• Title/Summary/Keyword: Building structure

Search Result 4,844, Processing Time 0.026 seconds

Quantification for Collapsion Probability of Building Structures( I ) (건축구조물 붕괴위험도 정량화에 관한 연구( I ))

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.110-120
    • /
    • 1994
  • The Quantitative analysis for collapsion probability of each construcion work has not been developed, despite of that the one for safety management itself has been reported, up to now. It is concluded that showing critical check points against structure collapsion due to each work at construction site, and Quantifying those could be useful Quality-assuring tool, not to prevent Quality failure. Risk classes of each work at construction site, classified by German Builders Mutual-Aid Association (GEBMAS), and by special instruction rates of Korea Insurance Development Institute, are introduced to compare with the results of this study. As of a study method, total 2,002 sheets of questionwares are distributed directly to new city development areas, which are called, Ilsan 110 points : Pundang 79points and Chungdong 38points, including additional Changwon 125sheets and pusan 60sheets, by four(4) people, for contact with actual site engineers. Total responses of 1,056 sheets, are collected. Interrelationship diagram between experience years of Engrs., and risk rate of responses are also classified, with the criteria of four(4) years. Domestic journals with relation to construction have reported that main building Structure collapsions are mainly shown on apartment buildings and office ones. These two(2) building structures are again classified as five(5) kinds of works. This study takes use of an approach on haying the risk rates for each construction work on the above individual construction work. Additionally, site investigations have been performed to find out any possible unreasonable check items, due to construction method ; Reinforced Concret structure, Pre cast Concrete structure, and Steel structure building. Developed Quality Assurance Analysis Form with the Quantitative danger class, resulted from this study, are verified as it is able to be a good efficiency tool against collapsion of building structures.

  • PDF

Damage Detection of Shear Building Structures Using Dynamic Response (동적응답신호를 이용한 전단형 건물의 손상추정)

  • Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.101-107
    • /
    • 2014
  • Damage location and extent of structure could be detected by the inverse analysis on dynamic response properties such as frequencies and mode shapes. The dynamic response of building structures has many noise and affected by nonstructural members and, above all, the behavior of building structure is more complex than civil structure and this makes the damage detection difficult. In recent researches the damage is detected by the indirect index such as sensitivity or assumed values. However, for the more reasonable damage detection, it needs to use the damage index directly induced from dynamic equation. The purpose of this study is to provide the damage detection method on shear building structures by the damage index directly induced from dynamic equation. The provided damage index could be estimated from measured mode shape of undamaged structure and frequency difference between undamaged and damaged structure. The damage detection method is applied to numerical analysis model such as MATLAB and MIDAS GENw for the verification. The damage index at damaged story represents (-) sign and 15 times than other undamaged sories.

A Study on the Application of EQS bearings for the Seismic Isolation of Building Structures by ICT Case study (ICT센터 사례 연구를 통한 EQS의 건축 구조물 면진에의 적용 연구)

  • Yu, Seong-Mun;Lee, You-In;Ji, Yong-Soo;Choi, Dae-Sung;Kim, Doo-Kie
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2013
  • An application of the EQS (Eradi Quake System) bearings to a short period building structure and the structure earthquake responses according to the design parameters of the EQS are studied by the ICT Center case study. The features of the EQS application to seismic isolated building structures are investigated, and the design procedure to determine the yield load and the secondary stiffness of the EQS is also studied. A computational analysis is performed to confirm the applicability of the EQS to the building structure and the earthquake responses according to the design parameters. The ICT Center in Indonesia is adopted as an application case of the EQS. The application of the EQS is found to extend the fundamental period of the ICT Center. Three types of EQS with different yield loads and secondary stiffness are designed and applied in the earthquake response analyses. The analysis results show the response of the structure with respect to the design parameters and which type of EQS is suitable for the ICT Center.

Performance Evaluation of a Large-scale MR Damper for Controlling Seismic Responses Using a Real-time Hybrid Test Method (실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 제진 성능평가)

  • Park, Eun-Churn;Lee, Sung-Kyung;Youn, Kyung-Jo;Chung, Hee-San;Lee, Heon-Jae;Choi, Kang-Min;Moon, Suk-Jun;Jung, Hyung-Jo;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.131-138
    • /
    • 2008
  • This paper presents real-time hybrid test method of large-scale MR damper applied to a building structure under seismic excitation. The real-time hybrid test using an actuator for the control performance evaluation of a MR damper controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a large-scale MR damper adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a MR damper and building structure is measured from the load cell attached on the actuator system and is fed-back to the computer to control the motion of the actuator. Then, the actuator is so driven that the error between the interface displacement computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the actuator. The control efficiency of the MR damper used in this paper is experimentally confirmed by implementing this process of experiment on real-time.

Structure and Change Pattern of Gijang Mountain Fortress and its Receiving Reservoir (기장산성 집수지의 구조와 변화양상)

  • Hwang, Dae-Il;Jung, Dae-Bong;Park, Jun-Hyun
    • Journal of architectural history
    • /
    • v.22 no.4
    • /
    • pp.35-44
    • /
    • 2013
  • This paper looked into the structure of and changes in the building process of Gijang mountain fortress and its receiving reservoir by analyzing data from an excavation investigation. The structure of the receiving reservoir may be classified into a flat form, stone sheath, floor facility, wall facility, and entry and exit facility. The flat form of the Gijang mountain fortress and receiving reservoir is round. Concerning the sectional form, the wall was obliquely excavated in the trapezoid. As a stone sheath building method, it was built by undertaking a range work of oblong stone materials in a clockwise direction on a stamped soil floor. Then, it was treated with stamping using double layers of gray clay and yellowish brown clay on the floor and the wall. Also, in a space between the stamped layers on the floor, herbal plants and a straw mat were laid for waterproofing as well as to prevent sinking. As an entry and exit facility, two facilities were confirmed symmetrically in the southeast and in the northwest. It is believed that they were built additionally during rebuilding after the initial construction. The building process was revealed to have been carried out in 8 stages. Given the structure and excavated remains, the building period is estimated to be the early to mid 7th century for the initial building, the later 9th to 11th centuries for the primary rebuilding, and the later 16th to early 17th centuries for the secondary rebuilding.

Preparation of Nanoflake Bi2MoO6 Photocatalyst Using CO(NH2)2 as Structure Orientation and Its Visible Light Degradation of Tetracycline Hydrochloride

  • Hu, Pengwei;Zheng, Dewen;Xian, Yuxi;Hu, Xianhai;Zhang, Qian;Wang, Shanyu;Li, Mingjun;Cheng, Congliang;Liu, Jin;Wang, Ping
    • Korean Journal of Materials Research
    • /
    • v.31 no.6
    • /
    • pp.325-330
    • /
    • 2021
  • Bi2MoO6 (BMO) via the structure-directing role of CO(NH2)2 is successfully prepared via a facile solvothermal route. The structure, morphology, and photocatalytic performance of the nanoflake BMO are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), fluorescence spectrum analysis (PL), UV-vis spectroscopy (UV-vis) and electrochemical test. SEM images show that the size of nanoflake BMO is about 50 ~ 200 nm. PL and electrochemical analysis show that the nanoflake BMO has a lower recombination rate of photogenerated carriers than particle BMO. The photocatalytic degradation of tetracycline hydrochloride (TC) by nanoflake BMO under visible light is investigated. The results show that the nanoflake BMO-3 has the highest degradation efficiency under visible light, and the degradation efficiency reached 75 % within 120 min, attributed to the unique hierarchical structure, efficient carrier separation and sufficient free radicals to generate active center synergies. The photocatalytic reaction mechanism of TC degradation on the nanoflake BMO is proposed.

A Study On Product Data Model for Central Database in an Integrated System for Structural Design of Building (구조설계 통합 시스템에서 중앙 데이터베이스를 위한 데이터 모델에 관한 연구)

  • 안계현;신동철;이병해
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.444-451
    • /
    • 1999
  • The purpose of this study is to Propose data models for central database in integrated system for structural design building. In order to efficiently express data related to structure, I analyzed the structure design process and classified data considering design step. 1 used an object-oriented modeling methodology for logical data model and relational modeling for physical data model. Based on this model, we will develop an integration system with several applications for structure design. Each application will communicate through the central database.

  • PDF

Seismic Performance of the Framed Apartment Building Structure with Damping System (감쇠시스템을 적용한 라멘조 아파트의 내진성능평가)

  • Chun, Young-Soo;Lee, Bum-Sik;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.8 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • To proactively respond to internal and external changes such as the recent demographic change and rising demand for diversified housing types, this study investigated the framed-structure free plan public house model proposed by the LH to look at the seismic performance of framed-structure apartment according to damper system use through non-linear analysis. The effectiveness thereof was also examined in terms of performance and economy. As a result, the proposed damper system application method to framed-structure free plan public house model was found to meet the performance requirements of the present earthquake-resistant design (KBC2016) and effective to apply to designs. The max response displacement and max response acceleration were compared based on the nonlinear analysis. As a result, the building with damper system showed better earthquake resistance performance than earthquake-resistant structure thanks to the damper system, although the base shear of earthquake-resistant system was reduced by 20% in design. The damper system is expected to help reduce building damage while ensuring excellent earthquake resistance performance. In addition, the framework quantities of earthquake-resistant structure and structure with damping system were compared. As a result, columns were found to reduce concrete amount by about 3.9% and rebar, by about 7.3%. Walls showed about 12.6% reduction in concrete and about 10.7% in rebar. In terms of cost, framework construction cost including formwork and foundation expenses was expected to drop by about 5~6%.

Seismic pounding between adjacent buildings considering soil-structure interaction

  • Raheem, Shehata E Abdel;Alazrak, Tarek M.A.;AbdelShafy, Aly G.A.;Ahmed, Mohamed M.;Gamal, Yasser A.S.
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.55-70
    • /
    • 2021
  • In urban cities, buildings were built in the neighborhood, these buildings influence each other through structure-soilstructure interaction (SSSI) and seismic pounding due to limited separation distance in-between. Generally, the effects of the interaction between soil and structure are disregarded during seismic design and analysis of superstructure. However, the system of soil-base adversely changes structural behavior and response demands. Thus, the vibration characteristics plus the seismic response of a building are not able to be independent of those in adjacent buildings. The interaction between structure, soil, and structure investigates the action of the attendance of adjacent buildings to the others by the interaction effect of the sub-soil under dynamic disturbances. The main purpose of this research is to analyze the effects of SSSI and seismic pounding on the behavior of adjacent buildings. The response of a single structure or two adjacent structures with shallow raft base lying on soft soil are studied. Three dimensions finite element models are developed to investigate the effects of pounding; gap distance; conditions of soil; stories number; a mass of adjacent building and ground excitation frequency on the seismic responses and vibration characteristics of the structures. The variation in the story displacement, story shear, and story moment responses demands are studied to evaluate the presence effect of the adjacent buildings. Numerical results acquired using conditions of soil models are compared with the condition of fixed support and adjacent building models to a single building model. The peak responses of story displacement, story moment, and story shear are studied.

Magneto-rheological and passive damper combinations for seismic mitigation of building structures

  • Karunaratne, Nivithigala P.K.V.;Thambiratnam, David P.;Perera, Nimal J.
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1001-1025
    • /
    • 2016
  • Building structures generally have inherent low damping capability and hence are vulnerable to seismic excitations. Control devices therefore play a useful role in providing safety to building structures subject to seismic events. In recent years semi-active dampers have gained considerable attention as structural control devices in the building construction industry. Magneto-rheological (MR) damper, a type of semi-active damper has proven to be effective in seismic mitigation of building structures. MR dampers contain a controllable MR fluid whose rheological properties vary rapidly with the applied magnetic field. Although some research has been carried out on the use of MR dampers in building structures, optimal design of MR damper and combined use of MR and passive dampers for real scale buildings has hardly been investigated. This paper investigates the use of MR dampers and incorporating MR-passive damper combinations in building structures in order to achieve acceptable levels of seismic performance. In order to do so, it first develops the MR damper model by integrating control algorithms commonly used in MR damper modelling. The developed MR damper is then integrated in to the seismically excited structure as a time domain function. Linear and nonlinear structure models are evaluated in real time scenarios. Analyses are conducted to investigate the influence of location and number of devices on the seismic performance of the building structure. The findings of this paper provide information towards the design and construction of earthquake safe buildings with optimally employed MR dampers and MR-passive damper combinations.