• 제목/요약/키워드: Building uses

검색결과 766건 처리시간 0.032초

서울시 대가구 주거지역의 상업화·업무화와 상업지역의 주거화 현상의 고찰 (An Investigation of the Building-use Changes of Residential and Commercial Areas in the Land-used Superblocks in Seoul)

  • 전진부;양우현
    • 한국주거학회논문집
    • /
    • 제26권6호
    • /
    • pp.127-137
    • /
    • 2015
  • This investigation is to question as to whether and how much urban residential superblocks have changed the uses of facilities, as compared with original zoning plan. The difference between the original plan for 'land use' in 1960's and current 'building uses' has been examined on six superblocks in Seoul, and the reasons for change were analyzed. Investigation results are as follows: As the original urban planning was intended for use-purification by the subdivision of zones in a superblock through zoning, current buildings uses are different from the land-use. Commercial facilities are located in residential zone along community paths because of the necessity, and business buildings are placed on the appropriate-sized lots in the middle of residential blocks, due to the need of small and low-rent offices. Also, different types of residence have been built on convenient locations in commercial zone to meet various housing needs. In conclusion, the current zoning system plays a role of controling the volume of buildings rather than the use of land. Therefore, mixed use of land, not functional separation, becomes a natural phenomenon taken place in the contemporary cities, and it is high time to adopt a mixed-use zoning system.

연안도시의 열 수요 추정 및 GIS Map 작성에 관한 연구 (Study on Evaluation of Heat Demand and GIS Mapping in Costal Area)

  • 정용현
    • 수산해양교육연구
    • /
    • 제25권1호
    • /
    • pp.192-197
    • /
    • 2013
  • To overcome the mismatch of heat demand and heat supply is important as considering point on heat utilizing aspects in Urban area. At this point, It need to know the plan of heat networks on the heat balance aspects. The purpose of this study is to know the method of heat evaluation on heat network around costal area. It is need to building uses to calculate the amounts of heat demand. 25 different types of building uses were supplied, but it was reclassified 10 types and calculated the amounts of heat demand in the costal area. The results was described on the area with GIS mapping.

Seismic fragility analysis of base isolation reinforced concrete structure building considering performance - a case study for Indonesia

  • Faiz Sulthan;Matsutaro Seki
    • Structural Monitoring and Maintenance
    • /
    • 제10권3호
    • /
    • pp.243-260
    • /
    • 2023
  • Indonesia has had seismic codes for earthquake-resistant structures designs since 1970 and has been updated five times to the latest in 2019. In updating the Indonesian seismic codes, seismic hazard maps for design also update, and there are changes to the Peak Ground Acceleration (PGA). Indonesian seismic design uses the concept of building performance levels consisting of Immediate occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Related to this performance level, cases still found that buildings were damaged more than their performance targets after the earthquake. Based on the above issues, this study aims to analyze the performance of base isolation design on existing target buildings and analyze the seismic fragility for a case study in Indonesia. The target building is a prototype design 8-story medium-rise residential building using the reinforced concrete moment frame structure. Seismic fragility analysis uses Incremental Dynamic Analysis (IDA) with Nonlinear Time History Analysis (NLTHA) and eleven selected ground motions based on soil classification, magnitude, fault distance, and earthquake source mechanism. The comparison result of IDA shows a trend of significant performance improvement, with the same performance level target and risk category, the base isolation structure can be used at 1.46-3.20 times higher PGA than the fixed base structure. Then the fragility analysis results show that the fixed base structure has a safety margin of 30% and a base isolation structure of 62.5% from the PGA design. This result is useful for assessing existing buildings or considering a new building's performance.

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • 제21권1호
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

비틀림비정형을 갖는 건물의 비선형 시간이력해석 (Non-linear time history analysis of building with torsional irregularity)

  • 이한선;고동우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.219-222
    • /
    • 2005
  • Many RC building structures of multiple uses constructed in Korea have the irregularities of torsion and soft story at bottom stories. A typical irregular building was selected as prototype and shaking table tests were performed to investigate the seismic performance of this building. The objective of this study is to evaluate the correlation between the experimental and analytical responses of this irregular building structure subjected to the earthquake excitation by using OpenSees(Open System for Earthquake Engineering Simulation). The results of analyses simulate well the behavior of the building having torsional irregularity and weak stories.

  • PDF

Surface Finishability of Concrete According to Degree of Damage and the Number of Uses of the Aluminum Form

  • Noh, Sang-Kyun;Lee, Seung-Hoon;Han, Cheon-Goo
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.522-529
    • /
    • 2013
  • As concrete forms, panel forms made of plywood used to be widely used, but recently a system form made of aluminum has been broadly adopted because of the advantages it offers in terms of constructability and economy. However, an aluminum form reacts with concrete, which is alkali, and creates hydrogen gas. As a result, air pockets occur on the concrete's surface, and its finishability deteriorates. Therefore, this research analyzed the relationship between the distribution of voids and surface roughness and the damage degree and number of uses of the aluminum form. The analysis of the distribution of voids shows that the number of voids of 0.1~1 mm, which are considered to have occurred because of chemical reaction, was 200~500 on the coating plywood, but was 1 500~2 000 on the aluminum form after 3 uses, and impossible to count after a higher number of uses. Surface roughness was $1.7{\sim}3.2{\mu}m$ on the coating plywood form, but was about $2.6{\mu}m$ after the first use and about $6.8{\mu}m$ after 10 uses, a 2.6-fold increase. Distribution of voids did not show a particular tendency depending upon the degree of damage to the concrete form, but surface roughness showed an increasing tendency as the degree of damage grows. Therefore, when using aluminum forms, surface maintenance should be carried out completely, such as prevention of damages to the form surface coating materials and spreading of separating materials on forms.

Analysis of building frames with viscoelastic dampers under base excitation

  • Shukla, A.K.;Datta, T.K.
    • Structural Engineering and Mechanics
    • /
    • 제11권1호
    • /
    • pp.71-87
    • /
    • 2001
  • A frequency domain response analysis is presented for building frames passively controlled by viscoelastic dampers, under harmonic ground excitation. Three different models are used to represent the linear dynamic force-deformation characteristics of viscoelastic dampers namely, Kelvin model, Linear hysteretic model and Maxwell model. The frequency domain solution is obtained by (i) an iterative pseudo-force method, which uses undamped mode shapes and frequencies of the system, (ii) an approximate modal strain energy method, which uses an equivalent modal damping of the system in each mode of vibration, and (iii) an exact method which uses complex frequency response function of the system. The responses obtained by three different methods are compared for different combinations of viscoelastic dampers giving rise to both classically and non-classically damped cases. In addition, the effect of the modelling of viscoelastic dampers on the response is investigated for a certain frequency range of interest. The results of the study are useful in appropriate modelling of viscoelastic dampers and in understanding the implication of using modal analysis procedure for building frames which are passively controlled by viscoelastic dampers against base excitation.

1인 가구 거주자의 생활패턴이 고려된 에너지소요량 유형 분석 (An Analysis of Energy Consumption Types Considering Life Patterns of Single-person Households)

  • 이승희;정성원;임기택
    • 대한건축학회논문집:계획계
    • /
    • 제35권1호
    • /
    • pp.37-46
    • /
    • 2019
  • The energy of the building is influenced by the user 's activity due to the population, society, and economic characteristics of the building user. In order to obtain accurate energy information, the difference in the amount of energy consumption by the activities and characteristics of building users should be identified. The purpose of the study is to identify the difference in the amount of energy consumption by the user's activities in the same building, and to analyse the relationship between user's activities and demographic, social and economic characteristics. For research, energy simulation is performed based on actual user activity schedule. The results of the simulation were clustered by using K-Means clustering, a machine learning technique. As a result, four types of users were derived based on the amount of energy consumption. The more energy used in a cluster, the lower the user's income level and older. The longer a user's indoor activity times, the higher the energy use, and these activities relate to the user's characteristics. There is more than twice the difference between the group that uses the least energy consumption and the group that uses the most energy consumption.

WBS-CBS통합정보의 실적수량에 의한 기성 및 진도관리에 관한 연구 (Existing and progress control research of Existing quantity the integrated information Uses WBS-CBS.)

  • 안재홍;이영도
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.261-264
    • /
    • 2009
  • Construction projects are managed by focusing on the results of projects. Moreover, cost and schedule are managed separately even though the efficiency of integrated management is very high. This paper proposes existing and progress control research of existing quantity the integrated information uses WBS-CBS. Schedule and cost are most important in construction projects. Specially, progress and cost are relationship of the managing integrated in many construction management. The quantity of materials for the works of construction is the base to create activities and a network. The quantity of materials of materials for the elemens of a building is a base of cost estimation and resource. allocation. This study suggest method for relating the schedule and cost information through the case study of construction field engineers.

  • PDF

서울시 지하수 수질특성에 관한 연구 (The characteristics of the Groundwater Quality in Seoul)

  • 김익수;엄석원;이재영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.225-228
    • /
    • 2003
  • For the purpose of finding out the distributions of groundwater uses, the effect of facilities on the parameter and the correlations among measurements, various statistical analysis were carried out with the data of groundwater quality measurements from January to December in 2002. 1. The rates of groundwater for drinking water were 10.5% in Yangcheon-Gu, 10.2% in Kangdong-Gu, and 9.9% in Eunpyung-Gu. The rates of other uses of groundwater were shown to be 58.1%(786 wells) for civil defense emergency, 22.1%(299 wells) for contamination-concerning, 9.8%(133 wells) for water quality monitoring, consisting of 90% of all groundwater. 2. The 52.6% of groundwater for drinking were demonstrated to be appropriate while 91.9% for tither uses-domestic, industrial, agricultural uses- were shown to be proper. 3. For drinking water, the average values of colar, turbidity, NH3-N, F, and Fe were 11.216 degree, 2.138 NTU, 2.458mg/l, 0.212mg/1 and 0.507mg/1 respectively. 4. In cases of drinking water wells for emergency, the results of statistical analysis showed that building year of the wells, depth and pumping rate didn't affect on whether it was proper for that use or not. It were shown that there were linear correlations between depth and NO$_3$-N(-0.171) and F ̄(0.332) while the correlation coefficients were 0.381 and -0.169 between the building year of well and depth and pumping rate respectively.

  • PDF