• Title/Summary/Keyword: Bulb

Search Result 841, Processing Time 0.023 seconds

The fabrication of Pt electroplating on ITO multi-electrode array in neuronal signal detection (전극의 임피던스 감소를 위해 백금 도금한 ITO 신경신호 검출용 다중 전극 제작)

  • Kwon, Gwang-Min;Choi, Joon-Ho;Lee, Kyoung-J.;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.257-259
    • /
    • 2002
  • In investigating the characteristics of a neural network, the use of planar microelectrode array shows several advantages over normal intracellular recording[1]. A transparent indium tin oxide(ITO) multi-electrode array(MEA) was fabricated and its top surface was insulated with photodefinable polyimide(HD-8001) except the exposed area for interfacing between the ITO electrodes and the neuronal cells. The exposed ITO electrodes were platinized in order to reduce the impedance between the electrodes and electrolyte. The one-minute platinization with $0.99nA/{\mu}m^2$ current density reduced the average impedance of the electrodes from $2.5M\Omega\;to\;90k\Omega$ at 1kHz in normal ringer solution. Cardiac cells were cultured on this MEA as a pilot study before neuron culture. The signals detected by the platinized electrodes had larger amplitudes and improved signal to noise ratio(SNR) compared to non-platinized electrodes. It is clear that microelectrodes need to have lower impedance to make reliable extracellular recordings, and thus platinization is essential part of MEA fabrication. Burst spike of cultured olfactory bulb was also detected with the MEA having platinized electrodes.

  • PDF

Antimycotic Activity of Allium Sativum Against Beauveria Bassiana, Pathogenic Fungus of White Muscardine Disease in Silkworm, Bombyx mori L. (Lepidoptera: Bombycidae)

  • Mohanan, N. Madana;Guptal, S.K.;Mitra, P.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.14 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • White Muscardine is the most common fungal disease of silkworm, Bombyx mori L. caused by the pathogenic fungus, Beauveria bassiana (Balsamo) Vuillemin. In the present investigation, an attempt has been made to screen locally available medicinal/ weed plants against Beauveria bassiana. Among the plant extracts (PE) tested, 5% aqueous crude extract of the bulb of Allium sativum (Garlic) has been found to be most effective against Beauveria bassiana. The radial growth of Beauveria bassiana in vitro was inhibited to the tune of 54.9% in aqueous extract and 54.4% in ethanolic extract of Allium sativum and correspondingly mycelial dry weight gave rise to 110.7 mg and 108.7 mg against 201.7 mg in control 15 days post treatment. Similarly, silkworm larvae topically inoculated with the Beauveria bassiana conidia ($1.8{\times}10^6/ml$) registered survival up to 53.0% against 0.0% in control after treatment with aqueous extract of Allium sativum. Simultaneously, as a preventive measure, silkworm larvae were put to rear in conidia contaminated seat paper instantly treated with aqueous extract of Allium sativum that also increased survival up to 61.0% against 4.6% in control. It is also observed that the plant extract is absolutely innocuous to silkworm.

A Study on Prediction of Temperature and Humidity for Estimation of Cooling Load (냉방부하 추정을 위한 온도와 습도 예측에 관한 연구)

  • Yoo, Seong-Yeon;Lee, Je-Myo;Han, Kyou-Hyun;Han, Seung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.394-402
    • /
    • 2007
  • To estimate the cooling load for the following day, outdoor temperature and humidity are needed in hourly base. But the meteorological administration forecasts only maximum and minimum temperature. New methodology is proposed for predicting hourly outdoor temperature and humidity by using the forecasted maximum and minimum temperature. The correlations for normalized outdoor temperature and specific humidity has been derived from the weather data for five years from 2001 to 2005 at Seoul, Daejeon and Pusan. The correlations for normalized temperature are independent of date, while the correlations for specific humidity are linearly dependent on date. The predicted results show fairly good agreement with the measured data. The prediction program is also developed for hourly outdoor dry bulb temperature, specific humidity, dew point, relative humidity, enthalpy and specific volume.

A Study on the Performance Prediction of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능예측에 관한 연구)

  • Yoon, Seong-Yeon;Kim, Jin-Hyuck;Chung, Min-Ho;Jie, Myoung-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.372-380
    • /
    • 2008
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. Paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air. The purpose of this research is to obtain the experimental correlations for the friction factor, heat transfer coefficient, mass transfer coefficient and permeance of paper heat exchanger, which can be used to predict the performance of the paper heat exchanger. Pressure drops at various velocities, and sensible and latent heat transfer rates at various dry-bulb temperatures, relative humidities and specific humidities are measured to derive experimental correlations. The results of prediction using correlations show fairly good agreement with the experimental data obtained in the actual operating conditions.

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler (재생증발식 수냉각기의 냉각성능 해석)

  • Choi Bong-Su;Hong Hi-Ki;Lee Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.

Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change (기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구)

  • Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.27 no.12
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

Investigation of Operation and Improvement for Heat Watch Warning System to Provide Health-Weather Information (보건기상정보 제공을 위한 폭염특보 운영현황 및 개선방안 조사)

  • Hwang, Mi-Kyoung;Kang, Yoon-Hee;Kim, Sungmin;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.277-285
    • /
    • 2019
  • Heat watch warning systems are operating in Korea and several other countries (China, the United Kingdom, France, the United States, Germany, Australia, and Japan). The heat wave indices used in this system are the heat index, perceived temperature, the wet bulb globe temperature, and the daily maximum temperature. To improve the heat wave advisory and warning system, some suggestions have been made. The meteorological-health index (i.e., indirect index), has especially been proposed in previous studies. This information should be provided not only to vulnerable groups (seniors, infants, and children), but also to outdoor workers who may be particularly exposed to heat waves. In addition, to have sufficient preemptive response times, the need for an extension of the heat watch warning period was suggested. Finally, the subdivision of administrative units and risk stages was proposed.

A Case Series of Ingested Open Safety Pin Removal Using a Proposed Endoscopic Removal Technique Algorithm

  • Demiroren, Kaan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.5
    • /
    • pp.441-446
    • /
    • 2019
  • Purpose: Safety pin ingestion is common in some regions of the world and may lead to severe morbidity and mortality. The aim of this study was to present some practical suggestions for ingested safety pins using an accompanying algorithm, presented for the first time in the literature to the best of our knowledge. Methods: Twenty children with ingested safety pins during a 4-year period were retrospectively included in the study. Results: Median age of patients was 9.5 months (interquartile range, 6.3-14 months), and 70% were girls. On endoscopic examination, safety pins were observed in the stomach (25%), duodenal bulb (20%), upper esophagus (15%), middle esophagus (10%), and second part of the duodenum (10%) but were not observed in 20% of the cases. Safety pins were removed using endoscopy in 15 cases (75%). In four cases (20%), no safety pin was observed on endoscopic examination. In one case (5%) involving a 6-month-old infant, the safety pin could not be removed although it was observed using endoscopy. No surgical intervention was needed for any patient. No complications such as perforation or deaths developed, except for erosions, due to the foreign body removal procedure. Conclusion: Safety pins are easily removed endoscopically. The best option is to remove the safety pin using endoscopy while it is still in the esophagus and stomach. For this reason, endoscopic procedures should be performed as soon as possible in children who have ingested safety pins.

Basic study on a garlic (Alliumsativum L.) upright planter

  • Lee, Sang Yoon;Park, Hyo Je;Kweon, Gi Young
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.2
    • /
    • pp.341-350
    • /
    • 2019
  • Garlic is one of the most popular seasoning bulb vegetables in Korea and is the most commonly used food ingredient. However, the cultivation areas are decreasing every year as the price drops due to imported garlic, and labor is insufficient to produce garlic by conventional methods. Cultivation requires various tasks until garlic is harvested. Seeding is one of the important and laborious tasks; thus, mechanization is necessary. When seeding garlic, the sprout should face upwards; otherwise, it may rot or produce poor quality garlic. This study investigated the extent of growth of northern- and southern-type garlic in eight different positions. The results show when the roots were not planted properly, the stems were weak, and the garlic bulbs were small. A simple garlic planter was manufactured with a crank-press mechanism to plant garlic in an upright position. Using this machine, a three-fold experiment was carried out with 100 strips of garlic. The test results showed that 99.4% of the planted garlic strips were positioned upright or close to being upright, and 0.6% failed to take root. An image processing algorithm was developed to locate the root part of the garlic, and the result showed a success rate of 81%. A future study will develop an automatic garlic upright planting system with a viewing system.