• Title/Summary/Keyword: Building energy consumption characteristics

Search Result 143, Processing Time 0.026 seconds

A Sensitivity Analysis about Solar Heat Gain and Heating Load of ZeSH According to Optical Characteristics of Window system (창호의 광학적 특성에 따른 ZeSH의 일사취득 및 난방부하에 관한 민감도 분석)

  • Son, Sun-Woo;Baek, Nam-Choon;Suh, Seung-Jik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.66-71
    • /
    • 2009
  • To reduce the building energy consumption, the major advanced nations are conducting actively many researches on so called a "self-sufficient building(or other words zero energy building)" which can support its required energy by itself. Given this background, KIER(Korea Institute of Energy Research) built full size test-bed of the zero energy solar house in early 2002, and has studied on the self-sufficient heating load up to now. We analyse the sensitivity between the heating load and the solar radiation gain according to the change the effective transmittance of windows. The authors classified 9 cases by solar transmittance of glass. The results demonstrate the solar radiation amount is 0.466 MWh from the eastern zone of Fl.,1(the first floor), 0.332 MWh from Fl.,2(the second floor), 1.194 MWh form the southern zone of F1., and 0.822 MWh from the southern zone of Fl.,2 on the case 1(each cases are classified by window types). On the case 9, the solar radiation amount is 3.127 MWh, 2.662 MWh, 8.799 MWh and 6.078 MWh from the same condition. For the Fl.,1, the amount of Heat Load that is saved per year ranged 10.5 to 48 %, and the reduction was anywhere from 0.2 to 17.9% for Fl.,2

  • PDF

Multi-family Housing Complex Breakdown Structure for Decision Making on Rehabilitation (노후 공동주택 개선여부 의사결정을 위한 공동주택 분류체계 개발)

  • Hong, Tae-Hoon;Kim, Hyun-Joong;Koo, Choong-Wan;Park, Sung-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.101-109
    • /
    • 2011
  • As climate change is becoming the main issue, various efforts are focused on saving building energy consumption both at home and abroad. In particular, it is very important to save energy by maintenance, repair and rehabilitation of existing multi-family housing complex, because energy consumption in residential buildings is not only forming a great part of gross energy consumption in Korea but the number of deteriorated complexes is also sharply increasing. However, energy saving is not considered as a main factor in decision making on rehabilitation project. Also, any supporting tool is not appropriately prepared in existing process. As the first step for development of decision support system on rehabilitation, this paper developed a breakdown structure, which makes clusters of multi-family housing complexes. Decision tree, one of data mining methods, was used to make clusters based on the characteristics and energy consumption data of multi-family housing complexes. Energy saving and CO2 reduction will be maximized by considering energy consumption during rehabilitation process of multi-family housing complex, based on these results and following research.

EA Study on the Operation Performance of Central Plant Equipment According to Part Load Characteristics (부분부하 특성을 고려한 열원기기의 운전성능 평가)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.392-397
    • /
    • 2013
  • To fulfill the demands concerning energy efficiency for zero energy buildings, various technologies of architects and engineers are required. This study aims to estimate the thermal performance of heat source equipment in which part load characteristics are considered in an office building. Overestimation of heat source equipment was reviewed through literature survey, and heating and cooling loads depending on the capacity and division of the equipment were analyzed through a simulation program (DOE-2.1E). The conclusions gained from this study are as follows; 1) The more the division of equipment, the less the heating and cooling energy consumption. 2) When a large item of equipment is divided into two small items of equipment, the optimum application rate showed as 5:5 for chiller, and 7:3 for boiler, respectively.

Energy Efficiency Improvement and Field Scale Study of Crematory using Computation Fluid Dynamics (전산유동해석을 통한 화장로의 에너지 효율개선 및 실증연구)

  • Won, Yong-Tae;Lee, Seung-Mok
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.95-101
    • /
    • 2019
  • The cremation rate of Korea in 2016 was 82.7% which is four times greater than 20.5% in 1994. As increasing the cremation rate gradually, it cause a shortage of cremation facilities resulting in building more cremation facilities to meet the increasing inquiries on cremation or a large amount of fuels for the longer operation of the crematory. In this study, the crematory system optimizing its thermal efficiency characteristics and also responding to increasing inquiries on cremation was proposed in order for solving such problems, In particular, the heat flow characteristics including a heat transfer coefficient by performing a simulation using computational fluid dynamics (CFD) was investigated. The CFD model was validated with on-site experiments for a cremation facility. As a result of the simulation, the fuel consumption decreased nearly 25% and residence time increased in the main combustor. Also, the improved crematory was constructed with an expanded combustor, heat exchanger, second combustion air system, refractory and insulation material. From on-site experiments, the energy consumption was saved to approximately 54.4%, while the burning time reduced nearly 20 minutes.

The Analysis CO2 Emission and Economic Efficiency of High-rise Apartment Houses (초고층 공동주택의 CO2 배출량과 경제성 분석에 관한 연구)

  • Roh, Seung-Jun;Tae, Sung-Ho;Kim, Tae-Hyoung;Keum, Won-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.47-48
    • /
    • 2012
  • In this study, the CO2 emission and economic efficiency of high-rise apartment houses were evaluated, and were analyzed as a way to establish database on the evaluation of environment-friendliness of high-rise buildings. To that end, standard of buildings to be evaluated were proposed through analysis of the designing guideline for high-rise apartment houses proposed by Seoul city, and CO2 emission of the subject buildings were evaluated based on the characteristics of materials admitted into each building and the amounts of energy consumed during lifecycle period. In addition, the initial costs in construction stage and annual costs in operation stage were set as analysis parameters, and along with calculation of direct cost by the consumption of construction materials and energy, the costs of CO2 emission were evaluated and analyzed. As a result, the CO2 emission and economic efficiencies of high-rise apartment houses by construction stage and operation stage could be analyzed quantitatively.

  • PDF

A Study on LEED v3(2009) Sustainable Neighborhood Development - Focused on LEED for Neighborhood Development (LEED v3(2009)에서의 친환경 단지 개발에 관한 연구 - LEED for Neighborhood Development를 중심으로)

  • Ahn, Dong-Joon
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.11-18
    • /
    • 2011
  • Sustainability became the keyword of our society worldwide, and it is undoubtful that buildings are mainly responsible for green house gas emission and energy consumption. Responding to current needs, US Green Building Council has launched the first LEED rating system in 1998. Since then, LEED has been evolved and it has multiple sub-system categorized by project types. This study aims to analyze characteristics of sustainable neighborhood development and to suggest methodology for establishing certification system in Korea. First, LEED-ND 2009(LEED for Neighborhood Development) was addressed with certified projects by US Green Building Council. After that, LEED-NC 2009(LEED for New Construction) was compared with green building certification criteria in Korea to find out unforeseen aspects by each system, in terms of sustainable neighborhood development. As a result of this study, sustainable neighborhood development requires a transition of architects' responsibility beyond building design. Building technology has been advanced at extremely fast pace, however, applying techniques to individual architecture would not make our town sustainable. This study provided basic resources to understand that creating sustainable neighborhood is social phenomenon and more studies should be undertaken to establish Green Neighborhood Certification Criteria in Korea.

A Study for Space-based Energy Management System to Minimizing Power Consumption in the Big Data Environments (소비전력 최소화를 위한 빅데이터 환경에서의 공간기반 에너지 관리 시스템에 관한 연구)

  • Lee, Yong-Soo;Heo, Jun;Choi, Yong-Hoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.229-235
    • /
    • 2013
  • This paper proposed the method to reduce and manage the amount of using power by using the Self-Learning of inference engine that evolves through learning increasingly smart ways for each spaces with in the Space-Based Energy Management System (SEMS, Space-based Energy Management System) that is defined as smallest unit space with constant size and similar characteristics by using the collectible Big Data from the various information networks and the informations of various sensors from the existing Energy Management System(EMS), mostly including such as the Energy Management Systems for the Factory (FEMS, Factory Energy Management System), the Energy Management Systems for Buildings (BEMS, Building Energy Management System), and Energy Management Systems for Residential (HEMS, Home Energy Management System), that is monitoring and controlling the power of systems through various sensors and administrators by measuring the temperature and illumination.

Topology optimization of the photovoltaic panel connector in high-rise buildings

  • Lu, Xilin;Xu, Jiaqi;Zhang, Hongmei;Wei, Peng
    • Structural Engineering and Mechanics
    • /
    • v.62 no.4
    • /
    • pp.465-475
    • /
    • 2017
  • Photovoltaic (PV) panels are used in high-rise buildings to convert solar energy to electricity. Due to the considerable energy consumption of high-rise buildings, applying PV technology is of great significance to energy saving. In the application of PV panels, one of the most important construction issues is the connection of the PV panel with the main structures. One major difficulty of the connection design is that the PV panel connection consists of two separate components with coupling and indeterminate dimension. In this paper, the gap element is employed in these two separated but coupled components, i.e., hook and catch. Topology optimization is applied to optimize and design the cross-section of the PV panel connection. Pareto optimization is conducted to operate the optimization subject to multiple load scenarios. The initial design for the topology optimization is determined by the common design specified by the Technical Code for Glass Curtain Wall Engineering (JGJ 102-2003). Gravity and wind load scenarios are considered for the optimization and numerical analysis. Post analysis is conducted for the optimal design obtained by the topology optimization due to the manufactory requirements. Generally, compared with the conventional design, the optimized connector reduces material use with improved structural characteristics.

Luminance Assessment of Outdoor Lighting for Advertisements at Night (옥외광고용 발광조명의 야간휘도분포 분석)

  • Shin, Hwa Young;Lee, Jong Soo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.

An Analysis of Electricity Consumption Profile based on Measurement Data in Apartment Complex in Daejeon (대전지역 공동주택의 전력소비 실태 및 패턴 분석 연구)

  • Kim, Kang Sik;Im, Kyung Up;Yoon, Jong Ho;Shin, U Cheul
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.91-96
    • /
    • 2011
  • This study is to analysis the characteristics of electric power consumption of apartments complex in Korea. This study shows the pattern of electric power consumption and correlation of each apartment complex's completion year monthly and timely. With this result, we are able to predict the demand pattern of electricity in a house and make the schedule by demand pattern. It is expected this data is used as reference of electric consumption of Daejeon area to operate the simulation tools to predict the building energy. The yearly data of 10 apartment complexes of 2010 are analyzed. The results of this study are followed. The averaged amount of electricity consumption in winter is higher as summer because of the high capacity of heating equipment. All of the house has electric base load from 0.26kWh to 0.5kWh. The average of the electricity consumption of month is shown as 310.2kWh. A week is seperated, as 4 part such as week, weekend, Saturday and Sunday. During week, the average of timely electricity consumption is shown as 0.426kWh. The Saturday consumption is 0.437kWh. The Sunday is 0.445kWh. The peak electricity consumption in summer and winter is measured. The peak consumption on summer season is 1.389kW on 22th August 64% higher than winter season 0.887kW on 3rd January.