• Title/Summary/Keyword: Building energy supply system

Search Result 199, Processing Time 0.028 seconds

Development of Low-voltage Seamless Transfer Microgrid on Grid-connected Type Islands by Autonomous Operation (자율운전에 의한 계통연계형 도서의 저압 무순단 마이크로그리드 구축)

  • Kim, Jeong Hun;Kwon, Jung-Min;Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.169-176
    • /
    • 2017
  • This paper presents research on low-voltage microgrids to maintain a continuous power supply to critical loads on grid-connected islands in Korea. The low-voltage microgrids of this paper focused on that changes public office buildings into uninterrupted microgrids by autonomous operation. For this, a microgrid controller (MGC) and a power conditioning system (PCS) that allow a seamless transfer between grid-connected and grid-isolated operation are proposed. The proposed PCS operates with a silicon controlled rectifier (SCR) switch and employs a simple structure. It supplies power continuously without operators through a coordinated operation between MGC and PCS. In addition, proposed MG has a schedule operation for minimizing electricity charges and provides ancillary services that enable the utilization of resources according to the operation purpose of utility distribution networks. To demonstrate the uninterrupted low-voltage microgrid proposed in this study, a microgrid was implemented and tested in a public office building in Anjwa Island, Jeollanam-do in Korea. A seamless, autonomous operation history, despite system disturbances, was obtained through a long-term demonstration of operation. The results showed that the proposed microgrid technology can be used to achieve energy resilience in grid-connected island areas.

The Heat Exchangers Performance Experiment for a Field Application Ice Slurry Cooling System (현장 적용 아이스슬러리 시스템의 열교환기 성능 실험)

  • Lee, Sang-Hoon;Yoo, Ho-Seon;Lee, Yoon-Pyo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1002-1007
    • /
    • 2009
  • The research are performed to check the characteristics of the ice slurry transport system for the district cooling. The system are installed at the 1st floored building which is as large as the $1204\;m^2$ ($86\;m{\times}14\;m$). Three kinds of heat exchanger are selected, such as, plate, spiral and shell & tube type, to apply to the ice slurry systems. Experiment was done in the two cases. The first case, circulation water flow fixed at the design conditions for the state to change the flow of the supply of ice slurry. The second case, Ice slurry flow fixed at the design conditions for the state to change the flow of circulation water. Both side of Energy balance was calculated. The performance of plate heat exchanger is higher than others and it's enthalpy effectiveness is higher too.

  • PDF

Experimental and theoretical justification of passive heat removal system for irradiated fuel assemblies of the nuclear research reactor in a spent fuel pool

  • Ta Van Thuong;O.L. Tashlykov;S.M. Glukhov;D.E. Shumkov;Yu.V. Volchikhina
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2088-2095
    • /
    • 2023
  • The safety of nuclear installations is largely determined by the tightness of fuel elements cladding. As the Fukushima nuclear accident showed, the main task in case of loss of power supply is to ensure reliable removal of residual heat release from spent fuel pool (SFP) with irradiated fuel assemblies (IFAs). The paper presents the results of calculated-experimental studies and thermal-hydraulic modeling of temperature storage modes of IFAs in SFP. Experimental studies of SFP's temperature regime and calculated evaluation of residual heat removal due to the thermal conductivity of building structures surrounding the SFP were performed. To ensure the safe operation of research reactors, it's necessary to know the IFA's residual heat power (RHP) in the reactor and SFP, which is determined depending on the operating time of fuel assemblies (FAs) and the IFAs calculated holding time. The FAs operating time depends on the reactor energy output. The IFAs calculated holding time is determined by the fuel burnup, U-235 mass in the fuel, and reactor utilization factor. The IFAs fuel burnup was calculated using the MCU-PTR program. Also presented are the RHP's calculation results using some of the empirical dependencies. The concept of a passive heat removal system (PHRS) based on thermosyphon's operating principle was proposed.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

Design and Implementation of Wireless standby Power Control System for Energy Saving (에너지 절감을 위한 무선 대기전력 제어 시스템 설계 및 구현)

  • Sim, Gab-Sig;Jang, Jae-Hyuk
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.5
    • /
    • pp.19-27
    • /
    • 2013
  • This paper implements the standby power control system composed of a master device and slave devices. The standby power is managed by cutting power supply after controlling the relay of a slave device based on the authentication of master device's RFID card. RFID interface and wireless communication module are embedded in a master device, and one master device is linked with many slave devices in wireless. Each slave device executes the operation needed in power control independently. We implements the function of manual power on/off system in a slave device, and the function of user ID enrollment by switch manipulation in a master device. Also this system can communicate bidirectionally in wireless and runs on TinyOS. The result of experiment shows that the user authentication is executed in a master device and this authenticated information is transmitted to a slave device in wireless, and standby power is cutted by controlling the relay of a slave device. Installing this system in a building or an office, we can expect energy saving.

Research on the Direction of Forming Rural and Fishing Village Type Community Living Home through Regeneration - With Focus on Community Living Home in Wolmunli, Cheongcheon-myeon, Goesan-gun, Chungbuk - (재생을 통한 농어촌마을형(型) 공동생활 홈 조성 방향에 관한 연구 - 충북 괴산군 청천면 월문리 그룹 홈을 중심으로 -)

  • Kim, Seung-Keun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • Problems of housing, healthcare, social exchanges, and lonely feelings of vulnerable social groups such as the elderly living alone in rural and fishing villages should be resolved by guaranteeing minimum residential rights and levels to restore the sense of self-esteem and social stability and to maintain the rural communities and these should be the object of social interest and support. The housing problems of rural and fishing villages should be resolved not through supply to meet demand but by beginning with providing the ways to attain mutual interaction through the program that recognizes housing as merit goods to maintain the regional communities This research examines more minutely the problems caused by poor housing conditions of rural and fishing villages and attempts to present rural and fishing village type community living home as an alternative through regeneration. The results of this research are as follows. First, the administrative support system should be built to support the community living home in its beginning, process, completion, and even post management. Second, education for reinforcing capabilities to help understand the community living home should continually conducted on the occupants, villagers, and related organizations. Third, in order to expand the community living home, research and development should be made so that the zero-energy house, the alternative energy utilizing house, etc. can be widely used. In building community living home for vulnerable social groups in rural and fishing villages, practical alternatives suitable to the regional realities should be presented and practiced so that the community living home can be built to the satisfaction of all the villagers and the occupants, and the improvement measures should be presented through constant interest and monitoring.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

A Study on the Priority of Site Selection for Hydrogen Vehicle Charging Facilities in Seoul Using a Market Demand Prediction Model (시장수요예측 모델을 활용한 서울시 수소차 충전시설의 입지선정 우선순위에 관한 연구)

  • Jin Sick, Kim;Kook Jin, Jang;Joo Yeoun, Lee;Myoung Sug, Jung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.18 no.2
    • /
    • pp.140-148
    • /
    • 2022
  • Hydrogen is expected to be widely applied in most sectors within the current energy system, such as transportation and logistics, and is expected to be economically and technologically utilized as a power source to achieve vehiclebon emission reduction. In particular, the construction of hydrogen charging station infrastructure will not only support the distribution of hydrogen electric vehicles, but also play an important role in building a hydrogen logistics system. Therefore, This paper suggest additional charging infrastructure areas in Seoul with a focus on supply according to the annual average growth rate (CAGR), centering on Seoul, where hydrogen vehicles are most widely distributed. As of February 2022, hydrogen charging infrastructures were installed in Gangseo-gu, Gangdong-gu, Mapo-gu, Jung-gu, and Seocho-gu in downtown Seoul. Next, looking at the number of hydrogen vehicles by administrative dong in Seoul from 2018 to 2022, Seocho-gu has the most with 246 as of 2022, and Dongjak-gu has the highest average growth rate of 215.4% with a CAGR of 215.4%. Therefore, as a result of CAGR analysis, Dongjak-gu is expected to supply the most hydrogen vehicles in the future, and Seocho-gu currently has the most hydrogen vehicles, so it is likely that additional hydrogen charging infrastructure will be needed between Dongjak-gu and Seocho-gu.

Development of Building System for Achieving an Optimal Growth Environment in a Vertical Smart Farm (수직형 스마트 팜의 적정 생육환경 조성을 위한 건축 시스템 개발 - 수직형 스마트 팜에 최적화된 내부 공기 균일성 향상에 대한 연구 -)

  • Kim, Handon;Lee, Jeonga;Choi, Seun;Jang, Hyounseung;Kim, Jimin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.4
    • /
    • pp.3-10
    • /
    • 2021
  • According to the IPCC, humans are influencing the climate system. Such changes in the climate system can cause problems in the supply of food ingredients in the agricultural field by changing the existing growing environment. To solve this problem, vertical farms can be a good alternative for a stable supply of food ingredients. Although the vertical smart farm pays close attention to maintaining and managing the growing environment of crops, it is difficult to uniformly implement temperature, humidity, illumination, oxygen, and carbon dioxide concentrations in the building space. As a result of conducting computational fluid dynamics analysis to ensure air uniformity, a remarkable result is that it is advantageous to continuously spray suitable carbon dioxide CO2 concentrations for a long period of time for air uniformity in a vertical smart farm. Through this result, it is possible to efficiently plan a growing environment system optimized for a vertical smart farm. Based on this study, if efficient crops are produced by creating an optimized growing environment for vertical smart farms, it will be able to contribute to the development of the agricultural field.