohm-cm, wafers have been demonstrated. Both the FZ and CZ wafers were chemically textured. These results are preliminary and the exploration of double sided (DS) sequence, which is the future BC structure would lead to over 17% and 20% efficiency cells on CZ and FZ substrates respectively. The cost of solar cells can be reduced further if the many high temperature steps can be reduced to only one. This would be very advantageous to very poor quality substrates such as the CZ grown wafers.

  • PDF

A Study on Propulsion Performance of Underwater Ram-Jet with Optimized Nozzle Configuration (최적 노즐형상을 갖는 수중램제트의 추진성능에 관한 연구)

  • Kang, H.K.;Kim, Y.T.;Lee, Y.H.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.4
    • /
    • pp.42-52
    • /
    • 1997
  • The basic principle of underwater ram-jet as a unique marine propulsion concept showing vary high cruise speed range(e. g. 80-100 knots) is the thrust production by the transfer of the potential energy of compressed gas to the operating liquid through kinetic mixing process. This paper is aimed to investigate the propulsive efficiency of the nozzle flow in underwater ram-jet at the speed of 80 knots for the buried type vessel. The basic assumption of the theoretical analysis is that mixture of water and air can be treated as incompressible gas. For an optimized nozzle configuration obtained from the performance analysis, preliminary data for performance evaluation are obtained and effects of nozzle inner wall friction, ambient temperature, ambient pressure, water density, gas velocity, bubble radius, flow velocity, diffuser area ratio, mass flow ratio and water velocity gradient are investigated.

  • PDF