• 제목/요약/키워드: Building energy consumption

검색결과 895건 처리시간 0.03초

공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

선형절삭시험에 의한 코니컬커터의 삽입재 크기에 따른 절삭성능 평가 (Performance estimation depending on the insert size of conical picks by linear cutting test)

  • 최순욱;강태호;장수호;이철호;이규필;김창용
    • 한국터널지하공간학회 논문집
    • /
    • 제18권2호
    • /
    • pp.221-233
    • /
    • 2016
  • 본 연구는 로드헤더 커팅헤드에 사용되는 코니컬커터의 삽입재 크기에 따른 커터작용력의 변화를 살펴보기 위하여 절삭간격과 절삭깊이, 그리고 사각을 변화시키면서 연직력, 절삭력, 구동력을 측정하였고 그 측정결과의 평균값을 사용하여 분석을 실시하였다. 절삭간격이 12~27 mm인 조건에서 절삭깊이에 따라 평균 커터작용력이 일정한 범위에서 나타났다. 사각이 $0^{\circ}$인 경우에서는 일반적으로 알려진 최적 S/d비 1~5사이인 4~4.5 조건에서 비에너지가 최소로 나타났으며, 사각이 $6^{\circ}$인 경우에서는 최적 S/d비가 좀 더 작은 1~3에서 나타났다. 단순히 시험결과에 의한 비교에서는 슬림 코니컬커터가 헤비 코니컬커터에 비해 절삭효율이 좋게 나타났지만, 대상지반의 강도가 높을 경우에 대해 커터의 소모량과 손상을 고려한다면 헤비 코니컬커터의 사용이 효과적일 것이다.

건축용 바닥재로부터의 휘발성유기화합물 방출특성 (Emission Characteristics of Volatile Organic Compounds from Building Flooring Materials)

  • 윤중섭;이명화;엄석원;김민영;김종호;김신도
    • 대한환경공학회지
    • /
    • 제32권10호
    • /
    • pp.973-978
    • /
    • 2010
  • 에너지절감에 대한 인식이 높아짐에 따라 점차 건물이 밀폐화되고 있으며, 이로 인하여 실내공기질에 영향을 미치는 건축자재로부터의 휘발성유기화합물 방출에 대한 관심이 높아지고 있다. 그러므로 실내공기질을 개선하는데 있어 건축자재로부터의 VOCs 방출특성을 파악하는 것이 무엇보다 중요하다. 본 연구에서는 우리나라가 온돌문화인 점을 고려하여 대표적인 건축자재인 온돌마루와 접착제를 대상으로, 방출챔버시험을 통하여 온도 및 시간경과에 따른 헥산, 톨루엔 및 TVOCs 방출특성을 살펴보았다. VOCs의 방출속도는 온도와 비례관계를 나타내었으며, 바닥재에 존재하는 VOCs 발생원이 어느 위치에, 어떠한 형태로 존재하느냐가 시간의 경과에 따른 방출특성에 크게 영향을 미친다는 것을 알 수 있었다. 즉, 건축자재로부터의 헥산, 톨루엔의 방출은 전반적으로 초기에 방출속도가 높고 시간이 지남에 따라 점차 줄어드는 경향을 보이고 있으나, 온돌마루로부터의 톨루엔 방출은 다른 양상을 보이는데 시간이 지남에 따라 방출속도가 오히려 증가하여 6시간 경과 후 최대값을 보인 뒤 점차 감소하는 경향을 나타내었다. 이는 온돌마루에 함유되어 있는 톨루엔 발생원이 자재의 내부에 많이 존재하고 있기 때문에 시간이 경과함에 따라 방출속도가 증가했다가 다시 감소하는 경향을 보인 것으로 추정된다. 바닥재로부터의 VOCs 방출특성 실험결과를 종합하여 살펴보면, 온돌시스템에서 방출되는 고농도의 VOCs에 인체노출을 줄이기 위해서는 이사하기 전에 적어도 72시간 이상의 Bake-out 시간이 필요할 것이라 사료된다.

국내 주거 단지에 대한 전과정 환경영향 분석 (Analysis regarding the Environmental Impact of the Life Cycle of Housing Complexes in Korea)

  • 최두성;전흥찬;조균형
    • 한국건설관리학회논문집
    • /
    • 제15권5호
    • /
    • pp.13-21
    • /
    • 2014
  • 본 연구는 건축물 중 공동주택 단지를 대상으로, 건축물에 투입되는 자재생산부터 건축물이 해체되는 전과정동안 환경에 미치는 영향을 6개의 환경영향 범주로 구분하여 정량적으로 산출하였으며, 국내의 모든 산업이 환경에 미치는 영향을 대략적으로 분석하여 비교 평가하였다. 총 27 단지에 대한 환경영향을 분석한 결과 단지를 구성하는 건물 및 시설별로는 공동주택 건물이 단지 전체 대비 약 88.2%를 차지하는 것으로 분석되었으며, 이후 지하주차장, 공통부분, 복지시설, 판매시설, 기타시설 순으로 환경에 미치는 영향이 큰 것으로 분석되었다. 이중 가장 영향이 큰 공동주택 건물만을 대상으로 분석한 경우에는 전과정 중 사용단계에서 환경에 미치는 영향이 가장 크게 나타났으며 이후 자재생산단계, 시공단계, 해체 및 폐기단계 순으로 환경에 미치는 영향이 크게 분석되었다. 또한 공동주택 건물의 전과정에 대한 환경영향 분석 결과 국내 총 산업 대비 약 11. 96%를 차지하는 것으로 분석되었다.

초미세입자 제거를 위한 나노세라믹 필터의 성능 평가 (Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles)

  • 김종원;안영철;이병권;정현재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발 (Development of Nano Ceramic Structures for HEPA Type Breathing Wall)

  • 김종원;안영철;김길태
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

이중 열원 히트펌프 시스템의 난방 성능과 운전 특성 (Heating Performance of Heat Pump System Using Dual Heat Source and Its Operation Characteristics)

  • 임효재;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.30-41
    • /
    • 2021
  • This paper presents the heating performance analysis results of a heat pump system using a dual heat source. In this paper, a dual heat source refers to the ground-coupled heat exchanger using both a surface water heat exchanger (SWHE) and a vertical ground heat exchanger (VGHE). In order to evaluate the system performance, we installed a monitoring system to measure the temperature and power consumption of a heat pump and then collected operation data with 4 different load burdened ratios of the dual heat source heat exchanger. During the whole measurement period, the average heating capacity of a water-to-water heat pump unit was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the dual heat source heat exchanger used 6.7 kW of power. Therefore the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the entire system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the dual heat source heat exchanger.

OCP Cold Storage 테스트베드 (OCP Cold Storage Test-bed)

  • 이재면;강경태
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제22권3호
    • /
    • pp.151-156
    • /
    • 2016
  • 클라우드 컴퓨팅이 주목을 받으며 대규모 스토리지 서버에 대한 필요성이 증대됐고, 그에 따라 소비전력 절감이 중요한 연구 주제로 부상하고 있다. 그러나 산업계에서 운영 중인 대규모 데이터 센터를 실험용으로 구축하는데 물리적 한계가 있기 때문에, 많은 선행 연구가 제안한 에너지 절감 기법들의 효과를 입증하는데 어려움을 겪고 있다. 이에 따라, 본 연구는 산업계에서 운영 중인 오픈소스 기반의 OCP Cold Storage를 소규모 테스트 베드로 구축하고, 이를 활용한 스토리지 서버의 정확한 소비 전력 측정 방안을 제고하였다. 또한, 제안한 테스트베드는 클라우드 응용 플랫폼과의 결합을 통해 쉽게 확장 가능하기 때문에, 저전력 스토리지 서버의 정책 개발 및 성능 평가에 크게 기여할 수 있을 것으로 기대한다.

건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구 (An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.203-211
    • /
    • 2021
  • 최근 건축물의 에너지 사용 저감을 위한 단열 설계기준은 강화되고 있다. 단열공사는 건축물의 단위면적당 1차 에너지 소요량 저감을 위한 가장 효율적인 방법임에도 불구하고, 건축 시공 및 준공검사 과정에서 단열성능에 대한 평가(검사) 기준이 없는 실정이다. 본 연구는 열관류율 측정장비(TESTO 435)를 활용하여 공동주택의 외벽 열관류율을 간편하게 실험 할 수 있는 방법과 분석기법에 대한 기준을 구축하여 객관적인 데이터를 제공하는 데 목적이 있다. 실험 대상 외벽의 단위면적당 비열(열용량)이 20 kJ(m2·K)를 초과하여 ISO 9869-1에 적합한 종료 시점의 데이터를 평균법으로 분석했다. 3일 연속 열관류율 측정값은 설계값 대비 +5% 이내로 허용오차 범위 내로 수렴했고, 일자별 열관류율의 표준편차는 1-Day > 3-Day > 2-Day 순으로 작아졌고, 시간대별 열관류율 표준편차는 00:00~24:00 > 19:00~07:00 > 00:00~07:00 순으로 줄어 들었다. 특히, 측정일자별로 00:00~07:00 시간대의 열관류율 값은 설계값 대비 -3%~+2% 편차로 거의 일치하였다.

애스터리스크(*) 배열구조 기반 전력저감 수배전반 (Asterisk(*) Array structure based power reduction power distribution board)

  • 김미숙;박동삼
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.138-144
    • /
    • 2017
  • 오늘날 전력수요 급증에 따른 전력소비량이 증가하고 있어 전력손실을 줄일 수 있는 에너지 저감을 위한 설계 또는 설비 대체로 전력의 고품질화가 필요하다. 배전반이란 한전의 발전설비로부터 전기를 공급받아 각 건물에 필요한 설비에 계통별 또는 용도별로 나누어 주는 기계장치이다. 배전반은 일반적으로 외함, 개폐기, 전력용 도체, 제어부분으로 구성된다. 본 연구는 배전반내의 메인 요소인 통전을 위한 전력용 도체에 관한 것이다. 실효교류저항 측정시험을 통해 기존방식 판상도체의 수직 배열구조가 비효율적 구조임을 입증해 본다. 실효교류저항이 많이 증가하면 표피효과로 인해 상대적으로 도체의 단면적이 커지게 된다. 본 연구는표피효과를 줄여 실효교류저항을 최소화시키는 애스터리스크(*) 배열구조를 기반으로 설계하여 에너지 절약과 원자재 절감을 연구하였다. 본 연구의 핵심기술 원리는 애스터리스크 배열구조를 적용하여 도체저항 감소기술 기반 에너지 절감 수배전반이다. 수배전반의 교류전력 공급용 판상도체 각각(rst 또는 abc)의 상에서 발생한 자기장이 상호작용으로 상쇄 소멸될 수 있도록 한 판상도체 배열구조에 관한 것으로 효과로는 판상도체에서 유도성 리액턴스의 발생량이 줄어들면서 유효단면적이 증가, 실효교류저항을 줄인다.