• 제목/요약/키워드: Building energy consumption

검색결과 895건 처리시간 0.028초

룰 베이스를 이용한 정풍량 공조기 고장 검출 및 진단 시스템의 실험적 연구 (An Experimental Study on the Rule Based Fault Detection and Diagnosis System for a Constant Air Volume Air Handling Unit)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.872-880
    • /
    • 2004
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of the air-conditioning system. In this study, an air handling unit fault test apparatus was built and fault diagnosis algorithms were applied to diagnose various faults of an air handling unit. Test results showed the good diagnosis for applied faults. Therefore, these algorithms may be effectively used to develope the real time fault detection and diagnosis system for the air handling unit.

공동주택 난방용 자동온도조절기의 성능해석 연구 (A Study on the Performance of Automatic Thermostatic Valves for Hot Water Heating System in Residential Buildings)

  • 안병천;이태원;김용기;송재엽
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.457-462
    • /
    • 2005
  • In this study, the performance of automatic thermostatic valves according to each heating method of a large scale residential building were researched by simulation. The flow characteristics of the entire pipe networks of the hot water radiant heating system is analized by using linear analysis method. For the analysis of unsteady heat transfer phenomena in each household, the method of using electric equivalent R-C circuit is applied.

  • PDF

옥상슬래브 단열조건에 따른 옥상녹화의 열환경 조정효과 (The Control of Temperature of Green Roof System with the Roof Slab Insulation Method)

  • 여인애;조홍제;윤성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.869-872
    • /
    • 2008
  • On this study, the Control of Temperature is specified on the view of indoor comfort and building energy consumption. It is estimated by Dynamic heat load simulation which has the factors of insulation method and the soil thickness of the green roof system. The fact that the model which has no insulation has the greatest effect of dropping high temperature and the cooling load decrease is confirmed.

  • PDF

포항가속기연구소의 전력사용량에 대한 분석 (Analysis of used electric power for pohang accelerator laboratory)

  • 손창호;손윤규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.31-32
    • /
    • 2006
  • Pohang accelerator Laboratory is from 1994 analyzed electric power amount used for about 10 years. It is one of equipment that consume electric power of greate electric power to single test equipment. Accelerator Laboratory institute investigates the consumption rate of energy that is spent to each building could divide by linear accelerator and save ring and analyzed about the equipment utilization rate and average electric power. Countermeasure that this treatise can forecast power loss of electric power by equipment through analysis of electric power amount used and heighten the utilization rate of equipment wishes to do comparative analysis.

  • PDF

A Survey on Role of Block Chain in Smart Cities

  • Chokkanathan, K;Shanmugaraja, P;Ramasamy, Siva Shankar;Ouncharoen, Rujira;Chakpitak, Nopasit
    • International Journal of Computer Science & Network Security
    • /
    • 제21권7호
    • /
    • pp.1-7
    • /
    • 2021
  • An amazing growth in the field of Internet of Things (IoT) and Blockchain based smart cities from both industry and academia has been witnessed in the recent years. There are many smart applications such as intelligent transportation, smart banking, improving the life style of citizen, energy consumption and managing the waste in the city, handling home needs are supporting the Smart city concept. These applications are profoundly supported by the advanced technologies like Blockchain as well as IoT in the recent past. Smart cities can be supported by the Blockchain core concepts such as secure, transparent, decentralized and immutable nature. Still, Blockchain and IoT technologies implementation in smart cities are in their early stages and significant research efforts are desirable to integrate them. This review article explores the roles and responsibilities of Blockchain and IoT in building smart cities.

The Effect of Plan Shape and Diagrid Angle on Structural Efficiency of Tall Buildings

  • Amirreza Ardekani;Matin Alaghmandan
    • 국제초고층학회논문집
    • /
    • 제12권2호
    • /
    • pp.153-162
    • /
    • 2023
  • Achieving sustainable spaces is one of the emerging trends of tall buildings regarding their significant impacts on the cities. Reducing energy consumption and material using is investigated as a widely used approach to achieve more efficient tall buildings. Defining more efficient geometries and form modifications have been adopted for this goal. In this paper the effect of plan shape and diagrid angle on structural efficiency of diagrid tall buildings have been studied. A parametric workbench is applied to generate and analyze models. The goal is to find effective form parameters resulting in more efficient forms. Respectively, all models were generated in Rhino/grasshopper architecturally and analyzed by a finite element plug-in structurally. Based on the results, steeper angles almost cause more displacements and needs to be more stiffened. it can be seen almost more sided models need less weight for the structures and it could lead to more efficient forms.

Experimental Study of Moisture-Wicking Fabric as Cooling Pad for Novel Rotary Direct Evaporative Cooler

  • Sang-Hwan Park;Jae-Weon Jeong
    • 국제초고층학회논문집
    • /
    • 제12권4호
    • /
    • pp.335-341
    • /
    • 2023
  • This study proposes a novel rotary direct evaporative cooler and investigates the potential of a moisture-wicking fabric as a cooling pad for the proposed evaporative cooler. The rotary direct evaporative cooler rotates the cooling pad to reduce the water and energy consumption of the pump compared to those of existing direct evaporative coolers. A moisture-wicking fabric is considered as the material of the cooling pad, because of its high moisture-wicking property, enhancing water evaporation. Experiments are performed under various inlet air conditions while measuring the air temperature, relative humidity, air velocity, and differential pressure. The evaporative cooling efficiency and impacts of the inlet air temperature and air velocity on the cooling performance are also evaluated. The results demonstrate the potential of the moisture-wicking fabric as cooling pad of direct evaporative cooler.

S-FEAR: Secure-Fuzzy Energy Aware Routing Protocol for Wireless Sensor Networks

  • Almomani, Iman;Saadeh, Maha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권4호
    • /
    • pp.1436-1457
    • /
    • 2018
  • Secure routing services in Wireless Sensor Networks (WSNs) are essential, especially in mission critical fields such as the military and in medical applications. Additionally, they play a vital role in the current and future Internet of Things (IoT) services. Lightness and efficiency of a routing protocol are not the only requirements that guarantee success; security assurance also needs to be enforced. This paper proposes a Secure-Fuzzy Energy Aware Routing Protocol (S-FEAR) for WSNs. S-FEAR applies a security model to an existing energy efficient FEAR protocol. As part of this research, the S-FEAR protocol has been analyzed in terms of the communication and processing costs associated with building and applying this model, regardless of the security techniques used. Moreover, the Qualnet network simulator was used to implement both FEAR and S-FEAR after carefully selecting the following security techniques to achieve both authentication and data integrity: the Cipher Block Chaining-Message Authentication Code (CBC-MAC) and the Elliptic Curve Digital Signature Algorithm (ECDSA). The performance of both protocols was assessed in terms of complexity and energy consumption. The results reveal that achieving authentication and data integrity successfully excluded all attackers from the network topology regardless of the percentage of attackers. Consequently, the constructed topology is secure and thus, safe data transmission over the network is ensured. Simulation results show that using CBC-MAC for example, costs 0.00064% of network energy while ECDSA costs about 0.0091%. On the other hand, attacks cost the network about 4.7 times the cost of applying these techniques.

에어캡 적층을 통한 에어캡 벽 모듈 개발 (Development of Aircap Wall Module through the Lamination of Aircap)

  • 김경수;서장후;김용성;이행우
    • 설비공학논문집
    • /
    • 제29권10호
    • /
    • pp.504-514
    • /
    • 2017
  • The insulation performance of aircaps has been recognized and various studies regarding the aircap as a solution to increased building energy consumption are being carried out. However, the aircap is not durable and therefore it cannot play the role of an independent finishing material. Accordingly, the purpose of this study is to suggest an aircap wall module with improved durability through the lamination of the aircap and verify its effectiveness by evaluating its energy saving performance for lighting and air conditioning through a full-scale testbed. The conclusions of this study are as follows. 1) The aircap wall module featuring a laminated aircap that is being proposed in this study can save lighting energy due to the permeability of the aircap in comparison to previous insulating materials. 2) The aircap wall module with a laminated aircap is effective in improving heating and air-conditioning energy saving when it is more than 15 cm-thick during summer and winter in comparison to a 5 cm-thick prefabricated panel. 3) The aircap wall module featuring a laminated aircap is effective in improving lighting and heating and air-conditioning energy saving when it is 10 cm- and 5 cm-thick during summer and winter, respectively, in comparison to a 5 cm-thick prefabricated panel.

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.