• 제목/요약/키워드: Building energy performance

검색결과 1,438건 처리시간 0.028초

음영에 의한 손실을 고려한 태양광 발전 추적 시스템 (Photovoltaic tracking system considered loss by shadow)

  • 최정식;고재섭;정철호;김도연;정병진;정동화
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.135-141
    • /
    • 2008
  • In this paper a novel tracking system is described, regarding the influence of shadow between array, aimed at improving the efficiency of PV tracking system. Comparing with a building site versus capacity power, domestic solar powers have a limited siting. Therefore, each array interferes with the shadow of other arrays. The loss by influence of those shadow can be compensated for by means of control algorithm of the tracking device. The paper suggests a method controlling an altitude for length which is received the shadow influence of PV array. By using an azimuth of current solar position and the length between arrays, the controller of tracking device is able to calculate the length between actual arrays and make a comparison of the shadow length at a specific time with the length between arrays. When the shadow length is longer than the length between arrays, the controller of tracking device can adjust a position by compensating error altitude of the length between arrays at an altitude of current solar position. In the paper, we develop the control algorithm able to minimize the loss caused by the influence of shadow on the PV tracking system, and compared this with conventional output system. The controller has been tested in the laboratory with proposed algorithm and shows excellent performance

  • PDF

대각측량 방식을 이용한 실내 측위 정확도 개선에 관한 연구 (A Study on Improvement of Indoor Positioning Accuracy Using Diagonal Survey Method)

  • 정현기;박태현;권장우
    • 한국ITS학회 논문지
    • /
    • 제17권5호
    • /
    • pp.160-172
    • /
    • 2018
  • 위성항법장치(GPS)를 이용한 위치 추정 방법은 자동차의 내비게이션 시스템을 비롯한 다양한 분야에서 응용되고 있다. 하지만 GPS 신호는 실내에서 측정이 어려우므로 건물이나 공장과 같은 실내에서 특정 물체의 위치를 파악하기에는 어려움이 많다. 본 연구에서는 이러한 한계점을 극복하기 위하여 공장 내에서의 물자관리를 위해 저전력 블루투스(BLE) 기반의 객체 위치 추정하는 시스템을 제안한다. 객체위치 추정 시스템은 블루투스 신호 발생기, 수신기, 그리고 데이터베이스 서버로 이루어져 있으며 물자에는 BLE를 기반으로 하는 신호 발생기를 부착하고, 공장 내부에 수신기를 적절하게 배치하여 구성하였다. 또한 본 연구에서 기존의 삼변 측량법의 오차를 감소시키기 위해 4개의 수신기를 사용하는 4축 측량알고리즘인 "대각측량"을 제안한다. 제안하는 알고리즘은 기존 삼변측량대비 우수한 성능을 보였으며 공장에 시스템을 설치하여 실험을 수행함으로써 본 연구에서 제안하는 시스템과 알고리즘의 실효성을 증명하였다.

유기고분자로 표면 개질 된 입상활성탄을 이용한 프러시안 블루 고정화 및 Cs+ 제거 (Covalent organic polymer grafted on granular activated carbon surface to immobilize Prussian blue for Cs+ removal)

  • 서영교;오대민;황유훈
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.399-409
    • /
    • 2018
  • Prussian blue is known as a superior material for selective adsorption of radioactive cesium ions; however, the separation of Prussian blue from aqueous suspension, due to particle size of around several tens of nanometers, is a hurdle that must be overcome. Therefore, this study aims to develop granule type adsorbent material containing Prussian blue in order to selectively adsorb and remove radioactive cesium in water. The surface of granular activated carbon was grafted using a covalent organic polymer (COP-19) in order to enhance Prussian blue immobilization. To maximize the degree of immobilization and minimize subsequent detachment of Prussian blue, several immobilization pathways were evaluated. As a result, the highest cesium adsorption performance was achieved when Prussian blue was synthesized in-situ without solid-liquid separation step during synthesis. The sample obtained under optimal conditions was further analyzed by scanning electron microscope-energy dispersive spectrometry, and it was confirmed that Prussian blue, which is about 9.7% of the total weight, was fixed on the surface of the activated carbon; this level of fixing represented a two-fold improvement compared to before COP-19 modification. In addition, an elution test was carried out to evaluate the stability of Prussian blue. Leaching of Prussian blue and cesium decreased by 1/2 and 1/3, respectively, compared to those levels before modification, showing increased stability due to COP-19 grafting. The Prussian blue based adsorbent material developed in this study is expected to be useful as a decontamination material to mitigate the release of radioactive materials.

신한옥 건설 특성을 반영한 표준품셈 개발 (Estimating Standards and Cost Data for Modernized Korean Hosing (Hanok))

  • 김수지;김민;이윤섭;정영수
    • 한국건설관리학회논문집
    • /
    • 제17권1호
    • /
    • pp.66-75
    • /
    • 2016
  • 최근 한옥의 수요 증가에 따라 전통한옥을 보급화 하기 위한 방안으로 신한옥이 개발되었다. 신한옥이란 전통한옥 보급의 저해 요인으로 작용하였던 높은 평단가 및 건축물 성능 보완하여 개발한 한옥의 한 형태이다. 신한옥이 개발되어 짐에 따라 보급화, 표준화, 생산성 향상 등을 위한 다양한 연구들이 진행되고 있다. 그 중, 신한옥을 건설하기 위하여 필수적 요소로 논의되는 예가 산정의 한 측면으로 품셈에 대한 요구가 지속된다. 이에, 본 연구에서는 신한옥 건설 특성을 반영한 표준품셈을 제안한다. 연구의 방법으로는 기존의 품셈 및 Cost Data 체계를 분석하여 신한옥과 부합하는 품셈구조를 제시하고, 실제 구축사례를 통한 세부항목의 선정과 1차적 검증을 실시하였다. 해당 신한옥 표준품셈은 신한옥 표준정보분류체계와 연계되어 있어 다방면에서 효율적인 활용이 가능하다. 또한, 추가 신한옥 구축을 통하여 데이터가 업데이트되면 보다 신뢰할 수 있는 표준품셈이 될 것으로 기대한다.

역V형 가새골조의 반응수정계수 (The Response Modification Factor of Inverted V-type Braced Steel Frames)

  • 안형준;김송매
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 2013
  • 철골구조에서 지진력 저항시스템으로 많이 사용되고 있는 가새골조시스템은 중심가새골조(Concentrically Braced Frames, CBF)와 편심가새골조(Eccentrically Braced Frames, EBF)로 구분하여 KBC2009 건축구조기준에서는 서로 다른 반응수정계수를 적용하여 설계하도록 되어있다. 현행 내진설계기준에서 편심가새골조에 대하여 링크 타단 접합부의 종류에 따라 모멘트 저항접합일 경우 반응수정계수는 R=8, 비모멘트 저항접합일 경우 반응수정계수 R=7로 적용하여 설계하도록 규정하고 있을 뿐 편심길이의 영향을 고려하지 않고 있다. 본 연구에서는 편심가새골조 중에서 역V형가새골조를 대상으로 비탄성 거동을 파악한 다음 편심길이에 따른 반응수정계수를 산정하여 내진설계 기준에서 제시한 값과 비교한 결과 편심가새골조에 대하여 동일한 반응수정계수를 적용하는 것은 적절하지 않음을 확인하였다.

유한요소해석을 통한 섬유보강 아스팔트의 파괴거동특성 분석 (Finite Element Analysis for Fracture Resistance of Fiber-reinforced Asphalt Concrete)

  • 백종은;유평준
    • 한국도로학회논문집
    • /
    • 제17권3호
    • /
    • pp.77-83
    • /
    • 2015
  • PURPOSES : In this study, a fracture-based finite element (FE) model is proposed to evaluate the fracture behavior of fiber-reinforced asphalt (FRA) concrete under various interface conditions. METHODS : A fracture-based FE model was developed to simulate a double-edge notched tension (DENT) test. A cohesive zone model (CZM) and linear viscoelastic model were implemented to model the fracture behavior and viscous behavior of the FRA concrete, respectively. Three models were developed to characterize the behavior of interfacial bonding between the fiber reinforcement and surrounding materials. In the first model, the fracture property of the asphalt concrete was modified to study the effect of fiber reinforcement. In the second model, spring elements were used to simulated the fiber reinforcement. In the third method, bar and spring elements, based on a nonlinear bond-slip model, were used to simulate the fiber reinforcement and interfacial bonding conditions. The performance of the FRA in resisting crack development under various interfacial conditions was evaluated. RESULTS : The elastic modulus of the fibers was not sensitive to the behavior of the FRA in the DENT test before crack initiation. After crack development, the fracture resistance of the FRA was found to have enhanced considerably as the elastic modulus of the fibers increased from 450 MPa to 900 MPa. When the adhesion between the fibers and asphalt concrete was sufficiently high, the fiber reinforcement was effective. It means that the interfacial bonding conditions affect the fracture resistance of the FRA significantly. CONCLUSIONS : The bar/spring element models were more effective in representing the local behavior of the fibers and interfacial bonding than the fracture energy approach. The reinforcement effect is more significant after crack initiation, as the fibers can be pulled out sufficiently. Both the elastic modulus of the fiber reinforcement and the interfacial bonding were significant in controlling crack development in the FRA.

초고층 공동주택 국소배기용 입상덕트의 배기성능평가 (The Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;김웅용;신현곤
    • 유기물자원화
    • /
    • 제22권3호
    • /
    • pp.60-67
    • /
    • 2014
  • 고층 공공주택의 화장실과 주방에 적용되는 배기 시스템은 기본적으로 두 종류의 환기팬이 적용된다. 가지 기본 유형의 지붕 팬이다. 그 하나가 자연 통풍력을 활용하는 무동력 팬이고 다른 하나는 자연 통풍력이 없을 때, 모터를 활용하여 강제로 구동하는 팬을 적용하는 방식이다. 자연/강제 겸용으로 지붕에 적용되는 환기팬은 회전축에 모터가 있습니다. 대한민국에는 많은 고층건물이 있다. 그러나 고층건물의 환기가 굴뚝효과에 의존된다고 판단하였기 때문에 이러한 건물의 실내에서 발생하는 오염물질의 제거에 대한 관심을 크게 갖지 않고 있다. 본 연구는 외기압력과 초고층아파트에 사용되는 배기연돌에 적용되는 차압에 의해 결정되는 연돌압력을 조사하기 위함이다. 본 논문은 화장실 배기풍량과 대기의 자연풍속을 변수로 하여 루프팬에 설치된 모타의 전력공급시간을 판단함으로써 기존 배기팬보다 향상된 배기효율을 예측하기 위해, 수행되었다.

Development and testing of cored moment resisting stub column dampers

  • Hsiao, Po-Chien;Lin, Kun-Sian;Liao, Wei-Chieh;Zhu, Limeng;Zhang, Chunwei
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.107-122
    • /
    • 2020
  • Moment resisting stub columns (MRSCs) have increasingly adopted in special moment-resisting frame (SMF) systems in steel building structures, especially in Asian countries. The MRSCs typically provide a lower deformation capacity compared to shear-panel stub columns, a limited post-yield stiffness, and severe strength degradation as adopting slender webs. A new MRSC design with cored configuration, consisting of a core-segment and two side-segments using different steel grades, has been proposed in the study to improve the demerits mentioned above. Several full-scale components of the cored MRSC were experimentally investigated focusing on the hysteretic performance of plastic hinges at the ends. The effects of the depths of the core-segment and the adopted reduced column section details on the hysteretic behavior of the components were examined. The measured hysteretic responses verified that the cored MRSC enabled to provide early yielding, great ductility and energy dissipation, enhanced post-yield stiffness and limited strength degradation due to local buckling of flanges. A parametric study upon the dimensions of the cored MRSC was then conducted using numerical discrete model validated by the measured responses. Finally, a set of model equations were established based on the results of the parametric analysis to accurately estimate strength backbone curves of the cored MRSCs under increasing-amplitude cyclic loadings.

중소기업의 스마트팩토리 환경을 위한 IoT 장치 간 연계 알고리즘 (Linking Algorithm between IoT devices for smart factory environment of SMEs)

  • 정윤수
    • 융합정보논문지
    • /
    • 제8권2호
    • /
    • pp.233-238
    • /
    • 2018
  • 중소기업 및 영세기업들은 생산관리 뿐만 아니라 설비, 안전, 에너지 관리 측면에서 중소기업의 운영 관리를 위해서 다양한 시도를 하고 있다. 그러나, 중소기업은 투자 여력이 없어 중소기업의 경영 개선과 생산성 향상을 위한 스마트팩토리 구축이 쉽지 않은 상황이다. 본 논문에서는 중소기업에서 현재 운영 중인 공장 장비를 부분적으로 연동하는 스마트팩토리를 구축 알고리즘을 제안한다. 제안 알고리즘은 중소기업의 스마트팩토리 환경을 단계적으로 구축하여 운영할 수 있도록 전체 제조 공정 중 제품 정보와 출시 정보를 IoT 장치에 이용하여 수집 보관 관리 처리 하도록 하고 있다. 또한, 제안 알고리즘은 장치간 인증 정보를 중앙의 서버가 중앙집중식으로 관리함으로써 IoT 장치 수에 상관없이 IoT간 연계를 자동화하는 특징이 있다. 성능평가 결과, 제안 알고리즘은 스마트팩토리 환경을 구축하기 전의 공장 프로세스와 효율성을 평가한 결과 13.7% 향상된 결과를 얻었고, 공장 내 제품 처리 시간도 19.8% 향상된 결과를 얻었다. 또한, 공정 프로세스에 투입된 인력 투입 비용도 37.1% 감소된 결과를 얻었다.

폐콘크리트 순환자원을 이용한 건설재료의 화재내력 및 단열성에 관한 실험적 연구 (Experimental Study on Fire Resistant Capacity and Thermal Conduction of Construction Material Using the Circulation Resources)

  • 최재남;홍세화;손기상
    • 대한안전경영과학회지
    • /
    • 제12권3호
    • /
    • pp.121-128
    • /
    • 2010
  • This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. In addition, thermal conduction test was tested in order to find out concrete insulation. According to this test, when concrete was tested by fire resistance, it using the circulation aggregate was same resulted by concrete using the natural aggregate. also, recycle powder was not effecting insulation performance. but it is fit to standard on concrete insulation of building law.