• 제목/요약/키워드: Bulk transfer method

검색결과 73건 처리시간 0.024초

다양한 지표면 위에서 총체 전달 방법에 의한 대기 난류 플럭스 추정 (Estimation of Atmospheric Turbulent Fluxes by the Bulk Transfer Method over Various Surface)

  • 김민성;권병혁;강동환
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1199-1211
    • /
    • 2014
  • The momentum flux and the sensible heat flux were measured with the scintillometers and ultrasonic anemometers at 6 sites of which surface characteristics like roughness length and zero-displacement are different each other. We estimated the momentum flux and the sensible heat flux based on the bulk transfer method with the drag coefficient and the heat transfer coefficient calculated from the temperature and wind speed at two heights. The variation of bulk transfer coefficients showed a remarkable difference depending on the atmospheric stability which is less influenced by the zero-displacement than the roughness length. The estimated sensible heat fluxes were in good agreement with those measured at 3 m, showing 23.7 $Wm^{-2}$ of the root mean square error that is less than 10% of its maximum. Since the estimated momentum flux is not only effected by drag coefficient but also by wind speed square, the determination of wind speed in the bulk transfer method is critical.

Prediction and improvement of the solid particles transfer rate for the bulk handing system design of offshore drilling vessels

  • Ryu, Mincheol;Jeon, Dong Soo;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권6호
    • /
    • pp.964-978
    • /
    • 2015
  • Numerous experiments with a scaled pilot facility were carried out to compare the relative bulk transfer performance of three special devices for applications to drilling systems. The pipe diameter for bulk transportation was 3 in., which corresponds to around half of the actual system dimensions. Two different pressures, 3 and 4 bar, were considered to check the relative performance under different pressure conditions at a bulk storage tank. And to make a practical estimation method of the bulk transfer rate at the early design stages of the bulk handling system, a series of experiments were conducted for real scaled bulk handing systems of two drilling vessels. The pressure drops at each pipe element as well as the bulk transfer rates were measured under different operating conditions. Using the measured results, the friction factor for each pipe element was calculated and a procedure for transfer rate estimation was developed. Compared to the measured transfer rate results for other drilling vessels, the estimated transfer rates were within a maximum 15% error bound.

Immunity Test for Semiconductor Integrated Circuits Considering Power Transfer Efficiency of the Bulk Current Injection Method

  • Kim, NaHyun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권2호
    • /
    • pp.202-211
    • /
    • 2014
  • The bulk current injection (BCI) and direct power injection (DPI) method have been established as the standards for the electromagnetic susceptibility (EMS) test. Because the BCI test uses a probe to inject magnetically coupled electromagnetic (EM) noise, there is a significant difference between the power supplied by the radio frequency (RF) generator and that transferred to the integrated circuit (IC). Thus, the immunity estimated by the forward power cannot show the susceptibility of the IC itself. This paper derives the real injected power at the failure point of the IC using the power transfer efficiency of the BCI method. We propose and mathematically derive the power transfer efficiency based on equivalent circuit models representing the BCI test setup. The BCI test is performed on I/O buffers with and without decoupling capacitors, and their immunities are evaluated based on the traditional forward power and the real injected power proposed in this work. The real injected power shows the actual noise power level that the IC can tolerate. Using the real injected power as an indicator for the EMS test, we show that the on-chip decoupling capacitor enhances the EM noise immunity.

벌크화물의 철도역 환적저항 요인과 정책 방향 연구 (Transfer Resistance Factors and Policy Directions in Railway Stations of Bulk Freight)

  • 최창호
    • 한국철도학회논문집
    • /
    • 제18권6호
    • /
    • pp.596-608
    • /
    • 2015
  • 지구온난화에 대한 대응으로 철도를 이용한 화물운송의 필요성이 강조되고 있다. 이의 일환으로 본 연구는 벌크화물을 대상으로 철도역 환적저항 감소를 통한 철도이용 활성화 방안을 강구하였다. 우선 화주가 철도운송을 선택하는 과정에서 중요하게 고려하는 환적관련 요인을 파악하였다. 그리고 이들의 상대적 중요도를 비교하고 환적단계에서 영향을 미치는 비중을 평가하였다. 다음으로 환적저항 요인에 대한 분석을 토대로 철도역에서 환적저항을 감소시킬 정책추진 방향을 제안하였다. 정책은 하드웨어적 개선방안과 소프트웨어적 개선방안을 포함한다. 또한 정책 추진을 통해 이끌어내야 할 환적비용과 환적시간의 감소 범위도 제시하였다.

BULK선용 자동 Ballast Water Management Plan 개발 (The development of auto Ballast Water Management Plan For Bulk Carrier.)

  • 홍충유;권영섭;권성진;황진욱;박제웅
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.266-271
    • /
    • 2003
  • Many port states such as New Zealand. the USA. Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organism and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason. they perceived that the ballast exchange in deep sea is the most effective method. together with submitting the ballast management plan which contains the effective exchange method. ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that. it provide more convenient and stable process to prepare ballast water management plan for Bulk Carrier.

  • PDF

수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델 (A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

파라핀 슬러리의 생성 및 관내 대류열전달에 관한 연구 (Formation of a paraffin slurry and its convective heat transfer in a circular pipe)

  • 최은수
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.50-60
    • /
    • 1998
  • As a method to develop an enhanced heat transfer fluid, the fine particles of a phase-change material were mixed with a conventional heat transfer fluid. Paraffin, which can be obtained easily in domestic market, was used for the phase-change material and water was used as a carrier fluid. Fine liquid particles of paraffin were formed in water as an emulsion by using an emulsifier, and they were cooled rapidly to become solid particle, resulting in paraffin slurry. The average diameter of produced solid particles was inversely proportional to the amount of the added emulsifier, which was theoretically proved. The produced paraffin slurry was tested thermally in heat transfer test section having a constant-heat-flux boundary condition. The test section was made of a circular stainless-steel pipe, which was directly heated by the power supply having a maximum of 50 Volts-500 Amperes. DSC(Differential scanning calorimeter) tests showed that two kinds of phase change were involved in the melting of paraffin, and it was explained in two different ways. A five- region-melting model was developed by extending the conventional three-region-melting model, and was used to obtain the local bulk mean temperatures of paraffin slurry in the heating test section. The local heat transfer coefficient showed a maximum where the bulk mean temperature of the paraffin slurry reached at the melting temperature of paraffin.

세라믹 소재의 흡음성능에 관한 실험적 연구 (An Experimental Study on the Absorption Performance of Ceramic Materials)

  • 송화영;서은성;김형태;이성민;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.163-167
    • /
    • 2009
  • In this study, the acoustic properties of ceramic sound absorbing materials with different thickness and bulk density were investigated in terms of characteristic impedance, propagation constant, and absorption coefficient. The well-known two-cavity method was used for evaluating those acoustic parameter values. Also, in order to validate the experimentally measured values, the results were compared with the results obtained from Chung and Blaser's transfer function method and SWR method. The experimentally measured values of normal absorption coefficients were generally agreed well with the corresponding values from the transfer function method and the SWR method. Based on the experimental results, the following conclusions could be made. The magnitude of the absorption coefficient and the frequency range of the maximum absorption coefficient were controllable by changing the thickness and bulk density of the sound absorbing materials.

  • PDF

금속와이어 흡음재의 음향특성 (Acoustical Properties of Steel-Wire Sound Absorbing Materials)

  • 이승;박상준;이동훈;배재근;김민배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1341-1346
    • /
    • 2001
  • In this study, the acoustic properties of steel-wire sound absorbing materials with different thickness and bulk density were investigated in terms of characteristic impedance, propagation constant, and absorption coefficient. The well-known two-cavity method was used for evaluating those acoustic parameter values in experiments. Also, in order to validate the experimentally measured values, the results were compared with the results obtained from Chung and Blaser's transfer function method and SWR method. The experimentally measured values of normal absorption coefficients were generally agreed well with the corresponding values from the transfer function method and the SWR method. Based on the experimental results, the following conclusions could be made. The magnitude of the absorption coefficient and the frequency range of the maximum absorption coefficient were controllable by changing the thickness and bulk density of the sound absorbing materials. Also, the magnitude of the absorption coefficient depended on the characteristic impedance and the propagation constant. As large as the air cavity depth at the rear side of the steel-wire sound absorbing materials, the maximum magnitude of the absorption coefficient occurred at the lower frequency ranges.

  • PDF

MONTE CARLO METHOD EXTENDED TO HEAT TRANSFER PROBLEMS WITH NON-CONSTANT TEMPERATURE AND CONVECTION BOUNDARY CONDITIONS

  • Cho, Bum-Hee;Cho, Nam-Zin
    • Nuclear Engineering and Technology
    • /
    • 제42권1호
    • /
    • pp.65-72
    • /
    • 2010
  • The Monte Carlo method for solving heat conduction problems [1-3] is extended for non-constant temperature boundary conditions in this study. The new method can treat problems with any given non-constant boundary temperatures, including heat convection problems with non-constant fluid bulk temperature. A set of problems, particularly the heat transfer problem in a pebble fuel, is analyzed by this new method. In addition, a new method to reduce the statistical errors in kernel fuel regions is introduced when the Monte Carlo method is applied to a pebble fuel.