• Title/Summary/Keyword: Building mechanical System

Search Result 590, Processing Time 0.032 seconds

Building System Analysis and Integration: Case Study on Richards Medical Research Building (건물시스템의 분석과 통합 방법에 관한 연구: 리차즈 의학 연구소 건물의 사례분석을 중심으로)

  • Choi, Joon-Sung;Im, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1444-1451
    • /
    • 2011
  • The purpose of this paper is to provide an understanding of building systems and to propose methods of building system analysis and integration. Building components are classified into four major systems; structure, mechanical, envelope, and interior system. There are 11 combinations between major systems. Three integration modes(physical, visual, and functional integration) and 12 integration strategies are proposed. A case study of Richards Medical Research Buildings designed by Louis I. Kahn was conducted from the perspective of building system analysis and integration.

Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building (숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구)

  • Choi, Young-Don;Han, Seong-Ho;Cho, Sung-Hwan;Kim, Du-Sung;Um, Chul-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

System Identification and Controller Design of a Small-scale Building Structure using Matlab (Matlab을 이용한 축소 모형건물의 시스템 식별과 제어기 설계)

  • Min, Kyung-Won;Kim, Sung-Choon;Hwang, Seong-Ho;Ho, Kyoung-Chan;Joung, Jin-Wook;Joo, Soek-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.978-983
    • /
    • 2000
  • This paper presents the system identification of a small-scale building model with an active mass driver and the controller design using Matlab program. As the AMD is a mechanical system which has a dynamic characteristic and whose mass can not be neglected compared to that of the building mass, the AMD-building interaction should be included in the controller design. The system identification is carried out for the AMD-building system with two acceleration inputs of the shaking table and the AMD and single acceleration output of the building. The mathematical model for the AMD-building is obtained and compared with the experimental result. The controller is designed based on the mathematical model using the optimal control algorithm of LQG strategy. The experimental results are compared with the numerical results. It is shown that both results are in good agreement in the system identification and the controlled responses.

  • PDF

A Study on the Building Design Guideline Development Considering Photovoltaic Panel Installation (태양광 패널 설치를 고려한 건축 디자인 지침 개발 연구)

  • Moon, Chang-Ho
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.139-146
    • /
    • 2019
  • The purpose of this study is to propose the building design guideline considering photovoltaic panel installation through the analysis of relevant guidelines from home and abroad in terms of building design and solar panel installation. Conclusions can be summarized as followings; Considerations in building design : selection of the site with high solar accessibility, avoidance of the shade from the adjacent building & trees, south facing orientation of solar panel in building design, removal of shade on the solar panel from the part of building itself, load consideration of solar panel & fixing materials, safe passage securement for solar system maintenance, and planning of piping and mechanical room for solar system. Considerations in solar panel installation : harmonizing of solar panel with surrounding environment, unity of solar panel orientation & slope, regular maintenance of solar system, (in case of flat roof installation) solar panel installation afloat over the roof, installation area within the roof floor, and lower than parapet height, (in case of sloped roof installation) solar panel installation parallel with the roof slope, ventilation space securement below the panel, installation area within the roof surface, and similar material installation in empty space.

Modeling for Distributed Control of Elevator (엘리베이터 분산 제어를 위한 모델링)

  • Lee, Myung-Un;Jung, Soo-Young;Kwon, Wook-Hyun;Choe, Gyu-Ha
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1620-1624
    • /
    • 2003
  • Recently, the height of building is more high and the number of moving people is increasing in the building. So we want to be necessary more effective vertical moving tool. Most of high intelligent building can satisfy tills need using many elevators. Many elevators system should need to distribute and distribute many elevator effectively. This paper effectively use many elevators to reduce customer' waiting time and propose the model of mathematical group control system.

  • PDF

The Performance Field-Application of Natural Ventilation System (자연환기시스템의 현장 적용성 평가-열환경,에너지부분)

  • Choi, Dong-Hyuk;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.689-694
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high isulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, open module type natural ventilation window system for energy saving included a fixed and continuous quantity ventilation was developed. The purpose that indoor thermal comfort environment evaluate of indoor resident.

  • PDF

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

Improvement of Natural Ventilation in a Factory Building Using a Velocity Field Measurement Technique (PIV 속도장 측정기법을 이용한 공장 실내환기 개선방안 연구)

  • Im, Hui-Chang;Kim, Hyeong-Beom;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1427-1435
    • /
    • 2001
  • Air movement in wokplaces, whether resulting from a forced ventilation system or naturally occurring airflow, has a significant impact on occupational health. In a huge shipbuilding factory building, typical harmful factors such as fume or vaporized gas from welding and cutting of steel plates, and dusts from grinding give unpleasant feeling. From field data survey, the yearly dominant, wind directions for the shipbuilding factory building tested were northwest, northeast and southeast Among the three wind directions, the ventilation improvement was the worst for the northeastern wind. This study was focused on location of the opening vents in order to utilize the natural ventilation effectively. Instantaneous velocity fields inside the 1/1000 scale-down factory building model were measured using a 2-frame PIV system. The factory building model was embedded in an atmospheric boundary layer simulated in a wind tunnel. The modified vents improve the internal Ventilation flow with increasing the flow speed more than two times, compared with that of present vents.

Optimization of the Community Energy Supply System for D-Cube City, Multi Purpose Building (복합건물(D-Cube City) 지역에너지 공급체계 최적화)

  • Lee, Tae-Won;Kim, Yong-Ki;Lee, Kun-Woo;Lee, Ki-Bong;Cho, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.669-674
    • /
    • 2012
  • D-Cube City is a recently completed multi purpose building consisting of four types of facilities; offices, a department store, a hotel, and congregation spaces. A community energy supply system(CES) has been installed to supply this building with electricity, steam, heat, and cold water. The BEMS, building energy management system, is currently being designed to reduce building energy consumption through the efficient operation of the various pieces of building service equipment. In this study the optimal methods for operating the CES of D-Cube City were considered. This system includes three combined heat and power systems, seven steam boilers, two hot water boilers, two absorption chillers, and four turbo chillers, and various other pieces of equipment. In result, the optimal methods of operating the CES for various energy demand levels were obtained along with the seasonal effects on the economic efficiency of the operation. The effect of the amount of energy demanded by the various facility areas on the total energy consumption was also analyzed.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.